• 제목/요약/키워드: Supply apparatus

검색결과 125건 처리시간 0.03초

자기장 영향에 따른 자기유변탄성체의 구름 마찰 특성 연구 (A Study on Rolling Friction Characteristics of Magneto-Rheological Elastomer under Magnetic Fields)

  • 연성룡;이광희;김철현;이철희
    • Tribology and Lubricants
    • /
    • 제30권4호
    • /
    • pp.234-239
    • /
    • 2014
  • Magneto-rheological elastomer (MR elastomer) is a smart material, because it has mechanical properties that change under a magnetic field. An MR elastomer changes its stiffness characteristics when the inner particles (iron particles) align along the direction of a magnetic field. There has been much research to make use of this characteristic to control vibration issues in various mechanical systems, such as for mounting systems in the automotive field, home appliances, etc. Furthermore, the friction and wear properties of MR elastomer have been studied, as these relate to the durability of the material needed to meet engineering requirements. Rolling friction (or rolling resistance) is one of these friction properties, but has not yet been studied in the context of MR elastomers. In this study, an MR elastomer is fabricated in the shape of a hollow cylinder to evaluate the rolling friction characteristic under a magnetic field. The test apparatus is setup and a strain gauge is used to calculate the rolling resistance under test conditions. Permanent magnets are used to supply the magnetic field during tests. The load and rolling speed conditions are also considered for the tests. The test results show that rolling friction characteristic has a different trend under different magnetic field, load, and rolling speed conditions. It is assumed that the stiffness change of an MR elastomer under a magnetic field has an effect on the rolling friction characteristic of the MR elastomer. For the future work, the rolling friction characteristics of MR elastomers will be controlled by adjusting the strength of the magnetic field using electromagnets.

압출 적층 방식의 알루미늄 용융기의 설계 및 해석 (Design and Analysis of Aluminum Melting Machine in Fused Deposition Modeling Method)

  • 이현석;나영민;강태훈;박종규;박태곤
    • 한국기계가공학회지
    • /
    • 제14권4호
    • /
    • pp.62-72
    • /
    • 2015
  • Interest in three-dimensional (3D) printing processes has grown significantly, and several types have been developed. These 3D printing processes are classified as Selective Laser Sintering (SLS), Stereo-Lithography Apparatus (SLA), and Fused Deposition Modeling (FDM). SLS can be applied to many materials, but because it uses a laser-based material removal process, it is expensive. SLA enables fast and precise manufacturing, but available materials are limited. FDM printing's benefits are its reasonable price and easy accessibility. However, metal printing using FDM can involve technical problems, such as suitable component supply or the thermal expansion of the heating part. Thus, FDM printing primarily uses materials with low melting points, such as acrylonitrile butadiene styrene (ABS) or polylactic acid (PLA) resin. In this study, an FDM process for enabling metal printing is suggested. Particularly, the nozzle and heatsink for this process are focused for stable printing. To design the nozzle and heatsink, multi-physical phenomena, including thermal expansion and heat transfer, had to be considered. Therefore, COMSOL Multiphysics, an FEM analysis program, was used to analyze the maximum temperature, thermal expansion, and principal stress. Finally, its performance was confirmed through an experiment.

一定幅 急傾斜 開水路上을 流動하는 물의 깊이 變化에 관한 實驗的 硏究 (An Experimental Study on the Depth Variation of Water Flow on Steep Open Channel with Constant Width)

  • 박이동
    • 대한기계학회논문집
    • /
    • 제10권1호
    • /
    • pp.86-95
    • /
    • 1986
  • 본 연구에서는 폭이 일정한 급경사 개수노상(0.15mW*1.6mL)을 상온의 물이 유동할 때 유동율과 수로 급경사에 따른 명입치에서의 유동깊이 변화를 실측을 통하여 밝히고 이념치와 비교하였다.

Cardioprotective Effect of the Mixture of Ginsenoside Rg3 and CK on Contractile Dysfunction of Ischemic Heart

