The purposes of this study were to determine the actual state of the indoor thermal environment in apartment units and to analyze the relationship between the living factors and indoor thermal elements. The field surveys consisted of measurements of physical elements and observations of living factors. In addition, the residents of 20 apartment units were interviewed to survey their subjective response. Field surveys were carried out from January to March 2007. Measuring elements were air temperature, globe temperature, and relative humidity. The results showed that the average of indoor temperature for the houses was $21.2{\sim}27.2^{\circ}C$, while 4 houses exceeded the comfort zone. The average of globe temperature for the houses was $21.3{\sim}27.5^{\circ}C$, while 6 houses exceeded the comfort zone. The mean relative humidity was $19.5{\sim}58.8%$, which is a relatively dry condition. The residents' average clothing value was $0.39{\sim}0.89$ clo(average 0.68 clo). The average thermal sensation vote on each room was $4.2{\sim}4.8$, which is 'neutral' to 'slightly warm'. Living factors had significant effect on indoor temperature in regression analysis were ventilation time(outdoor air exchange), opening time of door through balcony, and gas cooker use time.
The purpose of this study was to find out the present condition of indoor thermal environment and to investigate the environmental needs of the elderly through the measurement of outdoor and indoor physical thermal environment elements and the questionary survey of the response to thermal environment in two welfare facilities for the aged in Taegu during summer in 2001. The 38 residents among the total of 134 residents were asked to record their feelings. The result of this study was as follows. The indoor thermal environment in the facilities subjected leer this study was seemed to be comfortable comparatively. But the values of mean indoor temperature measured were about 1.6-1.8$^{\circ}C$ higher than that of a existing domestic research suggested as thermal comfort zones for the elderly during summer, and most residents fe1t somewhat hot in inner space. And the value of indoor relative humidity in one facility was out from the range of comfort humidity(40-70%). Also there were differences by the geographical location between the two.
Transactions of the Korean Society of Automotive Engineers
/
v.15
no.6
/
pp.108-113
/
2007
This study aims to find equivalent comfort contours, reciprocal of frequency weighting curves, for vertical steering wheel vibration. Psychophysical responses were measured from twelve male subjects by using magnitude estimation of relative discomfort due to vertical steering wheel vibrations of magnitude of 0.1 to 1.58 $m/s^2$ in the frequency range of 4 to 250 Hz. Relative discomfort were estimated with a reference vibration of 0.4 $m/s^2$ at 31.5 Hz. Equivalent comfort contours were produced from the median of sensation magnitudes judged by twelve subjects, which showed variation in the shapes with increase of vibration magnitude. A shape of the contour came close to the perception threshold curve with decrease of vibration magnitude. When the vibration magnitude increases, the shape changed close to those in the references of Hong and et al (2003). It is also recommended frequency weighting curves for vertical steering wheel vibration must be expressed as a function of vibration magnitude as well as frequency.
Purpose: This study compared the effect of two oral care agents on preventing stomatitis and discomfort for acute leukemic patients. Methods: A total of forty patients was enrolled and randomly assigned to sodium bicarbonate or chlorhexidine group. WHO oral toxicity scale was used for measuring stomatitis and Beck's subjective oral discomfort scale for evaluating oral comfort. Data was collected from August 2009 to February 2010. The data was analyzed using Chi-square test, Fisher's exact test, and Mann-Whitney test. Results: Data analyzed was thirty five one. The incidence of stomatitis was 47.4%, 68.8% in sodium bicarbonate and chlohexidine group respectively. The onset of stomatitis was about the 10th and 9th day after chemotherapy initiation, and the duration was 8.0 and 8.67 day respectively. The severity of stomatitis was highest on the 21st day after chemotherapy initiation. There were no statistical differences in the status of stomatitis and the levels of oral comfort during treatment periods. Conclusion: Nurses should routinely assess oral cavity and encourage patients to do oral care actively from second to third week after chemotherapy initiation. Also sodium bicarbonate agent can be recommended to for preventing stomatitis.
