• 제목/요약/키워드: Sub System

검색결과 8,105건 처리시간 0.031초

Parametric analysis of hybrid outrigger system under wind and seismic loads

  • Neethu Elizabeth Johna;Kiran Kamath
    • Structural Engineering and Mechanics
    • /
    • 제86권4호
    • /
    • pp.503-518
    • /
    • 2023
  • In tall constructions, the outriggers are regarded as a structural part capable of effectively resisting lateral loads. This study analyses the efficacy of hybrid outrigger system in high rise RCC building for various structural parameters identified. For variations in α, which is defined as the ratio of the relative flexural stiffness of the core to the axial rigidity of the column, static and dynamic analyses of hybrid outrigger system having a virtual and a conventional outrigger at two distinct levels were conducted in the present study. An investigation on the optimal outrigger position was performed by taking the results from absolute maximum inter storey drift ratio (ISDmax), roof acceleration (accroof), roof displacement (disproof), and base bending moment under both wind and seismic loads on analytical models having 40, 60 and 80 storeys. An ideal performance index parameter was introduced and was utilized to obtain the optimal position of the hybrid outrigger system considering the combined response of ISDmax, accroof, disproof and, criteria required for the structure under wind and seismic loads. According to the behavioural study, increasing the column area and outrigger arm length will maximise the performance of the hybrid outrigger system. The analysis results are summarized in a flowchart which provides the optimal positions obtained for each dependent parameter and based on ideal performance index which can be used to make initial suggestions for installing a hybrid outrigger system.

마이크로버블 장치를 이용한 제지공정 소성로 배기 오염물질 처리 (Treatment of Exhaust Pollutants from a Lime Kiln of Paper-mill with Micro-bubble System)

  • 정재억;정용준
    • 한국환경과학회지
    • /
    • 제29권11호
    • /
    • pp.1025-1032
    • /
    • 2020
  • This work was performed to develop a dip injection wet scrubber (DIWS) system with chlorine dioxide as the oxidant. The exhaust pollutants from a lime kiln of paper-mill were introduced to the system. When NaClO3 was used to oxidize NO into NO2, the oxidation was unsatisfactory and the combination of HNO3 or H2SO4 was required for 100% oxidation. ClO2 is recommended to oxidize NO and SO2 effectively. With the combination of 1st stage of DIWS and ClO2, 57.1% of NOx and 98% of SO2 were effectively removed. In the case of 2nd stage of DIWS and ClO2, 93.5% of NOx and 99% of SO2 were removed. The ClO2+DIWS process was superior to the ClO2+Scrubber process in terms of investment, running cost and NOx removal efficiency.

데이터 맵핑기술을 이용한 건축물 LCCO2 평가시스템 개발 (Development of Buildng LCCO2 Assessment System through Data Mapping Technology.)

  • 금원석;태성호;노승준;방준식
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.151-152
    • /
    • 2012
  • Recently, there are growing interests in building LCCO2 Assessment to reduce carbon emissions. However, existing methods of assessment system include inefficiency in the process of CO2 calculation requiring considerable data input. Therefore, the purpose of this study is to develop an efficient building assessment system appropriate to material production in construction stage. To that end, quantity input technology was limited to data mapping. Also quantity calculation based on work breakdown structure and item codes consisted of hierarchical structure that is based on facet classification were analyzed. As a result, connectivity links of quantity calculation and CO2 functional units through item codes for data mapping, and assessment system including calculation and database parts were developed.

  • PDF

다중 회귀 분석을 이용한 친환경 건축물 인증제도가 공동주택 CO2 발생량에 미치는 영향 분석 (Impact of Green Building Rating System on an Apartment Housing CO2 Emission using Multiple Regression Analysis)

  • 정정희;류혁준;이종훈;김주형;김재준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.111-112
    • /
    • 2013
  • Architecture has a large influence in the environment and human health. Therefore eco-friendly concept and sustainable development are important in Architectural field. This study aims to analyze impact of green building rating system on an apartment housing CO2 emission using multiple regression analysis. But in this result, green building rating system has no effect on CO2 emission. So, future study is required to analyze factors of green building rating system on the CO2 emission.

  • PDF

단일 롤 방법으로 제작한 3원계 Al-Cr-Si 급냉리본의 구조 및 열 특성 (Structure and Thermal Properties of a Ternary Al-Cr-Si Quenching Ribbon Manufactured by Single Roll Method)

