• 제목/요약/키워드: Supply air velocity

검색결과 124건 처리시간 0.025초

초고층공동주택 국소배기용 입상덕트의 배기성능평가에 관한 연구 (Study on the Performance Evaluation of the Exhaust Stack used in High Riser Public House)

  • 권용일;이태규;안정헌
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.889-894
    • /
    • 2008
  • Exhaust system used in toilet and cooking place of high riser public house is roof fan of two basic types : natural roof ventilator and natural/forced roof ventilator. Natural/forced roof ventilator has a motor in the rotary shaft. There are many high riser public house in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depend on stack effect. This study investigates on stack pressure determined by exterior pressure and the difference pressure control in exhaust stack used in high riser public house. This paper focuses mainly on the effect of the time interval for power supply of motor installed in roof fan with function of natural wind velocity and of exhaust air volume of toilet. It is observed there are higher exhaust efficiency than the existing natural roof ventilator.

  • PDF

응집과 여과를 이용한 조류의 초고속 제어에 관한 연구 (High-rate Removal of Algae by Using of Filtration System with Coagulant Addition)

  • 윤상린;김동하;이영규
    • 한국물환경학회지
    • /
    • 제18권2호
    • /
    • pp.221-228
    • /
    • 2002
  • Abundant growth of algae in raw water sources caused by eutrophication brings about significant side effects on water supply, such as taste and order problem, oxygen depletion, toxic material secretion, and filter clogging problem in water treatment process, etc. The purpose of this research is to remove the algae and phosphorus compounds in the Pal-dang reservoir promptly by using the upflow filtration system with coagulant addition. The filter tower consisted of sand media and sieve filter with air back-washing process. By using coagulation and filtration with $132{\mu}m$ pore size filter, about 55% and 70% of algae and phosphorus compounds were removed respectively. The experimental conditions were as follows; head loss of 0.2m, linear velocity of 200m/day, and filtration flux of 1000($L/m^2/day$). In the case of filtration with cartridge type filter of $25{\mu}m$ pore size, the filtration flux was about 7800 LMH, and the removal ratios of COD, SS, T-P, and Chlo-a. were 61%, 99%, 54%, and 98%, respectively. However, high pressure air back-washing process with should be required for the maintenance of such high filtration flux.

수직형 스마트 팜의 적정 생육환경 조성을 위한 건축 시스템 개발 - 수직형 스마트 팜에 최적화된 내부 공기 균일성 향상에 대한 연구 - (Development of Building System for Achieving an Optimal Growth Environment in a Vertical Smart Farm)

  • 김한돈;이정아;최세은;장현승;김지민
    • 한국건설관리학회논문집
    • /
    • 제22권4호
    • /
    • pp.3-10
    • /
    • 2021
  • 지구온난화 및 기후변화에 대한 전문 연구기관인 IPCC에 따르면 인간은 기후 시스템에 영향을 끼치고 있다. 이러한 기후 시스템의 변화는 기존 생육환경을 변화시켜 농업 분야의 식재료 공급에 문제를 야기할 수 있다. 이 문제를 해결하기 위해 수직형 팜은 안정적인 식재료의 공급을 위한 좋은 대안이 될 수 있다. 수직형 스마트 팜은 농작물의 생육환경 유지 및 관리에 깊은 관심을 쏟고 있음에도 불구하고 건축 공간에 온도, 습도, 조도, 산소, CO2 농도 등을 균일하게 구현하는 데에는 어려움이 있다. 공기의 균일성 확보를 위해 CFD 분석을 진행한 결과 주목할 만한 결과는 수직형 스마트 팜 내의 공기 균일성을 위해서는 적합한 CO2 농도를 장기간 지속적으로 분사하는 것이 유리하다는 것이다. 이 결과를 통해 수직형 스마트 팜에 최적화 된 생육환경 시스템을 효율적으로 계획할 수 있다. 본 연구를 기초로 수직형 스마트 팜의 최적화된 생육환경을 조성하여 효율적인 작물이 생산이 이루어진다면 농업 분야의 발전에 이바지 할 수 있을 것이다.

HEPA Filter형 숨쉬는 벽체용 나노세라믹 여재개발 (Development of Nano Ceramic Structures for HEPA Type Breathing Wall)

  • 김종원;안영철;김길태
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.274-279
    • /
    • 2008
  • In the perspective of saving energy in buildings, high performance of insulation and air tightness for improving the heating and the cooling efficiency has brought the positive effect in an economical view. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and it is also very harmful to residents because they spend over 90% of their time in the indoor area. Therefore, the ventilation is important to keep indoor environment clean and it can also save energy consumption. In this study, a HEPA type breathing wall is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. To make fine porous structures, polymer nano fibers which were made by electro spinning method are used as a precursor. The nano fibers are coated with SiO2 nano particles and finally the HEPA type breathing wall is made by sintering in the electric furnace at $300\sim500^{\circ}C$. The pressure drops of nano ceramic structure are 8.2, 25.5 and 44.9 mmAq at the face velocity of 2.0, 5.9 and 8.8 cm/s, respectively. Also the water vapor permeability is $3.6g/m^2{\cdot}h{\cdot}mmHg$. In this research, the porous nano ceramic structures are obtained and the possibility for the usage of a material for HEPA type breathing wall can be obtained.

