• Title/Summary/Keyword: Supersonic ejector

Search Result 67, Processing Time 0.025 seconds

A NUMERICAL STUDIES ON THE FLOW PROPERTIES OF AXI-SYMMETRIC ANNULAR BELL TYPE EJECTOR-JETS (축대칭 환형 분사식 이젝터 제트 유동 특성의 수치적 연구)

  • Park, G.H.;Kwon, S.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.185-188
    • /
    • 2006
  • An investigation of the ejector-jets focusing on its flow properties was carried out by varying the geometric parameters. The area ratio of the primary nozzle, AR that was tested in the present measurement was 2.17 and 3.18, while the ratio of the length to the diameter of the duct downstream the primary nozzle inlet, L/D had values of 3.41, 6.82, and 10.23. For the frame work of flow characteristics, the wall pressures distribution of ejector-jet was investigated by experiment for basic study of ejector-jet performance. In result, terminal shock location and existence of series of oblique shocks are recognized. In this study, CFD analysis was conducted at the same time. And as a result of comparison experiment data with CFD analysis, the physical phenomena of ejector-jets were estimated.

  • PDF

INTERNAL FLOW PROPERTIES AND THRUST CHARACTERISTICS OF AXI-SYMMETRIC ANNULAR BELL TYPE EJECTOR-JET (축대칭 환형 이젝터 제트의 내부 유동과 추력특성)

  • Park, G.H.;Kwon, S.J.
    • Journal of computational fluids engineering
    • /
    • v.12 no.2
    • /
    • pp.46-52
    • /
    • 2007
  • An experimental and numerical investigation of the ejector-jets focusing on its geometric parameters that effect on thrust performance was carried out. The area ratio of the primary nozzle that was tested in the present study was 2.17 and 3.18, while the ratio of the length to the diameter of the duct downstream the primary nozzle inlet had values of 3.41, 6.82, and 10.23. Internal flow properties of ejector-jet were estimated by comparison experiment data and CFD analysis for basic study of ejector-jet thrust performance. For examination of thrust performance, the thrust ratios increased with increase in L/D. Especially at AR=2.17, the maximum thrust augmentation was 33 percent for the shortest L/D. It is expected that the increase of mixing duct length of ejector-jet will be helpful in a thrust performance by improving mixing efficiency.

INTERNAL FLOW PROPERTIES AND THRUST CHARACTERISTICS OF AXI-SYMMETRIC ANNULAR BELL TYPE EJECTOR-JET (축대칭 환형 이젝터 제트의 내부 유동과 추력특성)

  • Park, G.H.;Kwon, S.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.166-170
    • /
    • 2007
  • An experimental and numerical investigation of the ejector-jets focusing on its geometric parameters that effect on thrust performance was carried out. The area ratio of the primary nozzle that was tested in the present studywas 2.17 and 3.18, while the ratio of the length to the diameter of the duct downstream the primary nozzle inlet had values of 3.41, 6.82, and 10.23. Internal flow properties of ejector-jet were estimated by comparison experiment data and CFD analysis for basic study of ejector-jet thrust performance. For examination of thrust performance, the thrust ratios increased with increase in L/D. Especially at AR=2.17, the maximum thrust augmentation was 34 percent for the shortest L/D. It is expected that the increase of mixing duct length of ejector-jet will be helpful in a thrust performance by improving mixing efficiency.

  • PDF

Steady and Unsteady Operating Characteristics of Supersonic Exhaust Diffuser for Altitude Simulation (고도모사용 초음속디퓨져의 정상 및 천이작동특성)

  • Park, Byung-Hoon;Ki, Wan-Do;Lim, Ji-Hwan;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.344-352
    • /
    • 2006
  • Evacuation performance, starting transient, and plume blowback at diffuser breakdown of a straight cylindrical supersonic exhaust diffuser with no externally supplied secondary flow are investigated. Pressure records in the transitional periods are measured by a small-scale cold-gas simulator. Flow-fields evolving in the diffuser-type ejector are solved by preconditioned Favre-averaged Navier-Stokes equations with a low-Reynolds number $k-{\varepsilon}$ turbulence model edited for turbulence compressibility effects. The present RANS method is properly validated with measured static wall pressure distributions and evacuation level at steady operation as well as the pressure records during the transition regime.

