• 제목/요약/키워드: Suction time

검색결과 266건 처리시간 0.031초

Real-time prediction on the slurry concentration of cutter suction dredgers using an ensemble learning algorithm

  • Han, Shuai;Li, Mingchao;Li, Heng;Tian, Huijing;Qin, Liang;Li, Jinfeng
    • 국제학술발표논문집
    • /
    • The 8th International Conference on Construction Engineering and Project Management
    • /
    • pp.463-481
    • /
    • 2020
  • Cutter suction dredgers (CSDs) are widely used in various dredging constructions such as channel excavation, wharf construction, and reef construction. During a CSD construction, the main operation is to control the swing speed of cutter to keep the slurry concentration in a proper range. However, the slurry concentration cannot be monitored in real-time, i.e., there is a "time-lag effect" in the log of slurry concentration, making it difficult for operators to make the optimal decision on controlling. Concerning this issue, a solution scheme that using real-time monitored indicators to predict current slurry concentration is proposed in this research. The characteristics of the CSD monitoring data are first studied, and a set of preprocessing methods are presented. Then we put forward the concept of "index class" to select the important indices. Finally, an ensemble learning algorithm is set up to fit the relationship between the slurry concentration and the indices of the index classes. In the experiment, log data over seven days of a practical dredging construction is collected. For comparison, the Deep Neural Network (DNN), Long Short Time Memory (LSTM), Support Vector Machine (SVM), Random Forest (RF), Gradient Boosting Decision Tree (GBDT), and the Bayesian Ridge algorithm are tried. The results show that our method has the best performance with an R2 of 0.886 and a mean square error (MSE) of 5.538. This research provides an effective way for real-time predicting the slurry concentration of CSDs and can help to improve the stationarity and production efficiency of dredging construction.

  • PDF

재팽창 폐부종 치험 2례 보고 (Re-expansion Pulmonary Edema -2 Cases Report-)

  • 강경민
    • Journal of Chest Surgery
    • /
    • 제28권1호
    • /
    • pp.81-84
    • /
    • 1995
  • Re-expansion pulmonary edema following pneumothorax or hemothorax is clinically uncommon but occasionally life threatening. Clinical details are given of two patients.Ipsilateral pulmonary edema were developed after chest tube insertion due to spontaneous pneumothorax in case I and after evacuation of postoperative hemothorax in case II. The patients were treated with frequent bronchial toilet.The administration of colloid solution and diuretics was effective. The possible mechanisms underlying the edema are discussed.Both increased time of collapse and suction tended to correlate with reexpansion edema.The present two cases provided evidence for longstanding lung collapse and immediate application of suction.

  • PDF

압축기용 흡입머플러의 성능개선에 관한 연구 (A Study on Improvement of Efficiency of Suction Muffler for Compressor)

  • 정경훈;이은영;김우영;이유엽;황원걸
    • 한국정밀공학회지
    • /
    • 제19권2호
    • /
    • pp.220-227
    • /
    • 2002
  • The design of suction muffler for compressor aims to achieve a maximum noise reduction and a minimum pressure loss. Until now, the design process has been performed experimentally rather than theoretically. In this paper, to achieve the maximum noise reduction and minimum pressure loss. we studied the effect of the shape and volume of the expansion tube of the muffler on TL and pressure drop. We made an extensive use of computer program such as SYSNOISE. FLUENT, and STAR-CD to calculate the TL and pressure distribution of suction muffler. The design of the muffler is optimized with respect to flow loss and TL. Experiments are performed to check the result of design change, which proves satisfactory results. It is expected that this process can reduce time to design a muffler in the fields.

강하게 가열된 벽면 위에서 충격파에 의한 경계층 박리의 제거에 관한 수치 연구 (Numerical Study on the Suppression of Shock Induced Separation on a Strongly Heated Wall)

  • 이덕봉;신준철
    • 한국전산유체공학회지
    • /
    • 제2권2호
    • /
    • pp.59-72
    • /
    • 1997
  • A numerical model is constructed to simulate the interactions of oblique shock wave / turbulent boundary layer on a strongly heated wall. The heated wall temperature is two times higher than the adiabatic wall temperature and the shock wave is strong enough to induce boundary layer separation. The numerical diffusion in the finite volume method is reduced by the use of a higher order convection scheme(UMIST scheme) which is a TVD version of QUICK scheme. The turbulence model is Chen-Kim two time scale model. The comparison of the wall pressure distribution with the experimental data ensures the validity of this numerical model. The effect of strong wall heating enlarges the separation region upstream and downstream. In order to eliminate the separation, wall suction is applied at the shock foot position. The bleeding slot width is about same as the upstream boundary layer thickness and suction mass flow is 10% of the flow rate in the upstream boundary layer. The final configuration of the shock reflection pattern and the wall pressure distribution approach to the non-viscous value when wall suction is applied.

