• Title/Summary/Keyword: Superconducting tapes

Search Result 261, Processing Time 0.031 seconds

Development and properties of jointed Bi-2223 superconductor tape

  • Kim, Jung-Ho;Ji, Bong-Ki;Park, Hyung-Sang;Kim, Ho-Jin;Oh, Seung-Jin;Kim, Joong-Seok;Joo, Jin-Ho;Nah, Won-Soo
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.298-303
    • /
    • 2000
  • We evaluated the electric properties of Bi-2223 jointed tapes processed by both resistive- and supercondcuting-joint methods. For the resistive-joint, filler materials of wood metal, Pb/Sn, In, and silver paste were used, whereas, for the superconductive-joint, the lap joint method were used. In the resistive-joint tape, it was observed that the electrical properties such as current transport property, n-value, and contact resistance of the tape were significantly related to the resistivity of filler materials. On the other hand, in the superconducting-joint tape, the current transport property was dependent on the uniaxial pressure. Specifically, the current transport property varied 50 to 80% with uniaxial pressure, probably due to the irregular microstructure in the transition region.

  • PDF

Fabrication and Characteristic Tests of a 1 MVA Single Phase HTS Transformer with Concentrically Arranged Windings

  • Kim, S.H.;Kim, W.S.;Choi, K.D.;Joo, H.G.;Hong, G.W.;Han, J.H.;Lee, H.G.;Park, J.H.;Song, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.37-40
    • /
    • 2004
  • A 1 MV A single phase high temperature superconducting (HTS) transformer was manufactured and tested. The rated voltages of primary and secondary of the HTS transformer are 22.9 kV and 6.6 kV respectively. BSCCO-2223 HTS tape was used for HTS windings of 1 MV A HTS transformer. In order to reduce AC loss generated in the HTS winding, the type of concentric arrangement winding was adopted to a 1 MV A HTS transformer. Single HTS tape for primary windings and 4 parallel HTS tapes for secondary windings were used considering the each rated current of the HTS transformer. A core of HTS transformer was fabricated as a shell type core made of laminated silicon steel plate. And a GFRP cryostat with a room temperature bore was also manufactured. The characteristic tests of 1 MV A HTS transformer were performed such as no load test, short circuit test and several insulation tests at 65 K using sub-cooled liquid nitrogen. From the results of tests, the validity of design of HTS transformer was ascertained.

Effect of the Buffered-template on the Property of YBCO Superconducting Film Deposited by MOCVD Method (MOCVD 법에 의해 제조된 YBCO 초전도 박막의 물성에 대한 완충층 템플릿의 영향)

  • Jun, Byung-Hyuk;Choi, Jun-Kyu;Kim, Chan-Joong
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • [$YBa_2Cu_3O_{7-x}$] thin films were deposited on various buffered-templates by a metal organic chemical vapor deposition(MOCVD). Three different templates of $CeO_2/YSZ/CeO_2/pure-Ni(CYC),\;CeO_2/YSZ/Y_2O_3/Ni-3at.%W(YYC)$ and $CeO_2/IBAD-YSZ$/stainless steel were used. The Ni and Ni-W alloy tapes were biaxially textured by cold rolling and annealing heat treatment. The dense YBCO films were grown on both the IBAD and YYC templates with no microcrack, while the YBCO films on the CYC templates were grown with the formation of microcracks and NiO. The YBCO film on the YYC template showed the higher $I_c$ than that on CYC template. Especially, the IBAD templates with a thin $CeO_2$(type I) and thick $CeO_2$(type II) top layer were used to compare the deposition nature of the YBCO on them. Comparing the current property of the YBCO films on IBAD templates, the YBCO film deposited on thick $CeO_2$ layer was better than the film on thin $CeO_2$ layer.

