• Title/Summary/Keyword: Super-P

Search Result 461, Processing Time 0.031 seconds

Characteristics of Flexural Behavior of Composite Section Consisting of Steel Girder with 80MPa High Strength Concrete on Compressive Flange (압축 플랜지에 80MPa급 고강도 콘크리트가 합성된 I형 강거더의 휨거동 특성)

  • Lee, Juwon;Yang, In-Wook;Lim, Eol;Ha, Tae-Yul;Lee, Kwan-Jong
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.455-464
    • /
    • 2017
  • Static loading test was performed on a composite girder with an I-shaped steel girder and SUPER concrete on the top of the steel in order to evaluate flexural behavior characteristics. Total length of the test specimen was 25m long and the depth was 786mm including compressive concrete section('casing' hereafter) with 80MPa strength. 4-point loading on simply-supported beam was applied up to 2,010kN. Results showed that yield strength at tensile steel was 2.7 times greater than service load and the ratio of ductility was 1.481. No cracks were found on the casing surface and the relative slip between different sections was insignificant.

Effect of and R Phase on the Pitting Corrosion in Super Duplex Stainless Steel (슈퍼 2상 스테인리스강의 공식에 미치는 R상의 영향)

  • Lee, Byung-Chan;Oh, Eun-Ji;Kang, Chang-Yong
    • Korean Journal of Materials Research
    • /
    • v.24 no.11
    • /
    • pp.610-616
    • /
    • 2014
  • In this study, we investigated the precipitation behavior of the R-phase precipitated at the initial stage of aging and its effect on the pitting corrosion of 25%Cr-7%Ni-4%Mo super duplex stainless steel. The R-phase in super duplex stainless steel was mainly precipitated at the interface of ferrite/austenite phases and inside of the ferrite phase during the initial stage of aging, and it was transformed into the ${\sigma}$-phase with an increase in aging time. The ferrite phase was decomposed into a new austenite phase and ${\sigma}$-phase. The R phase was an intermetallic compound, which represented a lower Ni and higher Mo than the matrix, and also had a higher Mo and Cr concentration than the ${\sigma}$ phase. With an increasing aging time, the pitting potential $E_p$ was increased slowly by the precipitation of the R-phase, and it was then steeply decreased by the precipitation of the ${\sigma}$-phase. The R-phase was decreased the pitting potential, but its effect was smaller than effect of ${\sigma}$-phase.

POSITIVE SOLUTION FOR A CLASS OF NONLOCAL ELLIPTIC SYSTEM WITH MULTIPLE PARAMETERS AND SINGULAR WEIGHTS

  • AFROUZI, G.A.;ZAHMATKESH, H.
    • Journal of applied mathematics & informatics
    • /
    • v.35 no.1_2
    • /
    • pp.121-130
    • /
    • 2017
  • This study is concerned with the existence of positive solution for the following nonlinear elliptic system $$\{-M_1(\int_{\Omega}{\mid}x{\mid}^{-ap}{\mid}{\nabla}u{\mid}^pdx)div({\mid}x{\mid}^{-ap}{\mid}{\nabla}u{\mid}^{p-2}{\nabla}u)\\{\hfill{120}}={\mid}x{\mid}^{-(a+1)p+c_1}\({\alpha}_1A_1(x)f(v)+{\beta}_1B_1(x)h(u)\),\;x{\in}{\Omega},\\-M_2(\int_{\Omega}{\mid}x{\mid}^{-bq}{\mid}{\nabla}v{\mid}^qdx)div({\mid}x{\mid}^{-bq}{\mid}{\nabla}v{\mid}^{q-2}{\nabla}v)\\{\hfill{120}}={\mid}x{\mid}^{-(b+1)q+c_2}\({\alpha}_2A_2(x)g(u)+{\beta}_2B_2(x)k(v)\),\;x{\in}{\Omega},\\{u=v=0,\;x{\in}{\partial}{\Omega},$$ where ${\Omega}$ is a bounded smooth domain of ${\mathbb{R}}^N$ with $0{\in}{\Omega}$, 1 < p, q < N, $0{\leq}a$ < $\frac{N-p}{p}$, $0{\leq}b$ < $\frac{N-q}{q}$ and ${\alpha}_i,{\beta}_i,c_i$ are positive parameters. Here $M_i,A_i,B_i,f,g,h,k$ are continuous functions and we discuss the existence of positive solution when they satisfy certain additional conditions. Our approach is based on the sub and super solutions method.

