• Title/Summary/Keyword: Support Position

Search Result 1,010, Processing Time 0.029 seconds

Design and Parametric Study on Discone Antenna for Broadband RF Test Chamber

  • Oh, Soon-Soo;Kim, In-Ryeol;Choi, Dong-Geun;Park, Wook-Ki
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.534-538
    • /
    • 2016
  • This paper discusses the characteristics and effects of dielectric inner-supports on discone antenna for broadband RF test chamber, and the verification has been performed by simulation. Several design parameters such as the thickness of the gap support, the position of the side support, and the thickness of the side support has been analyzed. The thickness of the gap support affected the reflection coefficient. An effect of the offset of the side support from the center was slight below 3 GHz and significant above 3 GHz. The thickness of the side support did not affect the reflection coefficient or the gain much. The performance of the fabricated discone antenna was in good agreement with the simulated results. This investigation of a dielectric support effects could be used to design a commercial discone antenna for broadband RF test chamber, focusing on electrical performance and mechanical stability.

Comparison of Lumbar Joint Reposition Error When Sitting in Upright and Slouched Positions for Five Minutes (5분 동안 바로 앉은 자세와 구부린 앉은 자세 시 허리 관절재위치 오류의 비교)

  • Ji, Myung-Ki;Choung, Sung-Dae;Park, Kyue-Nam;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.20 no.2
    • /
    • pp.20-27
    • /
    • 2013
  • The purpose of this study was to compare the slouched and upright sitting positions on lumbar joint reposition error (LJRE). Twenty subjects without low back pain were recruited for this study and, using a random number table, were randomly assigned to two groups; the upright sitting position group (UP group) and the slouched sitting position group (SP group). UP group was first asked to sit in an upright position and the SP group to sit in a slouched position as an intervention, and then the LJRE of both groups was measured at the neutral sitting position (lumbar flexion $0^{\circ}$). The measurement of the LJRE was repeated after one day. The sitting positions were performed for five minutes each and the LJRE was measured using an electronic goniometer. An independent t-test was used to compare the LJRE of both groups after each sitting position and after one day. The results of this study showed that the LJRE after an intervention in the UP group was lower than in the SP group (p<.05) and the LJRE after one day in the UP group was lower than in the SP group (p<.05). The findings of this study indicate that the upright sitting position can be applied to decrease LJRE, compared with the slouched sitting position. These findings also support that the upright sitting position reduces the potential for proprioceptive loss.

Design and Evaluation of a Low-floor Care-bed for Elderly People (고령자용 저상 요양침대의 설계 및 평가)

  • Bae, Ju-Hwan;Moon, Inhyuk
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.1
    • /
    • pp.29-35
    • /
    • 2017
  • It was hard for a conventional care-bed to be realized to a low-floor position due to a complex actuation mechanism installed under the mattress support platform. In this paper a mechanism design to set a low-floor position as well as to adjust back- and leg-rest angles was proposed. A dual motor was applied to the back- and leg-rest mechanism of which design parameters were determined by an optimal method. An elevation mechanism was also designed to enlarge a limited stroke range up to two times of its original stroke using a pulley mechanism. An evaluation test was performed by five healthy subjects ($24.4{\pm}0.5yrs.$) when going up from a floor position to a preset best position which was set to the 240mm height for a prototype low-floor bed and to the 600mm height for a conventional bed. As a result, the moving distance was 38% lower than the conventional bed when the subject used the low-floor bed. It showed that the low-floor care-bed reduced physical burdens and was effective to assist activities of daily living of the elderly people.

A Study on Educational CD-Title develop to Basic Life Support (기본인명구조술 교육용 CD-Title 개발 연구)