  • PDF

Analysis of Self Magnetic Field Effects in a Bi-2223 Stacked Superconducting Bus Bar (Bi계 고온 초전도 선재 부스바에서의 자기 자장 해석)

  • Kang, Hyoung-Ku;Nah, Wan-Soo;Joo, Jin-Ho;Yoo, Jai-Moo;Oh, Sang-Soo;Ryu, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.302-304
    • /
    • 1998
  • Self magnetic field in a Bus bar usually degrades the critical current in it. Actually the total critical current of a Bus bar is not the same as the sum of total critical current of each stacked HTS tape. This is due to the self field effects in a bus bar. To reduce the degradations of critical current in a bus bar, we need to analyze the self field distributions in a bus bar. Conceptually, by rearranging the each stacked tapes, the self field effects can be minimized. In this paper, we calculate the self magnetic field distributions across a bus bar analytically, with the variations of the relative angle of the two conductors in a go-and-return pair. As a result, we suggest that the optimum relative angle exist which minimize the self field effect in a bus bar.

  • PDF

The a.c. losses in (Bi,Pb)2Sr2Ca2Cu3Ox silver-sheathed superconducting tapes (Bi-2223 고온 초전도 선재의 교류손실에 관한 연구)

  • Kang, Hyoung-Ku;Chu, Yong;Lee, Chan-Joo;Ko, Tae-Kuk;Nah, Wan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.822-824
    • /
    • 2000
  • To apply HTS to AC devices, it is necessary that study theoretically and experimentally to analyze the AC losses. It should be investigated the theoretical mechanisms precede the actual experiments. Because the AC losses cause some complicated troubles in AC machines, we can design the machines properly. In this study, firstly we analyze the basic cause of AC losses by investigating the several loss factors, secondly measure the AC losses of HTS by using Magnetization. Technique and this results show that AC losses of HTS is tenuous than those of general materials used in power system. Consequently we can compare the actual results with the theoretical results. And we find that AC losses of HTS are related to the amplitude of external magnetic field and the frequency. Through this study, we find that it is possible to apply the results by Magnetization. Technique to the AC power system, to the design of AC machine, to design of HTS proper to the foretold AC losses.

  • PDF

Study on fabricated RF coil using high-temperature superconductor tape and matching circuit for low field MRI system (고온초전도 선재와 정합회로를 이용한 RF coil 제작에 대한 기초연구)

  • Kim, D.H.;Ko, R.K.;Kang, B.M.;Ha, D.W.;Sohn, M.H.;Mun, C.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.44-47
    • /
    • 2012
  • The substantial improvement of the signal-to-noise ratio (SNR) can be achieved with small-size samples or low-field MRI system by high-temperature superconducting(HTS) RF coil. The typical HTS RF coil made of HTS thin film is expensive and is limited the coil geometry to planar surface coil. In this study, commercial Bi-2223 HTS tapes was used as RF coil for a 0.35T permanent MRI system. It has advantages of both much lower cost and easier fabrication over HTS thin film coil. SNR gain of the image obtained from the HTS RF coil over a conventional Cu RF coil at room temperature was about 2.4-fold and 1.9-fold using the spin echo pulse sequence and gradient echo pulse sequence respectively.

Investigation on the inductive and resistive fault current limiting HTS power cable

  • Lee, Sangyoon;Choi, Jongho;Kim, Dongmin;Kwon, Yonghyun;Kim, Seokho;Sim, Kideok;Cho, Jeonwook
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.59-63
    • /
    • 2014
  • HTS power cable bypass the fault current through the former to protect superconducting tapes. On the other hand, the fault current limiting (FCL) power cable can be considered to mitigate the fault current using its increased inductance and resistance. Using the increased resistance of the cable is similar to the conventional resistive fault current limiter. In case of HTS power cable, the magnetic field of HTS power cable is mostly shielded by the induced current on the shield layer during normal operation. However, quench occurs at the shield layer and its current is kept below its critical current at the fault condition. Consequently, the magnetic field starts to spread out and it generates additional inductive impedance of the cable. The inductive impedance can be enhanced more by installing materials of high magnetic susceptibility around the HTS power cable. It is a concept of SFCL power cable. In this paper, a sample SFCL power cable is suggested and experimental results are presented to investigate the effect of iron cover on the impedance generation. The tests results are analyzed to verify the generation of the inductive and resistive impedance. The analysis results suggest the possible applications of the SFCL power cable to reduce the fault current in a real grid.

