• 제목/요약/키워드: Subjective comfort

검색결과 295건 처리시간 0.022초

Indoor Neutral Temperature Range using Temperature and Humidity Perception Assessment

  • Yang, Wonyoung
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.29-37
    • /
    • 2016
  • Purpose: Indoor thermal comfort can be identified by combination of temperature, humidity, and air flow, etc. However, most thermal indexes in regard to thermal comfort are temperature dominant since it has been considered as a significant factor affecting to indoor thermal comfort The purposes of this study are to investigate indoor neutral temperature range of young Koreans with humidity perception, and to introduce a neutral temperature for temperature preference as well as temperature sensation in order to define the neutral temperature range chosen by occupants. It could be used as basic data for heating and cooling. Method: 26 research participants volunteered in 7 thermal conditions ($18^{\circ}C$ RH 30%, $18^{\circ}C$ RH 60%, $24^{\circ}C$ RH 30%, $24^{\circ}C$ RH 40%, $24^{\circ}C$ RH 60%, $30^{\circ}C$ RH 30%, $30^{\circ}C$ RH 60%) and completed subjective assessment in regard to temperature/humidity sensation and preference twice per condition in an indoor environmental chamber. Result: In RH 30%, sensation neutral temperature was $25.1^{\circ}C$ for men and $27.0^{\circ}C$ for women, and preference neutral temperature was $25.5^{\circ}C$ for men and $27.8^{\circ}C$ for women. In RH 60%, sensation neutral temperature was $23.6^{\circ}C$ for men and $25.9^{\circ}C$ for women, and preference neutral temperature was $23.4^{\circ}C$ for men and $26.3^{\circ}C$ for women. Neutral temperature increased with increasing relative humidity. Women were sensitive to humidity changes. Men expressed humidity changes as temperature variations. In most conditions, preference neutral temperatures were higher than sensation neutral temperatures, however, the preference neutral temperature for men in humid condition was lower than the sensation neutral temperature.

감염병 대응 개인보호복의 동작성 및 열적 쾌적성: 보호 수준 및 여성 착용자 체격의 영향 (Mobility and Thermal Comfort Assessment of Personal Protective Equipment for Female Healthcare Workers: Impact of Protective Levels and Body Mass Index )

  • 김도희;전영민;이호준;강경리;이초은;이주영
    • 한국의류산업학회지
    • /
    • 제26권1호
    • /
    • pp.123-136
    • /
    • 2024
  • This study aimed to assess the mobility and thermal comfort of personal protective equipment (PPE) among female healthcare workers, taking into account wearers' physique and PPE protection levels. A total of 16 participants (age: 26.3 ± 8.3 y, height: 161.5 ± 7.3 cm, body weight: 57.1 ± 11.0 kg, BMI: 21.9 ± 3.6), representing diverse body types, underwent four PPE conditions: L (Low_Plastic gown ensemble), M (Medium_Tyvek 400), H (High_Tyvek 800J with Powered Air Purifying Respirator [PAPR]), and E (Extremely high_Tychem 2000 with PAPR, Bib apron, and Chemical-resistant gloves). The mobility protocol consisted of 10 different tasks in addition to donning and doffing. The 10 tasks were repeated twice at an air temperature of 24.3 ± 0.1℃, 59±4%RH. Findings revealed a disproportionate relationship between PPE protection and wearer discomfort. Significant differences in clothing microclimate and total sweat rate were observed between the lowest (L) and highest (E) protection levels (p < 0.01), while distinctions among medium levels were inconclusive. Subjective evaluations favored conditions H and L over M and E (p < 0.05), indicating reduced heat, and humidity, increased comfort, and lower exertion. Instances of mobility discomfort, specially in the small body type group, underscored the need for a suitable PPE size system for Korean adult female medical workers. Furthermore, enhancements in gloves, shoe cover, and PAPR hood designs are essential for improving ease of movement and preventing hindrance.

