• 제목/요약/키워드: Surface Effective Dose

검색결과 136건 처리시간 0.023초

6MV 선형가속기에서 Al/Cu에 관한 여과판 사용시 전자오염 감소에 관한 연구 (Reduction of Electron Contamination in Photon Beam by electron Filter in 6MV Linear Accelerator)

  • 이철수
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.41-54
    • /
    • 1996
  • The secondary electrons developed by interaction between primary beam and a tray mounted for blocks in Megavoltage irradiation result in excess soft radiation dose to the surface layer. To reduce this electron contamination, electron filters have been used to be attached under a tray. Various filters with Cu and Al plates in six different thickness and Cu/Al combined plates in 3 different thickness were tested to measure the reduction rate of secondary electron contamination to the surface layer. The measurement to find optimal filter was performed on 6MV linear accelerator in $10 cm{\times}10 cm$ field size and fixed 78.5cm source to measurement points distance from surface to maximum build up point in 2mm intervals. The result was analyzed as the ratio of measured doses with using filters, to standard doses of measured open beam. The result of this study was fellowing : 1. The contaminated low energy radiation were mainly produced by blocking tray. 2. The surface absorbed dose was slowly increased by increasing irradiation field size but rapidly increased at field size above $15cm{\times}15cm$. 3. Al plate upto 2.5mm thickness used as a filter was found to be inadequate due to the failure of reduction of the surface absorbed dose below doses of the under surface upto the maximal build up. Cu 0.5mm plate and Cu 0.28mm/A1 1.5mm compound plate were found to be optimal filters. 4. By using these 2 filters, the absorbed dose to the surface were effectively reduced $5.5\%$ in field size $4cm{\times}4cm,\;11.3\%$ in field size $10cm{\times}10cm,\;22.3\%$ in field size $25cm{\times}25cm$. 5. In field size $10cm{\times}10cm$, the absorbed dose to the surface of irradiation was reduced by setting TSD 20cm at least,. but effective and enough dose reduction could be achieved by setting TSD 30cm as 2 optimal filters used. 6. More surface dose absorbed at TSD less than 7.4cm with a tray and filters together indicated that soft radiation was also developed by filters. 7. The variation of PDD by the different size of irradiation field was minimal as 2 optimal filters used. There was also not different in variation of PDD according to using any of two different filters. 8. PDD was not effected either by various TSD or by using the different filter among two.

  • PDF

Important Radionuclides and Their Sensitivity for Ground water Pathway of a Hypothetical Near-Surface Disposal Facility

  • Park, J. W.;K. Chang;Kim, C. L.
    • Nuclear Engineering and Technology
    • /
    • 제33권2호
    • /
    • pp.156-165
    • /
    • 2001
  • A radiological safety assessment was performed for a hypothetical near-surface radioactive waste repository as a simple screening calculation to identify important nuclides and to provide insights on the data needs for a successful demonstration of compliance. Individual effective doses were calculated for a conservative ground water pathway scenario considering well drilling near the site boundary. Sensitivity of resulting ingestion dose to input parameter values was also analyzed using Monte Carlo sampling. Considering peak dose rate and assessment time scale, C-14 and T-129 were identified as important nuclides and U-235 and U-238 as potentially important nuclides. For C-14, the dose was most sensitive to Darcy velocity in aquifer The distribution coefficient showed high degree of sensitivity for I-129 release.

  • PDF

Simultaneous degradation of nitrogenous heterocyclic compounds by catalytic wet-peroxidation process using box-behnken design

  • Gosu, Vijayalakshmi;Arora, Shivali;Subbaramaiah, Verraboina
    • Environmental Engineering Research
    • /
    • 제25권4호
    • /
    • pp.488-497
    • /
    • 2020
  • The present study investigates the feasibility of nitrogenous heterocyclic compounds (NHCs) (Pyridine-Quinoline) degradation by catalytic wet peroxidation (CWPO) in the presence of nanoscale zerovalent iron supported on granular activated carbon (nFe0/GAC) using statistical optimization technique. Response surface methodology (RSM) in combination with Box-Behnken design (BBD) was used to optimize the process parameters of CWPO process such as initial pH, catalyst dose, hydrogen peroxide dose, initial concentration of pyridine (Py) and quinolone (Qn) were chosen as the main variables, and total organic carbon (TOC) removal and total Fe leaching were selected as the investigated response. The optimization of process parameters by desirability function showed the ~85% of TOC removal with process condition of initial solution pH 3.5, catalyst dose of 0.55 g/L, hydrogen peroxide concentration of 0.34 mmol, initial concentration of Py 200 mg/L and initial concentration of Qn 200 mg/L. Further, for TOC removal the analysis of variance results of the RSM revealed that all parameter i.e. initial pH, catalyst dose, hydrogen peroxide dose, initial concentration of Py and initial concentration of Qn were highly significant according to the p values (p < 0.05). The quadratic model was found to be the best fit for experimental data. The present study revealed that BBD was reliable and effective for the determination of the optimum conditions for CWPO of NHCs (Py-Qn).

