• 제목/요약/키워드: Studs

검색결과 230건 처리시간 0.02초

축구화 스터드의 형태변화에 따른 회전마찰력 (Rotational Friction of Different Soccer Stud)

  • 이중숙;박상균
    • 한국운동역학회지
    • /
    • 제14권2호
    • /
    • pp.121-138
    • /
    • 2004
  • The design of soccer studs is important for providing friction on a variety of surfaces. We hypothesized that a certain type of soccer studs could improve performance due to high rotational friction. Thus, this study was conducted to determine the relationship between the frictional characteristics and different soccer stud design. Twelve recreational soccer players were recruited. Rotational friction data from the force plate was collected for all subjects during normal walking with 180 degree rotation. Walking speed was controlled at 1.2m/s (${\pm}\;0.1\;m/s$) with timing lights on infilled artificial turf. Three different types of soccer studs and one running shoe were tested. Repeated measures ANOVA was used to determine significance. Significant differences were found in rotational friction with four different shoes. Trx and World studs tended to have greater maximum rotational friction than the running shoe (Nova) and traditional soccer shoe(Copa Mondial). The results were as follow : world(25.95Nm) > trx(25.74Nm) > copa(22.50Nm) > nova(16.36Nm). The difference may be due to the number, location, size, and shape of studs. We concluded that stud design influences rotational friction between the shoe and surface during movement. Based on studs design and contact area, Trx with blade type studs are recommended since it showed high rotational friction for performance as well as enough contact area for stability. However, differences due to the mechanical properties of soccer studs are still being investigated.

Analytical performance evaluation of modified inclined studs for steel plate concrete wall subjected to cyclic loads

  • Lim, Jin-Sun;Jeong, Young-Do;Nam, Jin-Won;Kim, Chun-Ho;Yi, Seong-Tae
    • Computers and Concrete
    • /
    • 제17권2호
    • /
    • pp.227-240
    • /
    • 2016
  • An analytical study was conducted to investigate the effect of the shape and spacing of modified inclined studs used as shear connector between concrete and steel plate on the cyclic behavior of steel plate concrete (SC) shear wall. 9 different analysis cases were adopted to determine the optimized shape and spacing of stud. As the results, the skeleton curves were obtained from the load-displacement hysteresis curves, and the ultimate and yielding strengths were increased as the spacing of studs decrease. In addition, the strength of inclined studs is shown to be bigger compared to that of conventional studs. The damping ratios increased as the decrease of stiffness ratio. Finally, with decreasing the spacing distance of studs, the cumulative dissipated energy was increased and the seismic performance was improved.

Effect of local small diameter stud connectors on behavior of partially encased composite beams

  • Nguyen, Giang Bergerova;Machacek, Josef
    • Steel and Composite Structures
    • /
    • 제20권2호
    • /
    • pp.251-266
    • /
    • 2016
  • The paper combines two distinct parts. First the behavior of welded headed studs with small diameters of 10 and 13 mm acting as shear connectors (which are not embraced in current standards) is studied. Based on standard push tests the load-slip relationships and strengths are evaluated. While the current standard (Eurocode 4 and AISC) formulas used for such studs give reasonable but too conservative strengths, less conservative and full load-slip rigidities are evaluated and recommended for a subsequent investigation or design. In the second part of the paper the partially encased beams under bending are analyzed. Following former experiments showing rather indistinct role of studs used for shear connection in such beams their role is studied. Numerical model employing ANSYS software is presented and validated using former experimental data. Subsequent parametric studies investigate the longitudinal shear between steel and concrete parts of the beams with respect to friction at the steel and concrete interface and contribution of studs with small diameters required predominantly for assembly stages (concreting). Substantial influence of the friction and effect of concrete confinement was observed with rather less noticeable contribution of the studs. Distribution of the longitudinal shear and its sharing between friction and studs is presented with concluding remarks.

FE validation of the equivalent diameter calculation model for grouped headed studs

  • Spremic, Milan;Pavlovic, Marko;Markovic, Zlatko;Veljkovic, Milan;Budjevac, Dragan
    • Steel and Composite Structures
    • /
    • 제26권3호
    • /
    • pp.375-386
    • /
    • 2018
  • Existing design codes for steel-concrete composite structures give only general information about the shear connection provided by headed studs in group arrangement. Grouting of the openings in prefabricated concrete slabs, where the grouped headed studs are placed in the deck pockets is alternative to cast-in-place decks to accomplish fast execution of composite structures. This paper considers the possibility to reduce the distance between the studs within the group, bellow the Eurocode limitations. This may lead to increased competitiveness of the prefabricated construction because more studs are placed in the group if negative effectives of smaller distances between studs are limited. The main purpose of this work is to investigate these limits and propose an analytical calculation model for prediction of the shear resistance of grouped stud arrangements in the deck pockets. An advanced FEA model, validated by results of push-out experiments, is used to analyze the shear behavior of the grouped stud with smaller distance between them than recommended by EN 1994-1. Calculation model for shear resistance, which is consistent with the existing Eurocode rules, is proposed based on a newly introduced equivalent diameter of the stud group, $d_G$. The new calculation model is validated by comparison to the results of FE parametric study. The distance between the studs in the longitudinal direction and the number of stud rows and columns in the group are considered as the main variables.

