• Title/Summary/Keyword: Surface decontamination

Search Result 141, Processing Time 0.04 seconds

Investigation of Nanoparticle Generation during Surface Decontamination by Low-Energy-Fluence Laser Ablation (저에너지 플루언스(fluence) 레이저 어블레이션(ablation)을 통한 표면오염제거과정에서의 나노입자의 생성에 관한 연구)

  • Lee, Doh-Won;Cheng, Meng-Dawn
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.199-199
    • /
    • 2003
  • During the cleanup of US Department of energy facilities, contaminated materials, toxic and hazardous radionuclides (e.g., Th, Cs, and U) and heavy metals (e.g., Cr, Hg, Pb, and Ni)-laden ultrafine particles are generated. The size of the particles is up to about 200 nm. Understanding of the production of these nanometer size particles is critical in determining the surface cleaning efficiently. (omitted)

  • PDF

Process Analysis on the Decontamination of Internal Surface of $UF_6$ Cylinder ($UF_6$ 실린더 내부표면 제염에 관한 공정분석)

  • Chun, Kwan-Sik;Yoo, Sung-Hyun;Cho, Young-June;Hong, Jang-Pyo;Han, Wook-Jin;Choi, Beong-Soon;Kang, Pil-Sang;Cho, Suk-Ju
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.3
    • /
    • pp.161-165
    • /
    • 2009
  • To evaluate the efficiency of the decontamination plant for the removal of uranium compounds deposited on the internal surface of $UF_6$ cylinder for its reuse, two demonstration tests of the plant with different ratio of ${Na_2}{CO_3}$ and ${H_2}{O_2}$ were carried out, and each test had 5 steps. The main chemical form removed by the tests was to be identified as ${Na_4}{UO_2}(CO_3)_3$. More than 50% of uranium was removed by water of the first step, and at the following steps the removal amounts were exponentially decreased. On the other hand, the result shows that the injected amount of ${Na_2}{CO_3}$, compared with that of the removed uranium, was stoichiometrically excessed. This suggests that the injected amounts of ${Na_2}{CO_3}$, the generation rate of decontaminated waste, and the decontamination steps could be reduced by a process optimization of the plant.

  • PDF

Effect of Saliva Contamination Stage and Different Decontamination Procedures on Bonding Strength of Resin-Modified Glass Ionomer (레진강화형 글라스아이오노머의 초기 결합력과 타액오염 제거의 상관관계)

  • Go, Hanho;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.2
    • /
    • pp.158-164
    • /
    • 2019
  • The purpose of this study was to compare the bond strength of resin-modified glass ionomer (RMGI) to dentin with saliva contamination at different stages and using different decontamination procedures. Extracted human permanent molars were embedded onto acrylic resin with the dentin surface exposed. Group I was a control group that was conditioned with polyacrylic acid (PAA). Groups II and III were contaminated with saliva before PAA conditioning and Groups IV, V, and VI were contaminated with saliva after PAA conditioning. After saliva contamination, Groups II and IV were dried, Groups III and V were rinsed and dried, and Group VI was additionally conditioned with PAA. After surface treatment, the dentin specimens were filled with RMGI. Group I showed significantly higher bond strength than the other groups. Group VI showed a significantly higher bond strength than the other saliva contaminated groups. However, there were no significant differences in the failure mode between the different groups. Saliva contamination impaired the bond strength of RMGI to dentin, regardless of when the saliva contamination occurred. Decontamination with washing and drying could not improve the shear bond strength of RMGIC. When saliva contamination occurred after PAA conditioning, additional PAA conditioning improved the shear bond strength.

Studies on Growth and Decontamination of Listeria Monocytogenes Attached to Food Contact Surface Materials (식품접촉물질에 부착된 Listeria monocytogenes의 증식 및 제거에 관한 연구)

  • 윤정희;고영림;나승식;이용욱
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.75-82
    • /
    • 2001
  • Microorganisms can attach firmly to food contact surface material and the resitance of adherent bacteria differ markedly from planktonic cells. Therefore, adherent cells are a potential contamination problem to the food preparation because of their high resistance. to sanitation and heat treatment. This study was carried out in order to investigate growth and decontamination of Listeria monocytogenes attached to stainless steel, glass and plastic. Listeria monocytogenes cells could attach to all types of surface at three temperatures after contact times for 24 hrs. The numbers of adherent cells were greater at higher temperatures, but not increased with incubation time. When recovery of adherent cells was investigated, after 24 grs, the numbers of adherent cells were about 10$^{7}$ , 10$^{10}$ , 11$^{11}$ at 4$^{\circ}C$, $25^{\circ}C$, 3$0^{\circ}C$ repectively. Planctonic cells decreased by 2 log cycles after exposure to the domestic sanitizer. Adherent cells showed high resistance to domestic sanitizers and that was dependent upon surface materials studied, being greatest on plastic followed by stainless steel and glass. Adherent cells were more resistant to heat treatment than planktonic cells. When adherent cells were exposed to the temperature of 5$0^{\circ}C$, 55$^{\circ}C$, 57.5$^{\circ}C$ for 10 min, their populations did not decrease significantly. When the temprature increased to 6$0^{\circ}C$, cells attached to all types of surfaces were completely inactivated for 10 min.