피폭선량 산출을 통한 피부입사선량 계산: 머리 및 손목을 중심으로 (Entrance Surface Dose according to Dose Calculation : Head and Wrist)

  • 성호진;한재복;송종남;최남길
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.305-312
    • /
    • 2016
  • 본 연구에서는 진단용 X선 검사에서 환자에게 피폭되는 두부 및 사지를 다양한 선량 계산법을 통해 실측 선량과 비교 실험하였다. 또한 촬영 장비의 형태, 장비 설정조건, X선의 용량, X선관과 환자와의 거리, X선 후방산란차이 등을 고려한 새로운 계산 방법을 제시하여 피폭선량을 산출하였다. 그 결과 피부입사선량이 기존의 선량 계산법보다 실측과의 오차가 줄어들었으며, 환자가 피폭되는 선량을 쉽게 계산할 수 있었고 의료선량 평가가 이루어지게 되어 방사선 관련 종사자들의 의료 선량 관리가 더욱 수월해지는 계기가 될 것으로 사료된다.

점선원 감마선장에서 유효선량의 성별차 및 개연선량당량과의 차이 (Effective Doses in the Radial Gamma Radiation Field near a Point Source: Gender Difference and Deviation from the Personal Dose Equivalent)

  • 장재권;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제22권4호
    • /
    • pp.299-307
    • /
    • 1997
  • 점선원 주위에 형성되는 방사상의 감마선장에서 개인선량당량 $H_p$, 유효선량 E, 성별 유효선량 $E^m$$E^f$를 MIRD형 남녀 모의 피폭체를 이용하여 평가하였다. 선원은 신체의 전방 각각 15, 40 및 100 cm 거리의 여러 높이에 있는 것으로 하였고 방사성 핵종으로는 시범적으로 $^{137}Cs$$^{131}I$을 선정하였다. 성별 유효선량에서는 일부 예외적인 경우-예를 들면 선원이 생식선 앞에 위치할 때-를 제외하고는 대체로 여성의 경우가 크게 나타났으나, 남녀 평균값과의 차이는 크지않아 방사상 감마선장에서 성별 유효선량환산인자를 사용할 필요성은 없었다. 선량계를 가슴에서 하복부까지의 몸통 전방에 착용할 경우에는 $H_p$/E의 비가 약$1{\sim}3$의 범위에 있었고 극단적인 경우는 0.34에서 6.5까지 큰 편차를 보였다. 그러나 일반적인 방사선원 취급방법과 선량계 착용위치(흉곽 전방)를 가정하고, 선량계가 넓고 평행한 방사선장에서 유효선량에 대해 교정된다면 평행하지는 않지만 넓은 빔인 방사상 감마선장에 대해서는 용인할 수 있는 오차의 범위에서 유효선량 평가치를 제공할 수 있을 것으로 나타났다.

  • PDF

Surface energy change and hydrophilic formation of PE, PS and PTFE films modification by hydrogen ion assisted reaction

