• Title/Summary/Keyword: Sun: X-rays

Search Result 45, Processing Time 0.026 seconds

Controlling Botrytis elliptica Leaf Blight on Hybrid Lilies through the Application of Convergent Chemical X-ray Irradiation

  • Hong, Sung-Jun;Koo, Tae-Hoon;Yun, Sung-Chul
    • The Plant Pathology Journal
    • /
    • v.32 no.2
    • /
    • pp.77-84
    • /
    • 2016
  • X-ray irradiation with convergent chemicals such as nano-silver particles or sodium dichloroisocyanurate (NaDCC) has been used to control leaf blight on cut lilies. The oriental hybrid lily cultivars Siberia, Le Reve, and Sorbonne were irradiated five times by 200 Gy of X-rays in 2014. In 2015, Siberia and Sorbonne were irradiated three times by 150 Gy of X-rays. After artificial infection with Botrytis elliptica on the leaves and petals of cut lilies, this study used convergent chemical X-ray irradiation of 200 Gy or 150 Gy. Leaf and petal blight was measured in terms of incidence and severity at 8 days after infection using total 552 cuttings. Results indicate that the treatments of X-ray irradiation and NaDCC in 2014 and 2015 slightly decreased the severity of petal blight on Siberia and Sorbonne. However, the results were not significant and severity did not decrease as NaDCC concentration increased. Vase-life was observed separately after X-ray irradiation of 270 cut lilies in 2014 and 108 cut lilies in 2015. Chlorophyll content was not affected by either 200 Gy or 150 Gy of X-rays. The number of days of fully opened flowers at Siberia of 150 Gy and Le Revu of 200 Gy increased by 1-2 days. In addition, the relative fresh weights of the X-rayed flowers were 10% drier than the non-irradiated controls. Overall, leaf blight control by X-ray was inferior to the control by gamma rays, and petal color was bleached in Sorbonne and Le Reve cvs. by 150 Gy of X-rays.

RESULTS FROM THE YOHKOH SATELLITE

  • WATANABE TETSUYA
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.291-294
    • /
    • 1996
  • The .Japanese sun observing satellite, Yohkoh, has been operational for five years and her scientific instruments are still in good condition. They have revealed ample of evidences that solar flares were triggered by magnetic reconnection, which was, for the first time, clearly indicated to take place in the solar corona. Cusp structures in soft X-rays and a new type of hard X-ray sources at the top of flaring loops have strongly supported the scenario originally proposed by C-S-H-KP. Nonthermal energy input in hard X-rays and thermal energy estimated from soft X-rays are fundamentally consistent with the interpretation of thick-target and chromospheric-evaporation models (Neupert effect). X-ray jets, another discovery of Yohkoh, were also associated with magnetic reconnection, as a result of the interaction of emerging fluxes with pre-existing coronal loops. Temperature structures of active regions, quiet sun, and coronal holes had very dynamic differential-emission-measure (DEM) distributions and high-temperature tails of DEM were considered to come from the contribution of flare-like activity.

  • PDF

STUDY OF FLARE-ASSOCIATED X-RAY PLASMA EJECTIONS : II. MORPHOLOGICAL CLASSIFICATION

  • KIM YEON-HAN;MOON Y.-J.;CHO K.-S.;BONG SU-CHAN;PARK Y.-D.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.4
    • /
    • pp.171-177
    • /
    • 2004
  • X-ray plasma ejections often occurred around the impulsive phases of solar flares and have been well observed by the SXT aboard Yohkoh. Though the X-ray plasma ejections show various morphological shapes, there has been no attempt at classifying the morphological groups for a large sample of the X-ray plasma ejections. In this study, we have classified 137 X-ray plasma ejections according to their shape for the first time. Our classification criteria are as follows: (1) a loop type shows ejecting plasma with the shape of loops, (2) a spray type has a continuous stream of plasma without showing any typical shape, (3) a jet type shows collimated motions of plasma, (4) a confined ejection shows limited motions of plasma near a flaring site. As a result, we classified the flare-associated X-ray plasma ejections into five groups as follows: loop-type (60 events), spray-type (40 events), jet-type (11 events), confined ejection (18 events), and others (8 events). As an illustration, we presented time sequence images of several typical events to discuss their morphological characteristics, speed, CME association, and magnetic field configuration. We found that the jet-type events tend to have higher speeds and better association with CMEs than those of the loop-type events. It is also found that the CME association (11/11) of the jet-type events is much higher than that (5/18) of the confined ejections. These facts imply that the physical characteristics of the X-ray plasma ejections are closely associated with magnetic field configurations near the reconnection regions.

Determination of Quality Factors for Cylindrical Ionization Chambers in kV X-rays: Review of IAEA Dosimetry Protocol and Monte Carlo Calculations and Measurements for N23333 and N30001 Chambers (kV X-선에서 원통형전리함의 선질인자 결정에 관한 연구: IAEA 프로토클 고찰과 N23333, N30001 전리함에 대한 몬테칼로 계산 및 측정)

  • Lee Kang Kyoo;Lim Chunil;Chang Sei Kyung;Moon Sun Rock;Jeong Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.53-61
    • /
    • 2005
  • The quality factors for cylindrical ionization chambers for kV X-rays were determined by Monte Carlo calculation and measurement. In this study, the X-rays of 60-300 kV beam (lSO-4037) installed in KFDA and specified in energy spectra and beam qualities, and the chambers of PTW N23333 and N30001 were investigated. In calculations, the $R_{\mu}\;and\;R_{Q,Q_{0}}$ in IAEA dosimetry protocols were determined from the air kerma and the cavity dose obtained by theoretical and Monte Carlo calculations. It is shown that the N30001 chamber has a flat response of $\pm1.7\%$ in $110\~300kV$ region, while the response range of two chambers were shown to $\pm3\~4\%$ in $80\~250kV$ region. From this work we have discussed dosimetry protocol for the kV X-rays and we have found that the estimation of energy dependency is more important to apply dosimetry protocol for kV X-rays.

  • PDF

Development of Data Acquisition System using the Backscattered X-ray (후방산란성 엑스레이를 이용한 데이터 획득 시스템 개발)

  • Hwang, In-Ho;Jung, Jin-Seok;Yuk, Sun-Woo;Yoo, Sun-Kook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.10
    • /
    • pp.129-133
    • /
    • 2009
  • Considerable attention has been focused on digital X-ray systems with transmission. However, only a few attempts have been made using X-ray backscatter systems. This study developed a Data Acquisition System (DAS) for backscattered X-rays. The imaging system used X-ray backscatter at low energy levels, which has unique advantages in terms of acquiring information that cannot be obtained using the transmission system. Such systems are of potential benefit in the medical, industrial, security and military fields because of its practical benefits and the low doses used. The developed system is a similar body scan system. Experiments were carried out using a several metal materials and a fish, which produces results similar to those obtained using the human body during X-ray testing.

A STUDY OF SMALL FLARES ASSOCIATED WITH PLASMA BLOBS OUTFLOWING ALONG POST-CME RAYS

  • Kim, Yoo Jung;Kwon, Ryun-Young;Chae, Jongchul
    • Journal of The Korean Astronomical Society
    • /
    • v.53 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • The recent study of Chae et al. (2017) found a one-to-one correspondence between plasma blobs outflowing along a ray formed after a coronal mass ejection (CME) and small X-ray flares. In the present work, we have examined the spatial configuration and the eruption process of the flares that are associated with the blobs by analyzing EUV images and magnetograms taken by the SDO/AIA and HMI. We found that the main flare and the successive small flares took place in a quadrupolar magnetic configuration characterized by predominant magnetic fields of positive polarity, two minor magnetic fragments of negative polarity, and a curved polarity inversion line between them, which suggests that the formation process of the blobs may be similar to that of the parent CME. We also found that the successive flares resulted in a gradual change of the quadrupolar magnetic configuration, and the relevant migration of flaring kernels. The three-dimensional geometry and the property of the current sheet, that is often supposed to be embedded in an observed post-CME ray, seem to keep changing because of mutual feedback between the successive flares and the temporal change of the magnetic field configuration. Our results suggest that the observed post-CME rays may not reflect the characteristics of the current sheet responsible for the impulsive phase of the flare.

Commissioning of a micro-MLC (mMLC) for Stereotactic Radiosurgery (방사선수술용 4뱅크 마이크로 다엽콜리메이터의 인수 검사)

  • Jeong, Dong-Hyeok;Shin, Kyo-Chul;Kim, Jeung-Kee;Kim, Soo-Kon;Moon, Sun-Rock;Lee, Kang-Kyoo
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2009
  • The 4 bank mico-MLC (mMLC; Acculeaf, Direx, Isral) has been commissioned for clinical use of linac based stereotactic radiosurgery. The geometrical parameters to control the leaves were determined and comparisons between measured and calculated by the calculation model were performed in terms of absolute dose (cGy/100 MU). As a result of evaluating calculated dose for various field sizes and depths of 5 and 10 cm in water in the geometric condition of fixed SSD (source to surface distance) and fixed SCD (source to chamber distance), most of differences were within 1% for 6 MV and 15 MV x-rays. The penumbral widths at the isocenter were approximately evaluated to 0.29~0.43 cm depending on the field size for 6 MV and 0.36~0.51 cm for 15 MV x-rays. The average transmission and leakage for 6 MV and 15 MV x-rays were 6.6% and 7.4% respectively in single level of leaves fully closed. In case of dual level of leaves fully closed the measured transmission is approximately 0.5% for both 6 MV and 15 MV x-rays. Through the commissiong procedure we could verify the dose characteristics of mMLC and approximately evaluate the error ranges for treatment planning system.

  • PDF

Production of clothes for beach volleyball players: Safe against ultraviolet radiation damage

  • He Huang
    • Geomechanics and Engineering
    • /
    • v.32 no.6
    • /
    • pp.627-637
    • /
    • 2023
  • Volleyball is an international sport with many fans. This sport has made significant progress in schools and clubs. Volleyball is suitable for all age groups and can be used in different environments. It has many social and physical benefits. During the game provides special physical training for the players and is considered one of the most exciting games. Another type of volleyball is beach volleyball, a beach sport and one of the Olympic sports held on the sand with the same rules as volleyball. This sport is usually played in coastal areas, especially with wide sandy beaches. Because this sport is played in open spaces, the players stay in this space for a long time and are exposed to dangerous ultraviolet radiation. It is a wavelength of light in the range of electromagnetic waves with a wavelength between 10 and 400 nm. This wavelength is shorter than visible light and more protracted than X-ray. Ultraviolet (UV) rays are naturally present in sunlight and include about 10% of all waves emitted from the sun's surface. Prolonged exposure to ultraviolet light causes acute and chronic damage to the skin and vision and even destroys the entire immune system. Different covers of the earth's surface reflect different amounts of UV rays. For example, snow cover, sand, and seawater surface reflect this radiation. Therefore, the health of volleyball players is in danger due to this harmful radiation. This work aims to introduce a type of clothing made of nanoparticles that can repel ultraviolet rays and protect beach volleyball players whose health is at risk from this radiation.

Central Axis Percentage Depth-Dose in a Water Phantom Irradiated by Conventional X-rays (Water Phantom 속 Conventional X-ray 중심축상의 깊이 선량 백분율)

  • Kim, Wuon-Shik;Hah, Suck-Ho;Hwang, Sun-Tae;Oh, Jang-Jin;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 1987
  • Central axis percentage depth-doses, P(%), were measured at the points from the 2.5cm depth of reference point to 20 cm depth with 2.5 cm interval. Distance from the X-ray target to the water phantom($30{\times}30{\times}30cm^3$) surface was 1 m, and at this point three different beam sizes of $5cm{\phi},\;10cm{\phi},\;and\;15cm{\phi}$ were used. While the X-ray tube voltage varied from 150 to 250 kV, the tube current remained constant at 5 mA. Absorbed dose rate in water, $\dot{D}_w$, was determined using the air kerma calibration factor, $N_k$, which was derived from the exposure calibration factor, $N_x$, of the NE 2571 ion chamber. The reference exposure rate, $\dot{X}_c$, was measured using the Exradin A-2 ion chamber calibrated at ETL, Japan. The half value layers of the X-rays determined to meet ETL calibration qualities. The absorbed dose rates determined at the calibration point were compared to the values obtained from Burlin's general cavity theory, and the percentage depth-dose values determined from $N_k$ showed a good agreement with the values of the published depth dose data(BJR Suppl. 17).

  • PDF

Effect of Light Quality on Appearance of Photobleaching leaves During the Cure of Burley Tobacco (Burley종 잎담배 건조시 광질이 백화엽 발생에 미치는 영향)

  • Bae, Seong-Kook;Lim, Hae-Geon;Kim, Yo-Tae;Yu, Ik-Sang;Choi, Sun-Young
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 1985
  • This experiment was designed to determine the effect of light quality on the appearance of photobleaching leaves during the cure of Burley Tobacco. The harvested and browned tobacco leaves were exposed to sunlight in pipe houses covered with 8 kinds of color vinyls (white, red, black, yellow, purple, orange, blue, green), and exposed to ultraviolet rays(20W x 3) and infrared rays (150W x 2) in curing chamber (1.2 x 1.2 x 1.2m). Photobleaching occured more at lower position leaf and after the leaves being browned when the curing was done in sunlight under a transparent vinyl. But photobleaching leaves were 5-6% of total cured leaves in sunlight under all kinds of color vinyl houses. It seems that photobleaching mainly induced by ultrabiolet rays of sunlight, and humidity too influenced. Yellow, orange and purple vinyl were durable and effective as shading material of color vinyls. since white and red vinyl tore easily in two monthes in strong sunlight and under black and blue vinyl houses curing period was longer than others.

  • PDF