• Title/Summary/Keyword: Subjective comfort

Search Result 295, Processing Time 0.027 seconds

A Study on Wearing Test of Protective Clothing against a Toxic Substance (유해물질 차단을 위한 방호복의 착용실험에 관한 연구)

  • Chung, Myung-Hee;Park, Soon-Ja;Shin, Jung-Sook;Koshiba, Tomoko;Tamura, Teruko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.11 s.158
    • /
    • pp.1626-1635
    • /
    • 2006
  • The purpose of this study was to search for comfortable protective clothing for waste incinerator workers. The experimental protective clothing came in two types: one whose outer side made use of polypropylene film, and the inner side, a non-woven rayon fabric processed with charcoal with a 10% density (CF): and one whose outer side made use of polyolefine and polyamide films, and the inner side, a non-woven polypropylene fabric (NNCF). Experiments were conducted on five healthy adult women whose average age was 21. These experiments were conducted at a climate chamber, in which the temperature and relative humidity were set below $28{\pm}1^{\circ}C\;and\;50{\pm}10%$, respectively. Measured were the rectal temperature, the skin temperature, the sweating rate, the weight loss, the heart rate, the blood pressure, the temperature, and the relative humidity of a microclimate and subjective sensation. These were measured within a period of 60 min, consisting of a 20-min stable period, a 20-min exercise period (walking exercise for 2 miles/hr on a treadmill), and a 20-min recovery period. Through this experiment, the differences between the human body's physiological reactions to CF and NNCF clothing, and the human body's comfort levels when wearing these, were determined.

Evaluation of Physiological Responses and Comfort of Protective Clothing Using Charcoal Printing (숯 날염가공한 방호복의 인체생리반응 및 쾌적성 평가)

  • Chung Myung-Hee;Park Soon-Ja;Shin Jung-Sook;Koshiba Tomoko;Tamura Teruko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.6 s.154
    • /
    • pp.981-991
    • /
    • 2006
  • The purpose of this study was to determine the practicability of an experimental protective clothing by identifying the human body's physiological responses to it as well as the human body's comfort level when wearing it, particularly with the use of a processed charcoal material. The experimental protective clothing came in two types: one whose outer side made use of polypropylene film, and the inner side, a non-woven rayon fabric; and one whose inner side made use of a non-woven fabric processed with charcoal with a 10% density. Experiments were conducted on five healthy adult women whose average age was 21. These experiments were conducted at a climatic chamber, in which the temperature and relative humidity were set below $28{\pm}1^{\circ}C\;and\;50{\pm}10%$, respectively, and were measured within a period of 60min, consisting of a 20-min rest period, a 20-min exercise period, and a 20-min recovery period. Based on the results of this study, the efficiency of the processed charcoal material was reviewed, and a database requiring the production of more functional and comfortable protective clothing materials was established.

Qualitative Research on Actual Wearing Conditions and Satisfaction of Rifle Shooting Clothing (소총 사격복 착용실태 및 만족도에 관한 질적연구)

  • Lee, Ah Lam;Park, Soozin;Kim, Na Yun;Nam, Yun Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.39 no.4
    • /
    • pp.517-528
    • /
    • 2015
  • This study investigates actual wearing conditions and satisfaction based on qualitative research for rifle shooting clothing. The survey was conducted in two ways: in-depth interviews of 4 rifle shooting experts and subjective questionnaires for 18 active rifle shooters. They agreed on the importance of rifle shooting wear to minimize body sway and contribute to a balanced body posture. Most rifle shooters purchase made-to-measure rifle shooting clothing at a domestic store, but the clothing often needs extra adjustments due to an uncomfortable fit. Current fabric for rifle shooting clothing consists of a cotton canvas with a polyester mix; however, rifle shooters are unsatisfied with its stiffness in hot and wet conditions. Due to the specific fabric features, rifle shooting clothing should not be washed despite year-round use that represents another point of dissatisfaction. Rifle shooters always wear specially designed underclothes to improve shooting skills and comfort sensation. In conclusion, it is necessary to develop well fitted and comfort rifle shooting clothing that could improve shooters skills based upon this study.

A Study on the Working Clothes for Korea Railroad -Focused on Winter Upper Garment- (한국철도공사 작업복에 관한 연구 (제1보) -동복 상의를 중심으로-)

  • Kim, Ji-Won;Choi, Hei-Sun;Ryou, Heun-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.2
    • /
    • pp.308-318
    • /
    • 2009
  • The purpose of this study was to develop the functionally improved winter work clothing for the Korean railroad workers. Based on the questionnaires, the sample clothing for the Korean railroad workers was produced. The design, materials, and patterns were modified to increase mobility and comfort of workers. Water-repellent treatment was added to the material in order to decrease the dirt and stains while working. Also the reflective strips were added to chest and back of the upper garment in order to increase visibility and safety of the workers. In terms of the design and pattern underarm of the sleeve and side panel of the bodice were put in together and action pleats at the back were inserted in order to decrease the pullback of the armpit and scapular area and increase mobility of the arm movement. Also the patterns of the elbows areas were modified to increase mobility of joint. The prototype was evaluated an objective assessment and subjective assessment to compare to the existing working uniform. Assessment group was consisted of 5 subject groups and 11 expert groups and evaluated external appearance and adaptability to the movements. According to the results, the prototype was evaluated better than the existing working uniform in appearance and adaptability except height of collar. A field test was conducted to compare the prototype and the existing working uniform. The field tests were performed by 6 workers in the Korean railroad. According to the results, the prototype was improved in terms of adaptability and comfort.

