• 제목/요약/키워드: Sulfur Corrosion

검색결과 98건 처리시간 0.021초

Study on the Sulfide Corrosion to the Internal Surface of Transportation Pipeline

  • Zhang, Yiling;Qi, Ping;Kong, Dehong
    • Corrosion Science and Technology
    • /
    • 제7권4호
    • /
    • pp.193-196
    • /
    • 2008
  • This article briefly tests and analyzes the sulfur content and the distribution of active sulfur in the crude oil of Kurkow Kazakhstan and Siberian Russian, and discusses the relationship between active sulfur content and total sulfur content, active sulfur and corrosion. At the same time, it measures the open circuit potential of X70 steel and X60 steel witch have been immerged in the above two kind of crude oil for a period of time, discusses the sulfur corrosion to metal.

Corrosion Behavior of Carbon Steel in Diluted Sulfuric Acid based on Seawater

  • Kim, Mun Su;Jeong, Jin-A
    • Corrosion Science and Technology
    • /
    • 제18권3호
    • /
    • pp.78-85
    • /
    • 2019
  • The International Maritime Organization (IMO) will administer a new 0.5% global sulfur cap on fuel content from 1 January 2020, lowering from the present 3.5% limit. Seawater $SO_x$ (sulfur oxide) scrubbing is especially spray scrubbing and a promising alternative to complying with the IMO regulation. However, the ionization of $SO_2$ (sulfur dioxide) and the $H_2SO_4$ (sulfuric acid) formed from $SO_3$ (sulfur trioxide) is proposed to accelerate corrosion of the internal seawater pipe. Apparently, the corrosion of the scrubber seawater piping system occurs in a severe and frequent manner. Hence, in this study, electrochemical measurement and weight loss of carbon steel (used as seawater pipe in most of the ships) in diluted sulfuric acid solution were investigated to determine corrosion rate, corrosion current density, corrosion potential, electrochemical behavior, and impressed-current density. Accordingly, the corrosion rate of carbon steel sheet in various diluted sulfuric acid solutions was observed to be greater than that in natural seawater, thus suggesting the fundamental data to deal with corrosion problems in scrubber seawater pipe.

생화학적 부식 인공촉진시험에 의한 항균모르타르의 항균성능 평가 (Antibiosis Evaluation of Antimicrobial Mortar by Artificial Accelerating Test for Biochemical Corrosion)

  • 구경모;신관수;노경민;이의배;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.33-36
    • /
    • 2007
  • In this study, an antibiosis of antimicrobial mortar developed to reduce biochemical corrosion of sewage facilities concrete was evaluated. First, artificial acceleration test reflecting similarly biochemical corrosion of mortar was developed. Antimicrobial mortar specimen were experimented in this test and antibiosis of it was evaluated by SEM and EDX. As a results of the study, sulfur-oxidizing bacteria on the plain specimen were survived for 20 weeks in this test. But sulfur-oxidizing bacteria on antimicrobial specimen were survived less than the plain, and sulfur-oxidizing bacteria were externally distorted and destroyed. So the antibiosis of an antimicrobial mortar was verified by it.

  • PDF

Corrosion of Silver by Outgassing from Rubber

  • Sakai, Jun'ichi;Omoda, Masataka;Ishikawa, Yuichi
    • Corrosion Science and Technology
    • /
    • 제7권2호
    • /
    • pp.130-133
    • /
    • 2008
  • Corrosion of silver by outgassed sulfur species from rubber has been investigated by means of quartz crystal microbalance technique (QCM) and cathodic reduction technique. Silver specimens were placed together with a rubber of predefined quantity in an enclosed environment. Corrosion progressed linearly with time and silver sulfide was found as the corrosion product during all the tests. No significant dependence on RH was observed, while the corrosion rate increased as temperature rose. Furthermore the corrosion rate increased logarithmically with the quantity of the rubber placed in the exposure environment. It may be suggested that the corrosion rate of silver is determined by the amount of outgassed sulfur species which is a function of temperature and the quantity of rubber contained in the exposure environment.

Corrosion of Steel and Zinc in Tropics

  • Hue Nguyen Viet;Kwon Sik Chol
    • 한국표면공학회지
    • /
    • 제36권3호
    • /
    • pp.272-283
    • /
    • 2003
  • Mild steel and zinc specimens were tested in five atmospheric testing sites of Vietnam in order to collect the corrosion databank as well as to study the corrosion mechanism in tropical conditions, in period of 1997-2000. The results obtained showed that the corrosion rate of steel is in the range of $10-50\;{\mu}m/year$ and of zinc is of $1-5\;{\mu}m/year$. They are interpretable in the comparison with the data obtained in different countries in the South East Asian as well as previous reports of Vietnamese nation project In atmospheric corrosion. The main factors affecting the corrosion in Vietnam tropical conditions are TOW (time of wetness) and salinity. The relationship between sulfur dioxide and corrosion of metals, particularly, zinc was not found clearly. An explanation was suggested about the complex effect of different pieces present in tropical atmosphere and about the alternative of the dominant factors such as humidity, salinity or temperature.

