• Title/Summary/Keyword: Substrate removal rate

Search Result 159, Processing Time 0.024 seconds

A Characteristics of Biogas Recovery and Biodegradability of Piggery Wastewater Using Granule of Two-Phase Anaerobic Process with UASB (UASB를 적용한 이상 혐기공정 granule에 의한 양돈폐수의 바이오가스 생성과 생분해 특성 평가)

  • Oh, SungMo;Bae, Yoon Sun;Park, Chul Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.3
    • /
    • pp.315-322
    • /
    • 2007
  • The purpose of this study was to investigate the biodegradability and performance of organic removal and methane production rate when treating piggery wastewater using a granule of two-phase anaerobic process applied UASB. BMP test was conducted as simple means to monitor relative biodegradability of substrate and to determine methane production of an organic material. The two-phase anaerobic process is consisted of a continuous flow stirred-tank reactor (CFSTR) for the acidification phase and an Upflow Anaerobic Sludge Blanket reactor (UASB) for the methanogenesis. The acidogenic reactor played key roles in reducing the periodically applied shock-loading and in the acidification of the influent organics. A stable maximum biogas production rate was 400mL. The methane contents ranged from 73 to 80% during the experimental period. It is known that most of the removed organic matter was converted to methane gas, and the produced biogas might be high quality for its subsequent use.

Effect of Recalcitrant Organics on Bio-kinetic Coeffcient and Biodegradable in Box-mill Wastewater (판지공장 폐수 중 난분해성 유기물질이 동력학적 계수 및 생분해에 미치는 영향)

  • Cho, Yong Duck;Lee, Sang Wha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.329-338
    • /
    • 2006
  • The research aims to provide the basic data for practical applications by correlating the bio-kinetic coefficients with the load of recalcitrant organic matter in box-mill wastewater. The activated sludge process was employed to a Wastewater disposal plant in an industrial setting, increase of consequently leading to the organic load. The parameter values derived by Monod-kinetic analysis were as follows:specific substrate removal rate $K_{max}=0.17day^{-1}$, half saturation constants $K_s=60.37mg/l$, decay coefficient $K_d=0.142day^{-1}$, microbial yield coefficient y = 0.388mg/mg, and max specific growth rate ${\mu}_{max}=0.006day^{-1}$. In view of biodegradability, the $TCOD_{Mn}/TBOD_5$ ratios of inflow and outflow were 1.07 and 1.41, and the $SCOD_{Mn}/SBOD_5$ ratios of inflow and outflow were 1.10 and 1.50, respectively. The higher $TCOD_{Mn}/TBOD_5$ ratio of outflow indicated that metabolites of a microorganism have accumulated in the cells.

The Basic Design Parameters and Effluent Characteristics for Aerobic Fixed Biofilm Reactor (호기성 고정생물막 반응기에서 기초 설계인자와 유출수의 성상)

  • 박태주;송승구
    • KSBB Journal
    • /
    • v.7 no.3
    • /
    • pp.235-245
    • /
    • 1992
  • A number of experiments to treat wastewater of a dye plant were conducted to investigate the basic design parameters and effluent characteristics for aerobic fixed biofilm reactor upon the variation of organic loading rate. The media used for this study were SARAN 4000 D with specific surface area $153m^2/m^3$, and 1000 D with specific surface area $307m^2/m^3$. The influent COD concentration ranged from 1250 to 4080 mg/L. Substrate removal and variation of biomass concentration were observed. At the beginning, the effluent quality was poor but improved as the time passed. However the effluent quality became seriously deteriorated when the media clogged. At influent COD of 1250mg/L, the effluent COD varied little, even if the organic loading rate increased from 0.63 to 2.5kg COD/$m^3$/day. It was also noted that the design parameters for activated sludge process could be applied to an aerobic fixed biofilm process under the experimental conditions.

  • PDF

Hydrodynamics and parametric study of an activated sludge process using residence time distribution technique

  • Sarkar, Metali;Sangal, Vikas K.;Bhunia, Haripada
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.400-408
    • /
    • 2020
  • Hydrodynamic study of Activated Sludge Process (ASP) is important to optimize the reactor performance and detect anomalies in the system. Residence time distribution (RTD) study has been performed using LiCl as tracer on a pilot scale aeration tank (AT) and ASP, treating the pulp and paper mill effluent. The hydraulic performance and treatment efficiency of the AT and ASP at different operating parameters like residence time, recycle rate was investigated. Flow anomalies were identified and based on the experimental data empirical models was suggested to interpret the hydrodynamics of the reactors using compartment modelling technique. The analysis of the RTD curves and the compartment models indicated increase in back-mixing ratio as the mean hydraulic retention time (MHRT) of the tank was increased. Bypassing stream was observed at lower MHRT. The fraction of dead zone in the tank increased by approximate 20-25% with increase in recycle rate. The fraction of the stagnant zone was found well below 5% for all performed experiments, which was under experimental error. The substrate removal of 91% for Chemical oxygen demand and 96% for Biochemical oxygen demand were observed for the ASP working at a hydraulic mean residence time 39 h MRT with a 20% recycling of activated sludge.

