• 제목/요약/키워드: Superheating

검색결과 63건 처리시간 0.026초

초저온 케스케이드 냉동사이클의 중간압력 및 바이패스 유량 최적화 (Optimization of Middle Pressure and Bypass Mass Flow Rate in Cryogenic Refrigeration Cascade Cycle)

  • 오승택;최원재;이호생;윤정인;유선일;최건형;이상규
    • 동력기계공학회지
    • /
    • 제14권2호
    • /
    • pp.28-33
    • /
    • 2010
  • In this research, cascade liquefaction process was simulated using two-staged direct expansion with inter-cooler. Evaporated gaseous refrigerant which has low pressure and temperature from the inter-cooler is mixed with gaseous refrigerant from outlet of 1st compressor, and flows into 2nd compressor. Therefore this prevents superheating compression. Compressor work of process which includes inter-cooler to all cycles shows the lowest value of 338.68 MW and it is lower 16.34% than that of basic process. Refrigeration capacity shows decreasing tendency as applied inter-cooler and that of process which includes inter-cooler to all cycles shows the lowest value of 449 MW. COP was increased when the inter-cooler was applied, and process which includes inter-cooler to all cycles shows highest value of 1.33. It shows that COP was increased because decrement of compressor work by applying inter-cooler was higher than decrement of refrigeration capacity.

저온용 대체냉매의 성능 특성 연구 (Performance Characteristics Study on an Alternative Refrigerant in Low Temperature Applications)

  • 신정섭;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제27권4호
    • /
    • pp.462-469
    • /
    • 2016
  • This paper presents the results of thermodynamic cycle analysis and performance tests of alternative mixtures in low temperature applications. Two near-azeotropic binary mixtures R-152a/R-1270 (35:65 by wt.%) and R-290/E170 (35:65 by wt.%) are considered in this study. They have zero ODP (Ozone Depletion Potential) and much lower GWP (Global Warming Potential) than R-404A which is an alternative of R-502. Refrigeration cycle characteristics such as cooling capacity, coefficient of performance, suction and discharge pressures and temperatures are compared to those for the baseline refrigerants (R-502 and R-404A) cycles. The performance tests are conducted at the evaporation and condensation temperatures of $5^{\circ}C$ and $45^{\circ}C$, subcooling and superheating temperatures of $5^{\circ}C$, respectively. Performance comparisons between baseline and alternative refrigerants are conducted on the same cooling capacity. The system performance of newly proposed refrigerant mixtures show promising results.

Al/액체연료 슬러리 액적의 연소와 (1)-실험적 연구- (Combustion and Microexplosion of Al/Liquid Fuel Slurry Droplets(I)-Ewperimental Study-)

  • 변도영;조주형;안국영;백승욱
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1576-1585
    • /
    • 1997
  • The microexplosive combustion of a slurry droplet was investigated experimentally. The microexplosion has been approximately considered to be caused by pressure build-up in the shell and to be promoted by heterogeneous nucleation of liquid carrier, which is due to the suppression of evaporation and subsequent superheating of liquid carrier. To closely investigate the pressure build-up and the heterogeneous nucleation, the experiments were conducted in an electric combustor, of which temperature was controllable (400 K-900 K). And the effects of two aligned droplets on the interactive combustion and microexplosion were found in a hot post region of a flat flame burner. Transient internal temperature distributions for slurry droplets were measured. And the shell formation and the microexplosion of suspended A1/JP-8 and Al/n-heptane slurry droplets were examined with various surfactant concentrations (0.5-5 wt%) and solid loadings (10-50 wt.%). The microexplosion time of binary array of droplets was found to be less than that of the isolated droplet due to radiative interaction between droplets.