반도체 웨이퍼 제조공정 클린룸 구조, 공기조화 및 오염제어시스템 (Clean Room Structure, Air Conditioning and Contamination Control Systems in the Semiconductor Fabrication Process)

  • 최광민;이지은;조귀영;김관식;조수헌
    • 한국산업보건학회지
    • /
    • 제25권2호
    • /
    • pp.202-210
    • /
    • 2015
  • Objectives: The purpose of this study was to examine clean room(C/R) structure, air conditioning and contamination control systems and to provide basic information for identifying a correlation between the semiconductor work environment and workers' disease. Methods: This study was conducted at 200 mm and 300 mm semiconductor wafer fabrication facilities. The C/R structure and air conditioning method were investigated using basic engineering data from documentation for C/R construction. Furthermore, contamination parameters such as airborne particles, temperature, humidity, acids, ammonia, organic compounds, and vibration in the C/R were based on the International Technology Roadmap for Semiconductors(ITRS). The properties of contamination control systems and the current status of monitoring of various contaminants in the C/R were investigated. Results: 200 mm and 300 mm wafer fabrication facilities were divided into fab(C/R) and sub fab(Plenum), and fab, clean sub fab and facility sub fab, respectively. Fresh air(FA) is supplied in the plenum or clean sub fab by the outdoor air handling unit system which purifies outdoor air. FA supply or contaminated indoor air ventilation rates in the 200 mm and 300 mm wafer fabrication facilities are approximately 10-25%. Furthermore, semiconductor clean rooms strictly controlled airborne particles(${\leq}1,000{\sharp}/ft^3$), temperature($23{\pm}0.5^{\circ}C$), humidity($45{\pm}5%$), air velocity(0.4 m/s), air change(60-80 cycles/hr), vibration(${\leq}1cm/s^2$), and differential pressure(atmospheric pressure$+1.0-2.5mmH_2O$) through air handling and contamination control systems. In addition, acids, alkali and ozone are managed at less than internal criteria by chemical filters. Conclusions: Semiconductor clean rooms can be a pleasant environment for workers as well as semiconductor devices. However, based on the precautionary principle, it may be necessary to continuously improve semiconductor processes and the work environment.

평판형 예혼합 버너의 다양한 화염면 매질 및 열교환기에 따른 연소 특성 (A Study on the Combustion Characteristics of Flat-Plate Premixed Burner for Various Flame Surface Media and Heat Exchangers)

  • 조은성;박창권;최경석
    • 대한기계학회논문집B
    • /
    • 제35권10호
    • /
    • pp.1033-1040
    • /
    • 2011
  • 예혼합 버너는 높은 효율과 낮은 배기 때문에 가정용 보일러 버너 시스템에 매우 강력한 버너이다. 일반적으로 가정용 보일러 버너는 내부에 농후한 예혼합 불꽃으로 구성하고 연료는 2차공기의 공급에 의하여 완전연소 되는 분젠 버너를 이용한다. 이것은 상대적으로 긴 불꽃 길이와 높은 과잉공기비에서 작동하기 때문에 높은 효율을 갖는 소형 보일러에 적용하기 어렵다. 이 논문에서 메탈 화이버, 세라믹, SUS 핀과 같은 매질을 사용하는 예혼합 연소 버너의 특징을 실험하였다. 특히, 표면 매질의 비반응 유동 특성은 버너 표면 전체의 유동 속도를 측정하고 조정하였다. 연소 실험은 화염 사진과 화염 온도 측정에 의하여 수행되었다. CO와 NO는 다양한 과잉 공기비와 열량값에 대하여 버너 표면 매질, 연소실, 열교환기의 특성을 측정하고 평가하였다.

전산유체역학을 이용한 단일 송풍기가 적용된 공냉식 연소설비의 효율개선 (Enhancement of combustion efficiency of a air-cooled combustor system with single F.D. Fan Using CFD)