  • PDF

신형 수이젝터 개발을 위한 실험연구 (Experimental Study for the Development of New Type Water Ejector)

  • 문수범;최현규;최재혁;권형정;김경근;최순호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권6호
    • /
    • pp.677-684
    • /
    • 2006
  • An ejector is a fluid transfer device to be used for mixing of fluids, maintaining vacuum, and overcoming a poor suction condition. To date, most ejectors have been made from the casting process. which is time-consuming and high-cost process. Therefore, a new production method of ejectors is desired if any. In this experimental study, we proposed a new type ejector manufactured from the commercial fitting materials and the welding process, which is equipped with an orifice type nozzle. The proposed ejector has a good integrity compared with the conventional ejector because the fittings have manufactured by forging and they have more strength than the casting materials. Furthermore we adopted a multi-opening orifice type nozzle for improving a suction capacity and compared with a single-opening orifice type nozzle. From the experimental results. we confirmed that the multi-opening nozzle had a food suction capacity than the single-opening nozzle and the proposed new type ejector showed higher vacuum than the conventional type ejector in non-load condition. These improved characteristics suggests that a new type ejector by using the commercial fittings opens the feasibility to be adopted in various industry fields and that the increased suction capacity can be achieved by altering the nozzle design of a conventional ejector.

Diagnostics of nuclear reactor coolant pump in transition process on performance and vortex dynamics under station blackout accident

  • Ye, Daoxing;Lai, Xide;Luo, Yimin;Liu, Anlin
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2183-2195
    • /
    • 2020
  • A mathematical model for the flowrate and rotation speed of RCP during idling was established. The numerical calculation method and dimensionless method were used to analyze the flow, head, torque and pressure and speed changes under idle conditions. Regularity, using the Q criterion vortex identification judgment method combined with surface flow spectrum morphology analysis to diagnose the vortex dynamic characteristics on RCP blade. On impeller blade, there is two oscillations in the pressure ratio on pressure surface in blade outlet region. The velocity on the suction surface is two times more oscillating than the inlet of blade, and there is an intersection with the velocity ratio curve on pressure surface. On blade of guide vane, the pressure ratio increases along the inlet to outlet direction, and the speed ratio decreases with the increase of idle time. There is a vortex that rotates counterclockwise on the suction surface, and the streamline on the suction surface of blade is subjected to the entrainment and blocking action of the vortex creates a large reverse flow in the main flow region. There are two vortices at the outlet of guide vane suction side and the vortices are in opposite directions.

왕복동 압축기의 성능에 대하여 (THE CHARACTERISTIC OF A TWO STAGE AMMONIA RECIPROCATING COMPRESSOR)

  • 조권옥;오후규
    • 한국수산과학회지
    • /
    • 제10권1호
    • /
    • pp.65-69
    • /
    • 1977
  • The characteristics of two stage compressor which is constituted of two separated reciprocating compressors was tested measuring the volumetric efficiency of each compressor at suction of both bighandlowpressdresideusillgorificetypeflolrmeters. The volumetric efficiency of low pressure side compressor was lower than that of the high side when they were operating under the same compression ratio. And it tended to reduce obviously by lowering evaporating temperature resulting in a markable reduction of refrigerating capacity at the same time. It is assumed that the falling of volumetric efficiency at low side compressor was directed by the decrease in evaporating temperature which derives the falls of gas pressure at suction, increase in compression ratio, and gas flow resistance at suction and discharge valves.

  • PDF

A model of roof-top surface pressures produced by conical vortices : Model development

  • Banks, D.;Meroney, R.N.
    • Wind and Structures
    • /
    • 제4권3호
    • /
    • pp.227-246
    • /
    • 2001
  • The objective of this study is to understand the flow above the front edge of low-rise building roofs. The greatest suction on the building is known to occur at this location as a result of the formation of conical vortices in the separated flow zone. It is expected that the relationship between this suction and upstream flow conditions can be better understood through the analysis of the vortex flow mechanism. Experimental measurements were used, along with predictions from numerical simulations of delta wing vortex flows, to develop a model of the pressure field within and beneath the conical vortex. The model accounts for the change in vortex suction with wind angle, and includes a parameter indicating the strength of the vortex. The model can be applied to both mean and time dependent surface pressures, and is validated in a companion paper.

토양의 염기치환 용량 측정에 관한 연구 (측정장치에 대하여) (Determination of Cation Exchange Capacity in Soils (study on the apparatus))

  • 최대웅;이종목
    • 한국토양비료학회지
    • /
    • 제6권2호
    • /
    • pp.83-88
    • /
    • 1973
  • 염기치환용량 측정을 위하여 염기의 포화 과잉염기의 세척을 위한 작업단계에서 현재 사용되어 오던 원심분리기, 흡인여과장치 보다 새로이 고안된 Column set를 이용 하였을때 다음과 같은 양호한 결과를 얻었다. 1. CEC 측정치는 흡인여과시의 치와 99.91%인 고도의 상관이 있었으며 반복성의 변이가 흡인여과 1.94%에 비해 1/3이나 적은 0.66%로 정확도도 더욱 높았다. 2. Column set 이용시 흡인여과에 비하여 작업시간 및 노력이 1/3정도 절약되고 한거번에 다량의 시료를 처리할 수 있다. 3. 고가의 기계(Vacuum pump, Shaker, Section, Apparatus, Centrifuge) 등이 구비되지 않아도 CEC를 측정할 수 있었다.

