• Title/Summary/Keyword: Sub-array

Search Result 418, Processing Time 0.037 seconds

Feasibility of a Linear Diode Array Detector for Commissioning of a Radiotherapy Planning System

  • Seung Mo Hong;Uiseob Lee;Sung-woo Kim;Youngmoon Goh;Min-Jae Park;Chiyoung Jeong;Jungwon Kwak;Byungchul Cho
    • Progress in Medical Physics
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Purpose: Although ionization chambers are widely used to measure beam commissioning data, point-by-point measurements of all the profiles with various field size and depths are time-consuming tasks. As an alternative, we investigated the feasibility of a linear diode array for commissioning a treatment planning system. Methods: The beam data of a Varian TrueBeam® radiotherapy system at 6 and 10 MV with/without a flattening filter were measured for commissioning of an Eclipse Analytical Anisotropic Algorithm (AAA) ver.15.6. All of the necessary beam data were measured using an IBA CC13 ionization chamber and validated against Varian "Golden Beam" data. After validation, the measured CC13 profiles were used for commissioning the Eclipse AAA (AAACC13). In addition, an IBA LDA-99SC linear diode array detector was used to measure all of the beam profiles and for commissioning a separate model (AAALDA99). Finally, the AAACC13 and AAALDA99 dose calculations for each of the 10 clinical plans were compared. Results: The agreement of the CC13 profiles with the Varian Golden Beam data was confirmed within 1% except in the penumbral region, where ≤2% of a discrepancy related to machine-specific jaw calibration was observed. Since the volume was larger for the CC13 chamber than for the LDA-99SC chamber, the penumbra widths were larger in the CC13 profiles, resulting in ≤5% differences. However, after beam modeling, the penumbral widths agreed within 0.1 mm. Finally the AAALDA99 and AAACC13 dose distributions agreed within 1% for all voxels inside the body for the 10 clinical plans. Conclusions: In conclusion, the LDA-99SC diode array detector was found to be accurate and efficient for measuring photon beam profiles to commission treatment planning systems.

A Study on Signal Sub Spatial Method for Removing Noise and Interference of Mobile Target (이동 물체의 잡음과 간섭제거를 위한 신호 부 공간기법에 대한 연구)

  • Lee, Min-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.3
    • /
    • pp.224-228
    • /
    • 2015
  • In this paper, we study the method for desired signals estimation that array antennas are received signals. We apply sub spatial method of direction of arrival algorithm and adaptive array antennas in order to remove interference and noise signal of received antenna signals. Array response vector of adaptive array antenna is probability, it is correctly estimation of direction of arrival of targets to update weight signal. Desired signals are estimated updating covariance matrix after moving interference and noise signals among received signals. We estimate signals using eigen decomposition and eigen value, high resolution direction of arrival estimation algorithm is devided signal sub spatial and noise sub spatial. Though simulation, we analyze to compare proposed method with general method.

TRACE EXPRESSION OF r-TH ROOT OVER FINITE FIELD

  • Cho, Gook Hwa;Koo, Namhun;Kwon, Soonhak
    • Journal of the Korean Mathematical Society
    • /
    • v.57 no.4
    • /
    • pp.1019-1030
    • /
    • 2020
  • Efficient computation of r-th root in 𝔽q has many applications in computational number theory and many other related areas. We present a new r-th root formula which generalizes Müller's result on square root, and which provides a possible improvement of the Cipolla-Lehmer type algorithms for general case. More precisely, for given r-th power c ∈ 𝔽q, we show that there exists α ∈ 𝔽qr such that $$Tr{\left(\begin{array}{cccc}{{\alpha}^{{\frac{({\sum}_{i=0}^{r-1}\;q^i)-r}{r^2}}}\atop{\text{ }}}\end{array}\right)}^r=c,$$ where $Tr({\alpha})={\alpha}+{\alpha}^q+{\alpha}^{q^2}+{\cdots}+{\alpha}^{q^{r-1}}$ and α is a root of certain irreducible polynomial of degree r over 𝔽q.

A Study on Efficient Configuration of Array for Phased Aray Antenna with Hybrid Phased Shifting Device (복합 위상천이기 구성을 갖는 위상배열안테나의 효율적인 배열구성에 관한 연구)

  • Jung, Jin-Woo;Park, Sung-Il;An, Hyung-Soon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1199-1206
    • /
    • 2018
  • The hybrid phase shifting device is consist of general phase shifter in sub-array and the true time delay inter sub-array. This configuration for phased shifting can efficiently improve the beam squint according to frequencies. However, when an appropriate array configuration is not selected, a gain variation of main lobe for a phased array antenna is occurred. In order to solve these problems, a simplified formula for constructing efficient array based on the system design requirements, such as the fractional bandwidth, the maximum beam steering angle, and limit criterion of the gain variation, was presented.