마이크로파에 의한 생분해성 β-TCP/PLGA 복합체의 제조시 β-TCP 첨가량에 따른 영향 (The Influence of β-TCP Content on the Preparation of Biodegradable β-TCP/PLGA Composites Using Microwave Energy)

  • 진형호;민상호;박홍채;윤석영
    • 한국재료학회지
    • /
    • 제16권1호
    • /
    • pp.1-4
    • /
    • 2006
  • Biodegradable $\beta$-tricalcium phosphate ( $\beta$-TCP)/poly(lactide-co-glycolide) (PLGA) composites were synthesized by in-situ polymerization with microwave energy. The influence of the $\beta$-TCP content in $\beta$-TCP/PLGA composites on the molecular weight, crystallinity, microstructure and mechanical properties was investigated. As the molecular weight of composites decreased, the $\beta$-TCP content increased up to 10 wt.%, while the excess addition of the $\beta$-TCP content above 10 wt.% the molecular weight increased with increasing of the $\beta$-TCP content. This behavior would be due to the superheating effect or nonthermal effect induced by microwave energy. It was found that the bending strength and Young's modulus of the $\beta$-TCP/PLGA composites was proportional to the molecular weight of PLGA. The bending strength of the $\beta$-TCP/PLGA composites ranged from 18 to 38 MPa, while Young's modulus was in the range from 2 to 6 GPa.

수직냉각관내에서 상변화물질의 응고에 관한 실험적 연구 (An Experimental Study on Freezing of Phase Change Material in a Cooled Vertical Tube)

  • 이재목;이채문;임장순
    • 대한설비공학회지:설비저널
    • /
    • 제13권4호
    • /
    • pp.223-229
    • /
    • 1984
  • Experiments were performed for freezing of an initially superheated or nonsuperheated liquid phase in a cooled vertical tube. The liquid was placed in a copper tube whose surface maintained a uniform temperature during the data run and the freezing occurred in a copper tube. The phase change medium was n-odtadecane, a paraffin which freezes at about $61^{\circ}C$. Measurements were made which yielded information about the time dependence of the freezing front, of the amount of frozen mass, and of the various energy components extracted from the tube. The time-wise decay of the initial liquid superheat was also measured. Initial superheat of the liquid tends to moderately diminish the rozen mass and associated latent energy extraction at small times but has lit tie effect on these quantities at large tiems. Natural convection in the liquid Plays a modest role only at small times and disappears when the superheat decay to zero. Although the latent energy constitutes the largest contributor to the total extracted energy, the sensible energy components can make a significant contribution, especially at large tube wall subcoolings, large initial liquid superheating and short freezing time.

  • PDF

Characteristics of debris resulting from simulated molten fuel coolant interactions in SFRS

  • E. Hemanth Rao;Prabhat Kumar Shukla;D. Ponraju;B. Venkatraman
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.283-291
    • /
    • 2024
  • Sodium cooled Fast Reactors (SFR) are built with several engineered safety features and hence a severe accident such as a core melt accident is hypothetical with a probability of <10-6/ry. However, in case of such accidents, the mixture of the molten fuel and structural materials interacts with sodium. This phenomenon is known as Molten Fuel Coolant Interaction (MFCI) and results in fragmentation of the melt due to various instabilities. The fragmented particles settle as a debris bed on the core catcher at the bottom of the reactor vessel, and continue to generate decay heat. Characteristics of the debris particles play a vital role in heat transfer from the bed and need thorough investigation. The size, shape, and physical state of the debris depend on the associated fragmentation mechanism, superheating of the melt, and sodium temperature. Experiments have been conducted by releasing simulated corium, a molten mixture of alumina and iron generated by the aluminothermy process at ~2400 ℃ into liquid sodium, to study the fragmentation phenomena. After the experiment, the fragmented debris was retrieved and the particle size distribution was determined by sieve analysis. The debris was subjected to microscopic investigation for obtaining morphological characteristics. Based on the characteristics of debris, an attempt has been made to assess of fragmentation mechanism of simulated corium in sodium.

R744-R404A용 캐스케이드 냉동시스템의 엑서지 분석 (Exergy Analysis of R744-R404A Cascade Refrigeration System)

  • 오후규;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1001-1008
    • /
    • 2011
  • 본 논문은 내부 열교환기를 가지는 R744와 R404A용 캐스케이드 냉동시스템의 운전변수에 대한 최적의 설계를 위해서 냉동장치의 성능과 엑서지를 이론적으로 분석하였다. 본 연구에서 고려된 작동변수로는 과열도와 과냉각도, 내부 열교환기와 압축기 효율, 증발 및 응축온도 등이다. 분석한 결과를 요약하면 다음과 같다. 캐스케이드 증발온도가 증가할수록 R404A용 고온사이클의 COP는 증가하는 반면에, R744용 저온사이클의 COP는 감소한다. 따라서 이러한 이유로 전체 캐스케이드 냉동사이클의 COP는 거의 일정하다. 또한 캐스케이드 증발온도가 증가할수록 R404A용 응축기와 압축기의 엑서지 손실이 가장 큰 것을 알 수 있다. 따라서 R744와 R404A용 캐스케이드 냉동시스템의 COP 향상을 위해서는 R404용 응축기와 압축이의 엑서지 손실을 줄여야만 한다.