  • Lee, Jung-Eun;Koh, Bong-Yeun;Ahn, Kisoo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.8 no.1
    • /
    • pp.33-45
    • /
    • 2004
  • The study is designed to develop an educational CD-Title for Basic Life Support. The study is conducted from July to December, 2002, Based on the course of program development suggested by Dick and Cray. the study followed the planning, development, education and evaluation of a program. The developed CD-Title consists of 8 parts. 1. Intro include Introduction, Adult CPR, Child CPR, Infant CPR, Adult Foreign-Body Airway Obstruction, Infant Foreign-Body Airway Obstruction, and Exercise in Menu at Right of screen. 2. Introduction consist of death process at cardiac arresst, chain of survival, introduction of CPR, respiratory & ciculatory anatomy and physiology. 3. Adult CPR consist of assessment responsiveness, activating EMS system, position victim, opening a airway, checking for breathing, rescue breathing, checking for sign of circulation, chest compression, 1 person & 2 persion adult CPR video. 4. Child & Infant CPR consist of, causes, assessment responsiveness, position victim, opening the airway, checking for breathing, rescue breathing, checking for sign of circulation, chest compression, activating EMS system, child & infant CPR video. 5. Adult Foreign-Body Airway Obstruction include assessment responsiveness, activating EMS system, position victim, opening a airway, checking for breathing, 2 rescue breathing, reopening the airway, 2 rescue breathing, finger sweep, 5 abdominal thrusts, unresponsiveness adult Foreign-Body Airway Obstruction video. 6. Infant Foreign-Body Airway Obstruction consist of, causes, assessment responsiveness, position victim, opening the airway, checking for breathing, 2 rescue breathing, reopening the airway, 2 rescue breathing, checking foreign-body object in oral cavity of victim, 5 back blow, 5 chest thsusts, activating EMS system, video. 7. 32 exercise consist of 8 Adult CPR, 12 Child & Infant CPR, 5 Adult Foreign-Body Airway Obstruction, 7 Infant Foreign-Body Airway Obstruction. Every part consist of animations to trigger students interests. This CD-Title will be useful education for first responders and lay rescuers.

  • PDF

The Relationship Between Postural Control, ADL Function, Muscle Tone, and Functional Improvement in Chronic Stroke Patients (만성 뇌졸중 환자의 자세 조절과 일상생활동작, 근긴장도, 그리고 기능증진과의 관계)

  • An, Seung-Heon;Seo, Young-Jong;Park, Chang-Sik
    • Physical Therapy Korea
    • /
    • v.14 no.1
    • /
    • pp.64-73
    • /
    • 2007
  • The purpose of this study was to find any correlations among Postural Assessment Scale for Stroke (PASS), Modified Barthel Index (MBI), Tone Assessment Scale (TAS), Motor Assessment Scale-Gait (MAS-G), Fugl Meyer-Balance (FM-B), and to predict MBI from subscales of the PASS. The subjects were 41 stroke patients of the Korea National Rehabilitation Center in Seoul. The main outcome measures were postural control (PASS), gait (MAS-G), Balance (FM-B), Tone (TAS), ADL (MBI). The data was analyzed using the Pearson product correlation. PASS scale was used between other clinical and instrumental indexes, multiple stepwise regression analyses were performed to identify prognostic factors for ADL incline, and Cronbach's alpha coefficient was used to identify internal consistency on PASS scale. The results of this study areas follows: 1. The highest level was sitting without support, the lowest level was standing on paretic leg on PASS scale. The highest level was chair/bed transfer, the lowest level was bathing on MBI. 2. All items of the PASS, except postural tone were significantly correlated with Gait, Balance, MBI (p<.01), 3. The Internal Consistency (Cronbach's alpha coefficient=.85) was very high, indicating that the PASS is homogeneous and is likely to produce consistent response. Furthermore, the sums of maintaining position items and of changing-position items were strongly correlated (r=.64, p<.05) and there were significant correlations between sums of PASS, sums of maintaining position items (r=.87, p<.01), and changing-position items (r=.93, p<.01). 4. The standing without support of the PASS items was the strongest variance ($R^2$=.85) of the predicting ADL function. These findings provide strong evidence of the predictive value of the postural control on gait, Balance, ADL function in stroke patients and to can provide a reference for the successful therapeutic program and more improved functional recovery.

