• Title/Summary/Keyword: Subtraction method

Search Result 432, Processing Time 0.029 seconds

Low-complexity de-mapping algorithms for 64-APSK signals

  • Bao, Junwei;Xu, Dazhuan;Zhang, Xiaofei;Luo, Hao
    • ETRI Journal
    • /
    • v.41 no.3
    • /
    • pp.308-315
    • /
    • 2019
  • Due to its high spectrum efficiency, 64-amplitude phase-shift keying (64-APSK) is one of the primary technologies used in deep space communications and digital video broadcasting through satellite-second generation. However, 64-APSK suffers from considerable computational complexity because of the de-mapping method that it employs. In this study, a low-complexity de-mapping method for (4 + 12 + 20 + 28) 64-APSK is proposed in which we take full advantage of the symmetric characteristics of each symbol mapping. Moreover, we map the detected symbol to the first quadrant and then divide the region in this first quadrant into several partitions to simplify the formula. Theoretical analysis shows that the proposed method requires no operation of exponents and logarithms and involves only multiplication, addition, subtraction, and judgment. Simulation results validate that the time consumption is dramatically decreased with limited degradation of bit error rate performance.

Processing of dosage units and design of database schema for formulas in Korean medicine ontology (한의 온톨로지 처방의 용량 단위 가공과 데이터베이스 스키마 설계)

  • Sang-Kyun, Kim;Yong-Taek, Oh;MyungKu, Lee
    • Herbal Formula Science
    • /
    • v.30 no.4
    • /
    • pp.233-240
    • /
    • 2022
  • Objectives : This study aims to propose a processing method for dosage units of medicinal materials and the database schema to manage formula data in Korean medicine ontology. Methods : All dosage units of medicinal materials are collected from the seven textbooks that contain formula data of Korea medicine ontology. Dosages are converted to Arabic numerals and units that are frequently used are converted to representative units. Database schema is designed for processing and managing the formulas and medicinal materials with dosage units. Results : Seven representative units are selected out of 77 units. They will be used in the addition or subtraction of medicinal materials in a formula support system. The remaining units will be made available for references. Conclusions : EMR or chart programs used in clinical hospitals contain formula data that is already standardized. However, the formula data in Korean medicine literature and textbook is not refined, so it is necessary to process the dosages and units of medicinal materials to use in the formula support system. This result is a processing method to utilize the formula data of Korean medicine textbooks and it will be implemented this method in the established formula support system in the future.

Adaptive Spectral Subtraction Method Using SNR and Masking Effect for Robust Speech Recognition in Noisy Environments (잡음환경에 강인한 음성인식을 위해 SNR과 마스킹 효과를 이용한 적응 스펙트럼 차감법)

  • 김태준;김종훈;이경모;이정현
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10b
    • /
    • pp.580-582
    • /
    • 2004
  • 스펙트럼 차감과정에서 발생하는 잔류 잡음을 제거하는 방법으로 파라메터를 이용하는 적응 스펙트럼 차감법이 있다. 이는 파라메터를 증가시켜 잔류 잡음을 감소시키는 방법이지만 파라메터를 과도하게 증가시킬 경우 음성 왜곡이 발생한다. 따라서, 적절한 파라메터를 추출하기 위하여 SNR이나, 마스킹 효과 등을 이용한 방법들이 제안되었으나 과도한 잡음의 제거로 인한 음성 왜곡 문제와 낮은 SNR에서 부정확한 파라메터의 추출 문제는 여전히 해결해야 할 과제로 남아있다. 본 논문은 기존의 SNR을 이용한 방법에 마스킹 효과를 적용한 수정된 적응 스펙트럼 차감법을 제안한다. 제안된 방법에서는 마스킹 임계치를 이용하여 잡음 추정값을 재 계산 항으로써 SNR을 향상시켰고, 이를 이용하여 파라메터를 추출함으로써 성능을 개선했다 성능평가 결과, 제안한 차감법을 적용한 음성신호를 고립단어 음성인식 시스템에 적용했을 때 기존의 방법 보다 인식률이 향상된 것을 확인할 수 있었다.

  • PDF

People Counting System using Raspberry Pi

  • Ansari, Md Israfil;Shim, Jaechang
    • Journal of Multimedia Information System
    • /
    • v.4 no.4
    • /
    • pp.239-242
    • /
    • 2017
  • This paper proposes a low-cost method for counting people based on blob detection and blob tracking. Here background subtraction is used to detected blob and then the blob is classified with its width and height to specify that the blob is a person. In this system we first define the area of entry and exit point in the video frame. The counting of people starts when midpoint of the people blob crosses the defined point. Finally, total number of people entry and exit from the place is displayed. Experiment result of this proposed system has high accuracy in real-time performance.

A Study on Speech Enhancement Method Based on the New Spectral Subtraction with Subband Estimation (새로운 서브밴드 추정-스펙트럼 차감법에 기반한 음성향상방법에 관한 연구)

  • 주상현;김수남;김기두
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.10B
    • /
    • pp.1360-1366
    • /
    • 2001
  • 이 논문에서는, 잡음환경에서의 음성 향상을 위해서 일반적인 주파수 차감법에 기반한 새로운 형태의 방법을 제안한다. 기존의 방법들이 각각의 주파수 성분에 대해 잡음 및 음성스펙트럼을 추정하는데 비해, 본 논문에서는 주파수 대역을 여러 개의 서브밴드로 대역을 나누어 각각의 서브밴드에 대해서 잡음 및 음성의 스펙트럼을 추정한다. 본 논문에서는 잡음 스펙트럼을 추정하기 위하여 최소추적(Minima Tracking) 방법을 선택하였고, 필터링 방법으로는 스펙트럼 차감법에 기반한 Mel-Scaled 필터뱅크를 이용한 새로운 방법을 제안하였다. 모의실험결과, 기존의 방법들에 비해 음성구간에서의 SNR의 향상정도는 입력 SNR이 -10∼4dB의 범위에서 향상된 결과를 얻었다. 또한 전 구간에 대해서도 다른 알고리즘들 보다 향상된 결과를 얻었다.

