• Title/Summary/Keyword: Subway Stations

Search Result 391, Processing Time 0.023 seconds

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) in Public Facilities, Korea

  • Kim, Ho-Hyun;Lim, Young-Wook;Jeon, Jun-Min;Kim, Tae-Hun;Lee, Geon-Woo;Lee, Woo-Seok;Lim, Jung-Yun;Shin, Dong-Chun;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.72-84
    • /
    • 2013
  • In the study, pollution levels of indoor polycyclic aromatic hydrocarbons (PAHs) in public facilities (vapor phase or particulate phase) were evaluated, and a health risk assessment (HRA) was carried out based on exposure scenarios. Public facilities in Korea covered by the law, including underground subway stations, funeral halls, child care facilities, internet cafes (PC-rooms), and exhibition facilities (6 locations for each type of facility, for a total of 48 locations), were investigated for indoor assessment. For the HRA, individual excess cancer risk (ECR) was estimated by applying main toxic equivalency factor (TEF) values suggested in previous studies. Among the eight public facilities, internet cafes showed the highest average $PM_{2.5}$ concentration at $110.0{\mu}g/m^3$ (range: $83.5-138.5{\mu}g/m^3$). When assuming a risk of facility exposure time based upon the results of the surveys for each public facility, the excess cancer risk using the benzo(a)pyrene indicator assessment method was estimated to be $10^{-7}-10^{-6}$ levels for each facility. Based on the risk associated with various TEF values, the excess cancer risk based upon the seven types cancer EPA (1993) and Malcolm & Dobson's (1994) assessment method was estimated to be $10^{-7}-10^{-5}$ for each facility. The excess cancer risk estimated from the TEF EPA (2010) assessment was the highest: $10^{-7}-10^{-4}$ for each facility. This is due to the 10-fold difference between the TEF of dibenzo(a,e)fluoranthene in 2010 and in 1994. The internet cafes where smoking was the clear pollutant showed the highest risk level of $10^{-4}$, which exceeded the World Health Organization's recommended risk of $1{\times}10^{-6}$. All facilities, with the exception of internet cafes, showed a $10^{-6}$ risk level. However, when the TEFs values of the US EPA (2010) were applied, the risk of most facilities in this study exceeded $1{\times}10^{-6}$.

Analysis of Public Transport Ridership during a Heavy Snowfall in Seoul (기상상황에 따른 서울시 대중교통 이용 변화 분석: 폭설을 중심으로)

  • Won, Minsu;Cheon, Seunghoon;Shin, Seongil;Lee, Seonyeong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.859-867
    • /
    • 2019
  • Severe weather conditions, such as heavy snowfall, rain, heatwave, etc., may affect travel behaviors of people and finally change traffic patterns in transportation networks. To deal with those changes and prevent any negative impacts on the transportation system, understanding those impacts of severe weather conditions on the travel patterns is one of the critical issues in the transportation fields. Hence, this study has focused on the impacts of a weather condition on travel patterns of public transportations, especially when a heavy snowfall which is one of the most critical weather conditions. First, this study has figured out the most significant weather condition affecting changes of public transport ridership using weather information, card data for public transportation, mobile phone data; and then, developed a decision-tree model to determine complex inter-relations between various factors such as socio-economic indicators, transportation-related information, etc. As a result, the trip generation of public transportations in Seoul during a heavy snowfall is mostly related to average access times to subway stations by walk and the number of available parking lots and spaces. Meanwhile, the trip attraction is more related to business and employment densities in that destination.

Characteristics of Wind Speed and PM10 Concentration underneath Railway Trains (도시철도 차량 하부의 풍속 및 미세먼지 농도 특징)

  • Kim, Jong Bum;Woo, Sang Hee;Jang, Hong-Ryang;Chou, Jin-Won;Hwang, Moon Se;Park, Hyung-Koo;Yoon, Hwa Hyeon;Jung, Joon-Sig;Bae, Gwi-Nam
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.11-19
    • /
    • 2017
  • Since operation of railway trains is a major source of particle pollution in tunnel air, a particle removal device can be an effective measure to remove wear particles. To obtain design conditions of the particle removal device that will be installed underneath the railway trains, the wind speed and particle concentration underneath the trains were investigated using a three-dimensional ultrasonic anemometer and a DustTrak aerosol monitor, respectively. The measurements were made for the trains running on Seoul Metropolitan Subway Line 5 on February 10, 2015. The data were analyzed according to the track geometry (straight, curved) and train speed pattern (acceleration, cruising, and deceleration) between stations. Train speed was also analyzed. The average wind speed and $PM_{10}$ concentration underneath the trains were ~30% of the train speed and ${\sim}200{\mu}g/m^3$ for both straight and curved sections. Average $PM_{10}$ concentration for deceleration sections was higher than that for acceleration sections.