  • Jung Cho;Ki Hyun;Koh, Seok-Keun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.202-202
    • /
    • 1999
  • The Polyethylene (PE), Polystyrene (PS) and Polytetrafluoroethylene (PTFE) surface modification was investigated by hydrogen io assisted reaction (H-IAR) in oxygen environment. The IAR is a kind of surface modification techniques using ion beam irradiation in reactive gas environment. The energy of hydrogen ion beam was fixed at 1keV, io dose was varied from 5$\times$1014 to 1$\times$1017 ions/$\textrm{cm}^2$, and amount of oxygen blowing gas was fixed 4ml/min. Wettability was measured by water contact angles measurement, and the surface functionality was analyzed by x-ray photoelectron spectroscopy. The contact angle of water on PE modified by argon ion beam only decrease from 95$^{\circ}$ to 52$^{\circ}$, and surface energy was not changed significantly. But, the contact angle using hydrogen ion beam with flowing 4ml/min oxygen stiffly decreased to 8$^{\circ}$ and surface energy to 65 ergs/cm. In case of PS, the contact angle and surface energy changes were similar results of PE, but the contact angle of PTEE samples decreased with ion dose up to 1$\times$1015 ions/$\textrm{cm}^2$, increased at higher dose, and finally increased to the extent that no wetting was appeared at 1$\times$1017 ions/$\textrm{cm}^2$. These results must be due to the hydrogen ion beam that cleans the surface removing the impurities on polymer surfaces, then hydrogen ion beam was activated with C-H bonding to make some functional groups in order to react with the oxygen gases. Finally, unstable polymer surface can be changed from hydrophobic to hydrophilic formation such as C-O and C=O that were confirmed by the XPS analysis, conclusionally, the ion assisted reaction is very effective tools to attach reactive ion species to form functional groups on C-C bond chains of PE, PS and PTFE.

  • PDF

고선량 Co-60 선원이용시 차폐된 질 원주기구의 영향 (Dose Distributions in a Shielded Vaginal Cylinder using a HDR Co-60 Source)

  • 김진기;김정수;김형진;권형철;강정구
    • 한국의학물리학회지:의학물리
    • /
    • 제8권1호
    • /
    • pp.37-45
    • /
    • 1997
  • 차폐된 질 원주기구를 이용한 강내치료시 Co-60 선원에 대한 정확한 흡수선량을 결정 하고자 선원을 교정하고, 질 원주기구에 의한 선량분포변화를 조사하였다. 선량분포의 변화량은 직경 2.5 cm 차폐된 질 원주기구를 폴리스틸렌 팬톰에 설치하여 전리함으로 측정하였으며, 부채꼴 모양인 0.55cm 두께의 9$0^{\circ}C$ 연으로 차폐된 면과 차폐되지 않은 면의 선량분포에 대한 영향을 상대선량 감소율로 측정하였다. 측정된 선량분포의 변화량을 제작사의 선량분포도 및 다점 분할방식으로 구한 선량율표와 비교하였다. 질 원주기구를 이용한 선량 감소율은 차폐되지 않은 변의 경우 원주기구 표면 1cm 거리에서 4.4%를 보였고, 차폐된 면에서는 원주기구 표면에서 20.4% 를 나타냈다. 9$0^{\circ}C$연 차폐된 질 원주기구의 선량감쇄효율은 Co-60 선원에서 평균 0.2가 되었다. Co-60 이동형 선원의 선량분포는 다 점분할방식의 선량율표와 4.1% 이내로 일치하였다.

  • PDF

Digital Chest Radiography에서 방사선량에 대한 Source to Image-Receptor Distance (SID)의 영향 (The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography)

  • 권순무;박창희;박정규;송운흥;정재은
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.203-210
    • /
    • 2014
  • X선을 이용한 chest radiography는 일반적으로 180 cm의 SID에서 실시되고 있다. digital chest radiography에서 AEC를 적용하고 120 kVp, 320 mA에서 SID를 180 cm부터 340 cm까지 20 cm 단위로 증가시켜 가며 영상의 질과 환자선량의 관계를 알아보았다. chest phantom 영상의 정성적인 영상평가를 위해 VGA를, 정량적인 평가를 위해 SNR을 분석하였다. 선량은 ESAK로 측정하고 effective dose는 PCXMC를 이용하였다. 연구결과 일반적으로 시행되는 SID 180 cm를 기준으로 했을 때, ESAK의 경우 240 cm, 280 cm, 320 cm에서 각각 8.7%, 11.47%, 13.56%의 유의한 감소가 있었다. effective dose의 경우 전신에 대해 2.89%, 4.67%, 6.41%의 감소, 폐에서 5.08%, 6.98%, 9.6%의 감소가 관찰되었다. SNR의 경우 각각 9.04%, 8.24%, 11.46%의 감소가 관찰되었으며 특히, SID 260 cm ~ 300 cm 구간에서 8.03%의 작은 감소가 나타났고 SID 340 cm까지도 5.24로 5이하로 감소되지 않았다. VGA에서는 통계적으로 유의한 차이가 없는 진단적 가치가 높은 영상으로 평가되었다. 따라서 eigital chest radiography에서 SID를 300 cm까지 증가시킴으로 화질의 저하 없이 환자선량을 감소시킬 수 있을 것으로 기대된다.

