• 제목/요약/키워드: Structural reinforcement

검색결과 1,708건 처리시간 0.029초

케이블 돔 구조물의 불안정 현상에 대한 브레이싱 보강 효과 (Effects by Bracing Reinforcement on the Instability Phenomenon of Cable Domes)

  • 김승덕;김형석;백인성
    • 한국공간구조학회논문집
    • /
    • 제1권2호
    • /
    • pp.75-83
    • /
    • 2001
  • The characteristics of structural behavior for a cable dome shows a strong nonlinearity and very sensitive by the initial imperfection. The instability phenomenon of Geiger-type cable dome structure is generated due to the in-plane twisting near the critical load level. In this study, therefore, the effect of bracing reinforcement resisting to the in-plane twisting is investigated for the Geiger-type model reinforced by bracing. The effect of initial imperfection is also studied because the structural instability phenomenon of shell-like structure is very sensitive according to the initial condition.

  • PDF

인장력을 받는 RC 부재와 철골 부재 접합부의 유한요소해석 (Finite Element Analysis of Connections between RC and Steel Member under Tensile Loading)

  • 김은주;김승훈;서수연;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.75-82
    • /
    • 2001
  • Finite element analysis using ANSYS program conducted to evaluate the tensile behavior of the connection between reinforced concrete and steel members is presented in this paper. It is assumed that there is a complete bond between head part of the stud and concrete. However, the surface of the column area of stud is separated from the concrete to stop the stress transmission between those. In case of using reinforcement connectors such as C or U type, the interface between concrete and reinforcement is idealized to have strong adhesion. Four concrete-steel specimens which are connected by stud connector or reinforcement connectors are compared and analyzed From the comparison, it was shown that the connection between concrete and steel could be predicted by using the modeling technique used in this paper.

  • PDF

탄소섬유쉬트로 보강한 R/C보의 전단거동에 관한 연구 (A Study on the Shear Behavior of Strengthened R/C Beams with CFS)

  • 신성우;반병렬;이광수;조인철;남정희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권3호
    • /
    • pp.205-211
    • /
    • 1998
  • The purpose of this study is to evaluate shear strengthening effects of R/C beams with carbon fiber sheets. The major variables are shear reinforcement ratios, CFS strengthening ratios and strengthening methods of CFS. Following conclusions can be extracted. The shear capacity of beam strengthened with CFS is about 32~87% higher than that of beams without shear reinforcement. The strengthening effects of patch type is larger than those of strip type. The strain distribution in CFS intersected with shear crack is similar to that in stirrup and larger strain is observed in the middle of the shear span. It can be estimated that shear strength reduction factor ${\alpha}$=0.3 is appropriate for peeling effect of CFS.

  • PDF

격자형 용접 띠철근으로 보강된 콘크리트 기둥의 해석적 접근 (Analytical Approach on the Concrete Columns with Welded Reinforcement Grids)

  • 최창식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권1호
    • /
    • pp.137-146
    • /
    • 1999
  • Analysis of R/C columns requires modeling of the plastic hinge region, as well as nonlinear material characteristics. This becomes a challenging task in view of the nonlinearity of both steel and concrete. Furthermore, formation and progression of plasticity in the hinge is a difficult phenomenan to simulate, especially under reversed cyclic loading and decaying strength conditions. This research provide one analytical model employed in column analysis, including the analysis procedure for establishing inelastic force-deformation relationships. The analytical results show good correlation with experimental data. The employed procedure with the adopted analytical models can be used to compute inelastic displacements of concrete columns with welded reinforcement grids. The inelastic deformability beyond the peak was similar to those indicated by columns with conventional ties. The superior performance of columns with welded grids may be attributed to the improved confinement characteristics of grids associated with increased rigidity of welded ties.

