• Title/Summary/Keyword: Studs

검색결과 230건 처리시간 0.023초

강-콘크리트 혼합거더 접합부의 정적 거동에 관한 연구 (A Study on the Static Behavior of Connection for the Steel-Concrete Hybrid Girder)

  • 김문겸;노병철;김정훈;박현철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.426-429
    • /
    • 2006
  • This paper focuses on the static behavior of prestressed and non-prestressed connections for the steel-concrete hybrid girder. Based on the experimental study, it is found that the girder with non-prestressed connection failed by local concrete failure at the connection area, and the studs are taken out from the concrete. In case of the girder with prestressed joint, the failure of the girder is initiated by the crack at the varying section area. The test results show that the girder with prestressed connection has higher load carrying capacity compare to the girder with non-prestressed connection by 12%. Therefore, the application of prestressing at the concrete-steel connection recommended for the more secure connection.

  • PDF

Experimental study on partially concrete-filled steel tubular columns

  • Ishizawa, T.;Nakano, T.;Iura, M.
    • Steel and Composite Structures
    • /
    • 제6권1호
    • /
    • pp.55-69
    • /
    • 2006
  • The results of tests conducted on 11 concrete-filled steel tubular columns were reported. Concrete was partially filled in circular steel tubular columns. The primary test parameters were radius and thickness of steel tubes, concrete height, loading patterns and attachment of diaphragm and studs. Concrete strain was measured directly by embedding strain gauges so that the effect of diaphragm on concrete confinement could be investigated. The effects of concrete height and diaphragm on ultimate strength and ductility of steel tubes were investigated. The comparisons of the test results with the existing results for rectangular cross-sections were made on the basis of ultimate strength and ductility of concrete-filled steel tubular columns.

Behaviour evaluation of shear connection by means of shear-connection strips

  • Rovnak, Marian;Duricova, Antonia
    • Steel and Composite Structures
    • /
    • 제4권3호
    • /
    • pp.247-263
    • /
    • 2004
  • Comparison of behaviour of shear connections by means of shear-connection strips (perfobond and comb-shaped strips) and headed studs under static and repeated loading, possible failure modes of concrete dowels and ways of the quantitative differentiation of some failure modes are described in the paper. The article presents a review of knowledge resulting from the analysis of shear-connection effects based on tests of perfobond and comb-shaped strips carried out in the laboratories of the Faculty of Civil Engineering of the Technical University of Kosice (TU of Kosice) in Slovakia and their comparison with results obtained by other authors.

The Development of a Non-Intrusive Test of Check Valve Using Acoustics and Magnetics

  • Sim, Cheul-Muu;Choi, Ha-Lim;Baik, Heung-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • 제16권1E호
    • /
    • pp.9-14
    • /
    • 1997
  • Check valves used in industrial and Nuclear Power Plant safety systems are susceptible to failure modes generally associated with wear of internal parts. Specifically, hinge pins, disc studs, pistons, and other mechanical parts may degrade over time, and in some cases, may which might produce a disabling event leading to plant or process shutdown. The primary diagnostic technique in the past has been to disassemble the valves. This procedure is costly, time consuming, and in the nuclear industry, it can lead to radiation exposure in some situations. Additionally repair and reassembly of a valve does not ensure proper operation. Non-intrusive diagnostic technologies including acoustics and magnetics with a digital signal analysis allow to evaluate check valve performance without a disassembly and is able to help the user detect degraded valve conditions.

  • PDF

Deterioration in strength of studs based on two-parameter fatigue failure criterion

  • Wang, Bing;Huang, Qiao;Liu, Xiaoling
    • Steel and Composite Structures
    • /
    • 제23권2호
    • /
    • pp.239-250
    • /
    • 2017
  • In the concept of two-parameter fatigue failure criterion, the material fatigue failure is determined by the damage degree and the current stress level. Based on this viewpoint, a residual strength degradation model for stud shear connectors under fatigue loads is proposed in this study. First, existing residual strength degradation models and test data are summarized. Next, three series of 11 push-out specimen tests according to the standard push-out test method in Eurocode-4 are performed: the static strength test, the fatigue endurance test and the residual strength test. By introducing the "two-parameter fatigue failure criterion," a residual strength calculation model after cyclic loading is derived, considering the nonlinear fatigue damage and the current stress condition. The parameters are achieved by fitting the data from this study and some literature data. Finally, through verification using several literature reports, the results show that the model can better describe the strength degradation law of stud connectors.