Comparison of particle removal efficiency between the physical cleaning methods in the fabrication of liquid crystal displays (LCD 제조공정에서 물리적 세정법의 미립자 제거효율 비교 연구)

  • Park, Chang-Beom;Yi, Seung-Jun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.795-801
    • /
    • 2010
  • As the fabrication technology of LCDs (Liquid Crystal Displays) advances, the size of mother glass substrates is getting larger, and the fabrication process is becoming finer. Accordingly, the importance of cleaning processes grows in the fabrication process of LCDs. In this study, we have compared and evaluated the particle removal efficiency for three different methods of physical cleaning, which are brush, bubble jet, and aqua/air cleaning. Using the seventh generation glass substrate, the particle removal efficiency has been investigated by changing operation conditions such as a flow rate of deionized water, pressure, contact depth between a brush bristle and a glass substrate, and so forth. In the case of brush cleaning, the cleaning efficiency barely changes after a critical point when the contact depth is varied. While the cleaning efficiency of bubble jet cleaning is almost independent of pressure, that of aqua/air cleaning is affected by pressure up to a critical point, but is not changed after it. We note the brush cleaning is the most effective among the three cleaning methods under our experimental conditions.

Automatic Control Of Dissolved Oxygen In Activated Sludge Aeration Tank

  • Park, Kwang-Soo;Heo, Nam-Hyo;Lee, Hae-Goon;Han, Gee-Baek;Kim, Chang-Won
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.2
    • /
    • pp.113-119
    • /
    • 1999
  • The quality of the effluent from an activated sludge aeration tank can deteriorate when the substrate removal rate decreases due to an abrupt reduction in the DO concentration, which is affected by such operating conditions as the loading rate, temperature, wastewater composition, and so on. In this research, a DO control system that includes a PI (proportional-integral) controller/Hiraoka controller was developed and applied to a pilot-scale activated sludge process, then its acceptability was estimated. The applicability of the respiration rate to DO control was also estimated. The respiration rate indicated a variety of input organic loading rates, which is the main disturbance to the DO concentration in an aeration tank. When the influent concentration incrementally decreased and increased between CODcr 1,000 mg/l and 100 mg/l, the control system with a PI controller exhibited a good llperformance-the average DO concentrations were 2.00$\pm$0.14 mg/l and 1.88$\pm$0.15 mg/l (set value was 2.0 mg/l), respectively, and the settling time was just 10 minites. When the control system was operated for 4 days, the DO concentration was 1.99$\pm$0.18 mg/l and 32.6% of the air flowrate was saved. However, the fluctuations in the respiration rates and air flowrates were severe, which could be harmful to the stability of the biomass and mechanical stability of the blower. A possible approach to solve this problem may be the simultaneous control of the loading rate and DO concentration.

  • PDF

Cu dry etching by the reaction of Cu oxide with H(hfac) (Cu oxide의 형성과 H(hfac) 반응을 이용한 Cu 박막의 건식식각)

  • Yang, Hui-Jeong;Hong, Seong-Jin;Jo, Beom-Seok;Lee, Won-Hui;Lee, Jae-Gap
    • Korean Journal of Materials Research
    • /
    • v.11 no.6
    • /
    • pp.527-532
    • /
    • 2001
  • Dry etching of copper film using $O_2$ plasma and H(hfac) has been investigated. A one-step process consisting of copper film oxidation with an $O_2$ plasma and the removal of surface copper oxide by the reaction with H(hfac) to form volatile Cu(hfac)$_2$ and $H_2O$ was carried but. The etching rate of Cu in the range from 50 to 700 /min was obtained depending on the substrate temperature, the H(hfac)/O$_2$ flow rate ratio, and the plasma power. The copper film etch rate increased with increasing RF power at the temperatures higher than 215$^{\circ}C$. The optimum H(hfac)/O$_2$ flow rate ratio was 1:1, suggesting that the oxidation process and the reaction with H(hfac) should be in balance. Cu patterning using a Ti mask was performed at a flow rate ratio of 1:1 on 25$0^{\circ}C$\ulcorner and an isotropic etching profile with a taper slope of 30$^{\circ}$was obtained. Cu dry patterning with a tapered angle which is necessary for the advanced high resolution large area thin film transistor liquid-crystal displays was thus successfully obtained from one step process by manipulating the substrate temperature, RF power, and flow rate ratio.

