• 제목/요약/키워드: Structural dynamic analysis

검색결과 3,078건 처리시간 0.027초

Dynamic response of layered hyperbolic cooling tower considering the effects of support inclinations

  • Asadzadeh, Esmaeil;Alam, Mehtab;Asadzadeh, Sahebali
    • Structural Engineering and Mechanics
    • /
    • 제50권6호
    • /
    • pp.797-816
    • /
    • 2014
  • Cooling tower is analyzed as an assembly of layered nonlinear shell elements. Geometric representation of the shell is enabled through layered nonlinear shell elements to define the different layers of reinforcements and concrete by considering the material nonlinearity of each layer for the cooling tower shell. Modal analysis using Ritz vector analysis and nonlinear time history analysis by direct integration method have been carried out to study the effects of the inclination of the supporting columns of the cooling tower shell on its dynamic characteristics. The cooling tower is supported by I-type columns and ${\Lambda}$-type columns supports having the different inclination angles. Relevant comparisons of the dynamic response of the structural system at the base level (at the junction of the column and shell), throat level and at the top of the tower have been made. Dynamic response of the cooling tower is found to be significantly sensitive to the change of the inclination of the supporting columns. It is also found that the stiffness of the structure system increases with increase in inclination angle of the supporting columns, resulting in decrease of the period of the structural system. The participation of the stiffness of the tower in structural response of the cooling tower is fund to be dependent of the change in the inclination angle and even in the types of the supporting columns.

자기베어링 스테이지의 동적 거동 통합 시뮬레이션을 통한 제어 설계 (Integrated Dynamic Simulation of a Magnetic Bearing Stage and Control Design)

  • 김병섭
    • 한국생산제조학회지
    • /
    • 제22권4호
    • /
    • pp.730-734
    • /
    • 2013
  • The dynamic simulation of machine tools and motion control systems has been widely used for optimization, design verification, control design, etc. There are three main streams in dynamic simulation: structural dynamic analysis based onthe finite element method, dynamic motion analysis based on equations of motion, and control system analysis based on transfer functions. Generally, one of these dynamic simulation methods is chosen and employed for specific purposes. In this study, an integrated dynamic simulation is introduced, in which the structure, motion, and control dynamics are combined together. Commercially well-known software is used in the integrated dynamic simulation: ANSYS, ADAMS, and Matlab/Simulink. Using the integrated dynamic simulation, the dynamics of a magnetic bearing stage is analyzed and the causes of oscillation and noise are identified. A controller design for suppressing a flexible dynamic mode is carried out and verified through the integrated dynamic simulation.

케이블돔 구조물의 안정화 이행과정 및 구조적 거동특성에 관한 연구 (A Study on the Stabilizing Process and Structural Characteristics of Cable-Dome Structure)

  • 한상을;이경수;이주선;황보석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.260-267
    • /
    • 1999
  • In this paper, We propose the initial shape finding and dynamic analysis of cable dome structure are presented. Cable dome that is consist of three component such as cable, strut and fabric membrane have complex structural characteristics. Main structural system of cable dome is cable-strut tensegric system, and fabric membrane element Is conceived as cladding roof material. One of the important problem of cable dome is shape finding of those subjected to cable and membrane forces, which stabilize the structures. And the other is structural response from external load effect such as snow and wind When cable dome are subjected to dynamic load such as wind load each structural component has many important problem because of their special structural characteristics. One problem is that geometrical nonlinearity should be considered in the dynamic analysis because large deformation is occurred from their flexible characteristic. The other problem is that wrinkling occurs occasionally because cable and membrane elements can not transmit compressive forces. So this paper describe the physical structural response of cable dome structure.

  • PDF

불연속면의 영향을 고려한 암반동굴의 구조거동연구 (A Study on Structural Behavior of Underground Openings in Discontinuous Rock Masses)

  • 김선훈;최규섭;이경진;김진웅
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1991년도 봄 학술발표회 논문집
    • /
    • pp.20-25
    • /
    • 1991
  • In order to predict properly the effects of ground motion associated wi th earthquakes on underground radioactive waste disposal facilities, understanding of the structural behavior of an underground opening in discontinuous rook masses subjected to dynamic loadings is essential. Therefore, this paper includes literature review on computational models for discontinuous rook masses and on mathematical models for the structural analysis of underground openings. Then, structural analyses of underground openings using the distinct element computer program written for the static and dynamic analysis of discontinuous rook masses have been performed.

  • PDF

반도체 초정밀장비의 진동허용규제치를 고려한 지지구조의 동특성 개선에 관한 연구 (A Study on the Structural Dynamic Modification of Sub-structure of Clean Room Considering Vibration Criteria)

  • 손성완;이홍기;백재호
    • 반도체디스플레이기술학회지
    • /
    • 제2권2호
    • /
    • pp.25-30
    • /
    • 2003
  • In the case of a vibration sensitive equipment, it require a vibration free environment to provide its proper function. Especially, lithography and inspection device, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved Giga Class semi conductor wafers. This high technology equipments require very strict environmental vibration criteria in proportion to the accuracy of the manufacturing. In this paper, the dynamic analysis and modal test were performed to evaluate the dynamic properties of the constructing clean room structure. Based on these results, a structural dynamic modification(SDM) were required to satisfiy the vibration allowable limit for pression machine. Therefore, in order to improve the dynamic stiffness of clean room structure, the VSD system which can control the force applied on structure, were adopted and its utility were proved from dynamic test results of the improved structure after a modification work.