질산가스분위기에서 황산 양극산화 피막처리된 Al6070 합금의 부식특성 (Corrosion Characteristics of the Sulfuric Acid Anodized Film Formed on Al6070 Alloy in Nitric Acid Vapor Environment)

  • 장일호;정도영;국진선
    • 한국표면공학회지
    • /
    • 제45권5호
    • /
    • pp.198-205
    • /
    • 2012
  • The corrosion properties of anodized films on aluminium 6070 alloy in a sulfuric acid have been studied. Comparison to evaluate the anodized A6070 and pure 6070 specimen, corrosion tests in $HNO_3$ vapor environment of the 20 wt.% were performed up to 72 hours. Characteristics of film formation and surface morphology were examined by optical microscopy, FE-SEM, and EDS. The oxide film anodized in the sulfuric acid solution contained 5 to 10 wt.% of sulfur. In the initial stages of corrosion, anodized specimens exhibited corrosion resistance than the pure specimen. However, the corrosion conditions in 24 hours, corrosion was far more anodized specimen than pure specimen. Therefore, anodized films contained sulfur, nitric acid vapor in the environment is thought to stimulate corrosion.

Effects of Sulfur Segregation on Tertiary Recrystallization Kinetics in Thin-gauged 3% Si-Fe Electrical Strip

  • Chai, K.H.;Na, J.G.;Heo, N.H.;Kim, J.C.;Lee, S.R.;Woo, J.S.
    • Journal of Magnetics
    • /
    • 제4권1호
    • /
    • pp.5-9
    • /
    • 1999
  • Effect of sulfur segregation on tertiary recrystallization and magnetic induction during final annealing was investigated in a 3% Si-Fe electrical strip containing 6 ppm(LS) and 15 ppm(HS) sulfur. During final annealing, Auger peak height of segregated sulfur on the surface of the strips reached a maximum, and then decreased to low level with increasing annealing time, which is attributed to sulfur segregation and evaporation. The magnetic induction of the thin-gauged 3% Si strip was inversely proportional to the Auger peak height of segregated sulfur on the surface. The overall profile for surface segregation of sulfur and B10 was observed, irrespective of sulfur content in Si-Fe strips, but the peaks of LS strips appeared earlier than those of HS strips. The grain growth rate of the LS strips during final annealing was faster than that of the HS strips, which may be attributed to the pinning effects of segregated sulfur. With increasing final annealing temperature, B10 value increased rapidly and the saturation level in B10 increased.

  • PDF

Design of Copper Alloys Preventing Grain Boundary Precipitation of Copper Sulfide Particles for a Copper Disposal Canister

  • Minkyu Ahn;Jinwoo Park;Gyeongsik Yu;Jinhyuk Kim;Sangeun Kim;Dong-Keun Cho;Chansun Shin
    • 방사성폐기물학회지
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2023
  • The major concern in the deep geological disposal of spent nuclear fuels include sulfide-induced corrosion and stress corrosion cracking of copper canisters. Sulfur diffusion into copper canisters may induce copper embrittlement by causing Cu2S particle formation along grain boundaries; these sulfide particles can act as crack initiation sites and eventually cause embrittlement. To prevent the formation of Cu2S along grain boundaries and sulfur-induced copper embrittlement, copper alloys are designed in this study. Alloying elements that can act as chemical anchors to suppress sulfur diffusion and the formation of Cu2S along grain boundaries are investigated based on the understanding of the microscopic mechanism of sulfur diffusion and Cu2S precipitation along grain boundaries. Copper alloy ingots are experimentally manufactured to validate the alloying elements. Microstructural analysis using scanning electron microscopy with energy dispersive spectroscopy demonstrates that Cu2S particles are not formed at grain boundaries but randomly distributed within grains in all the vacuum arc-melted Cu alloys (Cu-Si, Cu-Ag, and Cu-Zr). Further studies will be conducted to evaluate the mechanical and corrosion properties of the developed Cu alloys.

항균 콘크리트를 적용한 정화조 및 하수처리 콘크리트 구조물의 황산화세균에 의한 생화학적 부식 저감 기술 (Technology for Controlling Biochemical Corrosion by Sulfur-oxidizing Bacteria of Sewage Concrete Construction applied Antimicrobial Concrete)

  • 김도수;길배수;손유신;이승훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.907-910
    • /
    • 2008
  • 최근 콘크리트로 대부분 시공되는 정화조 및 하수구조물은 황산화세균에 의한 생화학적 부식반응에 의해 심각하게 열화되고 있는 실정이다. 이러한 생화학적 부식방지를 위해서는 하수환경에 서식하는 황산화세균의 생장을 서식하는 생화학적 부식을 억제하는 항균제를 적용한 항균 콘크리트 적용기술이 필수적으로 개발되고 적용되어야만 한다. 이에 본 연구에서는 항균 콘크리트의 항균특성에 의해 하수환경에 노출된 하수구조물의 생화학적부식을 효과적으로 억제할 수 있는 기술을 소개하고자 한다.

  • PDF

내부식성 콘크리트 개발을 위한 기초연구로서 개질유황 혼합 콘크리트의 물성 평가 (Evaluation on the Properties of Modified-sulfur Concrete as a Basic Study for Development of Anti-corrosive Concrete)

  • 박상순;나옥정
    • Corrosion Science and Technology
    • /
    • 제15권1호
    • /
    • pp.28-37
    • /
    • 2016
  • Due to the increased construction of offshore concrete structures and the use of de-icing salts for the purpose of snow removal, the needs for the development of anti-corrosive concrete are increasing. To solve these problems, an evaluation of the mechanical and durability properties for concrete were conducted by mixing modified-sulfur as 0 %, 5 %, 10 %, 15 % cement weight ratio. Both strengths and the properties affecting durability such as water absorption coefficient, chloride ion permeability, accelerated carbonation resistance, rapid freezing and thawing, and chemical resistance were evaluated. All evaluations performed were according to the test specifications associated KS. The results indicate that mixing of modified-sulfur lowed chloride ion permeability and improved chemical resistance.