• Title/Summary/Keyword: Subway particle

Search Result 65, Processing Time 0.022 seconds

Implementation of Indoor Air Quality Monitoring System for Subway Stations (지하철 역사 공기질 모니터링 시스템의 구현)

  • Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.294-301
    • /
    • 2013
  • The particle matter concentrations in the subway stations should be monitored and controlled for the health of commuters on the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. In this paper, the reliability of the cheap instruments using light scattering method is improved with the help of a linear regression analysis technique to measure the $PM_{10}$ concentrations continuously in the subway stations. In addition, a monitoring system is implemented to display and record the data of $PM_{10}$, $CO_2$, humidity, and temperature. To transmit and receive these measured sensor data, CDMA M2M wireless communication method is applied.

Characteristics of PM10 Measured by Different Light-Scattering Instruments in Public Transport Vehicles (광산란 측정장치에 따른 대중교통차량 미세먼지 측정 특성)

  • Kwon, Soon-Bark;Jeong, Wootae;Park, Duckshin
    • Particle and aerosol research
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • In this study, indoor $PM_{10}$ concentration was measured by different type of real-time instruments in public transport vehicles. Light-scattering method is widely used in measuring the size of particulate matters and there is two types of light-scattering methods; one is the nephelometer type which measures the light-scattering degree by aerosol cloud, the other is the spectrometer type which measures light-scattering degree by individual particle. We observed the variation of $PM_{10}$ in KTX, subway and express bus carriages by 1-minute resolution and found that there is similar tendency in pattern among 4 light-scattering devices but difference in absolute concentrations. By comparing gravimetric result in a subway cabin, the spectrometer type device, C, was chosen as a reference device. The conversion factors of nephelometer device A-1, A-2, and B were 1.666, 1.463 and 2.125 respectively.

Single-particle Characterization of Aerosol Samples Collected at an Underground Shopping Area (단일입자분석법을 이용한 지하상가에서 채취한 실내입자의 특성분석)

  • Kang, Sun-Ei;Hwang, Hee-Jin;Park, Yu-Myung;Kang, Su-Jin;Kim, Hye-Kyung;Ro, Chul-Un
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.594-603
    • /
    • 2008
  • A single particle analytical technique, named low-Z particle electron probe X-ray microanalysis, was applied to characterize four samples collected at an underground shopping area connected to Dongdeamun subway station, in January and May 2006. Based on the analysis of their chemical compositions of the samples, many distinctive particle types are identified and the major chemical species are observed to be soil-derived particles, iron-containing particles. sulfates. nitrates, and carbonaceous particles. which are encountered both in coarse and fine fractions. Carbonaceous particles exist in carbon-rich and organic. Soil derived particles such as aluminosilicates, AlSi/C, $CaCO_3\;and\;SiO_2$ are more frequently encountered in spring samples than winter samples. Nitrate- and sulfate-con taming particles are more frequently encountered in winter samples, and those nitrate- and sulfate-containing particles mostly exist in the chemical forms of $Ca(CO_3,\;NO_3),\;Ca(NO_3,\;SO_4),\;(Na,\;Mg)NO_3\;and\;(Mg,\;Na)(NO_3,\;SO_4)$. Fe-containing particles which came from nearby subway platform are in the range of about 10% relative abundances for all the samples. It is observed that nitrate- and sulfate-containing particles and carbonaceous particles are much more frequently encountered in indoor aerosol samples than in outdoor aerosols, implying that $NO_x,\;SO_x$, and VOCs at the underground shopping area were more partitioned into aerosol phase.

CFD Analysis of Axial Flow Cyclone Separator for Subway Station HVAC System (지하역사 공기조화기에 적용 가능한 미세먼지 제거용 사이클론의 수치해석적 연구)

  • Kim, Jin-Kwan;Kim, Ho-Joong;Lee, Myung-Jun;Kim, Tae-Sung;Kwon, Soon-Bark
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.546-550
    • /
    • 2008
  • In this study, 3-dimensional Computational Fluid Dynamics (CFD) analysis was induced to simulate air flow and particle motion in the axial flow cyclone separator. The commercialized CFD code FLUENT was used to visualize pressure drop and particle collection efficiency inside the cyclone. We simulated 4 cyclone models with different shape of vane, such as turning angle or shape of cross section. For the air flow simulation, we calculated the flow field using standard ${\kappa}-{\varepsilon}$ turbulence viscous model. Each model was simulated with different inlet or outlet boundary conditions. Our major concern for the flow filed simulation was pressure drop across the cyclone. For the particle trajectory simulation, we adopted Euler-Lagrangian approach to track particle motion from inlet to outlet of the cyclone. Particle collection efficiencies of various conditions are calculated by number based collection efficiency. The result showed that the rotation angle of the vane plays major roll to the pressure drop. But the smaller rotation angle of vane causes particle collection efficiency difference with different inlet position.