Fabrication, AC Loss Measurement and Analysis of Bi-2223 Conductors with Respect to Various Twist Pitch (트위스트 피치를 고려한 Bi-2223 선재 제작과 AC 손실 측정 및 분석)

  • Jang, Mi-Hye;Chu, Yong;Lim, Jun-Hyung;Joo, Jin-Ho;Ko, Tae-Kuk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.11
    • /
    • pp.589-595
    • /
    • 2000
  • In this papre, AC losses of Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist and different twist pitch(8, 10, 13, 30, 50, 70 mn). The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-probe method. And the AC loss measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the critical current is larger non-twist than twisted filament. And, the AC loss by Norris equation is higher non-twisted tape than 13mm twisted tape. Also, it is confirmed that of AC loss of tape having non-twist pitch larger than those having differnet twist pitch.

  • PDF

Test of Insulation of Double Pancake Windings for a 1MVA HTS Transformer (1MVA 고온초전도 변압기용 더블 팬케이크 권선의 절연시험)

  • Kim, Sung-Hoon;Kim, Woo-Seok;Choi, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Hahn, Song-Yop;Song, Hee-Suck;Park, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1015-1017
    • /
    • 2003
  • In a research and development team of high temperature superconducting (HTS) transformer for power distribution, prior to manufacture a single phase 1MVA 22.9 kV/6.6 kV HTS transformer, a 1MVA transformer for insulation test with windings made of copper tapes with the same size as BSCCO-2223 HTS tape was manufactured. The test transformer was composed of both the copper windings of double pancake type and the shell type core of laminated silicon steel plates. The characteristics tests of the test transformer were performed, such as no load test, load test and short test at 77k using liquid nitrogen. Insulation tests, lightning impulse test, power-frequency voltage test and external insulation test, were accomplished also.

  • PDF

Study on the electrical characteristics of the jointed superconducting tapes for power application (접합된 초전도 선재의 응용을 위한 전기적 특성 연구)

  • Chang, Ki-Sung;Kim, Hyoun-Kyu;Kim, Min-Jae;Bang, Joo-Seok;Lee, Hai-Gun;Ko, Tae-Kook
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1311-1312
    • /
    • 2007
  • 본 논문에서는 YBCO coated conductor(CC) 의 접합연구와 접합된 선재의 응용을 위한 특성연구를 수행하였다. 최근에 지속적으로 연구 개발되어 본격적으로 응용이 시작되는 CC는 기본적으로 높은 인덱스 값과 자기장에 대한 임계전류의 균일성 등 다른 고온초전도에 비해 좋은 특성을 갖고 있으며 따라서 미래의 초전도 기기에 광범위하게 사용될 것으로 예상된다. CC와 같은 초전도 선재가 초전도 기기에 적용되는 경우 대부분 초전도 선재와 초전도 사이의 접합, 초전도 선재와 상전도체 사이의 접합 등의 접합들이 존재하게 된다. 접합을 위해서는 접합 땜납이 들어가게 되고 이 부분에서 저항이 발생하게 되어 손실이 발생하게 된다. 이러한 손실은 저항이 '0'이어서 손실이 적다는 초전도기기의 장점을 떨어뜨리는 요인이 될 수 있다. 따라서 CC의 접합 특성을 연구 하는 것은 초전도 기기의 성능향상에 도움을 줄 수도 있는 요인이 될 수 있다. 이 논문에서는 구리 안정화층, YBCO 층, 완충층과 기판층으로 이루어진 YBCO CC 선재를 이용하여 두 가지의 접합 방법을 이용하여 접합특성을 연구하였다.

  • PDF