• 제목/요약/키워드: Super-P

검색결과 462건 처리시간 0.028초

슈퍼 2상 스테인리스강의 공식에 미치는 R상의 영향 (Effect of and R Phase on the Pitting Corrosion in Super Duplex Stainless Steel)

  • 이병찬;오은지;강창룡
    • 한국재료학회지
    • /
    • 제24권11호
    • /
    • pp.610-616
    • /
    • 2014
  • In this study, we investigated the precipitation behavior of the R-phase precipitated at the initial stage of aging and its effect on the pitting corrosion of 25%Cr-7%Ni-4%Mo super duplex stainless steel. The R-phase in super duplex stainless steel was mainly precipitated at the interface of ferrite/austenite phases and inside of the ferrite phase during the initial stage of aging, and it was transformed into the ${\sigma}$-phase with an increase in aging time. The ferrite phase was decomposed into a new austenite phase and ${\sigma}$-phase. The R phase was an intermetallic compound, which represented a lower Ni and higher Mo than the matrix, and also had a higher Mo and Cr concentration than the ${\sigma}$ phase. With an increasing aging time, the pitting potential $E_p$ was increased slowly by the precipitation of the R-phase, and it was then steeply decreased by the precipitation of the ${\sigma}$-phase. The R-phase was decreased the pitting potential, but its effect was smaller than effect of ${\sigma}$-phase.

압축 플랜지에 80MPa급 고강도 콘크리트가 합성된 I형 강거더의 휨거동 특성 (Characteristics of Flexural Behavior of Composite Section Consisting of Steel Girder with 80MPa High Strength Concrete on Compressive Flange)

  • Lee, Juwon;Yang, In-Wook;Lim, Eol;Ha, Tae-Yul;Lee, Kwan-Jong
    • 한국재난정보학회 논문집
    • /
    • 제13권4호
    • /
    • pp.455-464
    • /
    • 2017
  • I형 강거더의 압축부에 SUPER(Sustainable Ultra performing, Pioneering, Economic, Remarkable) Concrete가 합성된 거더의 휨거동 특성을 평가하기 위해 정적재하시험을 수행하였다. 실험체는 총길이 25m, 형고 786mm이고 압축부 콘크리트(이하 케이싱) 강도는 80MPa이며 4점 재하로 하중 2,010kN까지 가력하여 휨거동을 분석하였다. 실험 결과 사용 하중의 2.7배에서 인장 플랜지가 항복하였고 연성비는 1.481였다. 실험 종료까지 케이싱 균열은 확인되지 않았으며 단면 간 상대변위량은 미미한 수준임을 확인하였다.

POSITIVE SOLUTION FOR A CLASS OF NONLOCAL ELLIPTIC SYSTEM WITH MULTIPLE PARAMETERS AND SINGULAR WEIGHTS

  • AFROUZI, G.A.;ZAHMATKESH, H.
    • Journal of applied mathematics & informatics
    • /
    • 제35권1_2호
    • /
    • pp.121-130
    • /
    • 2017
  • This study is concerned with the existence of positive solution for the following nonlinear elliptic system $$\{-M_1(\int_{\Omega}{\mid}x{\mid}^{-ap}{\mid}{\nabla}u{\mid}^pdx)div({\mid}x{\mid}^{-ap}{\mid}{\nabla}u{\mid}^{p-2}{\nabla}u)\\{\hfill{120}}={\mid}x{\mid}^{-(a+1)p+c_1}\({\alpha}_1A_1(x)f(v)+{\beta}_1B_1(x)h(u)\),\;x{\in}{\Omega},\\-M_2(\int_{\Omega}{\mid}x{\mid}^{-bq}{\mid}{\nabla}v{\mid}^qdx)div({\mid}x{\mid}^{-bq}{\mid}{\nabla}v{\mid}^{q-2}{\nabla}v)\\{\hfill{120}}={\mid}x{\mid}^{-(b+1)q+c_2}\({\alpha}_2A_2(x)g(u)+{\beta}_2B_2(x)k(v)\),\;x{\in}{\Omega},\\{u=v=0,\;x{\in}{\partial}{\Omega},$$ where ${\Omega}$ is a bounded smooth domain of ${\mathbb{R}}^N$ with $0{\in}{\Omega}$, 1 < p, q < N, $0{\leq}a$ < $\frac{N-p}{p}$, $0{\leq}b$ < $\frac{N-q}{q}$ and ${\alpha}_i,{\beta}_i,c_i$ are positive parameters. Here $M_i,A_i,B_i,f,g,h,k$ are continuous functions and we discuss the existence of positive solution when they satisfy certain additional conditions. Our approach is based on the sub and super solutions method.

