• Title/Summary/Keyword: Structural defects

Search Result 593, Processing Time 0.023 seconds

Thermal and Chemical Quenching Phenomena in a Microscale Combustor (I) -Fabrication of SiOx(≤2) Plates Using ion Implantation and Their Structural, Compositional Analysis- (마이크로 연소기에서 발생하는 열 소염과 화학 소염 현상 (I) -이온 주입법을 이용한 SiOx(≤2) 플레이트 제작과 구조 화학적 분석-)

  • Kim Kyu-Tae;Lee Dae-Hoon;Kwon Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.5 s.248
    • /
    • pp.397-404
    • /
    • 2006
  • Effects of surface defect distribution on flame instability during flame-surface interaction are experimentally investigated. To examine chemical quenching phenomenon which is caused by radical adsorption and recombination processes on the surface, thermally grown silicon oxide plates with well-defined defect density were prepared. ion implantation technique was used to control the number of defects, i.e. oxygen vacancies. In an attempt to preferentially remove oxygen atoms from silicon dioxide surface, argon ions with low energy level from 3keV to 5keV were irradiated at the incident angle of $60^{\circ}$. Compositional and structural modification of $SiO_2$ induced by low-energy $Ar^+$ ion irradiation has been characterized by Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS). It has been found that as the ion energy is increased, the number of structural defect is also increased and non-stoichiometric condition of $SiO_x({\le}2)$ is enhanced.

A Study on the Vibration Minimization Techniques for the Open Box Type Structure (열린 상자형 구조물의 진동 최소화 기법에 관한 연구)

  • 박석주;오재응;이장용;박성현
    • Journal of KSNVE
    • /
    • v.4 no.4
    • /
    • pp.479-486
    • /
    • 1994
  • The Finite Element Method(FEM) generally used for the structural analysis has some defects, i.e. a great deal of computational time and huge memory capacity of computer are needed in the application to large and/or complex structures, etc. Therefore the Component Mode Synthesis method(CMS), one of sub-structure synthesis methods, was made to improve such demerits and has been developed up to now. In optimum structural modification problems, the sensitivity analysis method is useful, where the sensitivity-calculated by Fox's suggestion-is defined as the diffentials of design variables for the objective values. This paper discusses the vibration minimization techniques for the oper box type structure, in which it is assumed that an engine operates at 10-40Hz range. The results obtained are as follow; (1) The sensitivity of natural frequency could be easily obtained by sensitivity analysis method and the optimum position to insert pillars could be found by using it. (2) The rates of structural modification could be exactly obtained and the natural frequency observed could be easily shifted to the objective value. (3) The maximum amplitude around natural frequency noted could be nearly reduced to 1/25 by modification.

  • PDF

Seismic Capacity Strengthened by GFS of Masonry Buildings with Earthquake Damage (지진피해를 입은 조적조 건축물의 유리섬유보강에 따른 내진성능)

  • Kwon, Ki-Hyuk;Choi, Sung-Mo;Lee, Soo-Cheul;Cho, Sang-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.231-237
    • /
    • 2004
  • Most of the masonry buildings have many structural defects under an earthquake load due to the small tensile force and ductility. In the foreign countries there are many the reinforcing methods of masonry buildings, but the glass fiber sheet reinforcements must be used due to various conditions in Korea. The purpose of this paper is to estimate the seismic capacity of masonry buildings damaged by earthquake and reinforced by Glass Fiber Sheet. On the basis of test results, the maximum base shear force and deformation of the masonry building with GFS were remarkably increased. From the comparison by existing strength equations and test data, the new strength equation of reinforced masonry buildings with GFS was developed.

Limit States and Corresponding Seismic Fragility of a Pipe Rack for Maintaining Operation (운전성 유지를 위한 파이프랙의 한계상태와 지진취약도)

  • Kim, Juram; Hong, Kee-Jeung;Hwang, Jin-Ha
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.283-291
    • /
    • 2023
  • Unlike other facilities, maintaining processes is essential in industrial facilities. Pipe racks, which support pipes of various diameters, are important structures used in industrial facilities. Since the transport process of pipes directly affects the operation of industrial facilities, a fragility curve should be derived based on considering not only the pipe racks' structural safety but also the pipes' transport process. There are several studies where the fragility curves have been determined based on the structural behavior of pipe racks. However, few studies consider the damage criteria of pipes to ensure the transportation process, such as local buckling and tensile failure with surface defects. In this study, an analysis model of a typical straight pipe rack used in domestic industrial facilities is constructed, and incremental dynamic analysis using nonlinear response history analysis is performed to estimate the parameters of the fragility curve by the maximum likelihood estimation. In addition, the pipe rack's structural behavior and the pipe's damage criteria are considered the limit state for the fragility curve. The limit states considered in this paper to evaluate fragility curves are more reasonable to ensure the transportation process of the pipe systems.