  • 한창석;김기웅;김우석
    • 한국재료학회지
    • /
    • 제31권5호
    • /
    • pp.296-300
    • /
    • 2021
  • Al-Cr-Si ternary quench ribbons are fabricated using a single roll method and investigated for their structural and thermal properties. In particular, the sinterability is examined by pulse current sintering to obtain the following results. The Al74Cr20Si6 composition becomes a quasicrystalline single phase; by reducing the amount of Cr, it becomes a two-phase mixed structure of Al phase and quasicrystalline phase. As a result of sintering of Al74Cr20Si6, Al77Cr13Si10 and Al90Cr6Si4 compositions, the sintering density is increased with the large amount of Al phase; the sintering density is the highest in Al90Cr6Si4 composition. In addition, as a result of investigating the effects of sintering temperature and pressurization on the sintered density of Al90Cr6Si4, a sintered compact of 99% or more at 513 K and 500 MPa is produced. In particular, since the Al-Cr-Si ternary crystal is more thermally stable than the Al-Cr binary quaternary crystal, it is possible to increase the sintering temperature by about 100 K. Therefore, using an alloy of Al90Cr6Si4 composition, a sintered compact having a sintered density of 99 % or more at 613 K and 250 MPa can be manufactured. It is possible to increase the sintering temperature by using the alloy system as a ternary system. As a result, it is possible to produce a sintered body with higher density than that possible using the binary system, and at half the pressure compared with the conventional Al-Cr binary system.

빙축열조를 이용한 냉매과냉각 시스템 기초연구 (Basic Study on Sub-cooling System using Ice storage tank)

  • 이은지;이동원;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.990-995
    • /
    • 2009
  • Experimental basic study was performed to understand the characteristics of sub-cooled refrigerant using a cold heat storage system. This system was made up general vapor-compression refrigeration cycle added sub-cooler and ice storage tank. The purpose of this study are to application use of cold-heat storage systems multiplicity of fields and to understand of sub-cooling system. At the condition using ice storage system, the ice making process was operated during night time by electric power. And then, the refrigerant was sub-cooled using stored cold-heat after being discharged from the air cooling condenser during the day time. Comparing the result at general operation with the operation using sub-cooling system. This study showed the effects of the sub-cooled degree. The cooling performance was increased owing to the sub-cooling of refrigerant during day time, and the compressor consume power was a little decreased. Thus the COP was also increased owing to the sub-cooling of refrigerant.

  • PDF

UV/TiO2/H2O2 시스템을 이용한 매립지(埋立地) 침출수(浸出水) 처리(處理) (Treatment of Landfill Leachate by UV/TiO2/H2O2 System)

  • 김성준;문정의
    • 상하수도학회지
    • /
    • 제11권4호
    • /
    • pp.133-141
    • /
    • 1997
  • In order to treat the landfill leachate, $UV/TiO_2/H_2O_2$ system connected with biological treatment was investigated, and proper pretreatment methods were examined to reduce the load on the system considering economical and technical efficiency. It was more profitable to put $H_2O_2$ into the system in the early stage for the sample which was treated with $H_2SO_4$ to decrease alkalinity and with $FeCl_3-6H_2O$ flocculation. Because the required reaction time run up by increasing $H_2O_2$ input amount, though the COD was reduced slightly, the optimal $H_2O_2$ input amount should be determined for the desired COD and the economical efficiency. The appropriate way to get the lowest COD in the shortest time was the method to treat the sample which was controlled to pH 3.5 after adjusting to pH 12 and put 500 ppm $H_2O_2$ into the system. In that case, to increase $H_2O_2$ input amount was not profitable for the system efficiency. The sufficient photocatalytic excited time was required to reduce the photocatalytic decomposition time for the sample which was gone through the alkali state.

  • PDF

RF 스퍼터링 시스템을 이용하여 증착한 비정질 Ga2O3 박막의 스퍼터링 파워에 따른 특성 평가 (The Effect of Sputtering Power on Amorphous Ga2O3 Deposited by RF Sputtering System)

  • 김형민;박상빈;김경환;홍정수
    • 한국전기전자재료학회논문지
    • /
    • 제36권5호
    • /
    • pp.488-493
    • /
    • 2023
  • The effect of sputtering power on the amorphous Ga2O3 thin film deposited using the radio frequency sputtering system was evaluated. Amorphous Ga2O3 is cheaper and more efficiently fabricated than crystalline Ga2O3, and is studied in various fields such as RRAM, photodetector, and flexible devices. In this study, amorphous Ga2O3 was deposited by radio frequency sputtering system and represented a transmittance of over 80% in the visible light region and a homogeneous and dense surface. The optical band gap energy decreased as the sputtering power increased owing to the quantum size effect. Thus, the specific band gap of amorphous Ga2O3 can be obtained by adjusting the sputtering power, it indicates amorphous Ga2O3 can be used in various fields.

ON THE DIGITS OF NUMBERS IN THE SYSTEM LOGIC B3

  • HASAN KELES
    • Journal of Applied and Pure Mathematics
    • /
    • 제6권1_2호
    • /
    • pp.97-103
    • /
    • 2024
  • This study is about digits of numbers in system logic B3. Any real number is written as digits in the binary system, in the ternary system. The numbers in base two and base three are also written in the B3 system ternary logic. These two writing methods are transferred into the third method. The real numbers 0,1 and 0, 1, 2 are written as digits. The same real numbers are written as digits of elements of the set -1, 0, 1 in base B3. The periods here are investigated. The relationship between these digits is analysed.