  • PDF

기관내 흡인 실시 후의 동맥혈 산소 분압 변화와 심부정맥 발현에 관한 연구 (Changes in Arterial Oxygen Tension($PaO_2$) and Cardiac Arrhvthmias after Endotracheal Suction)

  • 김선화;신정숙;최영희
    • 대한간호
    • /
    • 제33권4호
    • /
    • pp.62-85
    • /
    • 1994
  • The data were analyzed by using an S. P. S. S. computerized program for mean, standard deviation, percentage and paired t-test. The results of this study were as follows: 1. The increase in $PaO_2$ after hyperoxygenation and hyperinflation was highly statistically significant(p=0.041), and the increase in $PaO_2$ immediately after suctioning was not significant (p=0.752). The time of lowest $PaO_2$ was 30 seconds after the endotracheal suction. 2. The occurrance of cardiac arrhythmia after the endotracheal suction included sinus tachycardia, sinus arrhythmia, sinus bradycardia, premature atrial contraction (PAC), and premature ventricular contraction (PVC). The most frequent cardiac arrhythmia was sinus tachycardia (a subjects). Sinus arrhythmia was observed in 5 subjects and continued till 10 minutes after suctioning in two of these. Sinus bradycardia occurred in only 3 subjects and among them, 1 subjects shows sinus arrythmia till 10 minutes after suctioning along. PAC was observed in only one subject and continued till five minutes after suctining along with sinus arrhythmia. PVC was observed in three subjects: it lasted for only 30 seconds after suctioning in two subjects. but continued for 10 minutes after suctioning in the third. 6 subjects manifested two kinds of Cardiac arrhythmia Three of them showed sinus tachycardia with PVC, another 2 showed sinus bradycardia with sinus arrhythmia, and the other subject showed sinus arrhythmia with PAC. 3. The increases in heart rate during the endotracheal suction immediately after and at 30 seconds after suctioning were statistically significant (p=0.005). The increase in heart rate at one minute after suctioning was also significant (p=0.023). The increase in heart rate continued until 10 minutes after the endotracheal suction, but was not statistically significant In this study, endotracheal suctioning with hyperoxygenation and hyperinflation was effective in preventing a decrease in $PaO_2$ after suctioning, but not in preventing cardiac arrhythmias. Nurses should be aware of the complications of endotracheal suctioning and do effective hyperoxygenation and hyperinflation before and after suctioning. Further research is needed to develop a efficient endotracheal suction method which will minimize complications. This study needs to be replicated with different population of patients intubatted or having a tracheostomy, specifically, patients who cardiac or pulmonary desease. The data were analyzed by using an S. P. S. S. computerized program for mean, standard deviation, percentage and paired t-test. The results of this study were as follows: 1. The increase in $PaO_2$ after hyperoxygenation and hyperinflation was highly statistically significant(p=0.041), and the increase in $PaO_2$ immediately after suctioning was not significant (p=0.752). The time of lowest $PaO_2$ was 30 seconds after the endotracheal suction. 2. The occurrance of cardiac arrhythmia after the endotracheal suction included sinus tachycardia, sinus arrhythmia, sinus bradycardia, premature atrial contraction (PAC), and premature ventricular contraction (PVC). The most frequent cardiac arrhythmia was sinus tachycardia (a subjects). Sinus arrhythmia was observed in 5 subjects and continued till 10 minutes after suctioning in two of these. Sinus bradycardia occurred in only 3 subjects and among them, 1 subjects shows sinus arrythmia till 10 minutes after suctioning along. PAC was observed in only one subject and continued till five minutes after suctining along with sinus arrhythmia. PVC was observed in three subjects: it lasted for only 30 seconds after suctioning in two subjects. but continued for 10 minutes after suctioning in the third. 6 subjects manifested two kinds of Cardiac arrhythmia Three of them showed sinus tachycardia with PVC, another 2 showed sinus bradycardia with sinus arrhythmia, and the other subject showed sinus arrhythmia with PAC. 3. The increases in heart rate during the endotracheal suction immediately after and at 30 seconds after suctioning were statistically significant (p=0.005). The increase in heart rate at one minute after suctioning was also significant (p=0.023). The increase in heart rate continued until 10 minutes after the endotracheal suction, but was not statistically significant In this study, endotracheal suctioning with hyperoxygenation and hyperinflation was effective in preventing a decrease in $PaO_2$ after suctioning, but not in preventing cardiac arrhythmias. Nurses should be aware of the complications of endotracheal suctioning and do effective hyperoxygenation and hyperinflation before and after suctioning. Further research is needed to develop a efficient endotracheal suction method which will minimize complications. This study needs to be replicated with different population of patients intubatted or having a tracheostomy, specifically, patients who cardiac or pulmonary desease.

  • PDF