Evaluation of Wearing Comfort and Ease of Working Pants for Improved Mobility (동작가동성이 향상된 작업복 하의 개발을 위한 시판 제품의 착용감 및 여유량 평가)

  • Lee, Hyojeong;Eom, Ran-i;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.4
    • /
    • pp.752-770
    • /
    • 2017
  • This study provides a size specification and ease for the development of pants for working clothes in the construction industry according to season. We collected and measured the size specification of 4 types of Spring/Fall pants, 4 types of winter brushed bonding pants, and 4 types of winter padded pants. Subjective comfort evaluation and analysis of ease sensation were performed for all products on 12 subjects. The average size specifications for the pants according to seasons were as follows. Spring/Fall pants had 74.0/80.0cm waist size (relaxed/maximum stretched) and 104.0cm hip size. Winter brushed bonding pants had 76.0/83.4cm for waist size and 106.0cm for hip size. Winter padded pants had 71.5/84.0cm for waist size and 112.8cm for hip size. When designing a pattern by comparing product size specification and subject body size, the recommended ease is 0.2/7.2cm for waist size (relaxed, maximum stretched) and 13.6cm for hip size for Spring/Fall pants, and 0.2/6.2cm for waist size and 11.6cm for hip size of winter brushed bonding pants, and -5.3/7.2cm for waist size and 19.4cm for the hip size of winter padded pants.

Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments (1) -Thermophysiological Response of Human Body in Local Cooling- (고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest 연구(1) -Local Cooling에 따른 인체의 온열생리학적 특성-)

  • Kwon, Oh Kyung;Kim, Jin-A;Kim, Tae Kyu
    • Fashion & Textile Research Journal
    • /
    • v.2 no.3
    • /
    • pp.265-271
    • /
    • 2000
  • Heat stress results in fatigue, a decline in strength, alertness., and mental capacity. The problem is compounded when high humidity exists. To help relieve worker heat stress, many types of cooling units are marketed. While workers may experience some cooling, critical body core temperatures often continue to elevate. This study was designed to find the effects of three kinds of cooling vest with portable frozen gel strips on thermophysiological parameters and on temperature and humidity within clothing. The heart rate, rectal, and skin temperature as well as sweat rate and clothing microclimate were measured during 80 min in 5 healthy males. Inquiries were also made into the subjective rating thermal, humidity comfort, and fatigue sensations. The main findings in our experiments are as follows: (a) Physiological parameters such as rectal temperature was the lowest in garb A1, intermediate in garb A, and the highest in garb A2 throughout the experiment. And mean skin temperature was the lowest in garb A, intermediate in garb A1, and the highest in garb A2; (b) Temperature and humidity within clothing (back) were garb in Al, intermediate in garb A, and the highest in garb A2. But the temperature and humidity within clothing (chest) were garb in A, intermediate in garb A1, and the highest in garb A2; (c) Most participants (4 out of 5 persons) answered that they felt more comfortable and fatigueless in garb A1 than in garb A and A2. It is concluded that local cooling in garb A1 of the upper torso could physiological reduce the thermal strain in participants wearing cooling vest.

  • PDF

Subjective Wear Test and Fit of Women's Sports Underwear Made of Cool-Touch Fabric (냉감소재로 제작한 여성 스포츠 언더웨어의 피트성과 착용시 주관적 평가)

  • Kim, Soyoung;Lee, Heeran;Choi, Jiyoung;Hong, Kyunghi
    • The Korean Journal of Community Living Science
    • /
    • v.28 no.4
    • /
    • pp.505-514
    • /
    • 2017
  • Although studies on the development of cool touch fabrics have been conducted widely, the effects of fitted pattern on enhancing the cooling sensation are insufficient. To investigate the effect of cool-touch fabric and fit of women's sports underwear, 3D and 2D patterns of sleeveless top and sports leggings were constructed. The performance of cool touch was tested by the Qmax value and wear test with nine subjects. Objective fit evaluation was observed by 3D virtual clothing using Clo software. Subjects rated wearing sensation such as 'cooling sensation, fit, wear comfort and preferences of purchase' using Likert's scale in the environmental chamber at $25^{\circ}C$, 45 %RH. The Qmax value of the cool touch fabric was higher than that of the PET fabric, which was well reflected in 'cooling sensation', especially in the case of a tight-fitted 3D pattern. The cooling sensation of the cool-touch fabric was not significantly elevated with 3D tight pattern as long as the size of the 2D pattern was similar to that of 3D pattern. However, the purchase preference was highly correlated with 3D fit and wear comfort.