Journal of the Korean Society of Clothing and Textiles
/
v.24
no.8
/
pp.1115-1124
/
2000
The purpose of this study was 1) to determine physical properties, and subjective evaluation of sensation of sports socks with various type of fiber content and fabric structure, and 2) to develop regression equations for predicting each sensation from physical properties of socks. Thirty healthy male students participated in the wear test with ten replications. The ANOVA, Duncans multiple test, and multiple regression, and paired-t test were used in the statistical analysis, using an SAS package. The results of this study are as follows: 1. 100% cotton socks had higher absorbency and wickability among five different socks. Comfort sensation, tactile sensation and fit sensation of socks were significantly influenced by types of fiber content. People felt that polypropylene socks were less comfortable & slightly tighter, and cotton socks were drier than the other socks. Terry socks were warmer than single jersey socks. 2. The results of the regression analysis showed that tactile sensation of socks after exercise can be predicted from the cube of moisture permeability($R^2$=0.99), and fit sensation can be predicted from drop absorbency, moisture permeability, wickability in wale and weight($R^2$=-0.98).
Proceeding of Spring/Autumn Annual Conference of KHA
/
2008.04a
/
pp.281-284
/
2008
The purposes of this study were to make clear the present condition of indoor thermal environment in apartment units and to analyze the relation of the living factors with indoor thermal elements. The field surveys consisted of measurements on physical elements and observations on living factors and interview on resident's subjective responses were carried out in 20 apartment units. The field surveys were carried out during the $January{\sim}March$ 2007. Measuring elements were air temperature, globe temperature, and relative humidity. As results, the averages of indoor temperature each houses were $21.2{\sim}27.2^{\circ}C$, the number of houses exceed the comfort zone were 4. The averages of globe temperature each houses were $21.3{\sim}27.5^{\circ}C$, 6 houses exceeded the comfort zone. The means of relative humidity were $19.5{\sim}58.8%$, relatively dry condition. The clothing value of residents were $0.39{\sim}0.89$ clo(average 0.68 clo). The average of thermal sensation ratings each room were $4.2{\sim}4.8$, 'neutral'$\sim$'slightly warm'. The results of regression analysis on relations of living factors with the thermal elements are as follow; ventilation time(outdoor air exchange), door opening time with balcony, and gas cooker use time had significant effect on indoor temperature.
Purpose: This study aimed to compare the effects of the Difflam spray 0.3% with the sodium bicarbonate-normal saline spray on oral care for postoperative patients. Methods: The participants were randomly allocated to either the Difflam (n=22) group or the saline solution (n=23) group. The data were collected at the 1-, 4-, 7-, and 10-hour marks after returning to the ward post operation using the Beck's subjective oral discomfort scale, Visual Analogue Scale for sore throat, and portable halitosis detector. Results: The sore throat (F=7.25, p=.001) score significantly decreased after oral care using the Difflam spray 0.3%. However, the difference in the scores of oral comfort (F=0.34, p=.797) and halitosis (F=0.91, p=.443) between the two groups was not statistically significant. Conclusion: These findings suggest that the Difflam spray 0.3% is effective in improving postoperative sore throat. A further study that explores the effect of various oral solutions for postoperative patients is needed to present systemic and effective evidence-based oral care guidelines.
Proceedings of the Korean Society for Emotion and Sensibility Conference
/
1998.04a
/
pp.255-263
/
1998
Dust-free garment prevents contamination which otherwise is caused by skin and clothes to protect from dust or dirt. Therefore, it requires high performance and should function as a working clothes. Clothes are a medium between human and thermal environmental system, and it is required to study human enviroment to ensure comfortableness of clothes and to satisfactorily go along with enviroment .This study investigates the physical and physiological features of dust-free garment used in the clean room at a semiconductor factory in oredr to scientifically clarify what the dust-free garmint is as well as to contribute to the design and development of high performance material and clothes. Three kinds of dust-free fabrics (DFG-I, DFG-II, DFG-III) which are being developed by a local company are used to manufacture dust-free garment. These dust-free garments are dressed and tested in such an enviroment as similar to semiconmemts with temperature at 23${\pm}$1$^{\circ}C$ and humidity at 50${\pm}$5%RH in order to investigate the thermo physiological and psychological features of human body. The results of this study are as follows. The results of this study are as follows. 1.The mean skin temperature was significantly different among the clothes, subjects and experimental time. Temperature tends to rise from the time of exercising load. Continuous motion coupled sealed clothes prevents heat transmittance, and temperature rises in the order of DFG-l, DFG-ll and DFG-lll as time course. 2.As for the skin temperature by local timperature is minimun on the head and torso and increares remarkably at the terminal part of human body. 3. As for the body mass loss was significantly higher in DFG-lll than DFG-l and DFG-ll. 4. Though there is no significant difference in the temperature within clothes among the kind of clothes temperature is 1$^{\circ}C$ higher in the back. Temperature within all the dust-free garments 29.7$^{\circ}C$ in the back and 31.3$^{\circ}C$ in the chest which belong to the comfort zone(31-33$^{\circ}C$). The relative humidity is 39.7%RH in the chest and 33.8%RH in the back which is slightly below the comfort zone(40-60%RH) 5. The thermal sensation belong to the comfort zone regardless of the kinds of clothes. The subjects feels a slight fatigue as times goes. As for the subjective sense of subjects the mean skin temperature as well as temperature and humidity within clothes show similar tendency. This means that they relate with each other.