  • PDF

Dynamic Response of a Beam with a Spring Support Subject to a Moving Mass (탄성스프링 지지를 갖고 이동질량을 받는 보의 동적응답)

  • Lee, J.W.;Ryu, B.J.;Lee, G.S.;Song, O.S.;Lee, Y.L.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.868-873
    • /
    • 2003
  • This paper deals with the linear dynamic response of an elastically restrained beam under a moving mass, where the elastic support was modelled by translational springs of variable stiffness. Governing equations of motion taking into account of all inertia effects of the moving mass were derived by Galerkin's mode summation method, and Runge-Kutta integration method was applied to solve the differential equations. The effects of the speed, the magnitude of the moving mass, stiffness and the position of the support springs on the response of the beam have been studied. A variety of numerical results allows us to draw important conclusions for structural design purposes.

  • PDF

Critical Fluid Velocity of Fluid-conveying Cantilevered Cylindrical Shells with Intermediate Support (중간 지지된 유체 유동 외팔형 원통셸의 임계유속)

  • Kim, Young-Wann
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.5
    • /
    • pp.422-429
    • /
    • 2011
  • The critical fluid velocity of cantilevered cylindrical shells subjected to internal fluid flow is investigated in this study. The fluid-structure interaction is considered in the analysis. The cantilevered cylindrical shell is supported intermediately at an arbitrary axial position. The intermediate support is simulated by two types of artificial springs: translational and rotational spring. It is assumed that the artificial springs are placed continuously and uniformly on the middle surface of an intermediate support along the circumferential direction. The steady flow of fluid is described by the classical potential flow theory. The motion of shell is represented by the first order shear deformation theory (FSDT) to account for rotary inertia and transverse shear strains. The effect of internal fluid can be considered by imposing a relation between the fluid pressure and the radial displacement of the structure at the interface. Numerical examples are presented and compared with existing results.

Research on the Rocket Motor Support Structure Inserted inside the Missile Fuselage (동체 내삽형 추진기관 연결장치 연구)

  • Park, Kyoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.265-270
    • /
    • 2010
  • This paper presents the rocket motor support structure to position solid rocket engine within a missile fuselage. When the rocket motor is mounted inside a missile fuselage, fuselage structure must be designed to withstand various structural problems resulting from inserted rocket motor such as axial thrust force, shock/vibration, axial deformation of the rocket motor tank in addition to the flight loads. The motor support structure system proposed in this paper proved to be very simple and efficient while satisfying all the design requirements.

  • PDF

Modifying linearly non-separable support vector machine binary classifier to account for the centroid mean vector

  • Mubarak Al-Shukeili;Ronald Wesonga
    • Communications for Statistical Applications and Methods
    • /
    • v.30 no.3
    • /
    • pp.245-258
    • /
    • 2023
  • This study proposes a modification to the objective function of the support vector machine for the linearly non-separable case of a binary classifier yi ∈ {-1, 1}. The modification takes into account the position of each data item xi from its corresponding class centroid. The resulting optimization function involves the centroid mean vector, and the spread of data besides the support vectors, which should be minimized by the choice of hyper-plane β. Theoretical assumptions have been tested to derive an optimal separable hyperplane that yields the minimal misclassification rate. The proposed method has been evaluated using simulation studies and real-life COVID-19 patient outcome hospitalization data. Results show that the proposed method performs better than the classical linear SVM classifier as the sample size increases and is preferred in the presence of correlations among predictors as well as among extreme values.

A Technique for Defect Detection of Condenser Tube in Support Plate Region using Guided Wave (유도초음파를 이용한 복수기 튜브지지판 영역에서의 결함검출기법)

  • Kim, Yong-Kwon;Park, Ik-Keun;Park, Sae-Jun;Ahn, Yeon-Shik;Gil, Doo-Song
    • Journal of Welding and Joining
    • /
    • v.30 no.6
    • /
    • pp.36-41
    • /
    • 2012
  • General condensers consist of many tubes supported by tube sheets and support plates to prevent the deflection of the condenser tubes. When a fluid at high pressure and temperature runs over the tubes for the purpose of transferring heat from one medium to another, the tubes vibrate and their surface comes into contact with the support plates. This vibration causes damage to the tubes, such as cracks and wear. We propose an ultrasonic guided wave technique to detect the above problems in the support plate region. In the proposed method, the ultrasonic guided wave mode, L(0,1), is excited using an internal transducer probe from a single position at the end of the tube. In this paper, we present a preliminary experimental verification using a super stainless tube and show that the defects can be discriminated from the support signals in the support region.