• 제목/요약/키워드: Supply Temperature

검색결과 1,811건 처리시간 0.03초

냉동기에 의해 냉각되는 복사열차폐 최적설계 (Design Optimization of Thermal Radiation Shield Cooled by Cryocooler)

  • 최연석;;김동락;양형석;이병섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2171-2174
    • /
    • 2008
  • The design of thermal radiation shield cooled by a cryocooler is presented. This study is motivated mainly by our recent development of prototype superconducting magnet system for the Cyclotron K120. The superconducting magnet system is composed of the magnet cryostat, transfer line and supply cryostat. In order to minimize thermal radiation load, the superconducting coil form in the magnet cryostat is enclosed by the thermal radiation shield which is thermally connected to the first-stage cold head of a two-stage cryocooler in the supply cryostat. Since the supply cryostat is located far from the magnet cryostat large temperature gradient along the thermal shield is unavoidable. In this paper, the thermal radiation shield is optimized to minimize temperature gradient with taking into account the cryogenic load, system structure and electrical load. The effect of heat source from thermal conduction through mechanical supports on the temperature distribution of thermal radiation shield is also discussed.

  • PDF

A Nano-power Switched-capacitor Voltage Reference Using MOS Body Effect for Applications in Subthreshold LSI

  • Zhang, Hao;Huang, Meng-Shu;Zhang, Yi-Meng;Yoshihara, Tsutomu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권1호
    • /
    • pp.70-82
    • /
    • 2014
  • A nano-power CMOS voltage reference is proposed in this paper. Through a combination of switched-capacitor technology with the body effect in MOSFETs, the output voltage is defined as the difference between two gate-source voltages using only a single PMOS transistor operated in the subthreshold region, which has low sensitivity to the temperature and supply voltage. A low output, which breaks the threshold restriction, is produced without any subdivision of the components, and flexible trimming capability can be achieved with a composite transistor, such that the chip area is saved. The chip is implemented in $0.18{\mu}m$ standard CMOS technology. Measurements show that the output voltage is approximately 123.3 mV, the temperature coefficient is $17.6ppm/^{\circ}C$, and the line sensitivity is 0.15 %/V. When the supply voltage is 1 V, the supply current is less than 90 nA at room temperature. The area occupation is approximately $0.03mm^2$.

외기냉방시스템이 적용된 데이터센터 CRAH의 급기온도와 설계 풍량에 따른 에너지성능 분석 (Energy Performance of Air-side Economizer System for Data Center Considering Supply Temperature and Design Airflow Rate of CRAH(Computer Room Air Handler))

  • 김지혜;엄태윤;정차수
    • 대한건축학회논문집:구조계
    • /
    • 제35권11호
    • /
    • pp.181-188
    • /
    • 2019
  • The purpose of this study is to evaluate the cooling energy saving effects of CRAH supply air temperature(SAT) and design flow rate changes when applying air-side economizer in the data center. MLC(Mechanical Load Component), which is cooling performance indicator of data center, was used to assess the effectiveness of cooling energy savings. It was computed with energy simulation (DesignBuilder) to evaluate the cooling energy performance of 8 different alternatives in a data center. The MLC was 0.31~0.32 regardless of CRAH supply temperature without air-side economizer, and 0.15 to 0.19 value with air-side economizer. That is, cooling energy can be reduced by approximately 40~55% when applying economizer. As the CRAH SAT and design flow rate changed, the MLC values were 0.16 to 0.18 and 0.15 to 0.19, respectively.

자연순환형 태양열 온수기 축열조의 압력식 설계 개조 (Design Modification of a Thermal Storage Tank of Natural-Circulation Solar Water Heater for a Pressurized System)

  • 부준홍;정의국
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.45-54
    • /
    • 2007
  • For a conventional natural-circulation type solar water heater, the pressure head is limited by the height between the storage tank and hot water tap. Therefore, it is difficult to provide sufficient hot water flow rate for general usage. This study deals with a design modification of the storage tank to utilize the tap-water pressure to increase hot-water supply Based on fluid dynamic and heat transfer theories, a series of modeling and simulation is conducted to achieve practical design requirements. An experimental setup is built and tested and the results are compared with theoretical simulation model. The storage tank capacity is 240 l and the outer diameter of piping was 15 mm. Number of tube turns tested are 5, 10, and 15. Starting with initial storage tank temperature of $80^{\circ}C$, the temperature variation of the supply hot water is investigated against time, while maintaining minimum flow rate of 10 1/min. Typical results show that the hot water supply of minimum $30^{\circ}C$ can be maintained for 34 min with tap-water supply pressure of 2.5 atm, The relative errors between modeling and experiments coincide well within 10% in most cases.

천연가스 수송을 위한 Gas Hydrate Supply Chain의 경제성 분석 (Gas Hydrate Supply Chain analyses of economy for the natural gas transportation)

  • 김철호;이재익;정태석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.151.1-151.1
    • /
    • 2010
  • Natural gas hydrates (NGH) provide 170 gas volumes per unit volume of the medium and are easier to make with moderate pressure and temperature (40 bar at 3 C). Once they form, their preservation temperature is 20 C at 1 bar, which is much milder than the LNG preservation. In case of using the NGH, The small and medium sized gas well has advantages for development because of NGH's these characteristics. According to the cost evaluation report of Gudmundsson in Norway and the research of MES in Japan, the gas well that uses the NGH has a cost saving effect about 10~20% compared LNG. The effect depends on distance and production. However, cost saving and efficiency of liquefaction process is increased by the development of LNG liquefaction technology. Therefore, these factors have to be reflected in economic analysis. The purpose of this research is to compare the cost of Gas Supply Chain according to the transport type, distance and gas reserves. Especially, we consider not only the cost of facility but also the total cost (production cost, transport cost, etc).