  • PDF

Closed-form and numerical solution of the static and dynamic analysis of coupled shear walls by the continuous method and the modified transfer matrix method

  • Mao C. Pinto
    • Structural Engineering and Mechanics
    • /
    • 제86권1호
    • /
    • pp.49-68
    • /
    • 2023
  • This study investigates the static and dynamic structural analysis of symmetrical and asymmetrical coupled shear walls using the continuous and modified transfer matrix methods by idealizing the coupled shear wall as a three-field CTB-type replacement beam. The coupled shear wall is modeled as a continuous structure consisting of the parallel coupling of a Timoshenko beam in tension (with axial extensibility in the shear walls) and a shear beam (replacing the beam coupling effect between the shear walls). The variational method using the Hamilton principle is used to obtain the coupled differential equations and the boundary conditions associated with the model. Using the continuous method, closed-form analytical solutions to the differential equation for the coupled shear wall with uniform properties along the height are derived and a numerical solution using the modified transfer matrix is proposed to overcome the difficulty of coupled shear walls with non-uniform properties along height. The computational advantage of the modified transfer matrix method compared to the classical method is shown. The results of the numerical examples and the parametric analysis show that the proposed analytical and numerical model and method is accurate, reliable and involves reduced processing time for generalized static and dynamic structural analysis of coupled shear walls at a preliminary stage and can used as a verification method in the final stage of the project.

경기장 구조물의 효율적인 진동해석 (Efficient Vibration Analysis of Stadium Structure)

  • 김기철;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.475-482
    • /
    • 2001
  • Stadium stand could be led to significant dynamic response due to rhythmical activities of spectator. The dynamic loads induced by spectators movements are considered as static loads in design standard of many countries but these loads have dynamic characteristics. So, it is desirable to apply measured dynamic loads created by spectator activities and to analyze the dynamic behavior of stadium system. The precise investigation of the dynamic loads on stadium structures and the accurate analysis of dynamic behavior of stadium systems are demanded for effective design. As the floor mesh of stadium stand is refined, the number of nodes increase in numerical analysis. So it is difficult to analyze entire stadium structures and much more computer memory are necessary for vibration analysis of stadium system. In this study, the various dynamic loads induced by spectator movements are measured and analyzed. And new modeling method that reduce the nodal points of stadium systems are introduced. Vibration analysis of stadium system is executed to inspect the accuracy and the efficiency of proposed method in this paper.

  • PDF

건전도 모니터링을 위한 P.C. 상자형 교량의 동적 특성 분석 (A Study on Dynamic Characteristics of P.C. Box Girder Bridge for Condition Monitoring)

  • 이선구;이성우
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.131-137
    • /
    • 1996
  • To perform condition monitoring of P.C. Box girder bridge under ambient traffic, dynamic characteristics were identified using the results of load test an analysis. It was found that natural frequencies obtained from the measured acceleration data for the forced vibration part and free vibration part were nearly identical. Thus it can be concluded that dynamic parameters are properly determined under ambient traffic condition. Finite element model for analysis was calibrated using measured frequencies. Change of dynamic characteristics were predicted through analysis of the established finite element model with anticipated change.

  • PDF

굴삭기의 정적/동적 강도 해석법에 대한 연구 (Study on the Static and Dynamic Structural Analysis Procedure of Excavators)

  • 정준모;김규성;장영식;최익흥;허민수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.537-543
    • /
    • 2003
  • This paper presents the improved procedure to assess static and dynamic strength of crawler type excavators. A fully integrated model including front attachment and chassis was prepared for structural analysis. In this paper, two types of loading input methods were investigated and the method imposing digging force directly on bucket tooth was more convenient than imposing cylinder reaction force on cylinder pin even if the two methods showed no discrepancy in analysis results. Static strength analysis was carried out for eight analysis scenarios based on two extreme digging positions, maximum digging reach position and maximum digging force positions. The results from static strength analysis were compared with measured stresses, cylinder pressures and digging forces and showed a good quantitative agreement with measured data. Dynamic strength analysis was carried out for simple reciprocation of boom cylinders. It was recognized that the effect of compressive stiffness of hydraulic oil was very important for dynamic structural behavior. The results from dynamic strength analysis including hydraulic oil stiffness were also compared with measured acceleration data and showed a qualitative agreement with measured data.

  • PDF

수동형 댐퍼를 장착한 구조물의 동적응답기반 신뢰성 해석 - 제1편: 부재별 파괴확률 산정 (Dynamic Response based Reliability Analysis of Structure with Passive Damper - Part 1: Assessment of Member Failure Probability)

  • 김승민;옥승용
    • 한국안전학회지
    • /
    • 제31권4호
    • /
    • pp.90-96
    • /
    • 2016
  • This study proposes a dynamic reliability analysis of control system as a method of quantitative evaluation of its performance in probabilistic terms. In this dynamic reliability analysis, the failure event is defined as an event that the dynamic response of the structural system exceeds a displacement limit, whereas the conventional reliability analysis method has limitations that do not properly assess the actual time history response of the structure subjected to dynamic loads, such as earthquakes and high winds, by taking the static response into account in the failure event. In this first paper, we discuss the control effect of the viscous damper on the seismic performance of the member-level failure where the failure event of the structural member consists of the union set of time-sequential member failures during the earthquake excitations and the failure probability of the earthquake-excited structural member is computed using system reliability approach to consider the statistical dependence of member failures between the subsequent time points. Numerical results demonstrate that the proposed approach can present a reliable assessment of the control performance of the viscous damper system in comparison with MCS method. The most important advantage of the proposed approach can provide us more accurate estimate of failure probability of the structural control system by using the actual time-history responses obtained by dynamic response analysis.