입원한 암환자의 암피로, 수면의 질 및 환경적 수면장애가 안위에 미치는 영향 (The Influence of Cancer Fatigue, Quality of Sleep, and Environmental Sleep Disturbance on Comfort in Hospitalized Cancer Patients)

  • 김희진;장희경
    • 문화기술의 융합
    • /
    • 제6권4호
    • /
    • pp.643-653
    • /
    • 2020
  • 본 연구는 입원한 암환자가 인식하는 암피로, 수면의 질, 환경적 수면장애 및 안위 간의 관계를 파악하기 위한 서술적 상관관계 연구이다. 대상자는 J시에 위치한 대학병원 암센터에 입원한 성인 암환자 113명을 대상으로 설문조사를 실시하였다. 연구기간은 2019년 9월 17일부터 2019년 11월 5일까지 진행하였으며, 자료 분석은 SPSS/WIN 21.0 프로그램을 이용하여 통계 처리하였으며, independent t-test, one-way ANOVA, Scheffé test, Pearson's correlation coefficient, and stepwise multiple regression으로 분석하였다. 본 연구결과 대상자의 안위는 대상자의 교육수준, 암유형, 방사선 치료유무, 평소운동 유무에 따라 유의한 차이가 있는 것으로 나타났다. 또한 안위는 암피로(r=-.609, p<.001), 수면의 질(r=-.478, p<.001), 환경적 수면장애(r=-.297, p=.001)와 부적 상관관계가 있었으며, 입원한 암환자의 안위에 유의한 영향을 미치는 변인은 암피로(β=-.42, p<.001), 주관적 수면의 질(β=-.30, p=.001), 암유형(β=-.18, p<.015)으로 설명력은 46.1%였다(F=27.24, p<.001). 이러한 결과를 바탕으로 입원한 암환자의 안위 향상을 위해 의료진들의 다학제적 협력을 통해 암피로를 감소시키고, 수면의 질 향상을 통한 안위 증진 프로그램을 개발하는 것이 필요하다.

상반신의 부분별 발한량, 피부온과 주관적 감각 고찰 (The Analysis of the Sweating Rate, Skin Temperature on the Upper Body and Subjective Sensations)

  • 김성숙;김희은
    • 한국의류산업학회지
    • /
    • 제15권6호
    • /
    • pp.993-999
    • /
    • 2013
  • This study aimed to measure the amount of sweating on 12 parts of the upper body using absorption fabric and analyze subjective sensations. The study was conducted with 9 male subjects in climate chamber controled at $30{\pm}0.5^{\circ}C$, and $55{\pm}5%$ RH. The result was that sweating amount of the upper back part was significantly more than upper front part. We assumed that forced convection flow cased by exercise decreased the sweating rate in the front. The skin temperature of upper front body rapidly decreased as soon as exercise starts and gradually increased with cessation of exercise. On the other hand, the skin temperature of palm increased with exercise and showed continuous increasing even exercise stopping all the experimental period. This is caused by thermoregulatory responses through vasodilatation on the peripheral area. Subjective sensations, such as thermal sensation, wet sensation, and thermal comfort showed the highest score at the time of exercise stop. This means the subjects felt more hot, wet, and uncomfortable after exercise stopped. Bur after wiping of sweat, subjective sensation scores were recovered rapidly. The present study has provided more detailed information on the upper body sweat distribution than previously available, which can be used in clothing design, thermo-physiological modeling, and thermal manikin design. We also think that results of the present study will play an important role in making the sweat distribution map.

스포츠 브래지어의 하변 밴드 설계에 따른 압력과 착용감 분석 (Analysis on Pressure and Wearing Sensation according to the Lower Band Design of Sports Brassieres)

  • 이희란;엄란이;이예진
    • 한국의류산업학회지
    • /
    • 제21권1호
    • /
    • pp.67-74
    • /
    • 2019
  • This study aims to investigate the relation between pressure, 3D length change, and subjective pressure sensation in sports brassieres. Seven Korean women in their 20s and 30s were chosen as subjects. In the experiment, the subjects evaluated four types of sports brassieres wherein the lower band was changed. The results of the study were as follows. The pressure according to the measurement position was lower at the front part than at the side and back parts (p<.05), and there was no difference in the pressure according to the brassiere type. It was observed that brassiere C, which had the higher extension band, was elongated more than the other brassieres when worn. In the case of brassiere B, which had a slit in the front center, it was observed that the 3D length of the front part changed very little as the slit spreads, and the back part stretched in a manner similar to those of the other brassieres. Subjective pressure sensation was statistically different only at the front and the side of the lower band. Brassiere B(with a silt) demonstrated the least subjective pressure sensation; the pressure sensation was high when wearing brassieres A and D (p<.05). Brassieres B and C were also preferred for overall comfort. In conclusion, it was observed that the substitution of material and morphological transformation affect subjective sensation.

