• 제목/요약/키워드: Superconducting critical temperature

검색결과 382건 처리시간 0.028초

Investigation on Effective Operational Temperature of HTS Cable System considering Critical Current and AC loss

  • Kim, Tae-Min;Yim, Seong-Woo;Sohn, Song-Ho;Lim, Ji-Hyun;Han, Sang-Chul;Ryu, Kyung-Woo;Yang, Hyung-Suk
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.307-310
    • /
    • 2016
  • The operational cost for maintaining the superconductivity of high-temperature superconducting (HTS) cables needs to be reduced for feasible operation. It depends on factors such as AC loss and heat transfer from the outside. Effective operation requires design optimization and suitable operational conditions. Generally, it is known that critical currents increase and AC losses decrease as the operational temperature of liquid nitrogen ($LN_2$) is lowered. However, the cryo-cooler consumes more power to lower the temperature. To determine the effective operational temperature of the HTS cable while considering the critical current and AC loss, critical currents of the HTS cable conductor were measured under various temperature conditions using sub-cooled $LN_2$ by Stirling cryo-cooler. Next, AC losses were measured under the same conditions and their variations were analyzed. We used the results to select suitable operating conditions while considering the cryo-cooler's power consumption. We then recommended the effective operating temperature for the HTS cable system installed in an actual power grid in KEPCO's 154/22.9 kV transformer substation.

Superconducting properties of SiC-buffered-MgB2 tapes

  • Putri, W.B.K.;Kang, B.;Duong, P.V.;Kang, W.N.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.1-4
    • /
    • 2015
  • Production of $MgB_2$ film on metallic Hastelloy with SiC as the buffer layer was achieved by means of hybrid physical-chemical vapor deposition technique, whereas SiC buffer layers with varied thickness of 170 and 250 nm were fabricated inside a pulsed laser deposition chamber. Superconducting transition temperature and critical current density were verified by transport and magnetic measurement, respectively. With SiC buffer layer, the reduced delaminated area at the interface of $MgB_2$-Hastelloy and the slightly increased $T_c$ of $MgB_2$ tapes were clearly noticed. It was found that the upper critical field, the irreversibility field and the critical current density were reduced when $MgB_2$ tapes were buffered with SiC buffer layer. Clarifying the mechanism of SiC buffer layer in $MgB_2$ tape in affecting the superconducting properties is considerably important for practical applications.

초전도 마그네트용 실용 초전도 복합선재의 기계적 특성 및 피로손상 평가에 관한 연구 (Evaluation of Mechanical Property and Fatigue Damage in A Practical Superconducting Cable for Magnet)

  • 신형섭;오상수
    • 대한기계학회논문집A
    • /
    • 제24권3호
    • /
    • pp.761-768
    • /
    • 2000
  • In order to investigate how the fatigue damage effects on the critical properties of superconductor, a fatigue test at room temperature and an Ic measurement test at 4.2K were carried out in this study, respectively, using a 9 strand Cu-Ni/NbTi/Cu composite cable. Through the fatigue test of a 9 strand Cu-NUNbTi/Cu composite cable, a conventional S-N curve was plotted even though there was a possibility of fretting among strands. It was found that the maximum stress corresponding to the inflection point on the S-N curve obtained was nearly the same value as the yielding strength of cable obtained from the static tensile test. However, the effect of cabling in multi-strands superconducting cable on the fatigue strength was not noticeable. The critical current(Ic) measurement was carried out at 4.2K in a NbTi strand out of the fatigued cable. It showed a degradation of lc at high stress amplitude regions over 380NTa, and the degradation became significant as the applied stress amplitude increased.

22.9 kV 초전도케이블 시스템의 Thermal Cycle Test 영향 (Influence of Thermal Cycle Test of a 22.9 kV High Temperature Superconducting Cable System)

  • 손송호;임지현;양형석;류희석;최하옥;성태현;김동락;황시돌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.242-242
    • /
    • 2007
  • To verify the applicability of High Temperature Superconducting (HTS) cable system into the real grid, the HTS cable system with the specification of 22.9 kV, 1250 A, 100 m long was installed in the second quarter of 2006, and the long term field test has been in progress at the KEPCO's Gochang power testing yard. Apart from the conventional power cable, HTS cable system requires sufficient thermo-mechanical strength to endure a large temperature difference. To date, the KEPCO HTS cable system was cooled down and warmed to the room temperature several times to investigate the influence of thermal cycles experimentally. Dielectric properties, critical current dependance and heat losses were evaluated at each step of thermal cycle. The test results showed that thermal cycle did not induce the degradation of dielectric properties, and the critical current decreased to 5 % of the initial value.

  • PDF

Mg과 B 혼합분말을 이용하여 분말압연 공정으로 제조된 $MgB_2$ 초전도 판재연구 ($MgB_2$ Sheets using Mixture of Mg and B Powders by Powder Roll Compaction)

  • 정국채;장세훈;;김정호
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.184-188
    • /
    • 2012
  • $MgB_2$ superconducting sheets have been fabricated by powder rolling method using mixture of Mg and B powders. Sheet-type $MgB_2$ bulk samples of ~10 mm width and 50-100 mm long were squeezed out after compacted by two rotating rolls of 130 mm diameter with gap distance of 0.5 mm and speed of ~40 cm/min (~1 rpm). The nominal composition of Mg, which is ductile metal, was added up to 30% to facilitate forming the $MgB_2$ sheets. The annealed samples at $900^{\circ}C$ and 3 hrs showed superconducting transition temperature of ~32 K and critical current densities at zero fields were ${\sim}10^5A/cm^2$ at 5 K and ${\sim}5{\times}10^4A/cm^2$ at 20 K.