THE EFFECT OF THERMOCYCLING ON BOND STRENGTH BETWEEN METAL AND RESIN CEMENT (Thermocycling이 금속과 레진시멘트간의 결합강도에 미치는 영향)

  • Kang, Geon-Gu;Chung, Kwan-Ho;Choi, Jeong-Ho;Ahn, Seung-Geun;Song, Kwang-Yeob;Park, Chan-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.233-245
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of thermocycling on bond strength between metal and resin cement according to thermocycling, and to observe the bond failure modes with optical microscope(X30). For this purpose, Super-Bond C & B and Panavia 21 resin cement were used. Metal specimens were made of Vera-Bond and the surface of specimens were sandblasted with $50{\mu}m$ aluminum oxide. All experimental groups were stored in $37^{\circ}C$ distilled water for 72 hours, followed by thermocycling between $5^{\circ}C$ and $55^{\circ}C$ with 15 second dwell time. 500, 1000, 2000 cycles of thermocycling were executed and the tensile bond strength was measured by Instron Universal Testing Machine(Model 4201) The obtained results were as follows : 1. Super-Bond C & B and Panavia 21 did not show statistically significant difference accor-ding to thermocycling test(P>0.05). 2. Super-Bond C & B specimens exhibited statistically significant higher tensile bond stre-ngth than Panavia 21 for all experimental groups(P<0.05). 3. Super-Bond C & B exhibited mixed mode failure with partial adhesive and partial cohe-sive failure, and most of Panavia 21 exhibited cohesive failure and some mixed mode failure.

  • PDF

An electrochemical study of the sealing ability of three retrofilling materials

  • Park, Dong-Sung;Sohn, Suh-Jin;Oh, Tae-Seok;Yoo, Hyun-Mi;Park, Chan-Je;Yim, Soon-Ho;Lee, Young-Kyoo;Kye, Seung-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.365-369
    • /
    • 2004
  • The purpose of this study was to evaluate the apical sealing ability of Super-EBA, MTA and Dyract-flow as retrofilling materials. Forty-eight extracted human teeth with straight and single root canal were used in this study. The root canals were prepared to a #40 apical canal size and obturated with gutter-percha. Apicoectomies were performed and root end cavities were prepared to a depth of 3mm using an ultrasonic device. The root end cavities were filled with Super-EBA, MTA or Dyract-flow. Leakage was measured using an electrochemical technique for 4 weeks. According to this study, the results were as follows. 1. Increasing leakage with time was observed in all groups. 2. No significant difference was noted among the 3 groups with time (p =0.216). 3. No significant difference was noted among the 3 groups when measured within the same time interval (p =0.814). The results of this study suggest that the sealing ability of Dyract-flow is equal to that of Super-EBA and MTA, and Dyract-flow may be an alternative to other materials for root-end filling.

COMPARISON OF THE SEALING ABILITY OF VARIOUS RETROGRADE FILLING MAIERIALS (수종의 역충전 재료의 치근단 밀폐력 비교)

  • 황윤찬;강인철;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.379-386
    • /
    • 2001
  • This study was performed to evaluate the sealing ability of various retrograde filling materials by using bacterial penetration and dye penetration test. One hundred and forty extracted human teeth with single, straight canals and mature apiece were collected and used for this study. All canals were instrumented using an engine driven Ni-Ti file (ProFile). After removing 3mm from the apex of tooth, a standardized 3mm root end cavity was prepared using an ultrasonic instrument. The 70 teeth were randomly divided into 7 groups : 6 groups for retrograde filling using Super-EBA, ZOE, Chelon-Silver, IRM, ZPC and amalgam. The 7th group was used as a negative control. Nail varnish was applied to all external root surfaces to the level of the reseated root ends to prevent lateral microleakages. The specimens were then sterilized in an ethylene oxide sterilizer for 24 hours. 2 mm of the reseated root was immersed in a culture chamber containing a Tripticase Soy Broth with a phenol red indicator. The coronal access of each specimen was inoculated every 72 hours with suspension of Proteus vulgaris. The culture media were observed every 24hours for color change indicating bacterial contamination. The specimens were observed for 4weeks. The remaining 70 teeth were submitted to a dye penetration test. The canals of all teeth were first sealed with AH26 and obturated using an Obtura II system. Root resection, root end preparation and retrograde filling was performed as above. All specimens were suspended in 2% methylene blue dye for 72 hours before being ion gitudinally split. The degree of dye penetration was then measured using a stereomicroscope at 10 magnification and evaluated. The results were as floows : 1. In the bacterial penetration, the degree of leakage was the lowest in the Super-EBA, followed by, in ascending order, ZOE, Chelon-Silver IRM and ZPC. The amalgam showed highest bacterial leakage of all(p<0.01). 2. In the dye penetration, the degree of microleakage was the lowest in the Chelon-Silver and Super-EBA, followed by, in ascending order, IRM, ZPC. The ZOE and amalgam showed the highest microleakage of all (p<0.05). These results suggested that the eugenol based cement, Super-EBA, have excellent sealing ability as a retrograde filling material.

