• Title/Summary/Keyword: Suffocation

Search Result 81, Processing Time 0.033 seconds

Development of Benthic Community on an Artificial Reef Complex, Jeju Island, Korea

  • Yi, Soon-Kil;Huh, Hyung-Tack;Je, Jong-Geel;Kim, Dae-Gwen
    • Ocean and Polar Research
    • /
    • v.23 no.3
    • /
    • pp.255-264
    • /
    • 2001
  • Development process of benthic community on experimental substrata attached on a newly installed artificial reef complex in Jeju Island was observed for 27 months from 1992 to 1994. Among 34 species of algae and 64 species of zoobenthos obtained from the study, Ecklonia cava dominated with a maximum biomass of about $10kg/m^2$. It was able to smother the other animals, however it provided a new substrate for the new settlers. Opportunistic bryzoans such as Likenopora radiata and Dexiospira spirillum occurred during the early stage were substituted by poriferans, banacles and other bryzoans. Young barnacles were smothered by bryozoans, on the contrary, bryozoans were bulldozed by adult barnacles. No apparent differences have been observed between vertically and horizontally installed substrates in terms of species composition and biomass during the early stage of succession. Thereafter owing to the rapid growth of E. cava, the horizontal substrata carried on a higher biomass while the vertical showed a higher coverage. The benthic process on the experimental substrata can be classified into three stages: initial stage, build up stage and regulatory stage. Important mechanisms involved were canopying of E. cava, suffocation by bryozoans and poriferans, and bulldozing of adult barnacles.

  • PDF

Oxygen contents monitoring in the building for launch and test facilities (발사대 및 시험장 건물 내의 산소농도 관리)

  • Kim, Ji-Hoon;Yoo, Byung-Il;Cho, Sang-Yeon;Kang, Sun-Il;Oh, Seung-Hyub
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.246-249
    • /
    • 2009
  • Test and launch facilities which use oxygen as the propellant of a launch vehicle have hazards of fire and explosion by the leakage of oxygen. Also, the personnel operating the facilities, which use the high-pressured gases like nitrogen and helium in the closed room, is exposed to the hazard of death from suffocation. Consequently, we should keep out of the hazards and the accidents by monitoring the contents of oxygen in the air. The method and the system construction for monitoring oxygen contents in the air and the results from its application to Naro space center are described on this paper.

  • PDF

Risk Factors for Sudden Infant Death Syndrome and Sleeping Practices in Korea

  • Ahn, Young Mee;Yang, Kyung-moo;Ha, Hong Il;Cho, Jung Ae
    • Child Health Nursing Research
    • /
    • v.26 no.1
    • /
    • pp.82-89
    • /
    • 2020
  • Sudden infant death syndrome (SIDS) in Korea remains a poorly-understood subject for both professionals and the public. Recent reports have emphasized ethnic differences in SIDS rates, suggesting that making adjustments in child-rearing practices may contribute substantially to SIDS reduction. Two of the three major risk factors for SIDS-vulnerability of the infant and exogenous factors-need to be understood in particular depth due to their broad scope and sociocultural grounding. This paper presents substantial issues regarding preterm birth and male gender on infants' vulnerability to SIDS in Korea. Practices of caring for healthy infants are addressed in the context of sleeping practices, including sleeping position, bedding arrangements, sleeping on the floor, the back-to-sleep position, high indoor temperatures and ondol floor heating, and swaddling. Professional and social awareness about how to reduce SIDS should be raised by promoting a better understanding of risk factors in the context of ethnic and cultural variations in child-rearing practices.

Effects of Spray Characteristics of Water Mist on The Extinction of a Liquid Pool Fire (분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향)

  • Kim, Ho-Young;Oh, Sang-Youp;Chung, Jin-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1591-1599
    • /
    • 2004
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is a small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is l15∼180${\mu}{\textrm}{m}$ with nozzle A and 130∼190${\mu}{\textrm}{m}$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of $O_2$ concentration.

The Effects of Spray Characteristics of Water Mist on the Fire Suppression of Liquid Pool Fire (미분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향)

  • Oh, Sang-Youp;Kim, Ho-Young;Chung, Jin-Taek
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.215-221
    • /
    • 2003
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is $115{\sim}180{\mu}m$ with nozzle A and $130{\sim}190{\mu}m$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of O2 concentration.

  • PDF

Assessment of Flame Retardancy for Acrylonitrile Butadiene Styrene Containing Metal Powder and Flame Retardant (금속분말-난연제 함유 ABS의 난연 특성 평가)

  • Song, Young-Ho;Chung, Kook-Sam
    • Fire Science and Engineering
    • /
    • v.21 no.2 s.66
    • /
    • pp.30-35
    • /
    • 2007
  • The flame retardancies by the addition of metal powder and flame retardant were evaluated to present as the fundamental data to decrease the fire hazard of polymers and life losses by suffocation and poisoning. For this study, the experiments of flame retardancy were conducted as follows : weight loss rate using thermogravimetric analysis, the measurement of the limiting oxygen index(LOI) and char yield. And smoke mass concentration and CO yield were measured. Acrylonitrile butadiene styrene containing metal powder and flame retardant reduced weight loss rate and increased LOI and char yield with the decreased smoke mass concentration and CO yield. It was found that the most effective complex was tricresyl phosphate-Mo complex.