Optimization of DL-EPR Test Solution for Duplex Stainless Steel S31083 Using Taguchi Design (다구찌 설계를 이용한 듀플렉스 스테인리스강 S31083용 DL-EPR 시험용액의 최적화)

  • Jung, Kwang-Hu;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.77-84
    • /
    • 2021
  • This study aims to optimize the DL-EPR test solution for duplex stainless steel S31083 using the Taguchi design. The test solution parameters applied to the Taguchi design are H2SO4, NaCl, KSCN concentration, and temperature. In the experimental design, an orthogonal array of 4 levels 4 factor L16(44) was used. Output values for the orthogonal array were used for resolution (degree of sensitization) and selective etch (Ia) values. The optimal test solution conditions were selected by comparing the normalized S/N ratio for the two reaction properties. As a result, the H2SO4 and NaCl were identified as the main factors influencing the sensitivity measurement, but the delta statistics showed that the KSCN concentration and temperature had relatively low influence. The optimal condition was identified as 1.5 M H2SO4+0.03 M KSCN+1.5M NaCl at 30 ℃. The degree of sensitization presented a tendency to depend on the heat treatment temperature and time in the optimal test solution. This investigation confirmed the possibility of optimizing the experiment solution for the DL-EPR test of stainless steel using the Taguchi technique.

Sweeping Linearization of Wavelength Swept Laser using PID Control (PID 제어를 이용한 파장 스위핑 레이저의 스위핑 선형화)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.412-419
    • /
    • 2020
  • In this study, a PID control method for sweeping automatic linearization of a wavelength swept laser is proposed. First, the closedloop transfer function embodying the PID control is derived. Through the simulation of the function, Kp = 0.022, Ki = 0.008, Kd = 0.002 were obtained as the best PID coefficients for fast linear sweeping. The performance test using the PID coefficients showed that linear sweeping was held up well with a 98.7% decrement in nonlinearity after the 10th feedback, and 45 nm sweeping range, 1 kHz sweeping frequency, and 8.8 mW average optical power were obtained. The equipment consists of a fiber Bragg grating array, an optical-electronic conversion circuit, and a LabVIEW FPGA program. Every 5s, automatic feedback and PID control generate a new compensated waveform and produce a better linear sweeping than before. Compared with nonlinear sweeping, linear sweeping can reduce the cumbersome and time-consuming recalibration processes and produce more accurate measurement results.

Microstrip 8$\times$2 circularly polarized phased array antenna (마이크로스트립 원형 편파 8$\times$2 위상 배열 안테나)

  • 윤재승;이영주;박위상
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.345-349
    • /
    • 2000
  • A microstrip polarized 8${\times}$2 linear phased array antenna with four 4-bit phase shifters is designed at 10 GHz. The 180$^{\circ}$and 90$^{\circ}$ sections of the phase shifter are of the switched line type, and the rests are of the loaded line type. A 2${\times}$2 sequential sub-array is adopted for a broad axial ratio bandwidth. The construction of the array antenna is of the tile type placing the phase shifters on the same layer containing the feed network. The element spacing is chosen to be 0.45λ$\sub$0/ to exclude the grating lobe. Measurement results show a gain 9.69 dB at broadside and 8.3 dB at the beam-tilt angle of 16$^{\circ}$ by imposing a progressive phase of 90$^{\circ}$.

  • PDF

A Desired Signal Estimation using Sub-Array Algorithm of Adaptive Array Antenna in Correlation Channel Environment (상관성 채널 환경에서의 적응배열안테나의 부배열 알고리즘을 이용한 관심신호 추정)

  • Lee, Kwanhyeong;Cho, Taejun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.3
    • /
    • pp.75-81
    • /
    • 2017
  • This paper estimate a desired signal in a correlation wireless communication. The transmitted signal is mixed with the information signal, interference, and noise in wireless channel, and it is incident on the receiver. In this paper, we apply MUSIC algorithm and sub-array method to recover the total rank of the correlation matrix in order to estimation a desired signal among receiving signals. Through simulation, we analyze to compare the proposed method with the classical MUSIC algorithm. As a result of the simulation, the proposed method improved the resolution about 10degrees compared to the conventional MUSIC algorithm. We prove the superiority of the proposed method for the desired signal estimation in correlation channel.