• 제목/요약/키워드: Sub- resonance

검색결과 522건 처리시간 0.024초

Development of TEM Head-Size Resonator for 3T MRI Head Coil

  • Ha, Seung-Hoon;Choe, Bo-Young;Lee, Hyoung-Koo-;Suh, Tae-Suk;Shinn, Kyung-Sub;Kim, Yong-Sik;Lee, Heung-Kyu
    • 한국자기공명학회:학술대회논문집
    • /
    • 한국자기공명학회 2000년도 동계총회 및 제16회 자기공명 학술발표회
    • /
    • pp.35-37
    • /
    • 2000
  • PDF

B2O3 가 첨가된 (Zn0.8Mg0.2)TiO3 마이크로파 유전체 세라믹스의 저온소결 (Low Temperature Sintering of B2O3 -added (Zn0.8Mg0.2)TiO3 Microwave Dielectric Ceramics)

  • 방재철
    • 한국전기전자재료학회논문지
    • /
    • 제19권1호
    • /
    • pp.29-34
    • /
    • 2006
  • The effects of $B_2O_3$ addition on the low-temperature sintering behavior and microwave dielectric properties of $(Zn_{0.8}Mg_{0.2})TiO_3$ ceramic system were investigated. Highly dense samples were obtained at the sintering temperatures below $900^{\circ}C$. The $Q{\times}f_o$ values were determined by the microstructures and sintering shrinkages which are affected by the amount of $B_2O_3$ and sintering temperature. Temperature coefficient of resonance frequency($T_f$) changes to a positive value with increasing the amount of $B_2O_3$ due to the increased amount of rutile phase which is one of the reaction products between $(Zn_{0.8}Mg_{0.2})TiO_3$ and $B_2O_3$. For $6.19 moi.{\%}B_2O_3$-added $(Zn_{0.8}Mg_{0.2})TiO_3$ system, it exhibits ${\epsilon}_r$ = 23.5, $Q{\times}f_o$ = 53,000 GHz, and $T_f$ = 0 ppm/$^{\circ}C$ when sintered at $900^{\circ}C$ for 5 h.

Pb[(Mn1/3Sb2/3)0.05Zr0.475]O3세라믹스를 이용한 변형 Ring/Dot형 압전세라믹 변압기의 감압특성 (Voltage Step-down Characteristics of Modified Ring/Dot-type Piezoelectric Transformer using Pb[(Mn1/3Sb2/3)0.05Zr0.475]O3 Ceramics)

  • 남성진;남효덕;손준호;이준형
    • 한국전기전자재료학회논문지
    • /
    • 제17권2호
    • /
    • pp.171-177
    • /
    • 2004
  • Voltage step-down characteristics in Ring/Dot type piezoelectric transformer were examined as a function of the area of input electrode when the area of output electrode is fixed. The effects of driving frequency and load resistance on the voltage step-down characteristics were also examined. Voltage gain was greatly dependent on the driving frequency and load resistance, and showed a maximum gain at resonance frequency of the step-down transformer. The frequency where the maximum cutout voltage appears increased about 0.2% as the load resistance increased from 10 to 150 Ω. As the area of input electrode increased, the voltage gain and the efficiency of the transformer increased. Frequency dependence of efficiency of the step-down transformer revealed a similar tendency with the voltage gain curves. The maximum efficiency remarked 94% when the input voltage and the load resistance were 20 Vpp and 120 Ω, respectively.

Interpretation of Complete Tumor Response on MRI Following Chemoradiotherapy of Rectal Cancer: Inter-Reader Agreement and Associated Factors in Multi-Center Clinical Practice

  • Hae Young Kim;Seung Hyun Cho;Jong Keon Jang;Bohyun Kim;Chul-min Lee;Joon Seok Lim;Sung Kyoung Moon;Soon Nam Oh;Nieun Seo;Seong Ho Park
    • Korean Journal of Radiology
    • /
    • 제25권4호
    • /
    • pp.351-362
    • /
    • 2024
  • Objective: To measure inter-reader agreement and identify associated factors in interpreting complete response (CR) on magnetic resonance imaging (MRI) following chemoradiotherapy (CRT) for rectal cancer. Materials and Methods: This retrospective study involved 10 readers from seven hospitals with experience of 80-10210 cases, and 149 patients who underwent surgery after CRT for rectal cancer. Using MRI-based tumor regression grading (mrTRG) and methods employed in daily practice, the readers independently assessed mrTRG, CR on T2-weighted images (T2WI) denoted as mrCRT2W, and CR on all images including diffusion-weighted images (DWI) denoted as mrCRoverall. The readers described their interpretation patterns and how they utilized DWI. Inter-reader agreement was measured using multi-rater kappa, and associated factors were analyzed using multivariable regression. Correlation between sensitivity and specificity of each reader was analyzed using Spearman coefficient. Results: The mrCRT2W and mrCRoverall rates varied widely among the readers, ranging 18.8%-40.3% and 18.1%-34.9%, respectively. Nine readers used DWI as a supplement sequence, which modified interpretations on T2WI in 2.7% of cases (36/1341 [149 patients × 9 readers]) and mostly (33/36) changed mrCRT2W to non-mrCRoverall. The kappa values for mrTRG, mrCRT2W, and mrCRoverall were 0.56 (95% confidence interval: 0.49, 0.62), 0.55 (0.52, 0.57), and 0.54 (0.51, 0.57), respectively. No use of rectal gel, larger initial tumor size, and higher initial cT stage exhibited significant association with a higher interreader agreement for assessing mrCRoverall (P ≤ 0.042). Strong negative correlations were observed between the sensitivity and specificity of individual readers (coefficient, -0.718 to -0.963; P ≤ 0.019). Conclusion: Inter-reader agreement was moderate for assessing CR on post-CRT MRI. Readers' varying standards on MRI interpretation (i.e., threshold effect), along with the use of rectal gel, initial tumor size, and initial cT stage, were significant factors associated with inter-reader agreement.