  • PDF

보강재를 사용한 철근콘크리트 보의 휨·전단내력에 관한 실험적연구 (An Experimental Study on Flexural and Shear Strength of Reinforced Concrete Beam Using Reinforcing Materials)

  • 홍상균;은희창;박기철;정헌수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제1권1호
    • /
    • pp.65-73
    • /
    • 1997
  • In this paper, It is the effect of using fiber sheet (Carbon Fiber Sheet & Aramid Fiber Sheet) and Steel Plate for reinforced concrete beam. 25 specimens are tested, 16 specimens are for bending capacity and the other are for shear capacity. In the case of bending testing, the kind and quantity of the reinforcement materials, the bondage and the existence of crack were selected as experimental variables. In the case of shear testing, It is testified the effect of reinforcement with the variables of the method of reinforcement (side type and U type). As a result, Using the reinforcing materials can increase the capacity of bending and shear stress.

  • PDF

실험에 의한 피로하중을 받는 FRP패널 보강 RC보의 부착성능 (The Bond Performance of RC Beams Strengrhened for FRP Pannel deal with Fatigue Loadings through Experiments)

  • 이창규;정영배
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권3호
    • /
    • pp.105-115
    • /
    • 2007
  • 리모델링의 증가로 보수보강에 대하여 많은 관심을 갖게 되었다. 탄소섬유시트의 사용은 철근콘크리트 구조의 강성을 증가시키기 위하여 많이 쓰이고 있다. 따라서 새로운 보강방법으로 외부 부착에 의한 강성이 증가된 RC구조의 휨거동을 알아보기 위하여 실험과 분석 연구를 수행하였다. 또한 본 연구는 실험에 의한 피로하중을 받도록 한 FRP패널 보강방법에 대하여 살펴보는데 그 목적이 있다.

Lateral strain-axial strain model for concrete columns confined by lateral reinforcement under axial compression

  • Hou, Chongchi;Zheng, Wenzhong
    • Structural Engineering and Mechanics
    • /
    • 제84권2호
    • /
    • pp.239-251
    • /
    • 2022
  • The use of lateral reinforcement in confined concrete columns can improve bearing capacity and deformability. The lateral responses of lateral reinforcement significantly influence the effective confining pressure on core concrete. However, lateral strain-axial strain model of concrete columns confined by lateral reinforcement has not received enough attention. In this paper, based on experimental results of 85 concrete columns confined by lateral reinforcement under axial compression, the effect of unconfined concrete compressive strength, volumetric ratio, lateral reinforcement yield strength, and confinement type on lateral strain-axial strain curves was investigated. Through parameter analysis, it indicated that with the same level of axial strain, the lateral strain slightly increased with the increase in the unconfined concrete compressive strength, but decreased with the increase in volumetric ratio significantly. The lateral reinforcement yield strength had slight influence on lateral strain-axial strain curves. At the same level of lateral strain, the axial strain of specimen with spiral was larger than that of specimen with stirrup. Furthermore, a lateral strain-axial strain model for concrete columns confined by lateral reinforcement under axial compression was proposed by introducing the effects of unconfined concrete compressive strength, volumetric ratio, confinement type and effective confining pressure, which showed good agreement with the experimental results.

철근콘크리트 띠철근 기둥의 구속효과 (Confinement Effects of Reinforced Concrete Tied Columns)

  • 왕성근;한범석;이희수;신성우;반병열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.29-34
    • /
    • 2001
  • An experimental study was conducted to investigate the effectiveness of transverse reinforcement in reinforced concrete tied columns subjected to monotonically increasing axial compression. Eighteen large-scale columns(260$\times$260$\times$120mm) were fabricated to simulate similarly an actual structural members size. Effects of main variables such as the concrete compressive strength, the tie configuration, the transverse reinforcement ratio, the tie spacing, and the spatting of the concrete cover were studied in this research program.

  • PDF

개구부 보강철근을 갖는 철근콘크리트 연속 깊은 보의 구조적 거동 (Structural Behavior of Reinforced Concrete Continuous Deep Beams with Reinforcement around Opening)

  • 양근혁;홍성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.378-381
    • /
    • 2006
  • Test results of four reinforced concrete two-span continuous deep beams are summarized. Main variables were the configuration of web opening reinforcement. Shear span-to-overall depth ratio and the size of the web opening were fixed by 1.0 and 0.5 a $\times$ 0.2 h, respectively. To control diagonal crack and enhance strength, it can be recommended that diagonal reinforcement crossing the crack plane joining between loading points and corner of openings should be provided.

  • PDF