Thermocycling이 금속과 레진시멘트간의 결합강도에 미치는 영향 (THE EFFECT OF THERMOCYCLING ON BOND STRENGTH BETWEEN METAL AND RESIN CEMENT)

  • 강건구;정관호;최정호;안승근;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.233-245
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of thermocycling on bond strength between metal and resin cement according to thermocycling, and to observe the bond failure modes with optical microscope(X30). For this purpose, Super-Bond C & B and Panavia 21 resin cement were used. Metal specimens were made of Vera-Bond and the surface of specimens were sandblasted with $50{\mu}m$ aluminum oxide. All experimental groups were stored in $37^{\circ}C$ distilled water for 72 hours, followed by thermocycling between $5^{\circ}C$ and $55^{\circ}C$ with 15 second dwell time. 500, 1000, 2000 cycles of thermocycling were executed and the tensile bond strength was measured by Instron Universal Testing Machine(Model 4201) The obtained results were as follows : 1. Super-Bond C & B and Panavia 21 did not show statistically significant difference accor-ding to thermocycling test(P>0.05). 2. Super-Bond C & B specimens exhibited statistically significant higher tensile bond stre-ngth than Panavia 21 for all experimental groups(P<0.05). 3. Super-Bond C & B exhibited mixed mode failure with partial adhesive and partial cohe-sive failure, and most of Panavia 21 exhibited cohesive failure and some mixed mode failure.

  • PDF

An electrochemical study of the sealing ability of three retrofilling materials

  • Park, Dong-Sung;Sohn, Suh-Jin;Oh, Tae-Seok;Yoo, Hyun-Mi;Park, Chan-Je;Yim, Soon-Ho;Lee, Young-Kyoo;Kye, Seung-Bum
    • Restorative Dentistry and Endodontics
    • /
    • 제29권4호
    • /
    • pp.365-369
    • /
    • 2004
  • The purpose of this study was to evaluate the apical sealing ability of Super-EBA, MTA and Dyract-flow as retrofilling materials. Forty-eight extracted human teeth with straight and single root canal were used in this study. The root canals were prepared to a #40 apical canal size and obturated with gutter-percha. Apicoectomies were performed and root end cavities were prepared to a depth of 3mm using an ultrasonic device. The root end cavities were filled with Super-EBA, MTA or Dyract-flow. Leakage was measured using an electrochemical technique for 4 weeks. According to this study, the results were as follows. 1. Increasing leakage with time was observed in all groups. 2. No significant difference was noted among the 3 groups with time (p =0.216). 3. No significant difference was noted among the 3 groups when measured within the same time interval (p =0.814). The results of this study suggest that the sealing ability of Dyract-flow is equal to that of Super-EBA and MTA, and Dyract-flow may be an alternative to other materials for root-end filling.

수종의 역충전 재료의 치근단 밀폐력 비교 (COMPARISON OF THE SEALING ABILITY OF VARIOUS RETROGRADE FILLING MAIERIALS)

  • 황윤찬;강인철;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.379-386
    • /
    • 2001
  • This study was performed to evaluate the sealing ability of various retrograde filling materials by using bacterial penetration and dye penetration test. One hundred and forty extracted human teeth with single, straight canals and mature apiece were collected and used for this study. All canals were instrumented using an engine driven Ni-Ti file (ProFile). After removing 3mm from the apex of tooth, a standardized 3mm root end cavity was prepared using an ultrasonic instrument. The 70 teeth were randomly divided into 7 groups : 6 groups for retrograde filling using Super-EBA, ZOE, Chelon-Silver, IRM, ZPC and amalgam. The 7th group was used as a negative control. Nail varnish was applied to all external root surfaces to the level of the reseated root ends to prevent lateral microleakages. The specimens were then sterilized in an ethylene oxide sterilizer for 24 hours. 2 mm of the reseated root was immersed in a culture chamber containing a Tripticase Soy Broth with a phenol red indicator. The coronal access of each specimen was inoculated every 72 hours with suspension of Proteus vulgaris. The culture media were observed every 24hours for color change indicating bacterial contamination. The specimens were observed for 4weeks. The remaining 70 teeth were submitted to a dye penetration test. The canals of all teeth were first sealed with AH26 and obturated using an Obtura II system. Root resection, root end preparation and retrograde filling was performed as above. All specimens were suspended in 2% methylene blue dye for 72 hours before being ion gitudinally split. The degree of dye penetration was then measured using a stereomicroscope at 10 magnification and evaluated. The results were as floows : 1. In the bacterial penetration, the degree of leakage was the lowest in the Super-EBA, followed by, in ascending order, ZOE, Chelon-Silver IRM and ZPC. The amalgam showed highest bacterial leakage of all(p<0.01). 2. In the dye penetration, the degree of microleakage was the lowest in the Chelon-Silver and Super-EBA, followed by, in ascending order, IRM, ZPC. The ZOE and amalgam showed the highest microleakage of all (p<0.05). These results suggested that the eugenol based cement, Super-EBA, have excellent sealing ability as a retrograde filling material.

