• 제목/요약/키워드: Structural and non-structural wall

검색결과 169건 처리시간 0.024초

유동가속부식이 잠재한 곡관내의 3차원 난류유동 해석 (Three-dimensional Turbulent Flow Analysis in Curved Piping Systems Susceptible to Flow-Accelerated Corrosion)

  • 조종철;김윤일;최석기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.900-907
    • /
    • 2000
  • The three-dimensional turbulent flow in curved pipes susceptible to flow-accelerated corrosion has been analyzed numerically to predict the pressure and shear stress distributions on the inner surface of the pipes. The analysis employs the body-fitted non-orthogonal curvilinear coordinate system and a standard $ {\kappa}-{\varepsilon}$ turbulence model with wall function method. The finite volume method is used to discretize the governing equations. The convection term is approximated by a high-resolution and bounded discretization scheme. The cell-centered, non-staggered grid arrangement is adopted and the resulting checkerboard pressure oscillation is prevented by the application of a modified version of momentum interpolation scheme. The SIMPLE algorithm is employed for the pressure and velocity coupling. The numerical calculations have been performed for two curved pipes with different bend angles and curvature radii, and discussions have been made on the distributions of the primary and secondary flow velocities, pressure and shear stress on the inner surface of the pipe to examine applicability of the present analysis method. As the result it is seen that the method is effective to predict the susceptible systems or their local areas where the fluid velocity or local turbulence is so high that the structural integrity can be threatened by wall thinning degradation due to flow-accelerated corrosion.

  • PDF

지하 콘크리트 벽체용 미가황 합성고무시트 방수재의 물성에 관한 실험적 연구 (An Experimental Study on the Physical Property of Non-Vulcanized Waterproofing Synthetic Rubber Sheet for the Underground Concrete Wall)

  • 최은수;이대우;서상교
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권4호
    • /
    • pp.69-78
    • /
    • 2012
  • 본 연구는 콘크리트 지하구조물 외부에 적용하는 방수공법으로 120일 후 가황되도록 가황제, 가황조제 등을 첨가하여 배합제조된 합성고무시트 방수재로써 약 85일의 delay time과 약 35일의 curing time을 가지며, 이때 인장강도는 약 692%가 증가하고, 신장률은 약 10% 감소하여, 일반시트의 시공시 단점을 미가황상태로 시공되어 보완하고, 상온에서 가황하여 내구성능을 확보할 수 있는 것으로 나타났다. 또한 가황직후 및 가황 1년 후의 각종 열화요인에 대한 내구성능을 평가한 결과 관련 품질기준을 만족하며, 미가황 상태에서의 합성고무 시트에 보호모르타르를 시공하여 접착성능을 평가한 결과 첨가된 실리케이트에 의하여 보호모르타르와 수화반응에 의한 양호한 부착성능이 확보되는 것으로 나타났다.

유공벽이 설치된 부유체 동요 평가를 위한 주파수 영역 해석 (Frequency-Domain Analysis for Motion of Floating Structures with Perforated Wall)

  • 김정수;정연주;김영택
    • 한국해안·해양공학회논문집
    • /
    • 제36권1호
    • /
    • pp.1-10
    • /
    • 2024
  • 해상 산업시설을 중심의 부유식 구조물 수요가 생활 밀접형 시설로 점차 확대됨에 따라, 부유 구조물의 동요를 저감하기 위한 기술 필요성이 대두되고 있다. 본 연구는 부유체 외부에 유공벽이 설치된 부유식 구조물을 제시하고, 규칙파 및 불규칙파 조건에서의 주파수 영역 해석을 통해 해당 구조물의 응답을 조사하였다. 제안된 구조물은 내부 부유체와 유공벽이 포함된 외부 부유체가 결합된 형태로, 유공률별(0~30%) 해석 모델을 생성해 부유체 중심점과 가장자리에서의 상하 및 회전 동요가 비교되었다. 해석 결과는 유공벽의 유공률 증가를 통해 부유체의 상하 및 회전 동요를 저감할 수 있음을 보여주었다. 또한 제안된 부유체를 사용함으로써 무유공 부유체 대비 규칙파와 불규칙파 조건에서 각각 10%, 2% 내외의 응답 감소 효과가 나타남을 확인할 수 있었다.

Symbolic computation and differential quadrature method - A boon to engineering analysis

  • Rajasekaran, S.
    • Structural Engineering and Mechanics
    • /
    • 제27권6호
    • /
    • pp.713-739
    • /
    • 2007
  • Nowadays computers can perform symbolic computations in addition to mere number crunching operations for which they were originally designed. Symbolic computation opens up exciting possibilities in Structural Mechanics and engineering. Classical areas have been increasingly neglected due to the advent of computers as well as general purpose finite element software. But now, classical analysis has reemerged as an attractive computer option due to the capabilities of symbolic computation. The repetitive cycles of simultaneous - equation sets required by the finite element technique can be eliminated by solving a single set in symbolic form, thus generating a truly closed-form solution. This consequently saves in data preparation, storage and execution time. The power of Symbolic computation is demonstrated by six examples by applying symbolic computation 1) to solve coupled shear wall 2) to generate beam element matrices 3) to find the natural frequency of a shear frame using transfer matrix method 4) to find the stresses of a plate subjected to in-plane loading using Levy's approach 5) to draw the influence surface for deflection of an isotropic plate simply supported on all sides 6) to get dynamic equilibrium equations from Lagrange equation. This paper also presents yet another computationally efficient and accurate numerical method which is based on the concept of derivative of a function expressed as a weighted linear sum of the function values at all the mesh points. Again this method is applied to solve the problems of 1) coupled shear wall 2) lateral buckling of thin-walled beams due to moment gradient 3) buckling of a column and 4) static and buckling analysis of circular plates of uniform or non-uniform thickness. The numerical results obtained are compared with those available in existing literature in order to verify their accuracy.