  • Kim, Jong-Hoon
    • Journal of Ginseng Research
    • /
    • 제31권1호
    • /
    • pp.23-33
    • /
    • 2007
  • Ginsenosides are one of the most well-known traditional herbal medicines frequently used for the treatment of cardiovascular symptoms in korea. The anti-ischemic effects of the mixture of ginsenoside $Rg_3$, and CK on ischemia-induced isolated rat heart were investigated through analyses of changes in hemodynamics ; blood pressure, aortic flow, coronary flow, and cardiac output. The subjects in this study were divided into four groups: normal control, the mixture of ginsenoside $Rg_3$ and CK, an ischemia-induced group without any treatment, and an ischemia-induced group treated with the mixture of ginsenoside $Rg_3$ and CK. There were no significant differences in perfusion pressure, aortic flow, coronary flow and cardiac output between them before ischemia was induced. The supply of oxygen and buffer was stopped for five minutes to induce ischemia in isolated rat hearts, and the mixture of ginsenoside $Rg_3$ and CK was administered during ischemia induction. Treatments of the mixture of ginsenoside $Rg_3$ and CK significantly prevented decreases in perfusion pressure, aortic flow, coronary flow, and cardiac output under ischemic conditions. In addition, hemodynamics (except heart rate) of the group treated with the mixture of ginsenoside $Rg_3$ and CK significantly recovered 60 minutes after reperfusion compared to the control group (mixture+ischemia vs ischemia - average perfusion pressure: 74.4${\pm}$2.97% vs. 85.1${\pm}$3.01%, average aortic flow volume: 49.11${\pm}$2.72% vs. 59.97${\pm}$2.93%, average coronary flow volume: 58.50${\pm}$2.81% vs. 72.72${\pm}$2.99%, and average cardiac output: 52.47${\pm}$2.78% vs. 63.11${\pm}$2.76%, p<0.01, respectively). These results suggest that treatment of the mixture of ginsenoside $Rg_3$ and CK has distinct anti-ischemic effects in ex vivo model of ischemia-induced rat heart.

$CO_2$ 열펌프용 내부 열교환기의 냉방조건에서 열전달 및 압력 강하 특성에 대한 연구 (Study on Heat Transfer and Pressure Drop Characteristics of Internal Heat Exchanger for $CO_2$ Heat Pump under Cooling Condition)

  • 김대훈;이상재;최준영;이재헌;권영철
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.517-525
    • /
    • 2008
  • In order to study the heat transfer and pressure drop of an internal heat exchanger for $CO_2$ heat pump under cooling condition, the experiment and numerical analysis were performed. Four kinds of internal heat exchangers with a coaxial tube type and a micro-channel tube type were used. The experimental apparatus consisted of a test section, a power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. The section-by-section method and Hardy-Cross method were used for the numerical analysis. The effects of the internal heat exchanger refrigerant flow rate, the length of the internal heat exchanger, the operating condition of the gas-cooler, the evaporator and the type of the internal heat exchangers were investigated. With increasing of the flow rate, the heat transfer rate increased about 25%. The heat transfer rate of the micro-channel tube type was higher about 100% than that of the coaxial tube type. With increasing of the length of the internal heat exchanger, the heat transfer rate increased about $20{\sim}50%$. The pressure drop of the low-side tube was larger compared with that of the high-side tube.

시그마 델타 변조에 의한 LED 드라이버의 입력 콘트롤러 설계 (Delta Sigma Modulation of Controller Input Signal for the LED Light Driver)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권2호
    • /
    • pp.151-155
    • /
    • 2016
  • 우리는 이 논문에서 ADPCM (adaptive differential pulse code modulation)을 적용함으로써 디밍 콘트롤러를 갖는 LED 드라이버의 설계를 제시한다. ADPCM 장비는 고해상도를 가지고 LED 전류를 정확하게 제어하며, 고조파 전류 펄스의 퍼짐으로 인하여 초래되는 RFI 를 감소시켜 준다. 또한 제어 동작의 정밀도를 높여준다. 이 연구에서 LED에 펄스 전류를 인가함으로써 고효율 에너지의 LED를 제어하는 디지털 제어회로의 설계를 제시한다. 우리가 설계한 LED 전류구동시스템은 디지털 제어 부와 아날로그 SMPS (스위치 모드 파워 서플라이)를 별도로 구현한 두개의 시스템이다. 입력레벨이 0.7 인 경우의 시뮬레이션 결과는 시그마 델타 변조를 하여 얻은 D/A 컨버터의 출력을 나타내었다. 개수가 510 개인 펄스신호의 경우 0.15 % 의 정밀도를 얻을 수 있었다.

성능이 향상된 Stack Monitoring System의 설계 (Design of Stack Monitoring System with Improved Performance)

  • 장경욱;이주현;이승원;이승호
    • 전기전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.299-302
    • /
    • 2016
  • 본 논문에서는 성능이 향상된 Stack Monitoring System을 설계한다. Stack Monitoring System의 증폭기(AMP)에 들어오는 펄스성 잡음을 차단하기 위하여, 차폐 및 전원부 임피던스를 낮추고 전원회로를 분리하여 노이즈를 차단한다. 신틸레이션 검출기 특성을 최대한 장치에 매칭하기 위한 가변 고전압, 이득(Gain), 상쇄(Offset), 한계(Threshold) 등을 설정 할 수 있는 제어부를 설계한다. 또한 300 ~ 1,500V의 가변 고전압 전원회로를 구성하여 다양한 신틸레이션 검출기에 적용가능 한 가변 전압 공급 장치를 설계한다. 성능이 향상된 Stack Monitoring System은 다종의 신틸레이션 검출기가 각각의 특성을 고려하여 동작하게 함으로서 효율적이고 높은 신뢰성을 보장한다. 개발된 Stack Monitoring System의 측정 불확도에 대하여 공인 시험기관의 장비를 사용하여 실험한 결과 우수한 성능을 나타내었다.