겨울철 실내 온도에서 내복 착용에 따른 의복 기후와 주관적 감각 (Clothing Microclimate and Subjective Sensations by Wearing Long Johns in Mildly Cold Air)

  • 김명주;이주영
    • 대한가정학회지
    • /
    • 제42권10호
    • /
    • pp.91-104
    • /
    • 2004
  • The purpose of this study was to examine the differences of clothing microclimates and the subjective sensations according to age, gender and clothing weight for $19^{\circ}C$ air temperature. This study was done to gain fundamental data related to saving heating energy and to improve health through wearing underwear (long johns) in lower indoor temperatures. The subjects were divided into four groups (6 young males, 5 young females, 6 old males, 6 old females), and our experiment consisted of three conditions; the first condition was wearing long underwear in $19^{\circ}C$ air (19CUW condition); the second condition was without wearing long underwear in $19^{\circ}C$ air (19C condition); and the third condition was without wearing underwear in $24^{\circ}C$ air (24C condition). The experiment showed that the clothing microclimate temperature and humidity was the lowest in the 19C condition and the highest in the 24C condition irrespective of age and gender. The clothing microclimate in the 19CUW condition was not significantly distinguishable from the other conditions. Clothing microclimate temperature and humidity when the subjects responded thermal comfort was $28\~34^{\circ}C$ and $15\~40\%$RH without any significant difference according to age and gender. For the thermal sensation, the 24C condition was regarded as the warmest environment by the four groups, and the next preference was the 19CUW condition (p<0.001). Young females and old males showed a tendency to feel colder than young males and old females. For the thermal sensation of hands and feet, the young groups felt the warmest in the 24C condition and the coolest in the 19 C condition (p<0.001). However, old males felt neutral for the foot thermal sensation without any significant difference between the three conditions. Old females felt neutral for both the hands and feet thermal sensations without any significant difference between the three conditions. Thermal preference was the highest in the 24C condition for the 4 groups. In the 19CUW condition, for the thermal preference, most young males and females responded 'No change'; on the other hand, mea of the old responded 'Warmer'(p<0.001). It was the 24C condition that the 4 subject groups felt the most thermally comfortable. In the 19CUW condition, over $80\%$ of responses of each group expressed satisfaction and in the 19C condition, over $80\%$ of responses of each group, except young females, expressed satisfaction. In conclusion, in view of the clothing microclimate and subjective sensations, the 24C condition was the condition that gave subjects the least cold stress and the best subjective preference. However, the 19C condition and the 19CUW condition was not such a cold stress as to give healthy subjects a thermal burden.

중년 여성을 위한 냉감기능성 댄스스포츠 상의 개발 (Development of Cool-touch Functional Dancesport Top for Middle-aged Women)

  • 전미화;장정아
    • 한국의류산업학회지
    • /
    • 제22권5호
    • /
    • pp.628-638
    • /
    • 2020
  • This study develops a cool-touch functional Dancesport top for middle-aged women by using cool-touch materials in areas where surface temperature becomes high after exercise. The post-exercise surface temperature of the developed research product was compared and analyzed. In addition, subjective evaluation of cool-touch as well as appearance and movement evaluations were performed. The results are as follows. In designing the research product, a detachable neckband was made using highly-preferred hydrated polymer crystals. A material with high moisture absorption speed was also used in F1, S1, under arm and B5, while a material with good thermal conductivity was used in other parts of the bodice. Deodorant tape with antibacterial and deodorant effects was incorporated in the armpit for additional comfort. As for wear evaluation of the research product, significant differences were found in 10 areas using a material with high moisture absorption speed to compare and analyze the post-exercise surface temperatures of the clothing. The temperature difference between the compared top and the research product in the neckband area was 9.16℃, demonstrating clear cool-touch function in using cool-touch material. In the subjective evaluation of cool-touch function, the results showed high scores when asked about the efficiency of the detachable neckband and the ease of movement when wearing the product. In the appearance evaluation, significant differences were found in 11 items, including redundant folds, tightfit, fit, and design line. The overall mean score of the movement evaluation was 4.6, indicating excellent function for movement.