  • PDF

분광광도법을 사용한 수종 역충전재의 근단부 폐쇄효과에 관한 연구 (SPECTROPHOTOMETRIC EVALUATION OF SEALING EFFECTS OF SEVERAL ROOT-END FILLING MATERIALS)

  • 이진규;박상진;최경규;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제28권6호
    • /
    • pp.449-456
    • /
    • 2003
  • The purpose of this study is to evaluate the sealing effect of several root-end filling materials using spectrophotometric analysis. 180 single root teeth with one canal were instrumented and canal filled. Root resected and root end preparation was made. Teeth were randomly classified to S experimental group(MTA, EBA, IRM, TCP, ZOE) and 1 control group according to root-end filling material MTA group used PRO ROOT MT A, EBA group used Super EBA. TCP group used NEW APATITE LINER TYPE II main component of which is ${\alpha}-tricalcium$ phosphate (TCP). According to manufacture's instruction experimental material was mixed and retrfilled. After 2% methylene blue solution penetration absorbance for each test sample was measured with spectrophotometer (JASCO UV-530, Japan). The mean absorbance of control and experimental group was as follows; MTA: 0.092, IRM: 0.226, Super EBA: 0.255, ZOE: 0.374, Control: 0.425, TCP: 0.501 and the result analyzed by Turkey test at P=0.05 level. Conclusions of this study are as follows; 1. The absorbance increase in following sequence MTA, IRM, Super EBA, ZOE, Control. TCP. 2. MTA showed the least leakage but was not significant with IRM or Super EBA and was significant with control or TCP(p<0.05). 3. TCP had the most leakage and was not significant with control group.

Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study

  • Wong, Uni;Person, Erik B;Castell, Donald O;von Rosenvinge, Erik;Raufman, Jean-Pierre;Xie, Guofeng
    • Journal of Neurogastroenterology and Motility
    • /
    • 제24권4호
    • /
    • pp.570-576
    • /
    • 2018
  • Background/Aims Swallows with viscous or solid boluses in different body positions alter esophageal manometry patterns. Limitations of previous studies include lack of standardized viscous substrates and the need for chewing prior to swallowing solid boluses. We hypothesize that high-resolution impedance manometry (HRiM) using standardized viscous and super-viscous swallows in supine and upright positions improves sensitivity for detecting esophageal motility abnormalities when compared with traditional saline swallows. To establish normative values for these novel substrates, we recruited healthy volunteers and performed HRiM. Methods Standardized viscous and super-viscous substrates were prepared using "Thick-It" food thickener and a rotational viscometer. All swallows were administered in 5-mL increments in both supine and upright positions. HRiM metrics and impedance (bolus transit) were calculated. We used a paired two-tailed t test to compare all metrics by position and substrate. Results The 5-g, 7-g, and 10-g substrates measured 5000, 36 200, and 64 $700mPa{\cdot}sec$, respectively. In 18 volunteers, we observed that the integrated relaxation pressure was lower when upright than when supine for all substrates (P < 0.01). The 10-g substrate significantly increased integrated relaxation pressure when compared to saline in the supine position (P < 0.01). Substrates and positions also affected distal contractile integral, distal latency, and impedance values. Conclusions We examined HRiM values using novel standardized viscous and super-viscous substrates in healthy subjects for both supine and upright positions. We found that viscosity and position affected HRiM Chicago metrics and have potential to increase the sensitivity of esophageal manometry.