Effects of Wearing COVID-19 Protective Face Masks on Respiratory, Cardiovascular Responses and Wear Comfort During Rest and Exercise (휴식과 운동 중 COVID-19 대응 보건용 마스크 착용이 호흡·심혈관계 반응 및 착용감에 미치는 영향)

  • Jung, Jae-Yeon;Kang, ChanHyeok;Seong, Yuchan;Jang, Se-Hyeok;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.22 no.6
    • /
    • pp.862-872
    • /
    • 2020
  • This study explores the effects of facemasks on respiratory, thermoregulatory, cardiovascular responses during exercise on a treadmill and at rest. Five male subjects (25.8 ± 0.8 y, 171.8 ± 9.2 cm in height, 79.8 ± 28.1 kg in weight) participated in the following five experimental conditions: no mask, KF80, KF94, KF99, and N95. Inhalation resistance was ranked as KF80 < KF94 < N95 < KF99 and dead space inside a mask was ranked as KF80 = KF94 < N95 < KF99. The surface area covered by a mask was on average 1.1% of the total body surface area. The results showed no significant differences in body core temperature, oxygen consumption (VO2), carbon dioxide production (VCO2), heart rate or subjective perception among the five experimental conditions; however, cheek temperature, respiratory ventilation and blood pressure were greater for KF80 or KF94 conditions when compared to KF99 or N95 conditions (p<0.05). The differences among mask conditions are attributed to the dead space or specific designs (cup type vs pleats type) rather than the filtration level. In addition, the results suggest that improving mask design can help mitigate respiratory resistance from increased filtration.

A Comparative Study on the Effects of Three Types of Pillows on Head-neck Pressure Distribution and Cervical Spine Alignment

  • Kyeong-Ah Moon;Ji-Hyun Kim;Ye Jin Kim;Joo-Hee Park;Hye-Seon Jeon
    • Physical Therapy Korea
    • /
    • v.31 no.1
    • /
    • pp.8-17
    • /
    • 2024
  • Background: Sleep accounts for approximately one-third of a person's lifetime. It is a relaxing activity that relieves mental and physical fatigue. Pillows of different sizes, shapes, and materials have been designed to improve sleep quality by achieving an optimal sleep posture. Objects: This study aimed to determine which pillow provides the most comfortable and supports the head and neck during sleep, which may enhance sleep quality. Methods: Twenty-eight healthy adults (19 males and 9 females) with an average age of 29 years participated in this cross-sectional study. This experiment was conducted while the participants laid down for 5 minutes in four different pillow conditions: (1) no pillow (NP), (2) neck support foam pillow (NSFP), (3) standard microfiber filled pillow (SFP), and (4) hybrid foam pillow (HFP). The head-neck peak pressure, cranio-vertebral angle in supine (CVAs), cranio-horizontal angle in supine (CHAs), chin-sternum distance (CSD), and muscle tone of sternocleidomastoid were analyzed using one-way repeated measures analysis of variance (ANOVA). The significance level was set at p < 0.05. Results: The head-neck peak pressure was the highest in the NSFP condition, followed by the NP, SFP, and HFP conditions. The CVAs, CHAs, and CSD of the SFP were lower than those of the other pillows. Muscle tone was the highest in the NP condition, followed by the of NSFP, HFP, and SFP conditions. The participants subjective comfort level in both the supine and side-lying postures was highest in the HFP condition, followed by the SFP and NSFP conditions. Conclusion: This study can be used to establish the importance of pillow selection for high-quality sleep. The results of this study, suggest that a hybrid pillow with a good supportive core and appropriate fluffiness can maintain comfort and correct cervical spine alignment during sleep.

Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments(2) - Comparison in Terms of Thermophysiological Properties Between New Cooling Vest and Standard Cooling Vest - (고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest연구(2) - 개발제품의 온열생리학적특성 -)

  • Kwon, Oh-Kyung;Kim, Tae-Kyo;Kim, Jin-A
    • Fashion & Textile Research Journal
    • /
    • v.2 no.4
    • /
    • pp.346-352
    • /
    • 2000
  • The purposes of this study are finding out thermophysiological properties throughout wearing experiment with standard cooling vest as well as providing data in order to design and apply more comfortable cooling vest. To do this study, we produced cooling vest newly. 1. Rectal temperature was ascended approximately from $37.2^{\circ}C$ to $38.05^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from $32.8{\sim}36.5^{\circ}C$, it was descended $1.0{\sim}1.1^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower $0.5^{\circ}C$. 2. While wearing developed cooling vest, it was found that they had lower tendency than standard cooling vest. Specifically in case of temperature within clothing (chest) $0.2{\sim}2.0^{\circ}C$ in case of humidity within clothing 2~8%RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. 3. In subjective sensation, standard cooling vest made negative response during experiment period from participants, but new cooling vest was nearing to comfortable area. It was con finned from above conclusions that wearing developed product is more effective in terms of comfort and reduction of heat stress in situation of working in hot environment.

  • PDF