  • PDF

Effects of Biomass Concentration and Sludge Loading Rate on Bioactivity and Membrane Fouling in a Submerged Membrane Bioreactor System (침지형 분리막 생물반응기에서 미생물 농도와 슬러지 부하에 따른 미생물 활성 변화와 막오염 특성 연구)

  • Tak Tae-Moon;Bae Tae-Hyun;Jang Gyoung-Gug
    • Membrane Journal
    • /
    • v.14 no.4
    • /
    • pp.289-297
    • /
    • 2004
  • In this study, membranes were coupled to a sequencing batch reactor for simultaneous removal of organic matter and nitrogen, and the influences of MLSS (mixed liquor suspended solid) concentration and the sludge loading rate on membrane fouling and bioactivity were investigated. The amount of membrane fouling slightly increased with MLSS concentration at both non-aeration and aeration conditions, but effect of MLSS concentration was more significant at aeration condition. Although the effect of MLSS concentration on membrane fouling was found to be insignificant at low concentration level, extremely low sludge loading, which were generated by the maintenance of large amount of biomass in the reactor, caused severe membrane fouling, and air scouring effect decreased significantly in this condition. Specific bioactivity was constantly reduced as sludge loading rate decreased. In spite of high MLSS concentration over 17,000 mg/L, the activity of the reactor decreased at extremely low sludge loading rate presumably due to the lower oxygen transfer and the competition of biomass to deficient substrate.

Optimum management of tomato side shoot removal in winter (저온기 토마토 재배시 적정 측지관리방법 구명)

  • Kim, Sung Eun;Lee, Jae Eun;Sim, Sang Youn;Lee, Moon Haeng;Kim, Young Shik
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.309-313
    • /
    • 2014
  • This research was conducted to establish recommendable side shoot management methods in the growth and yield of tomato in winter. A cherry tomato, $^{\circ}{\times}Unicorn^{\circ}{\pm}$ (Monsanto Korea, Korea) was cultivated in coconut coir in the form of bag as substrate. There were four treatments related to side shoot removal methods; 1) To remove all side shoots and also each one of three leaves which gives shade to each cluster attached below (UP-FL), 2) To remove all side shoots and also each one of three leaves which gives shade to each cluster only with fruit attached below (UP-FR), 3) To remove all side shoots (AS-All), and 4) To remain two leaves of each side shoot coming from right below each cluster (AS-Part). The number of malformed leaves were more in UP-FL, UP-FR, AS-All, and AS-Part in descending order, which showed the severe the removal of leaves the more the malformed leaves. The malformed leaves were diminished after the development stage the second or third cluster bloomed. The yields until fifth cluster were not different among the treatments. Therefore removal of side shoots and leaves recommends not to be done severely in early growth stage when tomato plants are cultivated in winter.

Isolation of Microorganisms and Development of Microbial Augmentation for Treatment of Industrial Wastewater containing Ammonium Nitrogen (암모니아성 질소함유 산업폐수처리를 위한 미생물의 분리 및 복합미생물제제의 개발)

  • Lee, Myoung-Eun;Mun, Seo-Jin;Kwon, Do-Hyuck;Suh, Hyun-Hyo
    • Journal of Life Science
    • /
    • v.30 no.2
    • /
    • pp.129-136
    • /
    • 2020
  • For effective treatment of wastewater containing ammonium nitrogen (NH4-N), AT2, AT9, and AT12 strains, having high total organic carbon (TOC) removal capability, and FN47, possessing excellent ammonia nitrogen removal capability present in the activated sludge in the aeration tank of food wastewater treatment plants, were isolated and identified. The cells of these isolated strains were used for microbial augmentation with FIW-1 in the defatted rice bran as a medium to treat industrial wastewater. The investigation of the cultural characteristics of these isolated strains in the aeration tank showed that the affinities for substrate of the isolated strains were extremely high, of which AT12 (Alcaligenes sp. AT12) was the highest among the isolated strains. Ammonium nitrogen removal efficiency in the food wastewater was 71% in the isolated strain FN47 (Microbacterium sp. FN47) treatment group. When only activated sludge was added in the lab scale pilot using food wastewater during continuous culture experiment, the TOC removal efficiency was 63%. Meanwhile, the removal efficiency of 92% was obtained when the microbial augmentation FIW-1 for wastewater treatment was applied. In addition, the chemical oxygen demand (COD) level from the effluent wherein microbial augmentation FIW-1 was input for the initial three days in the wastewater treatment site experiment showed a treatment rate of about 43%, which was increased to 62% after an elapse of 5 days.