Experience of Hemodialysis in the Chronic Renal Failure Clients (만성신부전 환자들의 혈액투석 경험)

  • Shin Mi-Ja
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.3 no.2
    • /
    • pp.235-246
    • /
    • 1996
  • The purpose of this study was to discover the experience of hemodialysis which clients confronted hemodialysis at the same time as CRF diagnosis and to understand the nature and meaning of their crisis experience. The research subjects were 6 clients receiving hemodialysis in Seoul from Jan. 1996 to Jul. 1996. Data were collected by informal indepth interview and participant observation. Content Analysis(by Seaman & Verhonick, 1982; Woods & Catanzaro, 1988) was applied to collect similar contents and common experience in order to derivate concepts and categories for better understanding of their hemodialysis experience. As a result, 6 categories derivated to indentify their hemodialysis experience of the CRF clients-confronted hemodialysis at the same time as CRF diagnosis-were as follows: 1) The category of shocking crisis composed the concepts of shock, amagement and suffocation. 2) The category of denial composed the concepts of disease refusal and hemodialysis refusal. They repeatedly visited hospitals or didn't visit hospital in order to refuse disease, then depended on folk remedy or shamanistic method. 3) The category of severe anxiety composed the concepts of abandoned feeling, shame, resentment, neurosis and anger. 4) The category of depression composed the concepts of grief, suffering of unfairness, tearing, desire to death. 5) The category of powerlessness composed the concept of hopelessness. 6) The category of resigned acceptance composed the concepts of resignation and acceptance. In this study, the CRF clients who confronted hemodialysis at the same time as CRF diagnosis experienced six stages in accepting hemodialysis but these stages were mingled simultaneously and went on.

  • PDF

Preparation of melamine-grafted graphene oxide and evaluation of its efficacy as a flame retardant additive for polypropylene

  • Monji, Parisa;Jahanmardi, Reza;Mehranpour, Milad
    • Carbon letters
    • /
    • v.27
    • /
    • pp.81-89
    • /
    • 2018
  • The present study aimed to prepare a novel efficient flame retardant additive for polypropylene. The new flame retardant was prepared by chemical grafting of melamine to graphene oxide with the aid of thionyl chloride. Fourier-transform infrared spectroscopy and thermogravimetric analysis proved that melamine had been successfully grafted to the graphene oxide. The modified graphene oxide was incorporated into polypropylene via solution mixing followed by anti-solvent precipitatio. Homogeneous distribution as well as exfoliation of the nanoplatelets in the polymer matrix was observed using transmission electron microscopy. Thermogravimetric analysis showed a significant improvement in the thermo-oxidative stability of the polymer after incorporating 2 wt% of the modified graphene oxide. The modified graphene oxide also enhanced the limiting oxygen index of the polymer. However, the amount of improvement was not enough for the polymer to be ranked as a self-extinguishing material. Cone calorimetry showed that incorporating 2 wt% of the modified graphene oxide lowered total heat release and the average production rate of carbon monoxide during burning of the polymer by as much as 40 and 35%, respectively. Hence, it was concluded that the new flame retardant can retard burning of the polymer efficiently and profoundly reduce suffocation risk of exposure to burning polymer byproducts.

Characterization of odourous compounds in air, leachate, stream and well in and around Taju-Bello Dumpsite, Lagos, Nigeria

  • Azeez, L.;Oyedeji, O.A.;Abdulsalami, I.O.;Adewuyi, S.O.
    • Advances in environmental research
    • /
    • v.2 no.2
    • /
    • pp.143-153
    • /
    • 2013
  • This study investigated the concentrations of odourous compounds in air, leachate, stream and well in and around Taju-Bello dumpsite. Meteorological parameters (temperature, relative humidity, wind velocity) and six odour families comprising sulphur ($H_2S$), ammonia ($NH_3$), aromatic (benzene, toluene, ethylbenzene, styrene, p-xylene, m-xylene), aliphatic (hexane), oxygenated (formaldehyde, acetaldehyde) and halogenated (tetrachloroethene, trichloroethene, carbontetrachloride) compounds were measured. Meteorological parameters suggested low dispersal of pollutants at L1 with possible perspiration and suffocation from exposure to high temperature, relative humidity and low wind velocity. The trend of abundance of odourous compounds at studied locations is of the order dumpsite (L1) > leachate (L4) > 100 m away from dumpsite (L2) > 200 m away from dumpsite (L3) > stream (L5) > well (L6). $H_2S$, Oxygenated and aromatic compounds were the major contributors to odour strength in these locations. Correlation, factor and cluster analyses of the data revealed similarities of sources as biogenics and xenobiotics inherent in the wastes as the main sources of these odourous compounds.

A Study on the Development of ICT-based Disaster Prevention Monitoring System for Shipbuilding Safety (선박 안전 건조를 위한 ICT 기반 재해방지 감시시스템 개발에 관한 연구)

  • Kim, Gi-Back;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.785-788
    • /
    • 2014
  • Even though Korea is No.1 shipbuilding country around the world, there have been a lot of accident and man-made calamity incurring in shipyards these days. Therefore most of Korea major shipyard and mid-small size shipyard deeply agonize about safety management countermeasure. As a result of it, many shipyards pour their effort on developing man watching system, PF wireless communication system, portable measuring system to prevent from accident such as fire, suffocation incurring. In this paper, analyze conventional accident & man-made calamity preventing system adopted by most of shipyard and enable the user to watch accident for 24 hours and notify it to user when it is incurring through state of the art ICT technology. And as a result of it the user can prevent the accident and man-made calamity at the beginning.

  • PDF