  • PDF

Speech Parameters for the Robust Emotional Speech Recognition (감정에 강인한 음성 인식을 위한 음성 파라메터)

  • Kim, Weon-Goo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.12
    • /
    • pp.1137-1142
    • /
    • 2010
  • This paper studied the speech parameters less affected by the human emotion for the development of the robust speech recognition system. For this purpose, the effect of emotion on the speech recognition system and robust speech parameters of speech recognition system were studied using speech database containing various emotions. In this study, mel-cepstral coefficient, delta-cepstral coefficient, RASTA mel-cepstral coefficient and frequency warped mel-cepstral coefficient were used as feature parameters. And CMS (Cepstral Mean Subtraction) method were used as a signal bias removal technique. Experimental results showed that the HMM based speaker independent word recognizer using vocal tract length normalized mel-cepstral coefficient, its derivatives and CMS as a signal bias removal showed the best performance of 0.78% word error rate. This corresponds to about a 50% word error reduction as compare to the performance of baseline system using mel-cepstral coefficient, its derivatives and CMS.

Speech Recognition in the Car Noise Environment (자동차 소음 환경에서 음성 인식)

  • 김완구;차일환;윤대희
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.2
    • /
    • pp.51-58
    • /
    • 1993
  • This paper describes the development of a speaker-dependent isolated word recognizer as applied to voice dialing in a car noise environment. for this purpose, several methods to improve performance under such condition are evaluated using database collected in a small car moving at 100km/h The main features of the recognizer are as follow: The endpoint detection error can be reduced by using the magnitude of the signal which is inverse filtered by the AR model of the background noise, and it can be compensated by using variants of the DTW algorithm. To remove the noise, an autocorrelation subtraction method is used with the constraint that residual energy obtainable by linear predictive analysis should be positive. By using the noise rubust distance measure, distortion of the feature vector is minimized. The speech recognizer is implemented using the Motorola DSP56001(24-bit general purpose digital signal processor). The recognition database is composed of 50 Korean names spoken by 3 male speakers. The recognition error rate of the system is reduced to 4.3% using a single reference pattern for each word and 1.5% using 2 reference patterns for each word.

  • PDF

Diagnosis of Subclavian Steal: Contrast Enhanced 3D MR Angiography vs 2D TOF

  • 이호규;김건언;최중곤;서대철
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.136-136
    • /
    • 2001
  • Purpose: Subclavian steal refers to the retrograde flow of blood in a vertebral artery that supplies t ipsilateral shoulder and arm caused by proximal subclavian artery stenosis or occlusion. T purpose of this exhibit is to demonstrate MR findings of subclavian steal on contrast-enhanc 3D (CE 3DMRA) and 2D TOF MR angiography. Method: Four patients(men 3 and women 1, age: 28-78years) with subclavian steal obtained both CE 3DMRA and digital subtraction angiography(DSA) including subclavian arterie Sequential imaging was undertaken during first pass after double dose of Gd-DTPA (0 mM/kg) Injected by a power injector. Coronal source images were obtained with coronal D-fast low angle shot sequence(TR/TE/flip angle=3.8/l.3/35, acquisition time= 10sec/one measurement). Precontrast imaging was subtracted from enhanced images and maximu intensity projection was done. 2D time-of-flight MR angiography(2D TOF) of the carot bifurcation was added in all cases with post-saturation. All studies were review retrospectively.

  • PDF

Face and Hand Activity Detection Based on Haar Wavelet and Background Updating Algorithm

  • Shang, Yiting;Lee, Eung-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.8
    • /
    • pp.992-999
    • /
    • 2011
  • This paper proposed a human body posture recognition program based on haar-like feature and hand activity detection. Its distinguishing features are the combination of face detection and motion detection. Firstly, the program uses the haar-like feature face detection to receive the location of human face. The haar-like feature is provided with the advantages of speed. It means the less amount of calculation the haar-like feature can exclude a large number of interference, and it can discriminate human face more accurately, and achieve the face position. Then the program uses the frame subtraction to achieve the position of human body motion. This method is provided with good performance of the motion detection. Afterwards, the program recognises the human body motion by calculating the relationship of the face position with the position of human body motion contour. By the test, we know that the recognition rate of this algorithm is more than 92%. The results show that, this algorithm can achieve the result quickly, and guarantee the exactitude of the result.

Sensing method of multi-component forces and moments using a column structure (기둥을 이용한 다축 힘/모멘트 감지 방법에 관한 연구)

  • Shin, H.H.;Kang, D.I.;Park, Y.K.;Kim, J.H.;Joo, J.W.;Kim, O.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.837-841
    • /
    • 2001
  • The column-type sensing element in building and mechanical construction parts was designed as three forces and three moments sensor by attaching strain gages approximately. Compared to conventional multi-component sensor, the designed sensor can solve the problem about low stiffness and high cost. The radius of the column was designed analytically and compared with finite element analysis. The coupling errors between components were minimized by using addition and subtraction procedure of signals. The fabricated sensor was tested by using a deadweight force standard machine and a six-component force calibration machine in Korea Research Institute of Standards and Science(KRISS). The calibration showed that the multi-component force/moment sensor had coupling error less than 19.8 % between $F_x$ and $M_y$ components, and 9.0 % in case of other components.

  • PDF