• Title/Summary/Keyword: Superficial inferior epigastric artery based flap

Search Result 4, Processing Time 0.02 seconds

An Algorithmic Approach to Total Breast Reconstruction with Free Tissue Transfer

  • Yu, Seong Cheol;Kleiber, Grant M.;Song, David H.
    • Archives of Plastic Surgery
    • /
    • v.40 no.3
    • /
    • pp.173-180
    • /
    • 2013
  • As microvascular techniques continue to improve, perforator flap free tissue transfer is now the gold standard for autologous breast reconstruction. Various options are available for breast reconstruction with autologous tissue. These include the free transverse rectus abdominis myocutaneous (TRAM) flap, deep inferior epigastric perforator flap, superficial inferior epigastric artery flap, superior gluteal artery perforator flap, and transverse/vertical upper gracilis flap. In addition, pedicled flaps can be very successful in the right hands and the right patient, such as the pedicled TRAM flap, latissimus dorsi flap, and thoracodorsal artery perforator. Each flap comes with its own advantages and disadvantages related to tissue properties and donor-site morbidity. Currently, the problem is how to determine the most appropriate flap for a particular patient among those potential candidates. Based on a thorough review of the literature and accumulated experiences in the author's institution, this article provides a logical approach to autologous breast reconstruction. The algorithms presented here can be helpful to customize breast reconstruction to individual patient needs.

Twisting Effect on Supermicroanastomosis of the Superficial Inferior Epigastric Artery in a Rat Model (혈관 비틀림이 백서 천층하복부 동맥의 초미세문합에 미치는 효과)

  • Seo, Mi-Hyun;Kim, Soung-Min;Eo, Mi-Young;Kang, Ji-Young;Myoung, Hoon;Lee, Jong-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.5
    • /
    • pp.375-384
    • /
    • 2011
  • Purpose: The advent of microsurgical technique and instruments, particularly in the field of perforator flap and supermicrosurgery, which have expanded the scope of microsurgery. However, supermicroanastomosis without any compression, tension, or distortions must be achieved to reach successful outcomes. Small-caliber vessels, such as those with an internal diameter less than 0.2 mm, are susceptible to inadvertent twisting of the anastomosis. In this study, using the superficial inferior epigastric artery (SIEA)-based flap model in Sprague-Dawley (SD) rats, we evaluated the acceptable limits of twisting effects on supermicroanastomotic sites. Methods: A total of 20 supermicroanastomoses were performed using the SIEA-based flap model in 10 male SD rats, 10-weeks-of-age, weighing 300~350 g. Rats were divided into five groups of two with four flaps as follows: 1) sham, 2) control group with end to end SIEA arterial supermicroanastomosis, 3) experimental I (EA1) with $90^{\circ}$ twisting, 4) experimental II (EA2) with $180^{\circ}$ twisting, and 5) experimental III (EA3) with $270^{\circ}$ twisting of the supermicroanastomosis. Each SIEA was anastomosed using six 11-0 $Ethilon^{(R)}$ (Ethicon Inc. Co., NJ, USA) stitches except in the sham group where the SIEA was only clamped with Supermicro vascular $clamps^{(R)}$ (S&T, Neuhausen, Switzerland) for 20 minutes. Results: The anastomosed arterial patency showed no remarkable changes according to doppler waveforms measured with a Smardop 45 Doppler System (Hadeco Inc., Kawasaki, Japan). The pulsatility index (PI) was increased at postoperative day 10 in the EA2 and EA3 groups, and the resistance index (RI) showed no statistically significant difference between preoperative and postoperative values at 10 days. Histologic specimens from the EA3 group showed increased tunica media necrosis, convolution of the internal elastic lamina, densely packed platelets, fibrin, and erythrocytes. Flap viability and anastomosed vessel patency were not significantly affected by the degree of arterial twisting in this study, other than in the EA3 group where minor effects on arterial patency of the microanastomoses were encountered. Conclusion: It appears that minor twisting on small caliber arteries, used in supermicroanastomoses, can be tolerated. However, twisting should be avoided as much as possible, and more than $180^{\circ}$ twisting must be prevented in clinical practice.

The Impact of Abdominal Liposuction on Abdominally Based Autologous Breast Reconstruction: A Systematic Review

  • Bond, Evalina S.;Soteropulos, Carol E.;Poore, Samuel O.
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.324-331
    • /
    • 2022
  • Prior abdominal liposuction can be viewed as a relative or absolute contraindication to abdominally based autologous breast reconstruction given concerns for damaged perforators and scarring complicating intraoperative dissection. This systematic review aims to explore the outcomes of abdominally based breast reconstruction in patients with a history of abdominal liposuction. A Preferred Reporting Items for Systematic Reviews and Meta-Analyses-guided literature search was conducted using PubMed, Scopus, and Web of Science from the earliest available date through June 2020. Deep inferior epigastric perforator, muscle-sparing transverse rectus abdominis musculocutaneous (TRAM), superficial inferior epigastric artery, and pedicled TRAM flaps were included for evaluation. Complications included total or partial flap loss, fat necrosis, seroma, delayed wound healing, and donor site complications. After inclusion criteria were applied, 336 non-duplicate articles were screened, yielding 11 for final review, representing 55 flaps in 43 patients. There was no instance of total flap loss, eight (14.5%) flaps developed partial loss or fat necrosis, three (5.4%) flaps had delayed wound healing, and two (4.6%) patients had donor site complications. Most authors (8/11) utilized some type of preoperative imaging. Doppler ultrasonography was the most used modality, and these patients had the lowest rate of partial flap loss or flap fat necrosis (8%), followed by those without any preoperative imaging (10%). In conclusion, this review supports that patients undergoing abdominally based autologous breast reconstruction with a history of abdominal liposuction are not at an increased risk of flap or donor site complications. Although preoperative imaging was common, it did not reliably decrease complications. Further prospective studies are needed to address the role of imaging in improving outcomes.

Assessment of Tissue Perfusion Following Conventional Liposuction of Perforator-Based Abdominal Flaps

  • Dogan, Zeynep Deniz Akdeniz;Sacak, Bulent;Yalcin, Dogus;Pilanci, Ozgur;Tuncer, Fatma Betul;Celebiler, Ozhan
    • Archives of Plastic Surgery
    • /
    • v.44 no.2
    • /
    • pp.109-116
    • /
    • 2017
  • Background The effect of liposuction on the perforators of the lower abdominal wall has been investigated in several studies. There are controversial results in the literature that have primarily demonstrated the number and patency of the perforators. The aim of this study was to determine the effect of liposuction on the perfusion of perforator-based abdominal flaps using a combined laser-Doppler spectrophotometer (O2C, Oxygen to See, LEA Medizintechnik). Methods Nine female patients undergoing classical abdominoplasty were included in the study. Perforators and the perfusion zones of the deep inferior epigastric artery flap were marked on the patient's abdominal wall. Flap perfusion was quantitatively assessed by measuring blood flow, velocity, capillary oxygen saturation, and relative amount of hemoglobin for each zone preoperatively, after tumescent solution infiltration, following elevation of the flap on a single perforator, and after deep and superficial liposuction, respectively. Results The measurements taken after elevation of the flap were not significantly different than measurements taken after the liposuction procedures. Conclusions The liposuction procedure does not significantly alter the perfusion of perforator-based abdominal flaps in the early period. The abdominal tissue discarded in a classic abdominoplasty operation can be raised as a perforator flap and has been demonstrated to be a unique model for clinical research.