계층적 P2P에서의 근거리 기반 효율적 자원관리 기법 (A Locality based Resource Management Scheme for Hierarchical P2P Overlay Network in Ubiquitous Computing)

  • 홍충표;김정길;김신덕
    • 디지털콘텐츠학회 논문지
    • /
    • 제14권1호
    • /
    • pp.89-95
    • /
    • 2013
  • 유비쿼터스 분야에서는 다양한 형태의 P2P 시스템을 분산환경을 위하여 연구하고 있다. 분산해쉬테이블(DHT)기반의 P2P 시스템은 부하조절을 통한 효율적 기법으로 제시되고 있는 반면 이동성과 근거리 기반의 자원 활용을 보장하지는 못하는 문제점을 가지고 있다. 본 연구에서는 이를 극복하기 위하여 이동상황에서의 근거리 기반 P2P 시스템 (MLH-Net)을 제안한다. 이는 이동성에 기반하여 두 개의 계층으로 이루어져 있다. 상위 계층의 경우 super node를 통한 전체적인 관리를 담당하며, 하위 계층의 경우 일반 노드의 망으로 구성되어 있다. 제시하는 방법을 종래의 JXTA 및 Chord 와 비교 실험 한 결과 node의 발견 시 메시지 이동 hop은 JXTA 대비 13% 및 Chord 대비 69% 감소되었으며, 네트워크 거리의 경우도 각각 17% 및 83% 감소되는 효과를 확인 하였다.

$Bio-pin^{(R)}$을 이용한 고정성 보철물의 탈락저항강도의 비교연구 (A COMPARATIVE STUDY OF THE RESISTANCE TO DISLODGEMENT OF FIXED PROSTHESES USING $BIO-PIN^{(R)}$)

  • 이종원;조인호;이종혁;김승기
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.176-190
    • /
    • 2005
  • Statement of problem. The current trend in prosthodontics is the adoption of a conservative approach to preparing dental prostheses by minimizing the amount of sound tooth structure removal during preparation. Purpose. The major disadvantage of the adhesion bridge is the inherently poor resistance to dislodgement that its use in areas subjected to high occlusal load is limited. The purpose of this study was to compare the dislodgement resistance of $Bio-pin^{(R)}$, conventional 3-unit and adhesion bridges. Material and methods. The experimental groups were classified as follows : Group I : 3-unit bridge cemented using $Super-Bond^{(R)}$ C&B Group II : Adhesion bridge cemented using $Super-Bond^{(R)}$ C&B Group III : $Bio-pin^{(R)}$ design adhesion bridge without incorporation of $Bio-pin^{(R)}$ (cemented using $Super-Bond^{(R)}$ C&B) Group IV-1 : $Bio-pin^{(R)}$ retained adhesion bridge incorporating a single $Bio-pin^{(R)}$ (cemented using $Super-Bond^{(R)}$ C&B) Group IV-2 : $Bio-pin^{(R)}$ retained adhesion bridge incorporating a single $Bio-pin^{(R)}$ (cemented using $Panavia^{(R)}$ F) Group V : $Bio-pin^{(R)}$ retained adhesion bridge incorporating two $Bio-pins^{(R)}$ (cemented using $Super-Bond^{(R)}$ C&B) Results. The results of this study were as follows : 1. Significant differences in dislodgement resistance of the restorations were found between Group I, Group II and Group III (p<0.05). No significant differences in dislodgement resistance of the restorations were observed between Group I Group IV-1 and Group V. However, there were significant differences in dislodgement resistance between Group II and the other groups (p<0.05). 2. No significant differences in dislodgement resistance of the restorations were observed between GroupIV-1 and GroupIV-2, both of which utilized a single $Bio-pin^{(R)}$. However, significant differences were observed when Group III was compared to either GroupIV-1 or Group V (p<0.05). 3. No significant differences in dislodgement resistance relative to the type of dental cements used were found. Conclusion. From the above results, it is concluded that the dislodgement resistance of $Bio-pin^{(R)}$ bridge restorations utilizing a single $Bio-pin^{(R)}$ is similar to that of a conventional 3-unit bridge. The results also suggest that $Bio-pin^{(R)}$ bridge restorations using a single $Bio-pin^{(R)}$ are a viable alternative to the conventional 3-unit bridge when minimal removal of sound tooth structure and fulfillment of both function and esthetic aspects are considered.