• Title/Summary/Keyword: Surface EMG Signal

Search Result 87, Processing Time 0.024 seconds

Experimental Study on Walking Motion by Ankle Electromyograms (족관절의 근전도를 이용한 보행운동의 실험적 연구)

  • Hong, J.H.;Chun, H.Y.;Jeon, J.H.;Jung, S.I.;Kim, J.O.;Park, K.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.10
    • /
    • pp.934-939
    • /
    • 2011
  • This paper experimentally deals with the relationship between the ankle electromyogram(EMG) and walking motion in order to activate the ankle joint of a walking-assistance robot for rehabilitation. Based on the anatomical structure and motion pattern of an ankle joint, major muscles were selected for EMG measurements. Surface EMG signals were monitored for several human bodies at various stride distances and stride frequencies. Root-mean-squared magnitude of EMG signals were related with the walking conditions. It appeared that the magnitude of the ankle EMG signal was linearly proportional to the stride distance and stride frequency, and thus to the walking speed.

A Virtual Robot Control Method using a Hand Signals (수신호를 이용한 가상 로봇의 제어 방식)

  • 정경권;이정훈;임중규;정성부;엄기환
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.378-381
    • /
    • 2002
  • In this paper, we proposed an electromyography(EMG) based control method of a virtual robot arm as an adaptive human supporting system or remote control system, which consists of an shoulder control part, elbow control part, and wrist control part. The system uses four surface electrodes to acquire the EMG signal from operator. It is shown from the experiments that the EMG patterns during arm motions can be classified sufficiently by using SOM and LVQ. The interface system based on PC environment is constructed to 3-D graphic user interface(GUI) program. Experimental results show that proposed method obtains approximately 94 percent of success in classification.

  • PDF

Spike Variable Analysis of Surface EMG Signal During Constant Voluntary Contraction (일정한 자의 수축 시 표면 근전도 신호에 대한 Spike 변수 해석)

  • Yang, Hee-Won;Joung, Eui-Kon;Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.809-816
    • /
    • 2007
  • This paper presents an analysis of the SEMG signal quantitatively and automatically using spike variables : MSF, MSA, MSS, and MSD. The SEMG signals were recorded in three muscle parts, first dorsal interosseus, biceps brachii and abductor policis brevis, from 14 normal subjects. Emphasis was placed on the following 3 points in the experiments. 1) Suggest proper window length to estimate the spike variables 2) Investigate variation of the spike variables to varying %MVC. 3) Investigate variation of the spike variables to the sustained contraction for 30 minutes. Quantitative results were showed and examined in point of practical clinical application.

Knee Rehabilitation System through EMG Signal analysis and BLDC Motor Control (근전도 신호 분석 및 BLDC모터 제어를 통한 무릎재활시스템)

  • Kwon, Hyeong-Gi;Ko, Hyeong-Gyu;Song, Yoon-Oh;Son, Eui-Seong;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.1009-1018
    • /
    • 2019
  • This paper describes the design and implementation of a rehabilitation medical device based on a EMG measurement. Rehabilitation systems are controlled using BLDC motors and motor drives. The BLDC motor drive controls the operation and the speed controls the drive through the external servo motor. In addition, potentiometer coupled to the outside of the motor transmits information about the position of the load being rotated by the motor. The rehabilitation algorithm is controlled by limiting the maximum angle of 0 to 120 by utilizing the motor according to the user setting stage during the rehabilitation exercise. The walking algorithm compensates motor control for the low leg of the signal using the difference value of the signal obtained with the surface denser attached to both inner muscles. The motor and surface denser are utilized for the walk motion to control the maximum angle of 0 to 80.

Comparison of the Surface Electromyographic Signal of Progressive Resistance Increase and Progressive Resistance Decrease Exercise (점진적 저항증가와 점진적 저항감소 운동에서의 표면 근전도 신호 비교)

  • Han, Kyoung-Ju;Choi, Bo-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • Purpose: This study was undertaken to compare the signal characteristics of surface electromyography (EMG) between progressive resistive increase exercise (PRIE) and progressive resistive decrease exercise (PRDE). Methods: Forty healthy male subjects were randomly assigned to either the PRIE group or the PRDE group. Subjects participated in the PRIE and PRDE methods, with 10 RM for each subject. EMG activity was recorded from the rectus femoris muscle. Outcome data were collected for both groups pre-exercise, immediately post-exercise, then at 5 and 10 minutes post-exercise. Repeated measures 2-way ANOVA was used to determine the statistical difference of the root mean square (RMS) in EMG activity. Results: We showed that RMS values, when compared with pre-exercise, were decreased immediately after exercise and were increased at 5 and 10 minutes after exercise (p<0.05). The RMS values were not significantly different between the two groups (p>0.05). Conclusion: These results can indicate that both the PRIE and PRDE protocols will be improve strength with equivalent efficacy. Further studies are needed to address exercise duration, frequency of exercise sessions, and rest times than the PRIE and PRDE protocols with regard to the changes in strength improvement without a large amount of muscle fatigue.

