• Title/Summary/Keyword: Strut-Tie

Search Result 204, Processing Time 0.016 seconds

SPMTool: A computer application for analysis of reinforced concrete structures by the Stringer-Panel Method - Validation of nonlinear models

  • Andre Felipe Aparecido de Mello;Leandro Mouta Trautwein;Luiz Carlos de Almeida;Rafael Alves de Souza
    • Computers and Concrete
    • /
    • v.34 no.1
    • /
    • pp.1-14
    • /
    • 2024
  • The design of disturbed regions in reinforced concrete structures usually applies the well known Strut and Tie Method (STM). As an alternative, the Stringer-Panel Method (SPM), an intermediate model between STM and the Finite Element Method (FEM), consists in dividing a structure into two distinct elements: the stringers (which carry axial forces) and panels (which carry shear forces). SPM has already showed good applicability in manual calculations and computer implementations, and its most known application was SPanCAD, an AutoCAD plugin for linear and nonlinear analysis by SPM. Unfortunately, SPanCAD was discontinued by the developers, and it's not compatible with the most recent versions of AutoCAD. So, this paper aims to present a computer program that was developed as an upgrade to the latter: the Stringer Panel Modelling Tool (SPMTool), which is intended to be an auxiliary design tool and it presents improvements, in comparison to SPanCAD. It is possible to execute linear and nonlinear analysis by three distinct formulations: Modified Compression Field Theory (MCFT), Disturbed Stress Field Model (DSFM) and Softened Membrane Model (SMM). The nonlinear results were compared to experimental data of reinforced concrete elements that were not designed by SPM; these elements were also analyzed in SPanCAD. On overall, SPMTool made more realistic predictions to the behavior of the analyzed structures than SPanCAD. Except for DSFM predictions for corbels (1.24), in overall average, the ultimate load predictions were conservative (0.85 to 0.98), which is a good aspect for a design tool. On the other hand, the cracking load predictions presented overestimations (1.06 to 1.47) and higher variations (25.59% to 34.25%) and the post-cracking behavior could not be accurately predicted; for this use case, a more robust finite element software is recommended.

Shear Behavior of High-Strength Concrete Deep Beams and Comparisons with ACI Shear Design Provisions (고강도 철근콘크리트 깊은 보의 전단거동 및 ACI 전단설계 기준과의 비교)

  • 정헌수;양근혁;함영삼
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.874-882
    • /
    • 2002
  • Currently, deep beams are designed according to ACT 318-99 equations derived from experimental data for slender beams with normal-strength concrete. In addition, there is relatively limited information on high-strength concrete deep beams with shear reinforcement. The purpose of this experimental study is to investigate the shear behavior of high-strength concrete deep beams and to grasp the conservatism of ACI shear design provisions. Experimental results on the shear behavior of 22 deep beams under two equal symmetrically placed point loads are reported. compressive strength of concrete cylinder was 800kgf/$\textrm{cm}^2$, and main variables were vertical and horizontal shear reinforcement and shear span-to-overall depth ratio (а/h). Test results showed that for high-strength concrete deep beams with shear span-to-overall depth ratio exceeding 0.75, the vertical shear reinforcement more effectively resisted the shear load than horizontal shear reinforcement. In high-strength concrete deep beams, ACI shear design provisions tended to underestimate the effect of strut-tie action and vertical shear reinforcement and overestimate the ones of horizontal shear reinforcement. Based on the experimental results of high-strength concrete deep beams and shear friction theory, this study modified the equations on the shear capacity specified by the ACI provisions.

Estimation of Shear Strength Along Concrete Construction Joints Considering the Variation of Concrete Cohesion and Coefficient of Friction (콘크리트 시공줄눈 면에서 점착력 및 마찰계수의 변화를 고려한 전단내력 평가)

  • Yang, Keun-Hyeok;Kwon, Hyuck-Jin;Park, Jong-Beom
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.106-112
    • /
    • 2017
  • This paper presents a mathematical model derived from the upper-bound theorem of concrete plasticity to rationally evaluate the shear friction strength of concrete interfaces with a construction joint. The upper limit of the shear friction strength was formulated from the limit state of concrete crushing failure on the strut-and-tie action along the construction joints to avoid overestimating the shear transfer capacity of a transverse reinforcement with a high clamping force. The present model approach proposed that the cohesion and coefficient of friction of concrete can be set to be $0.27(f_{ck})^{0.65}$ and 0.95, respectively, for rough construction joints and $0.11(f_{ck})^{0.65}$ and 0.64, respectively, for smooth ones, where $f_{ck}$ is the compressive strength of concrete. From the comparisons with 155 data compiled from the available literature, the proposed model gave lower values of standard deviation and coefficient of variation of the ratios between predictions and experiments than AASHTO and fib 2010 equations, indicating that the proposed model has consistent trends with test results, unlike the significant underestimation results of such code equations in evaluating the shear friction strength.

Applicability of Partial Post-Tension Method for Deflection Control of Reinforced Concrete Slabs (RC슬래브의 처짐제어를 위한 상향긴장식 부분PT공법의 적용)

  • Lee, Deuck-Hang;Kim, Kang-Su;Kim, Sang-Sik;Kim, Yong-Nam;Lim, Joo-Hyuk
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.347-358
    • /
    • 2009
  • Recently, it is getting into a good situation for the flat-plate slab system to be applied. The flat-plate slab without beam, however, is often too weak to control deflection properly compared to other typical slab-beam structures, for which the post-tension method is generally regarded as one of best solutions. The post-tension (PT) method can effectively control deflection without increase of slab thickness. Despite this good advantage, however, the application of PT method has been very limited due to cost increase, technical problems, and lack of experiences. Therefore, in order to reduce difficulties on applying full PT method under the current domestic circumstances and to enhance constructability of PT system, this research proposed the partial PT method with top jacking anchorage applied in a part of span as need. For the top jacking anchorage system, the efficiency of deflection control shall be considered in detail because it can vary widely depending on the location of anchorage that can be placed anywhere as need, and tensile stresses induced at back of the anchorage zone also shall be examined. Therefore, in this study, analysis were performed on the efficiency of deflection control depending on the location of anchorage and on tensile stresses or forces using finite element method and strut and tie model in the proposed top jacking anchorage system. The proposed jacking system were also applied to the floor slabs at a construction site to investigate its applicability and the analysis results of slab behavior were compared to the measured values obtained from the PT slab constructed by the partial PT method. The result of this study indicates that the partial PT method can be very efficiently applied with little cost increase to control deflection and tensile stresses in the region as a need basis where problem exists.