• 제목/요약/키워드: Substation Automation

검색결과 136건 처리시간 0.026초

IEC61850 기반의 통신방식을 이용한 스마트 배전운영시스템용 보호협조 알고리즘 개발 (Development of Protection Coordination Algorithm for Smart Distribution Management System using Communication Method based on IEC61850)

  • 추철민;윤상윤;권성철;추경용;진영규;최면송
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1412-1419
    • /
    • 2012
  • In this paper, we propose the protection coordination algorithm using communication methode based on IEC 61850. The communication protocol in power distribution management system has been issued by IEC standard, IEC61850 of them, which was made for substation automation system, has researched to apply into power distribution system, even though the standard is not a suitable for the system. In smart distribution management system' launched in 2009, the communication network based on the ethernet network for IEC 61850 has been designed to apply the self-healing concept, which is to perform the system protection through the communication between remote terminal units(RTU) according to the standard. However, it is first time to apply the scheme in the real. Thus, this paper proposed the protection algorithm and consideration for applying communication method and introduced the result of demonstration.

변전소 자동화를 위한 지능형 솔루션 개발에 대한 연구 (A Study on the Development of Intelligent Solution for Distribution Substation Automation)

  • 고윤석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.250-252
    • /
    • 2005
  • 배전 변전소 무인화는 변전소 자동화 기술을 기반으로 하기 때문에 변전소 운영의 안정성과 신뢰성을 확보하기 위해서는 변전소내의 각 설비들이 원격감시제어, 자율제어 그리고 사고를 사전에 방지하거나 인지하기 위한 설비진단을 지원할 수 있는 디지털 지능형 전력설비(IED)로 진화돼야 한다. 따라서 본 연구에서는 변전소내의 각 설비 IED드로부터 제공되는 데이터 정보로부터 무인화 변전소 운영의 안정성과 신뢰성을 확보할 수 있도록 지원하는 무인화 변전소 운전지원 지능형 솔루션을 설계하고, 디지털 수배전반의 지능형 제어모듈의 추배전 변전소 무인화는 변전소 자동화 기술을 기반으로 하기 때문에 변전소 운영의 안정성과 신뢰성을 확보하기 위해서는 변전소내의 각 설비들이 원격감시제어, 자율제어 그리고 사고를 사전에 방지하거나 인지하기 위한 설비진단을 지원할 수 있는 디지털 지능형 전력설비(IED)로 진화돼야 한다. 따라서 본 연구에서는 변전소내의 각 설비 IED드로부터 제공되는 데이터 정보로부터 무인화 변전소 운영의 안정성과 신뢰성을 확보할 수 있도록 지원하는 무인화 변전소 운전지원 지능형 솔루션을 설계하고, 디지털 수배전반의 지능형 제어모듈의 추론 메카니즘, 상위 감시 제어 시스템과의 자유로운 데이터 교환을 위한 통신기법을 설계한다. 론 메카니즘, 상위 감시 제어 시스템과의 자유로운 데이터 교환을 위한 통신기법을 설계한다.

  • PDF

변전자동화 시스템 성능검증 및 실증시험 (Performance verification and test for substation automation system)

  • 장병태;최창열;김병헌;박진홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.258-259
    • /
    • 2006
  • 국내외적으로 전력산업분야의 가장 큰 화두중 하나는 변전소 단위의 디지털화이며 특히 국외에서는 국제표준 변전자동화 시스템 연구와 제품개발 등에 인력을 집중 투자하고 있다. 국제적으로 지금까지 축적된 변전소 관련 제반 기술력 및 경험 둥을 바탕으로 전 세계적으로 단일화시키고 표준화된 변전소 자동화 규격인 IEC 61850 (Communication networks and systems in substations) 규격이 제정되었으며 따라서 향후 전력 관련 기업은 시스템 엔지니어링 기술, 전력기기 공급능력, 유지/보수/운영기술 등을 종합적으로 보유하고 자산 및 위험관리를 종합적으로 제공할 수 있어야만 세계시장에서 생존할 수 있다. 또한 전력기기를 수출하는 국내업체는 향후 IEC(International Electrotechnical Commission) 등 국제표준에 따른 전력설비를 개발하지 않으면 수출경쟁력을 잃게 될 것이다. 이러한 세계화 추세에 발맞추어 한국전력공사와 관련 업체들은 공동으로 2005년 10월부터 6년의 기간으로 "디지털 기술기반의 변전소 자동화 시스템 개발" 사업을 진행 중에 있으며 특히 한국전력공사는 변전자동화 시스템의 성능검증 및 실증시험 절차를 구축하기 위한 과제를 수행 중이다.