전단스터드의 변형특성에 관한 유한요소해석 -고강도 콘크리트를 사용한 합성보- (Finite Element Analysis of Deformation Characteristics of the Shear Studs embedded in High Strength Concrete Slab of the Composite Beam)

  • 신현섭
    • 한국강구조학회 논문집
    • /
    • 제19권5호
    • /
    • pp.473-482
    • /
    • 2007
  • 합성보가 구조적으로 안전하게 거동하고, 합성단면이 고유의 극한모멘트를 발휘하기 위해서는 전단연결재의 강도뿐만아니라 연성적 거동이 전제조건으로 작용한다. 본 연구에서는 고강도 콘크리트가 사용된 합성보에서 하중형태, 합성율 및 전단스터드의 배치를 달리 하였을 때 일반강도 콘크리트가 사용된 경우에 비해 비교적 적은 스터드의 변형능력이 구조거동 및 설계조건에 미치는 영향을 유한요소해석을 통해 분석하여 보았다. 해석결과에 따르면 고강도 콘크리트를 사용한 합성보의 부분합성 설계에서는 스터드 자체의 강도와 상대변위로 평가되어지는 변형능력이 함께 고려되어야 한다. 특히, 스터드가 등간격으로 배치된 합성보에 등분포 또는 유사 형태의 하중이 작용할 경우 스터드의 변형능력이 합성설계에 대한 제약조건으로 작용하며 이러한 경우 스터드는 외부하중에 대한 전단력의 분포를 고려하여 배치되어야 한다.

Fatigue behavior of stud shear connectors in steel and recycled tyre rubber-filled concrete composite beams

  • Han, Qing-Hua;Wang, Yi-Hong;Xu, Jie;Xing, Ying
    • Steel and Composite Structures
    • /
    • 제22권2호
    • /
    • pp.353-368
    • /
    • 2016
  • This paper extends our recent work on the fatigue behavior of stud shear connectors in steel and recycled tyre rubber-filled concrete (RRFC) composite beams. A series of 16 fatigue push-out tests were conducted using a hydraulic servo testing machine. Three different recycled tyre rubber contents of concrete, 0%, 5% and 10%, were adopted as main variable parameters. Stress amplitudes and the diameters of studs were also taken into consideration in the tests. The results show that the fatigue lives of studs in 5% and 10% RRFC were 1.6 and 2.0 times greater of those in normal concrete, respectively. At the same time, the ultimate residual slips' values of stud increased in RRFC to highlight its better ductility. The average ultimate residual slip value of the studs was found to be equal to a quarter of studs' diameter. It had also been proved that stress amplitude was inversely proportional to the fatigue life of studs. Moreover, the fatigue lives of studs with large diameter were slightly shorter than those of smaller ones and using larger ones had the risk of tearing off the base metal. Finally, the comparison between test results and three national codes was discussed.

스터드 및 타이바를 가진 강판콘크리트 벽체의 표면강판 좌굴강도 평가 (Evaluation of Buckling Strength of Surface Plates in Steel-Plate Concrete Walls with Studs and Tie-bars)

  • 구지모;이경구;김원기;이종보
    • 한국강구조학회 논문집
    • /
    • 제28권3호
    • /
    • pp.129-138
    • /
    • 2016
  • 압축력을 받는 강판 콘크리트(SC) 벽체에서 표면강판의 좌굴은 중요한 한계상태이다. 표면강판은 스터드 또는 타이바 연결재를 통해 콘크리트에 정착된다. 이 논문에서는 실험을 통해 스터드와 타이바가 표면강판좌굴에 미치는 효과를 평가하였다. 실험체는 세 종류의 연결재를 대상으로 하였다; 모두 스터드인 경우, 모두 타이바인 경우, 스터드와 타이바가 교대 설치된 경우이다. 또한 스터드/타이바 간격 대 표면강판 두께비(세장비)를 달리하여 실험을 수행하였다. 실험결과, 스터드와 타이바가 조합된 SC벽체의 표면강판 좌굴형상 및 좌굴강도가 모두 스터드 또는 타이바가 설치된 SC벽체와 잘 일치하였다.