  • PDF

An Experimental Study of the Subsonic/Supersonic Steam Ejectors (아음속/초음속 증기 이젝터에 관한 실험적 연구)

  • 최보규;김희동;이준희;김덕줄
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.1-8
    • /
    • 2000
  • For the purpose of a cost effective design of practical subsoni $c^ersonic ejector systems, an experiment was carried out using a superheated steam as a primary driving flow. The superheated steam jet was produced by several different kinds of subsonic and supersonic nozzles. The secondary flow of atmospheric air inside a plenum chamber was drawn into the primary steam jet. The vacuum performance of the plenum chamber was investigated for a wide range of the ejector operation pressure ratio. The result showed that the static pressure of the mixed flow at the ejector throat is only a function of the ejector operation pressure ratio, regardless of the primary nozzle type employed.ed.

  • PDF

Preliminary Design of a High Altitude Test Facility using a Secondary Throat Exhaust Diffuser and an Ejector (이차목 디퓨저와 이젝터를 사용한 고공환경모사장치 예비설계)

  • Kim, Joong-Il;Jeon, Jun-Su;Kim, Tae-Wan;Ko, Young-Sung;Kim, Sun-Jin;Kim, Yoo;Han, Yeoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.475-478
    • /
    • 2012
  • In this study, preliminary design of a high-altitude test facility (HATF) was performed to simulate the high-altitude environment using a rocket engine that liquid oxygen and kerosene were used as the propellant. Experimental facility consists of vacuum chamber, supersonic exhaust diffuser, heat exchanger, ejector and gas generator. The vacuum chamber was simulated and maintained high-altitude environmental pressure by supersonic exhaust diffuser. Combustion gas of the rocket engine was cooled by water at heat exchanger after that the mixed gas was emitted to the air by ejector. The ejector which was operated by the steam generator using 75% ethanol and liquid oxygen as propellants and water for steam maintains a vacuum condition.

  • PDF

The Starting Characteristics of the Steady Ejector-Diffuser System

  • Gopalapillai, Rajesh;Kim, Heuy-Dong;Matsuo, Shigeru;Setoguchi, Toshiaki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.680-685
    • /
    • 2008
  • The ejector is a simple device which can transport a low-pressure secondary flow by using a high-pressure primary flow. In general, it consists of a primary driving nozzle, a mixing section, and a diffuser. The ejector system entrains the secondary flow through a shear action generated by the primary jet. Until now, a large number of researches have been made to design and evaluate the ejector systems, where it is assumed that the ejector system has an infinite secondary chamber which can supply mass infinitely. However, in almost all of the practical applications, the ejector system has a finite secondary chamber implying steady flow can be possible only after the flow inside ejector has reached an equilibrium state after the starting process. To the authors' best knowledge, there are no reports on the starting characteristics of the ejector systems and none of the works to date discloses the detailed flow process until the secondary chamber flow reaches an equilibrium state. The objective of the present study is to investigate the starting process of an ejector-diffuser system. The present study is also planned to identify the operating range of ejector-diffuser systems where the steady flow assumption can be applied without uncertainty. The results obtained show that the one and only condition in which an infinite mass entrainment is possible is the generation of a recirculation zone near the primary nozzle exit. The flow in the secondary chamber attains a state of dynamic equilibrium at this point.

  • PDF

A Study of the Supersonic Free Jet Discharging from a Petal Nozzle (Petal 노즐로부터 방출되는 초음속 자유제트 유동에 관한 연구)

  • Lee Jun-Hee;Kim Jung-Bae;Kim Heuy-Dong
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.109-112
    • /
    • 2002
  • The supersonic jet discharging from a petal nozzle is known to enhance mixing effect with the surrounding gas because it produces strong longitudinal vortices due to the velocity difference from both the major and minor axes of petal nozzle. In the present study, the supersonic free jet discharging from the petal nozzle is investigated experimentally. The nozzles used are 4, 6, and 8 lobed petal nozzles with a design Mach number of 1.7, and the flow fields are compared with a circular nozzle with the same design Mach number. The pitot impact pressures are measured using a fine pilot probe. The flow fields are visualized using a Schlieren optical method. The results show that the petal nozzle has more increased supersonic length compared with the circular jet.

  • PDF

An Experimental Study on the Supersonic Petal Ejector-Diffuser System (초음속 페탈이젝터-디퓨저 시스템에 관한 실험적 연구)

  • 이준희;김중배;최보규;김희동
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.19-22
    • /
    • 2003
  • Ejector-diffuser system is one of fluid machinery which can entrain the fluid in low pressure part and transport it to the higher pressure part. The conventional ejector-diffuser system has been pointed out that its overall efficiency is quite low compared with other fluid machinery since it is derived by only the pure shear stresses. In the present study, 4, 6, and 8 lobed petal nozzles with a design Mach number of 1.7 are adopted as a primary nozzle to improve the performance, and are compared with a conventional circular nozzle.

  • PDF