  • PDF

Evaluation of Concrtet Properties Using Silicon-Based Repellent (실리콘기반 침투강화제를 사용한 콘크리트의 내구특성 평가)

  • Hwang, Byoung-Il;Kim, Hyo-Jung;Lee, Byung-Jae
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.295-301
    • /
    • 2019
  • Currently, the most commonly used decontamination agent in the country is calcium chloride, and the use of decontamination agents nationwide is on the rise due to climate change in the country. The deicing agent, aimed at deicing snow, is sprayed and the chloride is frozen and thawed by the dissolved surface water, causing various damages such as deterioration to the concrete. Therefore, in this study, the reactive urethane polymer was manufactured to coat concrete surface protection material, which is a method that prevents moisture from externally penetrating by applying to concrete surfaces, and the mixing agent was selected through the size control of molecules and surface modification, and the properties of penetrant stiffening agents and the application method of concrete was evaluated.

Crevice Corrosion Properties of PWR Structure Materials Under Reductive Decontamination Conditions (환원제염조건에서 가압경수로 구조재료의 틈부식 특성)

  • Jung, Jun-Young;Park, Sang Yoon;Won, Hui Jun;Choi, Wang Kyu;Moon, Jei Kwon;Park, So Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.3
    • /
    • pp.199-209
    • /
    • 2014
  • Crevice corrosion tests were conducted to examine the corrosion properties of HYBRID (HYdrazine Base Reductive metal Ion Decontamination) which was developed to decontaminate the PWR primary coolant system. To compare the corrosion properties of HYBRID with commonly existing decontamination agents, oxalic acid (OA) and citric oxalic acid (CITROX) were also examined. Type 304 Stainless Steel (304 SS) and Alloy 600 which are major components of the primary coolant system in Pressurized Water Reactor (PWR) were evaluated. Crevice corrosion tests were conducted under very aggressive conditions to confirm quickly the corrosion properties of primary coolant system structure components which have high corrosion resistance. Pitting and IGA were occurred in crevice surface under OA and CITROX conditions. But localized corrosion was not observed under HYBRID condition. Very low corrosion rate of less than $1.3{\times}10^{-3}{\mu}m/h$ was observed under HYBRID condition for both materials. On the other hand, under OA condition, Alloy 600 indicated comparatively uniform corrosion rate of $4.0{\times}10^{-2}{\mu}m/h$ but 304 SS indicated rapid accelerated corrosion in lower case than pH 2.0. In case of HYBRID condition, general corrosion and crevice corrosion were scarcely occurred. Therefore, material integrity of HYBRID in decontamination of primary coolant system in pressurized water reactor (PWR) reactor was conformed.

Flow Characteristics Analysis of the Decontamination Device with Mixing and Diffusion Using Radio-Isotopes Tracer (방사성 동위원소를 이용한 제염제 혼합확산장치의 유동특성분석)

  • Oh, Daemin;Kang, Sungwon;Kim, Youngsug;Jung, Sunghee;Moon, Jinho;Park, Jangguen
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.282-287
    • /
    • 2017
  • The purpose of this study was predicted the effects of mixing and diffusion due to the operation of the apparatus before the development of the mixed diffusion device for the decontamination absorbent to minimize the influence of contaminant inflow due to radiation accident. The tracer used for the flow characteristics was $^{68}Ga$, $^{99m}Tc$, which is a radioactive isotope, and 2 inch NaI radiation detector was used to detect it. The impeller of the decontamination mixed diffusion system applied to this study was made into three types and the mixing diffusion effect was compared. As a result of analyzing the flow characteristics of the radio-isotope with decontamination mixed diffusion device, mixing, diffusion and flow pattern were obtained. The radial mixing type impeller was able to diffuse to the water surface by the upflow flow, and the fin structure was adjusted for finding optimal conditions. The model 3 type consists of a fin guiding part and an auxiliary fin so that the diffusion speed is higher than that of other types of impellers. It also showed a short time to reach complete mixing.

