• 제목/요약/키워드: Suction Air Flow

검색결과 156건 처리시간 0.027초

An Experimental Study of the Trust Vector Control Using Counterflow Concept

  • C. M. Lim;Kim, H. D.;Lee, K. H.;T. Setoguchi
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.192-197
    • /
    • 2004
  • Recently, fluidic thrust vectoring methods have been preferably employed to control the movement of propulsive systems due to relatively simpler design and lower cost than mechanical thrust vectoring methods. For An application of the thrust vectoring to flight bodies, it is necessary to understand very complicated exhaust flows which are often subject to shock waves and boundary layer separation. But researches for the thrust vector control using counterflow have been few. In the present study, experiments have been performed to investigate the characteristics of supersonic jets controlled by a thrust vectoring method using counterflow. The primary jet is expanded through a two-dimensional primary nozzle shrouded by collars, and is deflected by the suction of the air near nozzle into an upper slot placed between the primary nozzle and the upper collar. A shadowgraph method is used to visualize the supersonic jet flowfields. Primary nozzle pressure ratios and suction nozzle pressure ratios are varied from 3.0 to 5.0, and from 0.2 to 1.0 respectively. The present experimental results showed that, for a given primary nozzle pressure ratio, a decrease in the suction nozzle pressure ratio produced an increased thrust vector angle. As the suction nozzle pressure ratios were increased and decreased, the hysteresis of the thrust vectoring was observed through the wall pressure distributions

  • PDF

연료전지 블로어 4기종 국산화 개발 (Development of 4 Types of Fuel Cell's Blower)

  • 탁봉열;김찬규;이소아;장춘만
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.91-91
    • /
    • 2011
  • This paper describes development procedure of the four types of fuel cell's blowers: pressurized fuel blower, selective oxidation air blower, cathode air blower, and burner air blower. Diaphragm blowers having two heads are selected to maintain force balance when the rotating arms are moving by the driving motor. Dimensions of a diaphragm cavity is designed according to the optimal design procedure using numerical simulation and experimental measurement. Experimental apparatus is designed by considering the bower characteristics having low flow rate and high pressure. Test blower is operated by a diaphragm, which has suction and discharge port on the top of the blower. For analyzing the internal flow of the blower, three-dimensional Navier-Stokes analysis is introduced in the present study. Throughout the optimal design of the blowers, blower performance is enhanced by reducing the unbalance motion of the rotating arm and loss region in the diaphragm cavity.

  • PDF

송풍기 설부 주변 유동의 개선에 관한 연구 (Study on improvements for flows near cut-off region in blower)

  • 김재원;박진원
    • 한국전산유체공학회지
    • /
    • 제8권1호
    • /
    • pp.1-7
    • /
    • 2003
  • The present study has conducted the analysis of flows in a blower with double suction. The air handling system is for supplying air flows into a plant. The present system has a couple of impellers in axial direction for enhanced flow rate. Main interest lies on the improvements of static pressure rise and total efficiency of the system. The present treatment of the reform is to secure a spatial distance between the fan and the casing of the system and change the shape of the cut-off part. The resultant performance after the reform shows increased pressure-rise and efficiency of the system

펌프 흡수정내 발생된 보텍스에 대한 CFD 예측 (CFD Prediction on Vortex in Sump Intake at Pump Station)

  • 박상언;노형운
    • 한국유체기계학회 논문집
    • /
    • 제10권4호
    • /
    • pp.39-46
    • /
    • 2007
  • In large pump station, vortex generation such as free-surface vortex and submerged vortex occurring around pump intake, or at bell-mouth inlet has been an important flow characteristics which should be considered always to keep away the suction of air-entrained or cavitated flow. In this study, a commercial CFD code was used to predict accurately the vortex generation for the specified intake design. These result shows the preliminary result of submerged vortex prediction for the Turbo-machinery Society of Japan Sump Test CFD standard model. At bottom wall, air volume fraction (red color) was found in a large scale to explain the submerged vortex generation at particular operation and configuration condition. And these indicate the free surface formation behind the bell mouth. Particularly, non-uniform approaching flow is a major parameter to govern the occurrence of the free-surface vortex. Futhermore the comparison between turbulence ($k-{\epsilon}$ & $k-{\omega}$ model) mode were executed in this study.

퍼지로직 과열도 재설정 알고리즘을 사용한 멀티형 냉방시스템의 전자팽창밸브 제어 (The EEV Control of the Multi-type Air-conditioning System by using a Fuzzy Logic Superheat Temperature Setpoint Reset Algorithm)

  • 한도영;이상원
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.382-388
    • /
    • 2003
  • Refrigerant flow rates of the multi-type air-conditioning system can be regulated by electronic expansion valves (EEV). The performance of the multi-type air-conditioning system may be improved by lowering the superheat at the compressor suction side. In this study, a superheat temperature setpoint reset algorithm was developed by using fuzzy logics, and a PI algorithm was applied to control the superheat temperature near setpoints. Experimental results showed energy savings and stable operations at a multi-type air-conditioning system. Therefore, the developed setpoint reset algorithm may be effectively used for the EEV superheat temperature control of the multi-type air-conditioning system.