  • 김민철;손병현;이재정;박흥석
    • 한국산학기술학회논문지
    • /
    • 제22권6호
    • /
    • pp.460-468
    • /
    • 2021
  • 본 연구는 multi fan 방식의 "공랭식 연소설비"의 공정관리상의 문제점을 single F.D. fan 으로 대체하여 개선시키기 위해 CFD 진행하였고, 연소로 내 유동조건 변화를 분석하여 문제점을 확인하였다. 이를 개선하기 위해 연소공기 주입구조를 변경하였고, 구조 변화에 따른 연소효율 개선을 수치해석으로 평가하였다. 또한 실제 연소설비에 수치해석결과를 반영하여 구조개선을 한 후 개선 전·후의 연소효율을 실험적으로 측정하였다. 먼저 기존 Single F.D fan 이 적용된 연소설비에 대한 수치해석을 통해, 2개의 유로로 공급되는 연소공기가 각 유로의 마찰력 차이와 압력의 변화로 인해 연소로 내에서 공급비율이 불규칙하게 되어 선회방식의 연소조건을 위한 축 형태의 난류형성이 어려움을 확인하였다. 이를 개선하기 위해서 연소로에 주입하는 공기 공급 방식을 두 가지로 나누어 수치해석을 하였다. 첫 번째 방식은 연소공기를 외벽에서 180 ~ 360° 회전 후 예열된 연소공기가 주입되는 구조에 대하여 검토하였고, 두 번째는 연소로 내에는 선회할 수 있는 베인(vane) 구조를 적용하여 연소로 밖에서 1차 열교환 후 연소로 내부에 접선방향으로 연소공기가 주입되는 구조에 대하여 검토하였다. 그 결과, single F.D. fan을 가진 공랭식 연소로에 선회방식으로 공기를 주입할 경우, 연소로 외벽의 냉각과 연소로 내부의 완전혼합 유지를 위해 이중 냉각벽을 가지는 덕트 구조를 적용하는 것이 연소조건을 최적화하는데 바람직한 것으로 나타났으며, 실제 운영중인 설비에 적용하여 개선 전·후의 연소효율을 비교한 결과 연소효율이 개선되는 것을 확인할 수 있었다.

증발을 이용한 방사성 액체폐기물의 처리와 피폭선량평가 (Treatment of Radioactive Liquid Waste Using Natural Evaporator and Resulted Exposure Dose Assessment)

  • 정경환;박승국;김은한;정기정;박현수
    • Journal of Radiation Protection and Research
    • /
    • 제24권2호
    • /
    • pp.101-108
    • /
    • 1999
  • 극저준위 방사성액체폐기물 처리를 위하여 공기의 온도와 습도 및 유입 공기의 속도에 따른 증발량의 관계를 천을 이용한 강제증발실험 장치로 실험하였다. 그 결과 각각의 변수와 증발량의 상관관계를 실험식으로 도출하였다. 또한 Cs-137 을 함유한 모의폐액을 사용하여 본 장치에 대한 제염 계수를 얻은 결과 $DF=10^4$으로 나타났다. TRlGA Mark II & III 연구용 원자로 폐로시 발생되는 극저준위 방사성액체폐기물을 증발장치로 처리할 때 주변의 일반개인에 대한 연간 피폭선량을 보수적으로 평가한 결과, 유효선량 (effective dose)은 $1.01{\times}10^{-3}mSv$이고, 환경으로 배출되는 공기의 방사능 농도(Cs-137)는 $4.637{\times}10^{-14}\;{\mu}Ci/cc$ air 이다. 따라서 극저준위 방사성액체폐기물의 처리를 위하여 강제증발장치를 사용하는 것은 주민에 아무런 영향이 없음을 알 수 있었다.

  • PDF

고온 공기 가열기 개발 현황 조사 및 고찰 (The Review and Investigation of High Temperature Heater Development)

  • 김정우;이정민
    • 한국추진공학회지
    • /
    • 제20권5호
    • /
    • pp.90-98
    • /
    • 2016
  • 극초음속 공기 흡입 추진기관의 지상 시험 시 추진기관의 고속 비행 조건을 모의하기 위해 고온 공기를 공급할 수 있는 고온 공기 가열기가 필요하다. 본 논문에서는 다양한 고온 가열기들을 조사하여 유형별로 정리하고, 장단점을 비교하였다. 가열기는 크게 유동장 내 연소 가열기, 아크 가열기, 축열식 가열기, 열교환식 가열기 4종류로 분류할 수 있었으며, 각각의 장단점이 다양하므로 목적에 맞게 가열기를 선정하여야 한다.

활어수조에서 넙치 사육시 포말분리장치를 이용한 오염물 제거 (Removal of Waste Generated by Flounder (Paralichthys olivaceus) in Aquarium using a Foam Separator)

  • 신정식;이창근;정호수;이민수;이진경;서근학
    • 한국수산과학회지
    • /
    • 제37권6호
    • /
    • pp.498-504
    • /
    • 2004
  • Removal of waste generated by Paralichthys olivaceus in the seawater aquarium using a foam separator was investigated. Protein concentration without a foam separator continuously increased until 3 days after stocking and reached at 25 mg/L after 5 days stocking, but protein concentration became lower than the initial protein concentration (2.5 mg/L) with a foam separator. The trends of other fish wastes such as ammonia, total suspended solids (TSS) and chemical oxygen demand (COD) were similar to protein. Dissolved oxygen (DO) in the aquarium decreased below 6.0 mg/L without a foam separator, but with a foam separator the average DO in the aquarium was 7.3 mg/L. Foam separation with the increase of superficial air velocity (SAV) was more effective than that with the fixed SAV. This study showed that wastewater. treatment of seawater aquarium using a foam separator is effective method for a fish waste removal and oxygen supply.