  • PDF

Movement Intention Detection of Human Body Based on Electromyographic Signal Analysis Using Fuzzy C-Means Clustering Algorithm (인체의 동작의도 판별을 위한 퍼지 C-평균 클러스터링 기반의 근전도 신호처리 알고리즘)

  • Park, Kiwon;Hwang, Gun-Young
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.1
    • /
    • pp.68-79
    • /
    • 2016
  • Electromyographic (EMG) signals have been widely used as motion commands of prosthetic arms. Although EMG signals contain meaningful information including the movement intentions of human body, it is difficult to predict the subject's motion by analyzing EMG signals in real-time due to the difficulties in extracting motion information from the signals including a lot of noises inherently. In this paper, four Ag/AgCl electrodes are placed on the surface of the subject's major muscles which are in charge of four upper arm movements (wrist flexion, wrist extension, ulnar deviation, finger flexion) to measure EMG signals corresponding to the movements. The measured signals are sampled using DAQ module and clustered sequentially. The Fuzzy C-Means (FCMs) method calculates the center values of the clustered data group. The fuzzy system designed to detect the upper arm movement intention utilizing the center values as input signals shows about 90% success in classifying the movement intentions.

Study on Micro Dried Bio-potential Electrodes Using Conductive Epoxy on Textile Fabrics (전도성 에폭시를 이용한 직물 위에 구현된 건식 생체전위 전극의 연구)

  • Cha, Doo-Yeol;Jung, Jung-Mo;Kim, Deok-Su;Yang, Hee-Jun;Choi, Kyo-Sang;Choi, Jong-Myong;Chang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.5
    • /
    • pp.367-372
    • /
    • 2013
  • In this paper, micro dried bio-potential electrodes are demonstrated for sEMG (surface ElectroMyoGraphic) signal measurement using conductive epoxy on the textile fabric. Micro dried bio-potential electrodes on the textile fabric substrate have several advantages over the conventional wet/dry electrodes such as good feeling of wearing, possibility of extended-wearing due to the good ventilation. Also these electrodes on the textile fabric can easily apply to the curved skin surface. These electrodes are fabricated by the screen-printing process with the size of $1mm{\times}10mm$ and the resultant resistance of these electrodes have the average value of $0.4{\Omega}$. The conventional silver chloride electrode shows the average value of $0.3{\Omega}$. However, the electrode on the textile fabric are able to measure the sEMG signal without feeling of difference and this electrode shows the lower resistance of $1.03{\Omega}$ than conventional silver chloride electrode with $2.8{\Omega}$ in the condition of the very sharp curve surface (the radius of curvature is 40 mm).

Frequency analysis of EMG signals using power spectrum density (전력 스펙트럼 밀도를 이용한 근전도 신호의 주파수 해석)

  • Kim, Kwnag-Soon;Byun, Youn-Sik;Park, Sang-Hui
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1985 no.06
    • /
    • pp.5-8
    • /
    • 1985
  • This paper describes the use of power spectral densing in the examination of the electromogram (EMG). The EMG signals were obtained with surface electrodes from the biceps brachii muscle. Shifts of the high-energy regions of the power spectra can be inferred from the changes in the mean frequency. This paper is consistent with result that most information of EMG signal is located 10-200 Hz.

  • PDF

Monophthong Recognition Optimizing Muscle Mixing Based on Facial Surface EMG Signals (안면근육 표면근전도 신호기반 근육 조합 최적화를 통한 단모음인식)

  • Lee, Byeong-Hyeon;Ryu, Jae-Hwan;Lee, Mi-Ran;Kim, Deok-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.3
    • /
    • pp.143-150
    • /
    • 2016
  • In this paper, we propose Korean monophthong recognition method optimizing muscle mixing based on facial surface EMG signals. We observed that EMG signal patterns and muscle activity may vary according to Korean monophthong pronunciation. We use RMS, VAR, MMAV1, MMAV2 which were shown high recognition accuracy in previous study and Cepstral Coefficients as feature extraction algorithm. And we classify Korean monophthong by QDA(Quadratic Discriminant Analysis) and HMM(Hidden Markov Model). Muscle mixing optimized using input data in training phase, optimized result is applied in recognition phase. Then New data are input, finally Korean monophthong are recognized. Experimental results show that the average recognition accuracy is 85.7% in QDA, 75.1% in HMM.

Development of Wearable Robot for Elbow Motion Assistance of Elderly (노약자의 팔꿈치 거동 지원을 위한 착용형 로봇 개발)

  • Jang, Hye-Yoen;Han, Chang-Soo;Kim, Tae-Sik;Jang, Jae-Ho;Han, Jung-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.141-146
    • /
    • 2008
  • The purpose of this study is to develop the algorithm which can control muscle power assist robot especially for elderly. Recently, wearable robots for power assistance are developed by many researchers, and its application fields are also variable such as for medical or military equipment. However, there are many technical barriers to develop the wearable robot. This study suggest a control method improving performance of a wearable robot system by using a EMG signal of major muscles and a force sensor signal as command signal of system. The result of the robot Prototype efficiency experiment, the case of Maximum Isometric motion it suggest 100% power of muscle, the man need only 66% of MVIC(Maximum Voluntary Isometric Contraction) to lift 5kg dumbbell without robot assist. However the man needs only 52% of MVIC to lift 5kg dumbbell with robot assist. Therefore 20% muscle power increased with robot assist. Also, we designed light weight robot mechanism that extract the command signal verified and drive the wanted motions.