Human Exposures to Various Electromagnetic Forces : Measurement of Electromagnetic Force for Future Epidemiological Study (각종 전자파에 의한 인체의 노출 : 역학조사를 위한 전자파 측정)

  • Kim, Deok-Won;Ryu, Chang-Yong;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.191-200
    • /
    • 1995
  • Although air, water, and noise pollutions have been widely recognized, electromagnetic forces (EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, office machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven radiates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

  • PDF

A Study on the Effects of Demographic Characteristics of Consumers on Types of Preferred Menu: Focusing on Daegu and Gyongbuk Region (소비자의 인구통계학적 특성에 따른 선호메뉴 유형에 관한 연구: 대구.경북을 중심으로)

  • Lee, Won-Gab;Kim, Gi-Jin
    • Culinary science and hospitality research
    • /
    • v.20 no.1
    • /
    • pp.89-104
    • /
    • 2014
  • The purpose of this study was to investigate the effects of demographic characteristics such as gender, marital status, age, educational level, job and monthly income on the preferred menu classified by type of food, food material, cooking method, taste and food temperature. A survey was performed from the 5th to 10th of January, 2013 among consumers in such places as coffee shops and subway stations located in Daegu and Gyeongbuk region, and finally 307 data sets were used for analysis. The results of analysis showed that the strongest effects of demographic characteristics were observed in preferred menu classified by type of food(i.e. Korean, Western, Chinese, Japanese, buffet, herbal and instant foods), and the differences by marital status, age, educational level, job were statistically significant. In particular, the married consumers tended to prefer Korean and herbal foods, while the unmarried ones preferred western, Chinese, buffet and instant food. Moreover, the younger ones tended to prefer western, Chinese, buffet and instant foods, while the older ones preferred to eat Korean food. The younger unmarried ones liked beef and pork dishes, while the married ones over their forties tended to prefer vegetable dishes. The consumers less than or equal to their thirties tended to prefer roasted and fried foods compared to ones over their thirties.

Groundwater Recharge and Discharge in the Urban-rural Composite Area (도농복합지역 지하수 함양과 배출에 대한 연구)

  • Lee, Byung-Sun;Hong, Sung-Woo;Kang, Hee-Jun;Lee, Ji-Seong;Yun, Seong-Taek;Nam, Kyoung-Phile
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.2
    • /
    • pp.37-46
    • /
    • 2012
  • This study was conducted to identify groundwater recharge and discharge amounts of a representative urban-rural composite area located in Yongin city, Kyounggi-do, Korea. Groundwater recharge would be affected by mainly two processes in the study area: rainfall and leakage from public water pipelines including water-supply and sewage system. Groundwater recharge rate was estimated to be 13.5% by applying annual groundwater level data from two National Groundwater Monitoring Stations to the master regression curve method. Subsequently, the recharge amounts were determined to be $13,253{\times}10^3m^3/yr$. Leakage amounts from water-supply and sewage system were estimated to be $3,218{\times}10^3$ and $5,696{\times}10^3m^3/yr$, respectively. On the whole, a total of the recharge amounts was $22,167{\times}10^3m^3/yr$, of which 60% covers rainfall recharge and 40% pipeline leakage. Groundwater discharge occurred through three processes in the composite area: baseflow, well pumping, and discharge from urban infrastructure including groundwater infiltration into sewage pipeline and artificial extraction of groundwater to protect underground facilities from submergence. Discharge amounts by baseflow flowing to the Kiheung agricultural reservoir and well pumping were estimated to be $382{\times}10^3$ and $1,323{\times}10^3m^3/yr$, respectively. Occurrence of groundwater infiltration into sewage pipeline was rarely identified. Groundwater extraction amounts from the Bundang subway line as an underground facility were identified as $714{\times}10^3m^3/yr$. Overall, a total of the discharge amounts was determined to be $2,419{\times}10^3m^3/yr$, which was contributed by 29% of artificial discharge. Even though groundwater budget of the composite area was identified to be a surplus, it should be managed for a sound groundwater environment by changing deteriorated pipelines and controlling artificial discharge amounts.

Indoor Air Concentration of Particulate Matter and Endotoxin in Public Facilities (서울.경기 일부지역 다중이용시설실내공기 중 미세먼지와 미세먼지 중 내독소의 농도)