  • PDF

SPECTROPHOTOMETRIC EVALUATION OF SEALING EFFECTS OF SEVERAL ROOT-END FILLING MATERIALS (분광광도법을 사용한 수종 역충전재의 근단부 폐쇄효과에 관한 연구)

  • Yi, Jin-Gyu;Park, Sang-Jin;Choi, Kyung-Kyu;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.449-456
    • /
    • 2003
  • The purpose of this study is to evaluate the sealing effect of several root-end filling materials using spectrophotometric analysis. 180 single root teeth with one canal were instrumented and canal filled. Root resected and root end preparation was made. Teeth were randomly classified to S experimental group(MTA, EBA, IRM, TCP, ZOE) and 1 control group according to root-end filling material MTA group used PRO ROOT MT A, EBA group used Super EBA. TCP group used NEW APATITE LINER TYPE II main component of which is ${\alpha}-tricalcium$ phosphate (TCP). According to manufacture's instruction experimental material was mixed and retrfilled. After 2% methylene blue solution penetration absorbance for each test sample was measured with spectrophotometer (JASCO UV-530, Japan). The mean absorbance of control and experimental group was as follows; MTA: 0.092, IRM: 0.226, Super EBA: 0.255, ZOE: 0.374, Control: 0.425, TCP: 0.501 and the result analyzed by Turkey test at P=0.05 level. Conclusions of this study are as follows; 1. The absorbance increase in following sequence MTA, IRM, Super EBA, ZOE, Control. TCP. 2. MTA showed the least leakage but was not significant with IRM or Super EBA and was significant with control or TCP(p<0.05). 3. TCP had the most leakage and was not significant with control group.

Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study

  • Wong, Uni;Person, Erik B;Castell, Donald O;von Rosenvinge, Erik;Raufman, Jean-Pierre;Xie, Guofeng
    • Journal of Neurogastroenterology and Motility
    • /
    • v.24 no.4
    • /
    • pp.570-576
    • /
    • 2018
  • Background/Aims Swallows with viscous or solid boluses in different body positions alter esophageal manometry patterns. Limitations of previous studies include lack of standardized viscous substrates and the need for chewing prior to swallowing solid boluses. We hypothesize that high-resolution impedance manometry (HRiM) using standardized viscous and super-viscous swallows in supine and upright positions improves sensitivity for detecting esophageal motility abnormalities when compared with traditional saline swallows. To establish normative values for these novel substrates, we recruited healthy volunteers and performed HRiM. Methods Standardized viscous and super-viscous substrates were prepared using "Thick-It" food thickener and a rotational viscometer. All swallows were administered in 5-mL increments in both supine and upright positions. HRiM metrics and impedance (bolus transit) were calculated. We used a paired two-tailed t test to compare all metrics by position and substrate. Results The 5-g, 7-g, and 10-g substrates measured 5000, 36 200, and 64 $700mPa{\cdot}sec$, respectively. In 18 volunteers, we observed that the integrated relaxation pressure was lower when upright than when supine for all substrates (P < 0.01). The 10-g substrate significantly increased integrated relaxation pressure when compared to saline in the supine position (P < 0.01). Substrates and positions also affected distal contractile integral, distal latency, and impedance values. Conclusions We examined HRiM values using novel standardized viscous and super-viscous substrates in healthy subjects for both supine and upright positions. We found that viscosity and position affected HRiM Chicago metrics and have potential to increase the sensitivity of esophageal manometry.

