• 제목/요약/키워드: Superconducting power supply

검색결과 106건 처리시간 0.029초

Investigation on helix type labyrinth seal to minimize leakage flow of cryogen for rotating superconducting machines

  • Yubin Kim;Kihwan Kim;Seungcheol Ryu;Hojun Cha;Seokho Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제26권1호
    • /
    • pp.25-30
    • /
    • 2024
  • High-temperature superconducting rotors offer advantages in terms of output-to-weight ratio and efficiency compared to conventional phase conduction motors or generators. The rotor can be cooled by conduction cooling, which attaches a cryocooler, and by refrigerant circulation, which uses circulating liquid or gas neon, helium and hydrogen. Recent work has focused on environmental issues and on high-temperature superconducting motors cooled with liquid hydrogen that can be combined with fuel cells. However, to ensure smooth supply and return of the cryogenic cooling fluid, a cryogenic rotational coupling between the rotating and stationary parts is necessary. Additionally, the development of a sealing structure to minimize fluid leakage applicable to the coupling is essential. This study describes the design and performance evaluation of a non-contact sealing method, specifically a labyrinth seal, which avoids power loss and heat load caused by friction in contact sealing structures. The seal design incorporates a spiral flow path to reduce leakage using centrifugal force, and computational fluid dynamics (CFD) simulations were conducted to analyze the flow path and rotational speed. A performance evaluation device was configured and employed to evaluate the designed seal. The results of this study will be used to develop a cryogenic rotational coupling with supply and return flow paths for cryogenic applications.

120kV/70A MOSFETs Switch의 구동회로 개발 (Development of the 120kV/70A High Voltage Switching Circuit with MOSFETs Operated by Simple Gate Drive Unit)

  • 송인호;신현석;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.707-710
    • /
    • 2002
  • A 120kV/70A high voltage switch has been installed at Korea Atomic Energy Research Institute in Taejon to supply power with Korea Superconducting Tokamak Advanced Research (KSTAR) Neutral Beam Injection (NBI) system. NBI system requires fast cutoff of the power supply voltage for protection of the grid when arc detected and fast turn-on the voltage for sustaining the beam current. Therefore the high voltage switch and arc current detection circuit are important part of the NBI power supply and there are much need for high voltage solid state switches in NBI system and a broad area of applications. This switch consisted of 100 series connected MOSFETs and adopted the proposed simple and reliable gate drive circuit without bias supply, Various results taken during the commissioning phase with a 100kW resistive load and NBI source are shown. This paper presents the detailed design of 120kV/70A high voltage MOSFETs switch and simple gate drive circuit. Problems with the high voltage switch and gate driver and solutions are also presented.

  • PDF

초전도 Power Supply의 전류펌핑 과정에서 발생하는 조기 퀜치발생 진단 (A study on the Detection of Premature Quench Generated in the Process of Current Pumping in a Superconducting Power Supply)

  • 김호민;배준한;노정섭;심기덕;장원갑;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.244-246
    • /
    • 1997
  • This paper is to analyze the Premature Quench characteristics of a rotating magnet type superconducting fluxpump and consider the method of detecting and protecting this premature quench. Practically, there is contact resistance between the fluxpump and the load, namely the S.C. magnet. The thermal increase due to the contact resistance cause the premature quench before the charging current amounts to the critical current of S.C magnet. Therefore, this paper is devoted to solving the heat equation on contact region using cylindrical coordinates and to calculating the rate of thermal increase during the current is pumped up. Doing so, the predictive value of the maximum pumping current is obtained. It has been verified that the results of simulation are coincident with those of experiment. It must be considered essentially to minimize the contact resistance in designing the S.C fluxpump system in order to protect the premature quench and improve the maximum pumping current.

  • PDF

Diode를 이용한 박막형 한류기의 열발생 저감방안 (Generated heat decrease of thin film superconducting fault current limiter using diodes)

  • 최효상;현옥배;김혜림;황시돌
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권2호
    • /
    • pp.11-14
    • /
    • 2000
  • We fabricated a resistive superconducting fault current limiter (SFCL) of meander type based on a YBCO film. In order to disperse the heat generated at hot spots in the YBCO film the film was coated with a gold shunt layer. When diodes were inserted in the parallel circuit to restrict the temperature increase in the SFCL element by reducing power supply cycles, the voltage could be increased to $\sqrt{2}$ times with the same quench resistance at a half and full cycles.

  • PDF

CICC 형태의 초전도 버스 선에서 냉각 및 자기장에 의한 응력 해석 (Analysis of the stresses induced by magnetic field and cooling in the CICC type superconducting bus-line)

  • 이호진;남현일;김기백;홍계원
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권2호
    • /
    • pp.20-25
    • /
    • 2000
  • A CICC type superconducting bus-line electrically connecting a superconducting magnet to a power supply is cooled down to low temperature under the external magnetic field during operation. The thermal contraction during the cooling may be constrained by the supports which are installed to protect the bus-line from Lorenz magnetic forces. This constrained contraction causes thermal stresses in the bus-line to release thermal contraction. The minimum stress conditions in the bus-line may be optimized by controlling the supporting arrangement considering the thermal contraction and the external field. The analytical method to find optimal supports arrangement was suggested by using the beam theory, and numerical calculation using commercial code was performed to verify the suggested analytical optimization method.