  • PDF

핀-튜브 열교환기에서의 습증기 발생 메커니즘의 파악을 위한 실험적 연구 (An Experimental Study on Understanding of Production Mechanism of a Mist from Fin-Tube Heat Exchanger)

  • 박상균;윤석훈;김경근;김명환;오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.595-604
    • /
    • 2001
  • As an improvement in the standard of living and economic growth, the demand for air conditioning equipment is increasing rapidly. Nowadays, air conditioning equipments are being used for industry, large building, house and car. There equipments were concentrated on improving heat efficiency of economic aspects while thy design heat exchanger for cooling and heating. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore, the user demand air of high class and quality. In this experimental study, to acquire elementary data for development of heat exchanger which be able to supply air of high quality, that is to say, possess a restraint effect of mist generation. We estimate an effect on cooling plate quality, supply air velocity, supply air temperature, cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

태양열 온수 및 난방 일체형 복합시스템의 성능예측 (Performance Prediction of a Hot Water Supply and Panel Heating System with Solar Energy)

  • 한유리;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.11-17
    • /
    • 2012
  • In this study, a simulation program was developed with heat transfer model in the thermal storage tank for a solar collector and burner combined heating and hot water supply system. Analysis was conducted with variation of operating condition and schedule to analyze performance of a hot water supply and panel heating system with a solar collector and burner combined thermal storage tank. The simulation program is divided two sections. One part is calculation of temperature variation of water which flows through the panel in the floor for heating of the residential house during 24 hours, and the other part is heat transfer calculation for the reaction time to get desired water temperature in the thermal storage tank. As results, light oil consumption and system performance during operation period were analyzed with variation of climate condition and with or without solar collector. Most of the case, oil could be saved about from 24 to 41% with installing the solar collector. The performance of the system is more dependent on radiation time of the solar collector rather than the intensity of the solar radiation which was adopted for the climate analysis.

지능형 반도체 세정장비 설계에 관한 연구 (A Study on Design of Intelligent Wet Station for Semiconductor)

  • 김종원;홍광진;조현찬;김광선;김두용;조중근
    • 반도체디스플레이기술학회지
    • /
    • 제4권3호
    • /
    • pp.29-33
    • /
    • 2005
  • As the integrated devices become more and more sophistcated, the diameter of wafers increased up to 300 mm and strict level of cleaning is necessary to remove the particulates on the surface of wafer. Therefore we need a new type of wet-station which can reduce DI water and chemical in the cleaning process. Moreover, it is important to control the temperature and the concentration of chemical in the wet-station. In the conventional chemical supply system, it is difficult not only to fit the mixing rate of chemicals in cleaning process, but also to fit the quantity and temperature. Thus, we propose a new chemicals supply system, which overcomes above problems by the analysis of fluid and thermal transfer on chemical supply system.

  • PDF

200 t/d급 MHI 석탄 가스화기의 석탄 및 공기 배분에 따른 가스화 특성 평가 (Influence of coal and air flow rate distribution on gasification characteristics in 200 t/d scale MHI coal gasifier)

  • 도윤영;예인수;김봉근;류창국
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.93-96
    • /
    • 2015
  • Commercial coal gasifiers typically use entrained flow type reactors, but have unique features in terms of reactor shape, gasifying agent, coal feeding type, ash/slag discharge, and reaction stages. The MHI gasifier is characterized as air-blow dry-feed entrained reactor, which incorporates a short combustion stage at the bottom and a tall gasification stage above. This study investigates the flow and reaction characteristics inside a MHI gasifier by using computational fluid dynamics (CFD) in order to understand its design and operation features. For its pilot-scale system at 200 ton/day capacity, the distribution of coal and air supply between the two reaction stages was varied. It was found that the syngas composition and carbon conversion rate were not significantly influenced by the changes in the distribution of coal and air supply. However, the temperature, velocity and flow pattern changed sensitively to the changes in the distribution of coal and air supply. The results suggest that one key factor to determine the operational ranges of coal and air supply would be the temperature and flow pattern along the narrower wall between the two reaction stages.

  • PDF

피크전류모드 제어를 적용한 고주파 심부발열 전원장치 설계 (Design of High Frequency Heating Power Supply System Using Peck Current Mode Control)

  • 허국성;정도;박성욱;구위경;김희제
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.61-65
    • /
    • 2017
  • In this paper a prototype of high frequency heating power supply system based on the high frequency heating principle is designed to take the place of acupuncture, moxibustion, warm dressing treatment and some other traditional physical therapy methods. Which possess the advantages of low cost, convenient, easy operation and good effect. The high frequency heating power supply can generate a pulse voltage of more than 1KV with 300KHz switching frequency to heat the patient's skin. The skin temperature can reach to $41{\sim}42^{\circ}C$. The peak current control method is used to maintain the skin temperature in the designed range. The design of the main circuit is based on the flyback converter topology. An easier and practical design method is proposed in this paper. The power supply system prototype is verified to be stable and reliable by both the simulation and experimental results.