Jeon, Kyung Soo;Yang, Hee Seung;Jang, Soo Woong;Shin, Hee Dong;Lee, Yun kyung;Lee, Young;Lee, Seul Bin Na;Ahn, Dong Young;Sim, Woo Sob;Cho, Min;Cho, Kyu Jik;Park, Dong Beom;Park, Kwan Soo
Clinical Pain
/
v.19
no.2
/
pp.70-79
/
2020
Objective: We evaluated the efficacy of a newly-developed spinal orthoses (V-LSO) by comparing the stabilizing effect, abdominal pressure, and comfort of 3 different semirigid LSOs (classic LSO, V-LSO, and Cybertech®) during various body movements. Method: Thirty healthy volunteers (23~47 years, 24 males, 6 females) were selected. A dual inclinometer measured the range of motion (ROM) while the participants performed flexion/extension and lateral flexion of the lumbar spine with 3 LSOs. The LSO's pressure on the abdominal surface was measured using 9 pressure sensors while lying, sitting, standing, flexion/extension, lateral flexion, axial rotation, and lifting a box. Comfort and subjective immobilization were analyzed by a questionnaire. Results: V-LSO had a statistically significant effect on flexion over Cybertech®. No significant differences were noted during extension and lateral flexion between the 3 LSOs. The abdominal pressure showed no significant differences while supine. While sitting, standing, and lifting a box, the mean abdominal pressure for V-LSO were significantly higher than those for Cybertech®. During lumbar flexion, the mean abdominal pressures for classic LSO and V-LSO were significantly higher than that of Cybertech®. For extension, lateral flexion and axial rotation, the abdominal pressure for V-LSO was significantly higher than those of classic LSO and Cybertech®. In the subjective analysis, V-LSO and Cybertech® scored best for comfort. Conclusion: The V-LSO and Cybertech® were more comfortable than the classic LSO, and hence, may have improved compliance with decreased discomfort. V-LSO may be superior to the other LSOs in restricting lumbar movement and increasing intraabdominal pressure.
Journal of the Korean Society of Clothing and Textiles
/
v.36
no.10
/
pp.1050-1057
/
2012
This study helps develop a cool body armor that maintains a tight-fit configuration to the body surface and evaluates the performance of newly developed body armor in a wear test. Three types of body armor were used for evaluation. One was a tight fitting body armor that was constructed to improve the degree of fit and ease of movement for Korean soldier using 3D technology. Another was ventilating body armor with attached spacers on the shoulder to reduce the thermal stress on the soldier. The third was a prevailing body armor produced by a Korean body armor company. In order to evaluate the performance of the body armor, a human wear test, a thermal mannequin test, and computational fluid dynamics (CFD) were executed. Five subjects participated in the wear test. Subjective wear sensation, total amount of sweat and dynamic change of clothing microclimate were observed during and after exercise on a treadmill; subsequently, it was found that subjects rated tight fitting body armor and ventilating body armor lighter, drier, and easier to move than the conventional body armor (p<.05). Total amount of sweat was the least in the case of ventilating body armor. The thermal resistance and vapor resistance of the ventilating body armor were improved remarkably. In addition, the skin temperature of the ventilating body armor with spacers was lower than the tight fitting body armor by at least $1^{\circ}C$ in the CFD result. It is noted that thermal-wet comfort of the 3D body armor with ventilating feature is superior to the conventional body armor, especially when the ventilating channel is not closed due to a backpack.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.