$Nb_3Sn$ 테이프 임계전류의 자장.온도 의존성 (Critical Current Density Dependence on Magnetic Field.Temperature of $Nb_3Sn$ Tape)

  • 장현만;오상수;하동우;조전욱;류강식;김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1399-1401
    • /
    • 1997
  • The stability of superconducting wires was studied by considering temperature and magnetic field. We measured critical current density of $Nb_3Sn$ tape at 4.2 K, 12 K, 13 K and 14 K in various field. The critical current density at 4.2 K, 6 T is 16.5 times higher than at 12 K, 6 T. We expressed the critical current density as a function of temperature and magnetic field, expanding on work by Hampshire, et al.

  • PDF

61심 BSCCO 2223 고온초전도 선재의 접합부 제조 (Fabrication of Superconducting Joints between 61 Filaments of BSCCO 2223 Tapes)

  • 김철진;박성창;유재무
    • 한국세라믹학회지
    • /
    • 제35권2호
    • /
    • pp.137-144
    • /
    • 1998
  • 고온초전도체 61심 Bi-2223 선재간의 초전도 접합부위를 화학적 부식 및 열적· 기계적 반복 공정에 의하여 제조하였다. 초전도 선재 테이프의 은 피복재 한쪽 표면을 초전도체와 반응하지 않는 부식액(NH4OH:H2O2=1:1)으로 화학적으로 제거한 다음, 두 시편을 일출가압 성형하여 접합시편을 제조하였고 일련의 서로 다른 열적· 기계적 처리를 거쳐 접합부의 물성 및 미세구조를 분석하였다. 접합부를 따라 임계전류(Ic) 변화와 전류전압 곡선의 특성을 측정하기 위하여 여러 단자를 접합부 주위에 설치하여 부위별 I~V 특성을 측정한 결과 단심선재에 비하여 다심선재에서 선재 전체의 통전 능력을 좌우하는 천이구간의 임계전류값이 높았다. 그러나 단심에 비해 다심선재는 천이급속도를 나타내는 n값이 다심선재내 각각의 초전도 core들의 상호작용에 의하여 낮은 값을 나타내었다. 접합부의 임계전류 통전성은 반복적인 가압성형 공정과 서냉반응 열처리 공정에 의하여 향상되었다.

  • PDF

Rf - magnetron sputtering system을 사용한 $YBa_2Cu_3O_x$ 초전도 박막의 제조 (The preparation of $YBa_2Cu_3O_x$ superconducting thin film using rf - magnetron sputtering system)

  • 박성진;김민기;최성환;최효상;황종선;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.717-720
    • /
    • 1992
  • Since the discovery of High-Tc superconducting Y-Ba-Cu-O ceramics with critical temperature of about 90K, numerous efforts to prepare supercond ucting thin films with excellent qualities such as High-Tc and critical current density have been made. The samples were deposited onto $SiO_x$ substrates heated at 540$^{\circ}C$ - 600$^{\circ}C$ in a single target rf - magnetron sputtering system. The film thickness has 2000$\AA$ - 5000 $\AA$ with a rate of 16 $\AA$/min. and distance between target and substrate was 50 mm. The films were characterized by X - ray diffraction, scanning electron microscopy and critical temperature.

  • PDF

$Nb_3Sn$ 복합초전도 테이프의 미시적 변형거동 특성평가를 위한 음향방출기법 적용에 관한 연구 (A Study on Microscopic Deformation Behaviors of $Nb_3Sn$ Superconducting Composite Tape using Acoustic Emission Technique)

  • 이민래;이준현
    • Composites Research
    • /
    • 제12권6호
    • /
    • pp.22-30
    • /
    • 1999
  • $Nb_3Sn$ 복합초전도 테이프는 금속간 화합물로서 다른 초전도 재료에 비하여 임계밀도가 높아 MRI등에 널리 이용되고 있다. 한편 $Nb_3Sn$층은 화합물이므로 bending이나 winding등의 코아 제작시 테이프 도체에 응력이 작용하면 화합물층에 취성으로 인한 크랙이 발생하여 부분적으로 파단이 일어나 임계전류 특성이 열화하며 무응력 상태에 비하여 크게 저하된다. 따라서 이와 같은 $Nb_3Sn$복합초전도 테이프의 실질적인 적용을 위해서는 선재의 제조과정 뿐만 아니라 가동 중에 기계적 응력에 대한$Nb_3Sn$복합 초전도 테이프의 미시적 거동 특성을 필히 이해하여야 할 필요가 있다. 본 연구에서는 음향방출기법(Acoustic Emission)을 이용하여 $Nb_3Sn$ 복합초전도 테이프에 대해서 일정변형속도(constant extension rate)제어로 인장하중이 작용할 경우 발생하는 AE 신호특성과 이에 대응하는 각 화합물층의 미시적 변형거동 특성과의 상관관계를 분석하였다.

  • PDF

냉동기 부착형 전도냉각식 Cryostat의 설계 및 제작 (Design and Fabrication of a Conductively Cooled Cryostat by Cryocooler)

  • 배준환;심기덕
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1921-1924
    • /
    • 2007
  • In order to measure the superconducting transition temperature, the critical current and the alternating current(AC) loss on short samples of high temperature superconductor, a cryocooler cooled cryostat has been designed and built. Two closed-cycle coolers provide cooling with an ultimate sample temperature below 16K. Temperature regulation is provided by 50W of electrical heater that opposes the cooling power from the cold heads. Temperature control feedback is by means of a cernox temperature sensor co-located with the heaters on the second stage of the cold head. Additional temperature sensors are located on the sample mount(B1), on the CVI cold head(B2) and on the Dakin cold head(B3). AC losses on the sample high temperature superconductor were measured at 30K so that the developed device performance was evaluated. In this paper, the design, fabrication and test results on the cryocooler cooled cryostat are presented.