  • Jeon, Byung-Hak;Hwang, Yu-Kyung;Kim, Hyoung-Ah;Lee, Se-Hoon;Ahn, Kyu-Dong;Heo, Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.4
    • /
    • pp.262-270
    • /
    • 2008
  • This study was conducted to measure concentrations of particulate matter ($PM_{10}$, $PM_{2.5}$) and endotoxin in thirty public facilities (7 elderly-care facilities, 4 hypermarkets, 4 university hospitals, 7 child-care facilities, 4 subway stations and 4 bus terminals) from September 2004 to February 2007 in Seoul and Gyeonggi-do province. $PM_{10}$ or $PM_{2.5}$ was measured with glass fiber filter and mini volume air sampler for 6 to 8 hours in indoor and outdoor of the facilities and expressed as ${\mu}g/m^3$. After weighing the filter, endotoxin was analyzed by Limulus Ameobocyte Lysate method ($EU/m^3$). $PM_{10}$ in indoor air was higher (GM and GSD was 78.00 and $1.92\;{\mu}g/m^3$, respectively) than the outdoor air (GM and GSD was 60.70 and $2.23\;{\mu}g/m^3$, respectively, I/O=1.28). All measurements was not exceeded the national maintenance standard. Elderly-care and child-care facilities showed relatively higher concentrations ($83.27\;{\mu}g/m^3$ and $81.75\;{\mu}g/m^3$; I/O=2.01 and 1.19, respectively) than hypermarkets or university hospitals. The highest PM2.5 was seen in child-care facilities ($62.15\;{\mu}g/m^3$, I/O=2.42). The I/O of the endotoxin in the PM10 and the $PM_{2.5}$ was exceeded 1.0 (1.37 and 1.57, respectively). Indoor $PM_{10}$ was affected by user/day and humidity, and endotoxin in the PM10 was affected by temperature. In conclusion, elderly- and child-care facilities are high priority facilities to be improved indoor air quality.

Method Extracting Observation Data by Spatial Factor for Analysis of Selective Attention of Vision (시각의 선택적 주의집중 분석을 위한 공간요소별 주시데이터 추출방법)

  • Kim, Jong-Ha;Kim, Ju-Yeon
    • Science of Emotion and Sensibility
    • /
    • v.18 no.4
    • /
    • pp.3-14
    • /
    • 2015
  • This study has extracted observation data by spatial factor for the analysis of subjects' selective attention with the objects of public space at the entrance of subway stations. The methods extracting observation data can be summarized as the following. First, the frequency analysis by lattice was prevalent for those methods, but there is a limitation to the analysis of the observation data. On the contrary, the method extracting observation data by factor applied in this study can make it clear if any sight is concentrated on any particular factors in a space. Second, the results from the extracted data corresponding to the observation area can be objectified while the method setting up the observation area by applying the radius of fovea. Third, time-sequential trace of observation results of relevant factors was possible through hourly analysis of spatial factors. The consideration of the results of "corresponding spatial scope" which is the object of this study will reveal that the more the observation time, the less the degree of attention it receives. Fourth, the frequency of observation superiority was applied for the analysis of the sections with selective attention by time scope; this revealed that men and women had intensive observation in time scope I (52.4 %) and in time scope IV (24.0 %), respectively.

Model for predicting ground surface settlement by field measuring and numerical analysis in shield TBM tunnel (현장계측과 수치해석에 의한 쉴드TBM 터널의 지표침하 예측모델)

  • Kim, Seung-Chul;Ahn, Sung-Youll;Lee, Song;Noh, Tae-Kil
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.3
    • /
    • pp.271-287
    • /
    • 2013
  • In this study, more convenient model(S-model) for predicting ground surface settlement is developed through comparing field monitoring data of the domestic subway applied shield TBM method with conventional equation & numerical analysis. Sample stations are chosen from whole of excavation section and lateral & vertical ground surface settlement characteristic with excavation are analysed. Based on analysis result, through the comparison with actual monitoring data, the model that is possible to compute maximum surface settlement and settlement influence area is suggested with assumption that lateral surface settlement forms are composed relaxed zone and elastic zone. In addition, vertical ground surface settlement patterns with excavation are similar to cubic-function and S-model with assumption that coefficients are function of tunnel diameter and depth is suggested. Consequently, the ground surface settlement patterns are significantly similar to actual monitoring data and numerical method result. Thus, as a result, when tunnels are excavated using sheild TBM through rather soft weathered soil & rock layer, prediction of ground surface settlement with excavation using convenient S-model is practicable.

Using Ridge Regression to Improve the Accuracy and Interpretation of the Hedonic Pricing Model : Focusing on apartments in Guro-gu, Seoul (능형회귀분석을 활용한 부동산 헤도닉 가격모형의 정확성 및 해석력 향상에 관한 연구 - 서울시 구로구 아파트를 대상으로 -)

  • Koo, Bonsang;Shin, Byungjin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.5
    • /
    • pp.77-85
    • /
    • 2015
  • The Hedonic Pricing model is the predominant approach used today to model the effect of relevant factors on real estate prices. These factors include intrinsic elements of a property such as floor areas, number of rooms, and parking spaces. Also, The model also accounts for the impact of amenities or undesirable facilities of a property's value. In the latter case, euclidean distances are typically used as the parameter to represent the proximity and its impact on prices. However, in situations where multiple facilities exist, multi-colinearity may exist between these parameters, which can result in multi-regression models with erroneous coefficients. This research uses Variance Inflation Factors(VIF) and Ridge Regression to identify these errors and thus create more accurate and stable models. The techniques were applied to apartments in Guro-gu of Seoul, whose prices are impacted by subway stations as well as a public prison, a railway terminal and a digital complex. The VIF identified colinearity between variables representing the terminal and the digital complex as well as the latitudinal coordinates. The ridge regression showed the need to remove two of these variables. The case study demonstrated that the application of these techniques were critical in developing accurate and robust Hedonic Pricing models.