• Title/Summary/Keyword: Submerged Membrane

Search Result 160, Processing Time 0.022 seconds

Performance evaluation of submerged membrane bioreactor for model textile wastewater treatment

  • Guembri, Marwa;Saidi, Neila;Neifar, Mohamed;Jaouani, Atef;Heran, Marc;Ouzari, Hadda-Imene
    • Membrane and Water Treatment
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2020
  • Submerged Membrane bioreactor (SMBR) is one of the last techniques that allow a high quality of treated industrial effluents by coupling biological treatment and membrane separation. Thus, this research was an effort to evaluate performance of a SMBR treating a model textile wastewater (MTWW). Different SMBR operating parameters like mixed liquor suspended solids (MLSS) and Dissolved oxygen concentration, hydraulic retention time (HRT), and nutrients addition (N and P) have been investigated. MTWW (influent to the SMBR) was generated using the reactive azo-dye, Novacron blue FNG (100mg/L feed concentration). Results of MTWW treatment using SMBR under optimal operating conditions (MLSS, 4.2-13.3g/L; HRT, 4 days; pH, 6.9-7.2; conductivity, 400-900 μS/cm and temperature, 19.4-22.2 ℃) showed that COD and blue colour treatment performances are between 94-98% and 30-80%, respectively. It is concluded that SMBR can be used in large scale textile wastewater treatment plants to improve effluent quality in order to meet effluent discharge standards.

The Effect of Filling Step on the Removal Efficiency and Filtration Performance in the Operation of Submerged Membrane-Coupled Sequencing Batch Reactor (침지형 막결합 연속회분식 반응기의 운전에서 폐수의 도입단계가 제거효율과 여과성능에 미치는 영향)

  • Kim, Seung-Geon;Lee, Ho-Won;Kang, Yeung-Joo
    • Membrane Journal
    • /
    • v.21 no.3
    • /
    • pp.263-269
    • /
    • 2011
  • In the operation of submerged membrane-coupled sequencing batch reactor, the effect of filling step on the removal efficiency and filtration performance were investigated. Two sets of operation modes, the filling step located in the beginning of aerobic step (Mode-1) and the beginning of anoxic step (Mode-2), during 89 days were conducted. There was no wide difference in the COD removal and filtration performance between two sets of operation modes. But in the removal efficiency of nutrients (total nitrogen and total phosphorous), Mode-2 was more effective than Mode-1. In the case of Mode-2, average removal efficiencies of COD, total nitrogen, and total phosphorous were 99.1, 73.3, and 77.3%, respectively.

Observations of Treatment Efficiency and Fouling in Submerged Membrane Filtration Treating High-Turbidity Source Water (고탁도 원수대응 침지식 멤브레인 여과에서 공기폭기 및 용액조성에 따른 파울링 및 처리효율 관찰)

  • Jang, Hoseok;Byun, Youngkwon;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.27 no.1
    • /
    • pp.77-83
    • /
    • 2017
  • Transient behavior of fouling resistance was observed with a laboratory-scaled, submerged microfiltration membrane system treating high-turbidity source water consisting of inorganic silica particles and humic acid. Fouling mitigation efficiency with inorganic silica particles caused by aeration was reduced significantly as both humic acid and calcium ion existed together. Scanning electron microscopic observations showed that humic acid was adsorbed onto the surface of inorganic silica particles in the presence of calcium. Turbidity removal was achieved almost completely by submerged MF system regardless of feed compositions. However, the $UV_{254}$ removal of humic acid was improved in the presence of both calcium and inorganic silica particles. Additionally, increasing air-flow rate tended to increase $UV_{254}$ removal efficiency higher than 80%. This may be caused by back-transport of humic acid enhanced by inorganic silica particles providing surface for organic adsorption in the presence of calcium.

Permeation Characteristics of the Submerged Membrane Module Using the Rotating Disks (회전원판을 이용한 침지형 분리막 모듈의 투과특성)

  • Chung Kun-Yong;Cho Young-Su;Kim Jong-Pyo
    • Membrane Journal
    • /
    • v.16 no.1
    • /
    • pp.51-58
    • /
    • 2006
  • The permeation experiments were carried out for the submerged membrane module equipped with self-designed rotating disks in order to determine the effect of fouling reduction and the optimum operating conditions as a function of operating time. Kaolin and bentonite particles were used to prepare various concentrations of feed solution. Every experiment was continued until 60 minutes at various rotating disk speeds up to 120 rpm. The suction pressure for kaolin solutions decreased to 28% by using rotating disk to decrease the fouling. Also, the optimum permeation flux decreased as kaolin concentration increased, and became 60 to 70 LMH for 0.4 wt% of kaolin solution. The suction pressure for bentonite experiment approached to 0 mmHg at 30 LMH and above 80 rpm rotating disk speed.

Influence of Membrane Material and Structure on Fouling of a Submerged Membrane Bioreactor (침지형 막 분리 활성슬러지법에서 막의 재질 및 구조가 파울링에 미치는 영향)

  • Choi, Jae-Hoon;Kim, Hyung-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • This work was performed to evaluate the effect of membrane material and structure on fouling in a submerged membrane bioreactor(MBR). Three types of microfiltration membranes with the same pore size of 0.1 $\mu$m but different materials, polytetrafluoroethylene (PTFE), polycarbonate(PCTE) and polyester(PETE), were used. While PETE membrane exhibited the most rapid flux decline throughout the operation, PCTE and PTFE had a similar tendency with regard to permeability. Difference in permeability between PETE and the other membranes gradually decreased with time, which was probably due to chemical cleaning. The higher TOC rejection of PETE membrane could be attributable to its faster fouling, resulting from a larger amount of foulants to get attached to the membrane in a shorter time. DOC fractionation using a DAX-8 resin showed that the composition of each fraction between the supernatant and permeates did not change significantly with operation time, indicating that membrane hydrophilicity/hydrophobicity was not a dominant factor affecting to MBR fouling in this study. Compared to other membranes, the fouling of PETE membrane was more influenced by pore clogging (irreversible fouling), which would probably contribute to a higher organic rejection of the PETE membrane.

