• Title/Summary/Keyword: Submerged square cylinder

Search Result 3, Processing Time 0.02 seconds

Numerical Study of Drag Forces Acting on a Submerged Square Cylinder in Steady Flow Condition (정상류 수몰 사각실린더에 작용하는 항력 특성에 관한 수치모의 연구)

  • Lee, Du Han;Kim, Young Joo;Rhee, Dong Sop
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3950-3960
    • /
    • 2014
  • In this study, the drag forces on a submerged square cylinder were analyzed using a three dimensional hydrodynamic model. The numerical results were compared with the experimental results to check the reliability of the numerical simulations, and the characteristics of the drag forces with the relative depths were analyzed by analyzing the pressure acting on the cylinder surface, which are normally difficult to measure experimentally. The numerical results showed that the drag forces acting on a submerged square cylinder originate mainly from the pressure forces, and component of the shear forces decreased with increasing relative depth. The pressure coefficient distributions showed that in the case of a low relative depth, a relatively high pressure was formed in the front of a cylinder, and a relatively low pressure was formed in the rear, which gives a high drag coefficient. In a high relative depth, the pressure in the front decreased and pressure in the rear increased, which is a similar phenomenon to that normally observed in two dimensional square cylinder flow. The effect of the static pressure was analyzed and the surface elevation difference between the front and rear zone of a cylinder has a limited effect on the drag forces. Finally, the numerical results showed that the drag forces acting on a submerged square are dominated by the dynamic pressure formed by three dimensional flow and the distribution of local surface elevation.

NUMERICAL SIMULATION OF FLOW PAST A SQUARE CYLINDER SUBMERGED UNDER THE FREE SURFACE (자유수면 아래 정방형 실린더 후류 유동에 관한 수치해석적 연구)

  • Ahn, Hyungsu;Yang, Kyung-Soo;Park, Doohyun
    • Journal of computational fluids engineering
    • /
    • v.20 no.4
    • /
    • pp.51-57
    • /
    • 2015
  • In the present study, two-dimensional numerical investigation of flow past a square cylinder beneath the free surface has been performed to identify the effects of presence of the free surface. An immersed boundary method was adopted for implementation of the cylinder cross-section in a Cartesian grid system. Also, a level-set method was used to capture the interface of two fluids. To prevent transition to three-dimensional flow, Reynolds number chosen for this simulation was 150. The cases for Froude number 0.2 and gap ratio(h/D) between 0.25 and 5.00 were examined. At the specific Reynolds number, we study the effects of gap ratio on flow characteristics around a square cylinder by computing flow fields, force coefficients and Strouhal number.

EFFECTS OF THE FREE SURFACE ON THE FLOW PATTERN PAST A SQUARE CYLINDER (정방형 실린더 주위 유동패턴에 대한 자유수면의 영향)

  • Ahn, Hyungsu;Yang, Kyung-Soo
    • Journal of computational fluids engineering
    • /
    • v.22 no.1
    • /
    • pp.81-87
    • /
    • 2017
  • The characteristics of flow past a square cylinder submerged under the free surface have been numerically studied. An immersed boundary method was adopted for implementation of the cylinder cross-section in a Cartesian grid system. Also, a level-set method was used to capture the interface of the two fluids. The case for Reynolds number 150 was examined. At the specific Reynolds number, by varying the gap ratio(0.25, 0.40, 0.55, 0.70, 1.00, 1.50, 2.50, 5.00) the effects of the free surface on the force coefficients and Strouhal number of vortex shedding were identified. The presence of the free surface very close to the cylinder significantly affects the shedding pattern, resulting in considerable deviation of the force coefficients and Strouhal number from those of the single-phase flow. In addition, the influence of Froude number was considered in this study. By increasing Froude number(0.2-0.4), flow topology change was identified at the specific gap ratios(0.40, 0.70, 1.50, 5.00).