Impact Factor Analysis of Response Adjustment Factor of PSC Composite Bridge Using Optical Fiber Sensor (광섬유 센서를 이용한 PSC 합성형교의 응답보정계수 영향인자 분석)

  • Kim, Ho Sun;Jang, Hwa Sup;Yang, Dong Woon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.35-43
    • /
    • 2012
  • In general, load carrying capacity, one of the load & resistance capacities in bridges, has more margins than the load carrying capacity evaluated with theoretical methods, unless there are severe damages, defects or material deterioration phenomena that can have a great impact on the behavior of bridges. However, errors have been already included in the current processes of loading tests and structural analysis for measuring load carrying capacity, thus devaluing the reliability of response adjustment factor. Therefore, this study found out the problems of existing electric resistance strain and displacement sensors in sensor suite to solve the problems with sensors and the errors in the appropriateness of structural analysis model, thereby leading to the changes into an optical fiber smart sensor with excellent performance. Besides, the study attempted to ensure the accuracy of response adjustment factor by selecting the optimal models through the interpretation of various structural analysis models.

Fault Analysis of the Wind Turbine Drive Train in the Quefrency Region (큐프렌시 영역 해석을 통한 드라이브 트레인 결함 분석)

  • Park, Yong-Hui;Shi, Wei;Park, Hyun-Chul
    • New & Renewable Energy
    • /
    • v.9 no.3
    • /
    • pp.5-13
    • /
    • 2013
  • In the previous research, dynamic results have been analyzed in the time and frequency regions. Time and frequency region can be transformed by the Fourier transform. This transform is very useful about analyzing system behaviors. However, because of coupling, it cannot give clear results in the real system including lots of defects. In this paper, we introduced the analysis based on quefrency region to represent physical means clearly from complicated results. We simulated the drive train system which has defects, and compared between frequency and quefrency region to show its excellence. To do this process, We established mathematical model. The equation of motion was derived by the Lagrange equation and constraint equations. The constraint equation included relationships about gear mesh, flexibility of shaft. About numerical analysis, the Newmark beta method was used to get results. And FFT (Fast Fourier Transform) which converts results from time domain to frequency, qufrequency was used.

Suggestion of the defect score and condition grading protocol about sewer pipe (하수관로 결함 점수 및 상태 등급 판정 방법 제안)

  • Kim, Jungruyl;Lee, Jaehyun;Oh, Jeill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.21-28
    • /
    • 2017
  • This study was performed to propose the sewer defect scoring, and grading protocols for sewer condition assessment. For this, sewer defect scoring methods were comparatively analyzed and reviewed for four international condition assessment protocols, which are established based on WRc manual. As a result, we proposed a new protocol for sewer condition assessment, in which characteristics of sewer pipes are considered by segment. In reference to the PIM-3, the extent of ground subsidence was adopted to be of importance, and renewal scores increased in accordance with weighting of defects causing structural backfill materials. Also, defect grades of 'Hole' were extended to 5 levels of the grading, and 'Surface Damage' was excluded in defect assessment. The addition of 'Buckling' resulted in reduction of weights in 'Surface Damage' and 'Lining Defects'.

Stress Concentration Effects on the Nucleation of the Structural Defects in Highly Strained Heteroepitaxial Layers (高變形된 異種 에피층에서 응력 집중이 결정결함 생성에 미치는 영향)

  • Kim, Sam-Dong;Lee, Jin-Koo
    • Korean Journal of Materials Research
    • /
    • v.11 no.7
    • /
    • pp.615-621
    • /
    • 2001
  • We carried out the kinetic model calculations in order to estimate the nucleation rates for two kinds of half-loop dislocations in highly strained hetero-epitaxial growths; $60^{\circ}$dislocations and twinning dislocations. The surface defects and the stress concentration effects were considered in this model, and the remaining elastic strain of the epilayers with increasing film thickness was taken into account by using the modified Matthews' relation. The calculations showed that the stress concentration effect at surface imperfections is very important for describing the defect generation in highly mismatched epitaxial growth. This work also showed that the stress concentration effect determined the type of dislocation nucleating dominantly at early growth stages in accordance with our XTEM (cross-section transmission electron microscopy) defect observation.

  • PDF

Evaluation of Defect Types for Characteristic Database Construction of Large Sewage Box Culverts (대형 하수박스암거의 속성 데이터베이스 구축을 위한 결함유형 평가)

  • Han, Sangjong;Song, Homyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.619-628
    • /
    • 2017
  • As the 3D laser scanning technology capable of databaseing large sewage box culverts becomes possible, it is necessary to develop a standardization manual that can clearly distinguish the structural and operational defect types of box culver and analyze the defect data. In this study, we collected and analyzed defects in sewage box culverts of 14,827m in total by selecting three districts in Korea. The major defects were surface damages, and their defect densities were $2.17m^2/m$, $0.27m^2/m$ and $0.10m^2/m$ for aggregate exposure, Steel reinforcement exposure, and Steel reinforcement projecting. In order to support the decision of the box culverment management, it was divided into five grades and each defect code and defect score were allocated. The results of this study are useful for the diagnosis of the sewage box culverts in Korea and it is expected to support a decision making for management.

Analysis of temperature monitoring data for leakage detection of earth dam (흙댐의 누수구역 판별을 위한 온도 모니터링 자료의 해석)

  • Oh, Seok-Hoon;Seo, Baek-Soo
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.39-45
    • /
    • 2008
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF