• Title/Summary/Keyword: Sump water

Search Result 42, Processing Time 0.03 seconds

Debris transport visualization to analyze the flow characteristics in reactor vessel for nuclear power plants

  • Song, Yong Jae;Lim, Dong Seok;Heo, Min Beom;Kim, Beom Kyu;Lee, Doo Yong;Jo, Daeseong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4003-4013
    • /
    • 2021
  • During the long-term cooling (LTC) phase of a loss-of-coolant accident (LOCA) in a pressurized water reactor (PWR), water is supplied from the containment sump to the reactor coolant system (RCS) by the flooded sump water to the Reactor Vessel (RV) through the broken pipes. As part of the technical efforts for resolving GSI-191 [( Reid and Crytzer, May. 2007) 1, consideration is needed for the consequences of debris penetrating the sump screen and propagating downstream into the RV. Injection of debris (fiberglass) into the RV during the LTC recirculation phase needs special attention to assure that reactor core cooling is maintained. The point of concern is the potential for debris to adversely affect the reactor core flow paths or heat transfer [2]. However, all the experiments for proving the coolability of RV have been done with the assumption of the most of debris would be transferred to the RV and the bottom nozzle of the FAs. The purpose of the tests is to quantify the amount of the debris that would be accumulated at the lower plenum and the debris that passes through the FAs since non-conservatism of other researches assumptions that have been used in the past experimental or analytical programs.

Visualization of Air Absorption Induced by Free Surface Vortex in the Pump Sump Using Multi-phase Flow Simulation (펌프 섬프장내 자유표면 보텍스에 의한 공기흡입 현상의 가시화)

  • Park, Young-Kyu;Li, Kui. Ming.;Choi, Yoon-Hwan;Lee, Yeon-Won
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.3
    • /
    • pp.59-64
    • /
    • 2011
  • In this study the change of free surface vortex is expressed through the time volume fraction using multiphase unsteady condition in sump, because in previous studies of the pump sump did not represent the behavior of the free surface vortex exactly due to the reason it was calculated using single phase and steady condition. The reliability of the computational analysis is verified through comparing experimental results with that of present numerical analysis. Homogeneous free surface model is used to apply interactions of air and water. The results show that the free surface vortex can be identified on the isotropic surface at air volume fraction 1%~5%. The vortices make an air column from the free surface to the sump intake and are created and destroyed repeatedly. The behavior of free surface vortex at numerical analysis is quite similar to experimental test. The result of vortex motion according to time, works on a cycle.

Study on Surface Vortices in Pump Sump

  • Long, Ngo Ich;Shin, Byeong Rog;Doh, Deog-Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.5
    • /
    • pp.60-66
    • /
    • 2012
  • One of commonly physical phenomena encountered in pump sump systems in which its significant influence to the hydraulic performance of pump system plays an important role in the field of fluid engineering, is the appearance of free surface and submerged vortices. In this paper, a study of the vortices behavior and their formative mechanism of asymmetry is considered in this paper by using numerical approach. The Reynolds-Averaged Navier-Stokes (RANS) equations and k-omega Shear Stress Transport turbulence model used to describe the properties of turbulent flows, in company with VOF multiphase model, are implemented by Fluent code with multi-block structured grid system. In the numerical simulation, the calculated elevation of air-water interface and vortex core contours are used to classify visually surface vortices as well as submerged vortices. It is shown that the free surface vortex is identified by the concavity of liquid region from the free surface and swirling flow at that own plane. To investigate the distinctive behavior of these vortices corresponding to each given flow rate at the same water level, some numerical testing of them are considered here in such a manner that the flow pattern of surface vortex are obtained similarly to the obtained results from experiment. Furthermore, the influence due to the change of grid refinement and the variation of depth of the concavity are also considered in this paper. From that, these influential factors will be implemented to design a good pump sump with higher performance in the future.

Numerical Analysis on the Flow Vortex in a Multi Pump Intake using a Pump Sump Model (다중 펌프 흡수정에서 발생하는 Vortex 수치 해석에 관한 연구)

  • Park, No-Suk;Kim, Seong-Su;Hyun, Sang-Rak;Park, Jong-Ho;Ahn, Young-Seog
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.211-217
    • /
    • 2010
  • In order to suggest the methodology for achieving anti-vortex within multi pump intake well, the field test and CFD(Computational Fluid Dynamics) simulation were conducted. The filed test were carried out for domestic W_multi pump intake well according to usual operation condition through the naked observation. From the results, operating #4, #5, #8 and 9# pumps, the vortex and swirl occurred above #4 and #9 intake pipe within two wells. For qualitative analysis, a commercial CFD code, using sump model, was used to predict the vortex generation within the selected pump intake facility accurately. The analysed results by CFD show that the vortex structure and location are in accordance with the results of the field test.

Impedance investigation of the surface film formed on aluminum alloy exposed to nuclear reactor emergency core coolant

  • Junlin Huang;Derek Lister;Xiaoliang Zhu;Shunsuke Uchida;Qinglan Xu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1518-1527
    • /
    • 2023
  • A method was proposed for in-situ evaluating the thickness and resistivity of the oxide/hydroxide film formed on the surface of aluminum alloy exposed to sump water formed in the containment after a loss-of-coolant accident. The evaluation entailed fitting a model for the film impedance, which has film thickness and other variables describing the resistivity profile of the film along its thickness direction as fitting parameters, to the practically measured electrochemical impedance data. The obtained resistivity profiles implied that the films formed at pHs25℃ 7, 8, 9, 10, and 11 all had a duplex structure; compared to the outer layer in contact with the solution, the inner layer of the film had a much higher resistivity and was inferred to be denser and provide most of the protectiveness of the film. Both the thickness and the total resistance of the film decreased with the increasing solution pH25℃, suggesting that the films formed in more alkaline solutions had less protectiveness against corrosion, consistent with the increasing aluminum alloy corrosion rates previously identified.

Relative humidity prediction of a leakage area for small RCS leakage quantification by applying the Bi-LSTM neural networks

  • Sang Hyun Lee;Hye Seon Jo;Man Gyun Na
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1725-1732
    • /
    • 2024
  • In nuclear power plants, reactor coolant leakage can occur due to various reasons. Early detection of leaks is crucial for maintaining the safety of nuclear power plants. Currently, a detection system is being developed in Korea to identify reactor coolant system (RCS) leakage of less than 0.5 gpm. Typically, RCS leaks are detected by monitoring temperature, humidity, and radioactivity in the containment, and a water level in the sump. However, detecting small leaks proves challenging because the resulting changes in the containment humidity and temperature, and the sump water level are minimal. To address these issues and improve leak detection speed, it is necessary to quantify the leaks and develop an artificial intelligence-based leak detection system. In this study, we employed bidirectional long short-term memory, which are types of neural networks used in artificial intelligence, to predict the relative humidity in the leakage area for leak quantification. Additionally, an optimization technique was implemented to reduce learning time and enhance prediction performance. Through evaluation of the developed artificial intelligence model's prediction accuracy, we expect it to be valuable for future leak detection systems by accurately predicting the relative humidity in a leakage area.

Analysis of Post-LOCA pH for Korea Nuclear Units (국내 원자력발전소의 LOCA사고에 따른 pH 분석)

  • Hyung Won Lee;Yung Hee Kang;Jae Hee Kim
    • Nuclear Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.179-187
    • /
    • 1983
  • The pH of containment spray and sump water following a LOCA for KNU 5'||'&'||'6 and KNU 1 was calculated to see if pH design criteria of containment spray system established by USNRC were met. The pH calculations have been made for the two cases; maximum pH and minimum pH. For KNU 5'||'&'||'6, results showed that long term sump pH values calculated for the maximum pH and minimum pH case well met the pH requirement of at least 8.5 and spray pH for the maximum case slightly exceeded the range of design criteria (8.5 to 11.0). For KNU 1, pH requirement of long term sump pH was also met, however, spray pH value for the maximum pH case was very largely greater than that of current pH requirement. (No pH requirement of containment spray water has been established at the time of designing KNU 1) In order to find the design parameters of containment spray system which are expected to meet the spray pH requirement, several calculations were wade, by changing the input parameters to "LCCAPH". Finally, it was shown that the boric acid concentration in RWST (refueling water storage tank), which was the primary sources of containment spray water during injection mode, be maintained the range of 2750 ppm to 2850 ppm, or tile flow rate of NaOH added to spray water he kept between 10 gpm to 24 gpm.

  • PDF