물/유기용매 불혼합 이성분계에서의 반응염색(Ⅱ) - C. I. Reactive Blue 203을 이용한 견섬유의 염색 - (Reactive Dyeing in Immiscible Two-phase System of Water/Organic Solvent(Ⅱ) - The Dyeing of Silk with C. I. Reactive Blue 203 -)

  • 김태경;김미경;임용진;조광호
    • 한국염색가공학회지
    • /
    • 제13권2호
    • /
    • pp.42-42
    • /
    • 2001
  • Following the prior studs regarding that 1.0g of cotton fabric cound be dyed uniformly with a reactive dye in the solvent mixture of 2㎖ of water and 23㎖ of dichloromethane, silk fabric was dyed with C. I. Reactive Blue 203 in the water/dichloromethane two-phase immiscible solvent media. In order to minimize dye loss due to its hydrolysis, the reactive dyeing was carried out in dichloromethane containing a small amount of water. With only 3㎖ of water in 22㎖ of dichloromethane, 1.0g of silk fabric could be dyed perfectly. The uptake ratio was increased greatly, compared with that of normal reactive dyeing in a water medium. It would seem that the one of hydrophobic solvents, dichloromethane, can assist the even dyeing as it disperses a small amount of dye-dissolved water phase and conveys this water phase to the fabric entirely and uniformly.

호장근 추출액에 의한 염색성(I) (The Dyeing Properties of Polygonum cuspidatum Extract( I ))

  • 김미숙;최석철
    • 한국염색가공학회지
    • /
    • 제13권1호
    • /
    • pp.45-54
    • /
    • 2001
  • The Purpose of this studs was to investigate dyeing properties of silk and nylon fabrics by Polygonum cuspidatum extract. The properties were evaluated by it's extracting condition, dyeing condition, mordants variables, methods of mordanting and color fastness. Silk fabric showed the highest K/S value at $50-70^\circ{C}$, while Nylon fabric showed at $90^\circ{C}$. Surface color of dyed fabrics were various by the used mordants ; none-, and Al-mordanted fabrics were yellow, Cu-mordanted fabrics were redish yellow, Fe-mordanted fabrics were olive green. Fe-mordanted silk fabrics showed excellent laundering fastness and light fastness. Both silk and nylon fabric showed excellent laundering and dry cleaning fastness.

  • PDF

물/유기용매 불혼합 이성분계에서의 반응염색(II) - C. I. Reactive Blue 203을 이용한 견섬유의 염색 - (Reactive Dyeing in Immiscible Two-phase System of Water/Organic Solvent (II) - The Dyeing of Silk with C. I. Reactive Blue 203 -)

  • 김태경;김미경;임용진;조광호
    • 한국염색가공학회지
    • /
    • 제13권2호
    • /
    • pp.128-134
    • /
    • 2001
  • Following the prior studs regarding that 1.0g of cotton fabric round be dyed uniformly with a reactive dye in the solvent mixture of $2m\ell$ of water and $23m\ell$ of dichloromethane, silk fabric was dyed with C. I. Reactive Blue 203 in the water/dichloromethane two-phase immiscible solvent media. In order to minimize dye loss due to its hydrolysis, the reactive dyeing was carried out in dichloromethane containing a small amount of water. With only $3m\ell$ of water in $22m\ell$ of dichloromethane, 1.0g of silk fabric could be dyed perfectly. The uptake ratio was increased greatly, compared wish that of normal reactive dyeing in a water medium. It would seem that the one of hydrophobic solvents, dichloromethane, can assist the Even dyeing as it disperses a small amount of dye-dissolved phase and conveys this water phase to the fabric entirely and uniformly.

  • PDF

19세기 전기의 서양 남성 속옷에 관한 고찰 (Western Men`s Underclothes in The First Half of The 19C)

  • 김주애;허정란
    • 복식문화연구
    • /
    • 제7권5호
    • /
    • pp.56-67
    • /
    • 1999
  • At the turn of the 19C, the first development, spreading to the all classes that peculiar attitude of mind associated with the term prudery. The second changes of habit which affected both sexes and their undergarments were the novel idea of personal cleanliness. Drawers appear to have been of two lengths, short, when worn under breeches, and long when worn under pantaloons and trousers. The dandy wore corsets for beauty. In the early part of the 19C, the differences between day and evening style came to be accentuated. Not only the beau, but the soldier and hunting man were addicted to stays. The high standing collars of the early 1800s became fairly low in the middle of the century. in mid of the 19C, a woolen under-vest was worn next to the skin and studs were an usual fashion. At about 1850 the bottom of the shirt was cut in a curve. For evening dress the elliptic collar was introduced.

  • PDF

Fatigue experiment of stud welded on steel plate for a new bridge deck system

  • Ahn, Jin-Hee;Kim, Sang-Hyo;Jeong, Youn-Ju
    • Steel and Composite Structures
    • /
    • 제7권5호
    • /
    • pp.391-404
    • /
    • 2007
  • This paper presents push-out tests of stud shear connectors to examine their fatigue behavior for developing a new composite bridge deck system. The fifteen push-out specimens of D16 mm stud welded on 9 mm steel plate were fabricated according to Eurocode-4, and a series of fatigue endurance test and residual strength test were performed. Additionally, the stiffness and strength variations by cyclic loading were compared. The push-out test, when the stiffness reduction ratio of the specimens was 0.95 under cyclic load, resulted in the failure of the studs. The stiffness variation of the push-out specimens additionally showed that the application of cyclic loads reduced the residual strength. The fatigue strength of the shear connectors were compared with the design values specified in the Eurocode-4, ASSHTO LRFD and JSSC codes. The comparison result showed that the fatigue endurance of the specimens satisfies the design values of these codes.