ANALYSES OF ANNULAR LINEAR INDUCTION PUMP CHARACTERISTICS USING A TIME-HARMONIC FINITE DIFFERENCE ANALYSIS

  • Seong, Seung-Hwan;Kim, Seong-O
    • Nuclear Engineering and Technology
    • /
    • 제40권3호
    • /
    • pp.213-224
    • /
    • 2008
  • The pumping of coolant in a liquid metal fast reactor may be performed with an annular linear induction electro-magnetic (EM) pump. Linear induction pumps use a traveling magnetic field wave created by poly-phase currents, and the induced currents and their associated magnetic field generate a Lorentz force, whose effect can be the pumping of the liquid metal. The flow behaviors in the pump are very complex, including a time-varying Lorentz force and pressure pulsation, because an induction EM pump has time-varying magnetic fields and the induced convective currents that originate from the flow of the liquid metal. These phenomena lead to an instability problem in the pump arising from the changes of the generated Lorentz forces along the pump's geometry. Therefore, a magneto-hydro-dynamics (MHD) analysis is required for the design and operation of a linear induction EM pump. We have developed a time-harmonic 2-dimensional axisymmetry MHD analysis method based on the Maxwell equations. This paper describes the analysis and numerical method for obtaining solutions for some MHD parameters in an induction EM pump. Experimental test results obtained from an induction EM pump of CLIP-150 at the STC "Sintez," D.V. Efremov Institute of Electro-physical Apparatus in St. Petersburg were used to validate the method. In addition, we investigated some characteristics of a linear induction EM pump, such as the effect of the convective current and the double supply frequency (DSF) pressure pulsation. This simple model overestimated the convective eddy current generated from the sodium flow in the pump channel; however, it had a similar tendency for the measured data of the pump performance through a comparison with the experimental data. Considering its simplicity, it could be a base model for designing an EM pump and for evaluating the MHD flow in an EM pump.

수평 평활관내 $CO_2$ 증발열전달 및 압력강하에 관한 연구 (Study on $CO_2$ Evaporation Heat Transfer and Pressure Drop in a Horizontal Smooth Tube)

  • 이상재;최준영;이재헌;권영철
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.615-621
    • /
    • 2007
  • Experimental study on the heat transfer characteristics of $CO_2$ in a horizontal smooth tube was carried out to investigate the heat transfer coefficient and pressure drop during evaporation of $CO_2$. The experiment apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes ($200{\sim}1200kg/m^2s$), heat flukes ($10{\sim}100kW/m^2$) and saturation temperatures (-5, 0, $5^{\circ}C$). With increasing the heat flux, the evaporation heat transfer coefficient increased. But the variation of the heat transfer coefficient on the increase of the mass flux was not large. And the significantly drops of the heat transfer coefficient was observed at any heat flux and mass flux because of the change of the flow pattern in the tube. With increasing the saturation temperature, the heat transfer coefficient increased due to the promotion of a nucleate boiling. The measured pressure drop during evaporation increased with increasing the mass flux and decreasing the saturation temperature.

미세채널 내 이산화탄소의 증발 열전달 특성 및 오일의 영향에 관한 실험적 연구 (Experimental Study on Characteristics of Evaporation Heat Transfer and Oil Effect of $CO_2$ in Mini-channels)

  • 이상재;김대훈;최준영;이재헌;권영철
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.16-22
    • /
    • 2009
  • In order to investigate $CO_2$ heat transfer coefficient and pressure drop by PAG oil concentration during $CO_2$ evaporation, the experiment on evaporation heat transfer characteristics in a mini-channels were performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes($300{\sim}800kg/m^{2}s$), heat fluxes($10{\sim}40kW/m^2$) saturation temperatures($-5{\sim}5^{\circ}C$), and PAG oil concentration(0, 3, 5wt%). The variation of the heat transfer coefficient was different according to the oil concentration. With the increase of the oil concentration, the evaporation heat transfer coefficient decreased and the delay of dryout by oil addition was found. Pressure drop increased with the increase of the oil concentration and heat flux, and the decrease of saturation temperature.