Physicochemical Characterization and NMR Assignments of Ginsenosides Rb1, Rb2, Rc, and Rd Isolated from Panax ginseng

  • Cho, Jin-Gyeong;Lee, Min-Kyung;Lee, Jae-Woong;Park, Hee-Jung;Lee, Dae-Young;Lee, Youn-Hyung;Yang, Deok-Chun;Baek, Nam-In
    • Journal of Ginseng Research
    • /
    • 제34권2호
    • /
    • pp.113-121
    • /
    • 2010
  • The fresh ginseng roots were extracted with aqueous methanol, and the obtained extracts were partitioned using ethyl acetate, n-butanol, and water, successively. The repeated silica gel and octadecyl silica gel column chromatogaraphy for n-butanol fraction afforded four diol ginseng saponins, ginsenosides $Rb_1$, $Rb_2$, $R_c$, and Rd. The physicochemical, spectroscopic, and chromatographic characteristics of these ginsenosides were measured and compared with those reported in the literature. Some of the peak assignments in previously published $^1H$- and $^{13}C$-nuclear magnetic resonance (NMR) spectra were inaccurate. This study employed two-dimensional NMR experiments, including $^1H-^1H$ correlation spectroscopy, heteronuclear single quantum correlation, and heteronuclear multiple bond connectivity, to determine exact peak assignments.

Monitoring Posterior Cerebral Perfusion Changes With Dynamic Susceptibility Contrast-Enhanced Perfusion MRI After Anterior Revascularization Surgery in Pediatric Moyamoya Disease

  • Yun Seok Seo;Seunghyun Lee;Young Hun Choi;Yeon Jin Cho;Seul Bi Lee;Jung-Eun Cheon
    • Korean Journal of Radiology
    • /
    • 제24권8호
    • /
    • pp.784-794
    • /
    • 2023
  • Objective: To determine whether dynamic susceptibility contrast-enhanced (DSC) perfusion magnetic resonance imaging (MRI) can be used to evaluate posterior cerebral circulation in pediatric patients with moyamoya disease (MMD) who underwent anterior revascularization. Materials and Methods: This study retrospectively included 73 patients with MMD who underwent DSC perfusion MRI (age, 12.2 ± 6.1 years) between January 2016 and December 2020, owing to recent-onset clinical symptoms during the follow-up period after completion of anterior revascularization. DSC perfusion images were analyzed using a dedicated software package (NordicICE; Nordic NeuroLab) for the middle cerebral artery (MCA), posterior cerebral artery (PCA), and posterior border zone between the two regions (PCA-MCA). Patients were divided into two groups; the PCA stenosis group included 30 patients with newly confirmed PCA involvement, while the no PCA stenosis group included 43 patients without PCA involvement. The relationship between DSC perfusion parameters and PCA stenosis, as well as the performance of the parameters in discriminating between groups, were analyzed. Results: In the PCA stenosis group, the mean follow-up duration was 5.3 years after anterior revascularization, and visual disturbances were a common symptom. Normalized cerebral blood volume was increased, and both the normalized time-topeak (nTTP) and mean transit time values were significantly delayed in the PCA stenosis group compared with those in the no PCA stenosis group in the PCA and PCA-MCA border zones. TTPPCA (odds ratio [OR] = 6.745; 95% confidence interval [CI] = 2.665-17.074; P < 0.001) and CBVPCA-MCA (OR = 1.567; 95% CI = 1.021-2.406; P = 0.040) were independently associated with PCA stenosis. TTPPCA showed the highest receiver operating characteristic curve area in discriminating for PCA stenosis (0.895; 95% CI = 0.803-0.986). Conclusion: nTTP can be used to effectively diagnose PCA stenosis. Therefore, DSC perfusion MRI may be a valuable tool for monitoring PCA stenosis in patients with MMD.