The effects of ozone therapy as an adjunct to the surgical treatment of peri-implantitis

  • Isler, Sila Cagri;Unsal, Berrin;Soysal, Fatma;Ozcan, Gonen;Peker, Elif;Karaca, Inci Rana
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.3
    • /
    • pp.136-151
    • /
    • 2018
  • Purpose: The decontamination procedure is a challenging aspect of surgical regenerative therapy (SRT) of peri-implantitis that affects its success. The purpose of the present study was to determine the impact of additional topical gaseous ozone therapy on the decontamination of implant surfaces in SRT of peri-implantitis. Methods: A total of 41 patients (22 males, 19 females; mean age, $53.55{\pm}8.98years$) with moderate or advanced peri-implantitis were randomly allocated to the test group (ozone group) with the use of sterile saline with additional ozone therapy or the control group with sterile saline alone for decontamination of the implant surfaces in SRT of peri-implantitis. Clinical and radiographic outcomes were evaluated over a period of 12 months. Results: At the 12-month follow-up, the plaque and gingival index values were significantly better in the ozone group (P<0.05). Probing depth decreased from $6.27{\pm}1.42mm$ and $5.73{\pm}1.11mm$ at baseline to $2.75{\pm}0.7mm$ and $3.34{\pm}0.85mm$ at the end of the 12-month observation period in the ozone and control groups, respectively. Similarly, the clinical attachment level values changed from $6.39{\pm}1.23mm$ and $5.89{\pm}1.23mm$ at baseline to $3.23{\pm}1.24mm$ and $3.91{\pm}1.36mm$ at the 12-month follow-up in the ozone and control groups, respectively. According to the radiographic evidence, the defect fill between baseline and 12 months postoperatively was $2.32{\pm}1.28mm$ in the ozone group and $1.17{\pm}0.77mm$ in the control group, which was a statistically significant between-group difference (P<0.05). Conclusions: Implant surface decontamination with the additional use of ozone therapy in SRT of peri-implantitis showed clinically and radiographically significant. Trial registry at ClinicalTrials.gov, NCT03018795.

Improved Treatment Technique for the Reuse of Waste Solution Generated from a Electrokinetic Decontamination System (동전기제염장치에서 발생한 폐액의 재사용을 위한 개선된 처리기술)

  • Kim, Wan-Suk;Kim, Seung-Soo;Kim, Gye-Nam;Park, Uk-Ryang;Moon, Jei-Kwon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • A large amount of acidic waste solution is generated from the practical electrokinetic decontamination equipments for the remediation of soil contaminated with uranium. After filtration of uranium hydroxides formed by adding CaO into the waste solution, the filtrate was recycled in order to reduce the volume of waste solution. However, when the filtrate was used in an electrokinetic equipment, the low permeability of the filtrate from anode cell to cathode cell due to a high concentration of calcium made several problems such as the weakening of a fabric tamis, the corrosion of electric wire and the adhension of metallic oxides to the surface of cathode electrode. To solve these problems, sulfuric acid was added into the filtrate and calcium in the solution was removed as $CaSO_4$ precipitate. A decontamination test using a small electrokinetic equipment for 20 days indicated that Ca-removed waste solution decreased uranium concentration of the waste soil to 0.35 Bq/g, which is a similar to a decontamination result obtained by distilled water.

A Study on the Removal Characteristics of a Radioactively Contaminated Oxide Film from the irradiated Stainless Steel Surface using Short Pulsed Laser Ablation (초단 펄스레이저 어블레이션에 의한 스테인리스강 표면의 오염산화막 제거 특성)

  • Kim, Geun-Woo;Yoon, Sung-Sik;Kim, Ki-Chul;Lee, Myung-Won;Kang, Myungchang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.10
    • /
    • pp.105-110
    • /
    • 2020
  • Radioactive Oxides are formed on the surface of the primary equipment in a nuclear power plant. In order to remove the oxide film that is formed on the surfaces of the equipment, chemical and physical decontamination technologies are used. The disadvantage of traditional technologies is that they produce secondary radioactive wastes. Therefore, in this study, the short-pulsed laser eco-friendly technology was used in order to reduce production of the secondary radioactive wastes. They were also used to minimize the damages that were caused on the base material and to remove the contaminated oxide film. The study was carried out using a Stainless steel 304 specimen that was coated with nickel-ferrite particles. Further, the laser source was selected with two different wavelengths. Furthermore, the depth of the coating layer was analyzed using a 3D laser microscope by changing the laser ablation conditions. Based on the analysis, the optimal conditions of ablation were determined using a 1064nm short-pulsed laser ablation technique in order to remove the radioactively contaminated oxide film from the irradiated stainless steel surface.