  • PDF

Characteristics of PM10 and PM2.5 Concentrations at Subway Stations in Busan for 3 years (2015~2017) (부산지역 지하역사의 최근 3년간(2015~2017년) PM10과 PM2.5 농도 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.28 no.7
    • /
    • pp.581-594
    • /
    • 2019
  • This research investigated the characteristics of $PM_{10}$ and $PM_{2.5}$ concentrations at the main subway stations in Busan. Annual mean $PM_{10}$ concentrations at the Seomyeon 1- waiting room and platform were $51.3{\mu}g/m^3$ and $47.5{\mu}g/m^3$, respectively, and the annual $PM_{2.5}$ concentration at the Seomyeon 1- platform was $28.8{\mu}g/m^3$. $PM_{2.5}$/$PM_{10}$ ratio at Seomyeon 1-platform and Dongnae station were 0.58 and 0.53, respectively. Diurnal variation of $PM_{10}$ concentration at subway stations in Busan was categorized into four types, depending on the number of peaks and the times at which the peaks occurred. Unlike the areas outside of the subway stations which reported maximum $PM_{10}$ concentration mostly in spring across the entire locations, the interiors of the subway stations reported the maximum $PM_{10}$ concentration in spring, winter, and even summer, depending on their location. $PM_{10}$ concentration was highest on Saturday and lowest on Sunday. The numbers of days when $PM_{10}$ concentration exceeded $100{\mu}g/m^3$ and $80{\mu}g/m^3$ per day over the last three years at the subway stations in Busan were 36 and 239, respectively. The findings of this research are expected to enhace the understanding of the fine particle characteristics at subway stations in Busan and be useful for developing a strategy for controlling urban indoor air quality.

The Correlation between Radon (Rn222) and Particulate Matters (PM10, PM2.5, PM1.0) in Subway Tunnel in Seoul.

  • Versoza, Michael;Park, Duckshin
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.87-95
    • /
    • 2017
  • Radon ($Rn^{222}$) is a radioactive gas and is found at high concentrations underground. Investigations were done in many years specifically on public transportations such as in the subway stations, concourses and platforms for these are located underground areas. This study correlates the $Rn^{222}$ concentrations with the Particulate Matter (PM) concentration for the gas could be attached or trapped inside these particles. It was done on the opening subway tunnel of Miasageori Station going to Mia Station (Line 4) last August 2016. Based on the result, the $Rn^{222}$ were more influenced on the mass ratio (%) of PM present in the air instead of its mass concentration (${\mu}g/m^3$). As the $PM_{10}$ mass ratio increases ($42.32{\pm}1.03%$) during morning rush-hours, radon starts to increase up to $0.97{\pm}0.03pCi/L$. But during the afternoon $Rn^{222}$ concentrations decreased while the composition were stable at $22.96{\pm}3.0%$, $39.04{\pm}0.6%$ and $38.01{\pm}0.3%$ in $PM_1$, $PM_{2.5}$ and $PM_{10}$ respectively. It was then assumed that it could be the composition of the morning hours of the station were influencing the concentration of the radon.

Development of an ionic wind dust collector towards coronavirus reduction in subway stations (지하철 역사 내 코로나 바이러스 저감을 위한 이온풍 집진기 개발)

  • Shin, Dongho;Kim, Younghun;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Since 2019, the corona virus has been continuously affect human life. In particular, in the indoor space where people live, infection by airborne transmission of viruses is a problem. Among them, the spread in the subway, which is the main mode of transport for humans, can be serious. To solve this problem, our research team developed an ionic wind collector to collect and remove corona virus using an ionic wind collector and ozone. In order to apply the ionic wind collector to the subway, it must operate in two modes. Because large amounts of ozone are harmful to the human body. There is a mode that collects bio-aerosol from the air using ionic wind and a mode that inactivates viruses floating in the air by generating a large amount of ozone. As the applied voltage increased, the cleaning ability of the ionic wind collector increased, and the farther the distance between the discharge electrode and the ground plate, the higher the cleaning ability even at low current. In addition, clean air delivery rate (CADR) of an ionic wind collector was up to 5.5 m3/min. As a result of measuring the amount of ozone generated, it was confirmed that 50 ppb to 250 ppb was generated, and it was confirmed that ozone generation was controllable in the ionic wind dust collector.

Development of Air Cleaning Roll-Filter for Improving IAQ in Subway (도시철도 객실 공기질 개선을 위한 롤필터 개발연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;NanGoong, Seok;Han, Tae-Woo;Cho, Kwan-Hyun;Kim, Tae-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.313-319
    • /
    • 2011
  • In a modern society, various type of transportation modes are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day in Seoul. Due to the increased interests on the indoor air quality (IAQ) of underground facilities, public concerns on IAQ of subway system are increasing also. Platform screen door (PSD) recently installed at the whole stations of Seoul subway and tunnel washing-out appeared to be effective in reducing particulate matters in the platform and tunnel. However there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin due to the problem of maintenance cost. Therefore, the object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. In this paper, we focused on the development of particle removing system utilizing a roll-filter for increasing operating time of air filter. The prototype of system was designed and manufactured based on the numerical prediction results. For rollfilter device, 5 candidate filter materials were tested in point of particle collection efficiency and pressure drop. It was found that the electrically charged filter material showed the highest performance among them.

Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map (서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발)

  • Lee, Eun-Sun;Park, Min-Bin;Lee, Tae-Jung;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

A Comparative Analysis of Dust Particles Collected by Cleaning Equipments in Subway Tunnel (도시철도 터널 내 청소장치별 집진먼지 비교 분석)

  • Lee, Young-Kwon;Kim, Il-Hong;Jo, Byung-Ki;Kim, Man-Hwa;Park, Jong-Heon
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1388-1398
    • /
    • 2011
  • Air pollution in subway tunnel is primarily caused from the wear of metallic materials. As undesirable substance, PM(Particulate Matter) can especially harm the health of passengers and workers as well as clog the main parts of rolling stock such as inverters. To improve the air quality in subway tunnel, SMRT(Seoul Metropolitan Rapid Transit Corporation) has developed anti-pollution devices such as Magnetic Dust Collector, Vacuum Cleaner For Rail Road and Particulate Removing Sprinkler Vehicle. Introducing these mechanical devices, this paper is mainly devoted to explaining the characteristics of collected dust according to the result of particle-size analysis and componential analysis.

  • PDF