바닥의 위치가 Vortex Vent의 배기성능에 미치는 영향 (Effect of the Floor on the Ventilation Performance of the Vortex Vent)

  • 이진원;임영복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.154-158
    • /
    • 2009
  • The vortex ventilation system (VV) which uses a rotating finned swirler installed coaxially with the exhaust duct is a very effective local ventilator. VV can enhance the capture depth by a factor of 3-5 compared to the conventional exhaust hood, in the absence of any solid walls nearby. In real situations there may exist ceiling, side wall and floor, all of which can affect the flow field and suction performance by way of the no-slip condition on the walls. 3D CFD simulation was performed in order to see the effect of the floor on the capture performance of the VV. The presence of floor reduced suction flow velocity, and increased the critical rotational speed which is the rotational speed required for stable vortex formation. Flow velocity profile along the axis could be well approximated by a universal functional form when the distance from the exhaust inlet is non-dimensionalized by the distance to the floor. Capture depth, define by the distance from the exhaust inlet to a point of velocity decreased to 10% of that at the inlet, is reduced by about 10% when the floor distance is 6 times the exhaust hood diameter.

  • PDF

수직 오리피스 이젝터의 혼합유동 및 산소전달 특성 (Mixed Flow and Oxygen Transfer Characteristics of Vertical Orifice Ejector)

  • 김동준;박상규;양희천
    • 대한기계학회논문집B
    • /
    • 제39권1호
    • /
    • pp.61-69
    • /
    • 2015
  • 본 논문은 수직 오리피스 이젝터의 혼합유동 및 산소전달 특성에 대한 실험적 연구를 목적으로 한다. 실험장치는 전동 모터-펌프, 오리피스 이젝터, 순환 수조, 공기압축기, 고속 카메라 시스템 그리고 제어 및 측정기기로 구성하였다. 측정된 구동유체 및 유입공기의 유량을 이용하여 유량비를 도출하였다. 이적터에서 분출된 혼합유동의 가시화를 통해 정성적 거동을 고찰하였으며, 용존산소 농도를 측정하여 총괄 산소전달계수를 도출하였다. 구동유체의 유량이 일정하고 압축기의 공기압이 높아지면 유량비와 산소전달계수는 증가하며, 압축기의 공기압이 일정하고 구동유체의 유량이 증가하면 유량비는 감소하지만 산소전달계수는 증가하였다. 기포의 크기에 따른 체류시간 및 확산도와 수직 혼합유동의 도달거리는 2 상의 접촉면적과 시간에 크게 영향을 미치기 때문에 산소전달율의 중요한 변수임을 유추할 수 있다.

라디에이터 통과풍량 확보를 위한 수치적 검토 (Numerical Analysis for Improving Passing Flow Rate Quantity abound a Radiator)

  • 김은필;강상훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.304-310
    • /
    • 2001
  • This paper describes the analysis of flow field using a projection finite element method. The projection scheme with a pressure correction is presented for the analysis of an incompressible Navier-Stokes flow. The projection scheme is analyzed numerically and applied to the well-known bench marking problems such as lid driven cavity. Finally, the projection scheme is applied to a flow through the automobiles front. In the automobiles cooling system, the flow through its front is very important to a cooling performance. The results show that the flow quantity increases by locating the position of bumper to the further front position of a car. And, the improvement on the suction part below a bumper achieves the more passing flow quantity. The attachment of an air dam increases passing flow quantity causing the pressure rise to the front part and the pressure drop beneath a car.

  • PDF

3-D Dynamic Visualization by Stereoscopic PIV

  • LEE Young-Ho
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.15-23
    • /
    • 2004
  • The present study is aimed to achieve dynamic visualization from the in-house 3-D stereoscopic PIV to represent quantitative flow information such as time-resolved 3-D velocity distribution, vorticity, turbulent intensity or Reynolds stresses and so on. One of the application of the present study is Leading edge extension(LEX) flow appearing on modern delta wing aircraft. The other is mixing flow in stirring tank used in industry field. LEX in a highly swept shape applied to a delta wing features the modern air-fighters. The LEX vortices generated upon the upper surface of the wing at high angle of attack enhance the lift force of the delta wing by way of increased negative suction pressure over the surfaces. The present method resolves also the complicated flow patterns of two type impellers rotating in stirring vessel. Flow quantities such as three velocity vector components, vorticity and other flow information can be easily visualized via the 3D time-resolved post-processing visualization. And it makes the easy understanding of the unsteady flow characteristics of the typical industrial mixers.

  • PDF

에어엔드 형상변화에 따른 스크류 압축기 성능에 관한 실험적 연구 (Experimental Study on the Performance of Screw Compressor with Various Shapes of Air End)

  • 김태윤;이재영;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제16권1호
    • /
    • pp.5-10
    • /
    • 2013
  • The performance of screw air compressor is affected by rotor profile, lobe number, air end wrap angle, rotor L/D ratio, suction and discharge ports, revolutions of air end and load regulation control, etc. In general, an efficient screw compressor needs a rotor profile of which has a large flow cross-section area, short sealing lines and a small blow-hole. In this study, experimental study was performed with newly designed $5{\times}6$ rotor profile and various shapes of air end. Results show that the measured specific power consumption of the newly designed screw compressor appeared to be lower than any other published data for the equivalent screw compressors manufactured.