  • PDF

계통전압.무효전력 제어에 관한 연구 (A study for the system voltage and reactive power control)

  • 송길영
    • 전기의세계
    • /
    • 제14권3호
    • /
    • pp.10-17
    • /
    • 1965
  • This paper presents a method of the voltage-reactive power control in the long and short range operations and introduces a conception, "optimum control pattern." The optimum control pattern, aiming at the over-all system control, is defined as the optimum voltage distribution which minimizes the system operating cost under the conditions that the specified power be supplied and the system voltage be kept within the specified bounds. The following procedure was adopted to obtain this optimum pattern. In the first place, a power system was divided into three blocks, namely, load, substation and generator. Lagrange's, multiplier method is applied to each block in turn, paying attention only at the operating voltage distribution. Phase angles at each bus are then modified so that the continuity of active power is maintained. This procedure may be called "block relaxation method with Lagrange's multipliers." In a long range operation, this control pattern determines the optimum installation capacity of reactive power sources. In a short range operation, it also gives the reference state of real time control and the optimum switching capacity of reactive power souces. The real time control problem is also studied from the standpoint of cooperation of control devices such as generators, shunt capacitors, shunt reactors and ratio load controllers. A proposal for the real time control will contribute to the automation of power system operation in the near future. in the near future.

  • PDF

IEC-61850 기반의 154kV M.Tr Bay IED 적용 사례 (154kV Main TR. Bay IED Based On IEC-61850)

  • 노재근;오재훈;김병철;고철진;양항준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.764-765
    • /
    • 2011
  • 전력시스템을 더 효율적으로 운용하고, 더 지능화하려는 노력은 2000년대 초 다양한 각도로 진행되어 왔다. 그리하여 중장기 국책과제인 전력IT 과제를 필두로 여러 지능화 기기들이 국 내외 유관업체를 통하여 지속적으로 성장을 하였고 현재에 이르러서는 과제의 틀이 아닌 비즈니스 모델 창출을 위하여 여러 시범 사업들이 구상되고 있는 중이다. 이는 전력IT 의 핵심 아이템이라 할 수 있는 IEC-61850 국제 표준 프로토콜 기반의 IED (Intelligent Electronic Devices) 개발과 어울려 변전소의 직접 현장 적용을 통한 엔지니어링 기술 개발에 역점을 두고 있는 상태이다. 변전소 자동화 (S/A: Substation Automation)의 영역이 점점 현실화 되어가고, 전 세계 적용 Site의 폭발적인 증가로 힘입어 이젠 선택이 아닌 필수가 되고 있고, 적용에서 끝이 아닌 다양한 엔지니어링 Tool 의 개발, 진단 시스템의 융합 등과 더불어 계속 발전해나가고 있다. 본 논문에서는 이러한 시대적 흐름을 바탕으로 당사에서 참여중인 한국전력 154kV S/A 시범사업 및 스마트그리드 실증사업을 통하여 현장 적용된 154kV Main Transformer 용 IED 솔루션의 적용 사례를 소개하고자 한다. S/A 시범사업의 경우, 한국전력 충주본부 풍동S/S에서 올해 초 설계되어 현재 현장 엔지니어링을 1차 마무리한 상태이며, 스마트 그리드 실증사업은 제주 성산S/S에서 진행 중이며 이도 마무리를 하는 단계에 이르러, 그동안 현장적용의 문제점을 논의하고, 이에 대한 대응책을 서로 공유하며 정리하고 있다. 참고로 본 논문에서는 IEC-61850 프로토콜 구현에 대한 것은 다루지 않으며, 다만 현장제어에 필요하고 또한 구현되어 있는 기능에 대한 전반적인 내용을 다루게 된다.

  • PDF

지상변압기의 내부 보호장비 작동을 위한 MCA 보호협조에 대한 연구 (A study on Protective Coordination of MCA for Performing of the Pad Mounted Transformer's inside Protective Device)

  • 현승윤;김창환
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.5-7
    • /
    • 2022
  • KEPCO's plan is undergoing a trial operation to replace the open-loop section with ring main units configuration where underground distribution lines are installed, by linking the multi-way circuit breakers auto (MCA) on the power side of each pad-mounted transformer. However, ring main units application mentioned above may cause the ripple effects, when implementing the configuration without a study of protection coordination. Because ring main units with classical pre-set protection devices contribution in fault condition didn't consider yet. For the reliable ring main units operation, it is necessary to resolve several protection issues such as the protection coordination with substation side, prevention of the transformer inrush current. These issues can radically deteriorate the distribution system reliability Hence, it is essential to design proper protection coordination to reduce these types of problems. This paper presents a scheme of ring main units' configuration and MCA's settings of time-current curves to preserve the performance of protection coordination among the switchgears considering constraints, e.g. prevention of the ripple effects (on the branch section when a transformer failure occurs and the mainline when a branch line failure occurs). It was confirmed that the propagation of the failure for each interrupter segment could be minimized by applying the proposed TCC and the interrupter settings for the MCAs (branch, transformer). Further, it was verified that the undetected area of the distribution automation system (DAS) could be supplemented by having the MCA configurated ring main units operate first, instead of the internal protection equipment in the transformer such as the fuse, STP when a transformer failure occurs.