저준위 및 극저준위 방사성폐기물 표층처분시설의 인간침입 시나리오 안전평가에 대한 고찰 (Safety Assessment on the Human Intrusion Scenarios of Near Surface Disposal Facility for Low and Very Low Level Radioactive Waste)

  • 홍성욱;박상호;박진백
    • 방사성폐기물학회지
    • /
    • 제14권1호
    • /
    • pp.79-90
    • /
    • 2016
  • The second-stage near surface disposal facility for low and very low level radioactive waste's permanent disposal is to be built. During the institutional control period, the inadvertent intrusion of the general public is limited. But after the institutional control period, the access to the general public is not restricted. Therefore human who has purpose of residence and resource exploration can intrude the disposal facility. In this case, radioactive effects to the intruder should be limited within regulatory dose limits. This study conducted the safety assessment of human intrusion on the second-stage surface disposal facility through drilling and post drilling scenario. Results of drilling and post drilling scenario were satisfied with regulatory dose limits. The result showed that post-drilling scenario was more significant than drilling scenario. According to the human intrusion time and behavior after the closure of the facility, dominant radionuclide contributing to the intruder was different. Sensitivity analyses on the parameters about the human behavior were also satisfied with regulatory dose limits. Especially, manual redistribution factor was the most sensitive parameter on exposure dose. A loading plan of spent filter waste and dry active waste was more effective than a loading plan of spent filter waste and other wastes for the radiological point of view. These results can be expected to provide both robustness and defense in depth for the development of safety case further.

Mevatron KD 8067 선형가속기의 23 MV 광자선의 특성 (Characteristics of 23 MV Photon Beam from a Mevatron KD 8067 Dual Energy Linear Accelerator)

  • 김옥배;최태진;김영훈
    • Radiation Oncology Journal
    • /
    • 제8권1호
    • /
    • pp.115-124
    • /
    • 1990
  • 고 에너지 23MV광자선의 특성 중 임상적용에 중요한 심부선량 백분율, 조직-최대선량비 (TMR), 산란-최대선량비 (SMR), 표면선량 및 출력선량 보정계수등의 변수가 이온전리 (IC-10)함 및 평행 평판전리 (PS-033)함에 의해 측정 조사되었다. 명목상의 23 MV X-선에 대한 가속에너지는 $18.5\pm0.5$ MV로 측정되었다. Mevatron KD 8067의 23 MV X-선의 중심선속의 반가층이 기하학적인 좁은 선속으로 측정되었으며 반가층의 두께는 $24.5\;g/cm^2$이었다. 조직-최대선량비는 심부선량백분율표에서 구해졌으며, 실측치와 비교한 결과 각 조사면의 크기와 깊이에서 약간의 차이를 보였으나 평균 $0.7\pm0.5$의 오차를 나타내고 있어 계산에 의한 TMR 값과 잘 일치함을 보였다. 조사면 $0\times0\;cm^2$의 TMR 값은 zero 조사면의 유효감약계수에 의한 값과, 각 조사면의 조직-최대 선량비로 부터 비선형최소자승법에 의해 구해진 유효선흡수계수 및 반가층 측정에 의한 유효선흡수 계수에 의한 값들로 비교되었으며, $\mu=0.0283{\pm}0,0002cm^{-1}$을 보였고, 세 방법 모두 오차범위내에서 잘 일치됨을 보였다. 한편, 불규칙 조사면의 선량계산에 이용될 SMR은 조사면의 반경 50cm까지 계산되어 대형 조사 면에서도 선량율 산출이 이루어지도록 하였다. Mevatron KD 8067의 23 MV X-선의 조직 표면선량은 SSD 100 cm, 1$10\times10\;cm^2$의 조사면에서 최대조직선량율의 $9.6\%,\;25\times25\;cm^2$에서는 $25.4\%$를 보였다.

  • PDF