  • PDF

리니어타잎 초전도 전원장치의 동작특성 (Operating characteristics of linear type magnetic flux pump)

  • 정윤도;배덕권;윤용수;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.665-666
    • /
    • 2008
  • Inserted HTS (high temperature superconducting) coil is promisingly expected as a solution for achievement of higher fields such as GHz scale NMR magnet. However, HTS magnet causes persistent current decay in the persistent current mode and this decay should be compensated in order to keep stable magnetic field. As a solution for the decay in the HTS magnets, we proposed a new type superconducting power supply, i.e., linear type magnetic flux pump (LTMFP). The LTMFP mainly consists of DC bias coil, 3-phase AC coil and superconducting Nb foil. The compensating current in closed superconductive circuit can be easily controlled by the intensity of 3-phase AC current and its frequency. In this study, it has been investigated that the flux pump can effectively charge the current for various frequencies according to the different load magnets.

  • PDF

영구전류모드를 가지는 초전도 마그네트 시스템의 여자방법 (Energization method of Superconducting Magnet System with Persistent Current Mode)

  • 예정희;나완수;주진호;홍계원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.305-307
    • /
    • 1998
  • One of the merits of superconducting magnet system is that it has persistent current mode, in which the current can be constant without any external power supply. The problem is that when we energize the magnet we can not reach the target current with constant current source, in principle. It needs another energization methods, in which it can be energized with reasonable accuracy and time. This paper suggests two energization methods for a superconducting magnet with persistnet current mode and the comparisons of the two are made with respect to the accuracy and the time.

  • PDF

초전도한류기와 인근 배전설비의 신뢰도에 관한 연구 (A Study on the Reliability of Superconducting Fault Current Limiter and Adjacent Distribution Equipments)

  • 배인수;김성열;김진오
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2122-2127
    • /
    • 2009
  • This study presents the failure rate and repair rate of Superconducting Fault Current Limiter(SFCL) and adjacent distribution equipments. When the fault current penetrated SFCL, the supply of electric power to the customers can be partly continued. It is expected that SFCL makes to improve the reliability index of customers. Contrary to the expectations, the series connection between SFCL and distribution system could deteriorate the reliability index. To evaluate the reliability index in the distribution system including SFCL, the failure rate and repair rate of SFCL are required as well as that of distribution equipments. Also, the insertion of SFCL makes to change the failure rate and repair rate of adjacent equipments. This study proposes a method to calculate the failure rate and repair rate of a component combining SFCL and adjacent equipments.

고온초전도케이블의 계통적용을 위한 개념설계 (Review of the Conceptual Design for the use of the HTS Cable to Power System)

  • 최상봉;김대경;정성환;문영환;성기철;김학만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.253-255
    • /
    • 2002
  • The necessity of compact high temperature super conducting cables is more keenly felt in densely populated metropolitan areas. As the compact high temperature superconducting cables that can be installed in ducts and tunnels can reduce construction cost and make the use of underground space more effective, the effect of introducing it to power system will be huge. For this study, Seoul, Korea is selected as a review model, the loads are estimated by scenario based on a survey and analysis of 345kV and 154kV power supply networks in this area. Based on this, the following items on urban transmission system are examined. (1) A method of constructing a model system to introduce high temperature superconducting cables to metropolitan areas is presented. (2) A case study through the analysis of power demand is conducted, and the amount of high temperature superconducting cable to be introduced by scenario is examined. (3) The economy involved in expanding existing cables and introducing high temperature superconducting cables(ducts or tunnels) following load increase in urban areas is examined and compared. (4) The maximum external diameter of HTS cable to accommodate exiting ducts based on the design standards for current cable ducts is calculated. (5) The voltage level that can be accommodated by existing ducts is examined.

  • PDF

KSTAR 100kV NBI 전원공급장치 운전 결과 (Operation results of the KSTAR NBI 100kV power supply system)

  • 최대준;차한주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.425-426
    • /
    • 2017
  • 본 논문은 미래 녹색에너지원으로 주목받는 핵융합에너지 개발 장치인 한국형 초전도 핵융합 연구로(KSTAR : Korea Superconducting Tokamak Advanced Research)의 가열장치인 중성입자빔(NBI : Neutral Beam Injector) 장치를 소개하고, 2016년 KSTAR 실험에서 빔 에너지 90/70/80 keV, 빔 출력 3.81 MW, 70.6초의 최대 장 펄스와 빔 에너지 95/90/90 keV, 빔 출력 5.13 MW, 10.6 초로 입사 운전한 NBI 장치 실험 결과를 정리한다.