Processing Characteristics of the Condensed Wastewater Resulting from Food Waste Disposal using a Submerged Polyethylene Hollow Fiber Membrane (음식물 소멸기에서 발생하는 응축폐수의 Polyethylene 침지형 중공사막을 이용한 처리 특성)

  • Ryu, Jae-Sang;Jeon, Tae-Bong;Kim, Jin-Ho;Chung, Kun-Yong
    • Membrane Journal
    • /
    • v.20 no.2
    • /
    • pp.127-134
    • /
    • 2010
  • This study is conducted about the system that reduces organism after fermenting food waste from a food waste disposal equipment, divides gas made when food waste is fermented into gas and water, and then sends gas to a reactor again, condenses water, and apply it to the MBR system with submerged MF hollow fiber membranes. A submerged MF hollow fiber membrane module was installed to a food waste disposal equipment and a water treatment system made by Bio Hitech Co,. Ltd. to process food waste generated from a staff cafeteria in a H institute for 90 days. For initial seeding of a food waste disposal equipment, 305 kg of rice bran, chaff, and sawdust as well as 1,648 kg of food were input during the operation, and 1,600 L of condensed wastewater occurred. Fermented by-product after finishing running a food waste disposal equipment was 386 kg and its reduction was shown to be 80%. The organism was processed by applying submerged MF hollow fiber membrane module to the MBR system of condensed wastewater, and the result shows reduction rates were BOD 99.9%, COD 97.5%, SS 98.6%, T-N 54.6% and T-P 34.7% and the total colon bacillus was perfectly eliminated.

Pretreatment Process for Performance Improvement of SIES at Kori Unit 2 in Korea

  • Lee, Sang-Jin;Yang, Ho-Yeon;Shin, Sang-Woon;Song, Myung-Jae
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.12-27
    • /
    • 2004
  • Pretreatment process consisted of submerged hollow-fiber microfiltration(HMF) membrane and spiral-wound nanofiltration(SNF) membrane has been developed by NETEC, KHNP for the purpose of improving the impurities of liquid radioactive waste before entering Selective Ion Exchange System(SIES). The lab-scale combined system was installed at Kori NPP #2 nuclear power plant and demonstration tests using actual liquid radioactive waste were carried out to verify the performance of the combined system. The submerged HMF membrane was adopted for removal of suspended solid in liquid radioactive waste and the SNF membrane was used for removal of particulate radioisotope such as, Ag-l10m and oily waste because ion exchange resin can not remove particulate radioisotopes. The liquid waste in Waste Holdup Tank (WHT) was processed with HMF and SNF membrane, and SIES. The initial SS concentration and total activity of actual waste were 38,000ppb and $1.534{\times}10_{-3}{\mu}Ci/cc$, respectively. The SS concentration and total activity of permeate were 30ppb and lower than LLD(Lower Limit of Detection), respectively.

  • PDF

SND in the Fixed Media Tank of Membrane-BNR Process Treating Low C/N Wastewater (저농도 하수 유입 Membrane-BNR공정내 고정상담체 호기조에서의 SND)

  • Jeong, Yong-Chul;Lee, Jung-Yeol;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.3
    • /
    • pp.328-332
    • /
    • 2008
  • This research was about T-N removal efficiency of oxic reactor in which fixed media submerged from Membrane BNR(An+Ax+Ox) process. This experiment was implemented by using fixed media and changing DO concentration in the oxic reactor. Nitrification efficiencies of all modes were more than 98%. When no media was in the oxic reactor, T-N removal efficiency was only 47.4%, while it were shown from 60.3% to 67.4% with packed media, which indicated improved efficiency of 27~42%. The removal efficiencies of TCOD and BOD were more than 89%, 98% respectively, which could satisfy the guideline of advanced sewage reclamation by Department of Environment. When DO concentration in the packed oxic-media tank was 0.5~1.0 mg/L, T-N removal efficiency was low, which resulted from insufficient nitrification in the oxic reactor. Therefore, DO concentration of bulk solution needs to be kept more than 1.0 mg/L to induce higher nitrification efficiency in the reactor in which media was submerged. Also, the selection of DO concentration is important to prevent media from being clogged.

Reusing of Dye Wastewater through Combined Membrane Process (조합형 분리막 공정을 이용한 염색폐수의 재이용 연구)

  • 박헌휘;최호상
    • Membrane Journal
    • /
    • v.12 no.2
    • /
    • pp.67-74
    • /
    • 2002
  • Submerged membrane bioreactor(SMBR) and reverse osmosis(R/O) systems treated dye wastewater for reusing of industrial water. The permeate fluxes of SMBR at 20-25 cmHg of lab. test and field test were 10 LMH($1/m^2$.hr) all test. Removal efficiencies of CODcr, $COD_{Mn}$ and T-N were 93%, 90% and 60% in the SMBR, respectively The advanced treatment of combined process(SMBR+R/0) was accomplished for increasing the removal efficiency of non-biodegradable materials and T-N. Therefore, the removal efficiency of T-N obtained in 80% above, then nitrogen concentration was under 15 mg/L. The combined process(SMBR+R/0) was suitable to reuse of the dye wastewater.