R744를 2차냉매로 사용하는 R404A용 냉동시스템의 성능 분석 (Performance analysis of R404A refrigeration system using R744 as secondary refrigerant)

  • 오후규;손창효
    • 동력기계공학회지
    • /
    • 제16권2호
    • /
    • pp.24-29
    • /
    • 2012
  • In this paper, an analysis on performance and exergy of R404A refrigeration system using R744 secondary refrigerant was performed numerically to optimize the design for the operating parameters. The operating parameters considered in this study include subcooling and superheating degree, internal heat exchanger and compression efficiency, evaporation and condensation temperature in the R404A refrigeration cycle and temperature difference of cascade heat exchanger. The main results are summarized as follows : The COP(coefficient of performance) of R404A refrigeration system increases with increasing evaporation temperature. The evaporation capacity of R744 as secondary refrigerant increases with the increase in evaporation pressure of R744 secondary refrigeration. And the enthalpy in the evaporator outlet of R744 increases with the increasing evaporation pressure of R744 secondary refrigeration. Therefore, it is important to analysis for the relationship between COP of R404A refrigeration system and refrigeration capacity of R744. As cascade evaporation temperature increase, the exergy loss of condenser and compressor using R404A is the largest among all components. Therefore, the exergy loss in the condenser and compressor using R404A must be decreased to enhance the COP of R404A refrigeration system with R744 secondary refrigerant.

저온 열원으로부터 최대 동력을 생산하기 위한 유기랭킨사이클(ORC)에 관한 연구 (Study on Organic Rankine Cycle (ORC) for Maximum Power Extraction from Low-Temperature Energy Source)

  • 김경훈;한철호;김기만
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.73-79
    • /
    • 2011
  • ORC(organic Rankine cycle) has potential of reducing consumption of fossil fuels and has many favorable characteristics to exploit low-temperature heat sources. This work analyzes performance of ORC with superheating using low-temperature energy sources in the form of sensible energy. Maximum mass flow rate of a working fluid relative to that of a source fluid is considerd to extract maximum power from the sources. Working fluids of R134a, $iC_4H_{10}$ and $C_6C_6$, and source temperatures of $120^{\circ}C$, $200^{\circ}C$ and $300^{\circ}C$ are considered in this work. Results show that for a fixed source temperature thermal efficiency increases with evaporating temperaure, however net work per unit mass of source fluid has a maximum with respect to the evaporating temperature in the range of low source temperature. Results also show that the maximum power extraction is possible with R134a for the source temperature of $120^{\circ}C$, with $iC_4H_{10}$ for $200^{\circ}C$, and with $C_6C_6$ for $300^{\circ}C$.

온배수와 표층수를 이용하는 R134a용 유기 랭킨사이클의 성능 비교 (Performance Comparison of R134a Organic Rankine Cycle (ORC) Using Hot Wastewater and Surface Seawater)

  • 윤정인;손창효;백승문;김현주;이호생
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권6호
    • /
    • pp.768-773
    • /
    • 2012
  • 유기 랭킨사이클의 증발기 2차 유체로서 화력발전소에서 버려지는 $35^{\circ}C$의 온배수를 이용하는 경우와 $25^{\circ}C$의 해양 표층수를 이용하는 경우의 사이클 특성을 서로 비교한 후, 유기 랭킨사이클에 화력발전소에서 버려지는 온배수를 유기 랭킨 사이클에 적용 가능한지를 확인 하였다. 본 연구에서 고려된 작동변수는 과열도, 과냉각도, 터빈효율, 펌프효율 등이다. 주요 결과를 요약하면 다음과 같다. 화력발전소에 배출되는 $35^{\circ}C$의 온배수를 적용한 유기 랭킨사이클의 효율이 $25^{\circ}C$의 표층수를 적용한 유기 랭킨사이클에 비해 87% 이상 높게 나타났다. 따라서 화력발전소의 온배수를 유기 랭킨사이클에 적용할 수 있음을 확인할 수 있었다.