A Locality based Resource Management Scheme for Hierarchical P2P Overlay Network in Ubiquitous Computing (계층적 P2P에서의 근거리 기반 효율적 자원관리 기법)

  • Hong, Chung-Pyo;Kim, Cheong-Ghil;Kim, Shin-Dug
    • Journal of Digital Contents Society
    • /
    • v.14 no.1
    • /
    • pp.89-95
    • /
    • 2013
  • Many peer-to-peer (p2p) systems have been studied in distributed, ubiquitous computing environments. Distributed hash table (DHT)-based p2p systems can improve load-balancing even though locality utilization and user mobility are not guaranteed. We propose a mobile locality-based hierarchical p2p overlay network (MLH-Net) to address locality problems without any other services. MLH-Net utilizes mobility features in a mobile environment. MLH-Net is constructed as two layers, an upper layer formed with super-nodes and a lower layer formed with normal-nodes. The simulation results demonstrate that MLH-Net can decrease discovery routing hops by 13% compared with JXTA and 69% compared with Chord. It can decrease the discovery routing distance by 17% compared with JXTA and 83% compared with Chord depending on the environment.

A COMPARATIVE STUDY OF THE RESISTANCE TO DISLODGEMENT OF FIXED PROSTHESES USING $BIO-PIN^{(R)}$ ($Bio-pin^{(R)}$을 이용한 고정성 보철물의 탈락저항강도의 비교연구)

  • Yi Jong-Won;Cho In-Ho;Lee Jong-Hyuk;Kim Seung-Ki
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.176-190
    • /
    • 2005
  • Statement of problem. The current trend in prosthodontics is the adoption of a conservative approach to preparing dental prostheses by minimizing the amount of sound tooth structure removal during preparation. Purpose. The major disadvantage of the adhesion bridge is the inherently poor resistance to dislodgement that its use in areas subjected to high occlusal load is limited. The purpose of this study was to compare the dislodgement resistance of $Bio-pin^{(R)}$, conventional 3-unit and adhesion bridges. Material and methods. The experimental groups were classified as follows : Group I : 3-unit bridge cemented using $Super-Bond^{(R)}$ C&B Group II : Adhesion bridge cemented using $Super-Bond^{(R)}$ C&B Group III : $Bio-pin^{(R)}$ design adhesion bridge without incorporation of $Bio-pin^{(R)}$ (cemented using $Super-Bond^{(R)}$ C&B) Group IV-1 : $Bio-pin^{(R)}$ retained adhesion bridge incorporating a single $Bio-pin^{(R)}$ (cemented using $Super-Bond^{(R)}$ C&B) Group IV-2 : $Bio-pin^{(R)}$ retained adhesion bridge incorporating a single $Bio-pin^{(R)}$ (cemented using $Panavia^{(R)}$ F) Group V : $Bio-pin^{(R)}$ retained adhesion bridge incorporating two $Bio-pins^{(R)}$ (cemented using $Super-Bond^{(R)}$ C&B) Results. The results of this study were as follows : 1. Significant differences in dislodgement resistance of the restorations were found between Group I, Group II and Group III (p<0.05). No significant differences in dislodgement resistance of the restorations were observed between Group I Group IV-1 and Group V. However, there were significant differences in dislodgement resistance between Group II and the other groups (p<0.05). 2. No significant differences in dislodgement resistance of the restorations were observed between GroupIV-1 and GroupIV-2, both of which utilized a single $Bio-pin^{(R)}$. However, significant differences were observed when Group III was compared to either GroupIV-1 or Group V (p<0.05). 3. No significant differences in dislodgement resistance relative to the type of dental cements used were found. Conclusion. From the above results, it is concluded that the dislodgement resistance of $Bio-pin^{(R)}$ bridge restorations utilizing a single $Bio-pin^{(R)}$ is similar to that of a conventional 3-unit bridge. The results also suggest that $Bio-pin^{(R)}$ bridge restorations using a single $Bio-pin^{(R)}$ are a viable alternative to the conventional 3-unit bridge when minimal removal of sound tooth structure and fulfillment of both function and esthetic aspects are considered.