복부에 슬릿이 있는 박판냉간성형형강 스터드의 압축강도 (The Compressive Strength of Thin-Walled Cold-Formed Steel Studs with Slits in the Web)

  • 권영봉;서응규;임덕만;김갑득;권인규
    • 한국강구조학회 논문집
    • /
    • 제24권2호
    • /
    • pp.189-197
    • /
    • 2012
  • 벽식 스틸하우스 벽체의 구조재로 적용되어 오고 있는 박판냉간성형형강 스터드의 경우 열교현상에 의한 단열상의 문제를 가지고 있기 때문에 추가적인 단열재의 사용이 요구된다. 이러한 단열 문제를 해결하기 위하여 웨브에 슬릿이 배치된 냉간성형강 단열스터드가 개발되었다. 그러나 슬릿의 배치로 인하여 단면강도 산정은 대단히 어려운 문제점이 되고 있다. 본 논문에는 단열스터드의 압축강도 및 구조적인 거동에 대한 실험 및 해석적인 연구결과를 기술하였다. 슬릿의 길이, 간격 및 배열형태를 달리하는 세 종류의 단열스터드에 대한 압축실험을 단면의 파괴 시까지 수행하였으며, 실험 및 해석결과에 근거하여 복부에 슬릿이 있는 냉간성형강 스터드에 적용하기 위한 단순한 형태의 강도 산정방법을 제안하였다. 제안된 강도산정법에서는 단열스터드를 등가두께의 슬릿이 없는 일반스터드로 대치하고, 이 등가단면에 직접강도법을 적용하여 단열스터드의 공칭압축강도를 산출한다. 제안된 강도산정방법은 단열스터드 실험결과와 비교하여 검증하였다.

Experimental and numerical study on shear studs connecting steel girder and precast concrete deck

  • Xia, Ye;Chen, Limu;Ma, Haiying;Su, Dan
    • Structural Engineering and Mechanics
    • /
    • 제71권4호
    • /
    • pp.433-444
    • /
    • 2019
  • Shear studs are often used to connect steel girders and concrete deck to form a composite bridge system. The application of precast concrete deck to steel-concrete composite bridges can improve the strength of decks and reduce the shrinkage and creep effect on the long-term behavior of structures. How to ensure the connection between steel girders and concrete deck directly influences the composite behavior between steel girder and precast concrete deck as well as the behavior of the structure system. Compared with traditional multi-I girder systems, a twin-I girder composite bridge system is more simplified but may lead to additional requirements on the shear studs connecting steel girders and decks due to the larger girder spacing. Up to date, only very limited quantity of researches has been conducted regarding the behavior of shear studs on twin-I girder bridge systems. One convenient way for steel composite bridge system is to cast concrete deck in place with shear studs uniformly-distributed along the span direction. For steel composite bridge system using precast concrete deck, voids are included in the precast concrete deck segments, and they are casted with cast-in-place concrete after the concrete segments are erected. In this paper, several sets of push-out tests are conducted, which are used to investigate the heavier of shear studs within the voids in the precast concrete deck. The test data are analyzed and compared with those from finite element models. A simplified shear stud model is proposed using a beam element instead of solid elements. It is used in the finite element model analyses of the twin-I girder composite bridge system to relieve the computational efforts of the shear studs. Additionally, a parametric study is developed to find the effects of void size, void spacing, and shear stud diameter and spacing. Finally, the recommendations are given for the design of precast deck using void for twin I-girder bridge systems.

Compression tests of cold-formed channel sections with perforations in the web

  • Kwon, Young Bong;Kim, Gap Deuk;Kwon, In Kyu
    • Steel and Composite Structures
    • /
    • 제16권6호
    • /
    • pp.657-679
    • /
    • 2014
  • This paper describes a series of compression tests performed on cold-formed steel channel sections with perforations in the web (thermal studs) fabricated from a galvanized steel plate whose thickness ranged from 1.0 mm to 1.6 mm and nominal yield stress was 295 MPa. The structural behavior and performance of thermal studs undergoing local, distortional, or flexural-torsional buckling were investigated experimentally and analytically. The compression tests indicate that the slits in the web had significant negative effects on the buckling and ultimate strength of thin-walled channel section columns. The compressive strength of perforated thermal studs was estimated using equivalent solid channel sections of reduced thickness instead of the studs. The direct strength method, a newly developed and adopted alternative to the effective width method for designing cold-formed steel sections in the AISI Standard S100 (2004) and AS/NZS 4600 (Standard Australia 2005), was calibrated to the test results for its application to cold-formed channel sections with slits in the web. The results verify that the DSM can predict the ultimate strength of channel section columns with slits in the web by substituting equivalent solid sections of reduced thickness for them.