IAPS 사진을 이용한 이차원 공간의 감성 변화 평가 (Evaluation of Two-Dimensional Space of Human Sensibility Mutation by IAPS)

  • 민병찬;정순철;강인형;최지연;김철중
    • 감성과학
    • /
    • 제6권2호
    • /
    • pp.21-28
    • /
    • 2003
  • 본 연구는 국제정서사진체계(IAPS) 사진 중 이차원 감성을 잘 표현한다고 판단되는 9장의 사진을 선정하고, 이 사진 자극으로 유발된 감성의 변화를 심리ㆍ생리적으로 측정한 후 이차원 감성의 한 축인 각성/이완의 감성변화를 심리ㆍ생리적으로 변별 가능한지를 검증하는 것을 목표로 한다. 각성/이완의 감성변화를 대변하는 Eelectrocardiogram (ECG), Galvanic Skin Response (GSR), Skin Temperature, Respiration 등의 자율신경계 반응을 측정하였다. 자극 제시 후에 주관적 평가를 실시한 바, 각성 〉 불쾌/각성 및 쾌/각성 〉 중립 〉 이완 순서의 4단계로 각성도 감성을 구분할 수 있었다 자율신경계 반응은 각성, 불쾌/각성, 쾌/각성 〉 중립 〉 이완 순서의 3단계로 구분이 가능하였다. 본 연구는 한국인의 이차원 감성을 표현할 수 있는 9장의 사진을 IAPS로부터 선정하였으며, 이차원 감성의 한 축인 각성/이완의 감성 변화를 심리ㆍ생리적평가로부터 변별할 수 있다는 사실을 확인하였다.

  • PDF

Development and Evaluation of Protective Clothing for Rose Farmers

  • Chae, Hyeseon;Kim, Sungchul;Oh, Youngsoon;Lee, Kyungsook;Kim, Hyocher;Park, Soonjee
    • 한국의류학회지
    • /
    • 제40권3호
    • /
    • pp.427-436
    • /
    • 2016
  • Protective clothing developed for rose flower farmers has been evaluated to improve the working conditions. The requirements of rose farmers were first identified to design protective clothing for farmers working with thorny plants. A fit test was conducted to assess the thermal comfort and protective function against thorn pricking to compare and evaluate the usability of developed experimental clothing with existing working clothes. Based on the survey results of rose farmers' requirements, protective clothing was designed in the form of an apron (which was the most preferred after gloves) with a pattern designed for the production of experimental clothing. For the developed protective clothing, the strap and buckle closure method was selected to open the back of the body as much as possible; in addition, sleeves were made in the attachable form of a half-sleeve to protect the arms from the thorns. The fit test of the developed protective clothing and existing working clothes revealed the temperature and humidity inside the developed protective clothing to be significantly different in the back compared to existing work clothes. In addition to thermal sensations, the subjective humidity sensations were statistically significant different in the developed protective clothing compared to existing work clothes. The subjective protective function for thorn pricking was also found to be satisfactory.

The Study on the Physiological Response in Wearing Sportswear in Two Different Environments

  • Kwon, Oh Kyung;Kim, Jin-A
    • 한국의류산업학회지
    • /
    • 제2권5호
    • /
    • pp.416-422
    • /
    • 2000
  • In this study, to find out the physiological reaction of the human body and the sensation of comfort when people are wearing sportswear which is made of waterproof breathable fabrics under general environmental conditions (temperature : $20{\pm}1^{\circ}C$, humidity : $60{\pm}5%RH$, air current : 0.1 m/sec) and rainy environmental conditions (temperature : $20{\pm}1^{\circ}C$, humidity : $60{\pm}5%RH$, air current : 0.1 m/sec, rainfall : 250 1/hr), we made an experiment with sportswear in an artificial climate chamber and studied the thermal physiological response and subjective sensation. Mean skin temperature of the subjects was low and had a big range of fluctuation in rainy environmental conditions of two condition. Temperature started to increase at the beginning of the exercise, reached the maximum at the 2nd level of the exercise and then started to decline. Rectal temperature showed a slighter increase and bigger range of fluctuation in general conditions than in rainy conditions. Except clothing micro climate in rainy conditions, temperature and humidity and their range of fluctuation around back were higher than those around chest. Humidity was high and had wide range of fluctuation in general conditions. Heart rate was 4.4 beats/min higher in general conditions. In subjective test on rainy conditions, the feeling of discomfort increased due to the raindrops fallen on the skin. Unlike that in general conditions, cold sensation increased and humidity sensation reached to the peak after the exercise. In wearing sportswear made of shape memory breathable waterproof fabric, controlling function over a small amount of heat and water was distinctive while it turned out to be not so comfortable over a large amount of heat and water. Through this, the limitation of shape memory breathable waterproof fabric was recognised.

  • PDF