Influence of tilt and surface roughness on the outflow wind field of an impinging jet

  • Mason, M.S.;Wood, G.S.;Fletcher, D.F.
    • Wind and Structures
    • /
    • 제12권3호
    • /
    • pp.179-204
    • /
    • 2009
  • A physical and numerical steady flow impinging jet has been used to simulate the bulk characteristics of a downburst-like wind field. The influence of downdraft tilt and surface roughness on the ensuing wall jet flow has been investigated. It was found that a simulated downdraft impinging the surface at a non-normal angle has the potential for causing larger structural loads than the normal impingement case. It was also found that for the current impinging jet simulations, surface roughness played a minor role in determining the storm maximum wind structure, but this influence increased as the wall jet diverged. However, through comparison with previous research it was found that the influence of surface roughness is Reynolds number dependent and therefore may differ from that reported herein for full-scale downburst cases. Using the current experimental results an empirical model has been developed for laboratory-scale impinging jet velocity structure that includes the influence of both jet tilt and surface roughness.

Simplified finite element modelling of non uniform tall building structures comprising wall and frame assemblies including P-Δ effects

  • Belhadj, Abdesselem Hichem;Meftah, Sid Ahmed
    • Earthquakes and Structures
    • /
    • 제8권1호
    • /
    • pp.253-273
    • /
    • 2015
  • The current investigation has been conducted to examine the effect of gravity loads on the seismic responses of the doubly asymmetric, three-dimensional structures comprising walls and frames. The proposed model includes the P-${\Delta}$ effects induced by the building weight. Based on the variational approach, a 3D finite element with two nodes and six DOF per node including P-${\Delta}$ effects is formulated. Dynamic and static governing equations are derived for dynamic and buckling analyzes of buildings braced by wall-frame systems. The influences of P-${\Delta}$ effects and height of the building on tip displacements under Hachinohe earthquake record are investigated through many structural examples.

Assessment of seismic strengthening solutions for existing low-rise RC buildings in Nepal

  • Chaulagain, Hemchandra;Rodrigues, Hugo;Spacone, Enrico;Varum, Humberto
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.511-539
    • /
    • 2015
  • The main objective of this study is to analytically investigate the effectiveness of different strengthening solutions in upgrading the seismic performance of existing reinforced concrete (RC) buildings in Nepal. For this, four building models with different structural configurations and detailing were considered. Three possible rehabilitation solutions were studied, namely: (a) RC shear wall, (b) steel bracing, and (c) RC jacketing for all of the studied buildings. A numerical analysis was conducted with adaptive pushover and dynamic time history analysis. Seismic performance enhancement of the studied buildings was evaluated in terms of demand capacity ratio of the RC elements, capacity curve, inter-storey drift, energy dissipation capacity and moment curvature demand of the structures. Finally, the seismic safety assessment was performed based on standard drift limits, showing that retrofitting solutions significantly improved the seismic performance of existing buildings in Nepal.

보강상세에 따른 프리캐스트 변형경화형 시멘트 복합체 끼움벽의 내진성능 (Effect of Reinforcement details on the Seismic Performance of Precast Strain-Hardening Cementitious Composite(SHCC) Infill Walls)

  • 김선우;윤현도;송선화;윤여진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권3호통권55호
    • /
    • pp.209-216
    • /
    • 2009
  • 비내진상세 골조는 낮은 횡저항성을 가지고 있어 큰 변형을 경험하게 되는 반면, 벽체는 높은 강성으로 인해 낮은 변형에서도 전단에 의해 파괴된다. 따라서 이러한 골조와 벽체가 동시에 거동할 경우 발생하는 거동 특성은 개개 부재에서의 거동특성과 매우 다르게 된다. 본 연구에서는 끼움벽에 노치를 둘 경우 내진거동특성을 평가하고자 배근상세를 변수로 하였다. 이 때 노치로 인해 벽체 중앙부에 손상이 집중되는 것을 방지하기 위하여 변형경화형 시멘트 복합체(SHCC)를 사용하였다. 실험결과, SHCC 끼움벽은 다수의 미세균열을 형성하였으나, 대각보강근을 갖는 PIW-ND 실험체가 PIW-NC 실험체에 비해 낮은 변형능력, 강성 및 에너지소산능력을 보였다.

진동대실험을 통한 비내진상세를 가지는 RC 골조의 조적채움벽 유무에 따른 동적 거동 평가 (Dynamic Behaviour of Masonry inFilled Reinforced Concrete Frames with Non-Seismic Details)

  • 백은림;김경민;천주현;오상훈;이상호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권3호
    • /
    • pp.121-129
    • /
    • 2017
  • 본 논문에서는 국내 비내진상세 조적채움벽 RC 골조의 동적거동 및 손상모드를 파악하기 위하여 실규모 크기의 비내진상세 RC 골조와 조적채움벽 RC 골조를 대상으로 진동대 실험을 실시하여 응답 및 거동 특성을 비교 평가하였다. 진동대 실험 결과, 순수 RC 골조는 기둥상하부 휨균열 및 접합부 전단균열이 심화되어 최종 파괴되었다. 조적채움벽 RC 골조의 경우 골조의 손상은 비교적 작았으며 조적벽체의 중앙부의 슬라이딩 균열 및 대각 전단 균열 손상이 크게 발생하였다. 조적채움벽 RC 골조는 순수 RC 골조에 비하여 초기상태의 공진주기가 짧아졌으며 최종 가진시에서 최대변위응답은 약 62% 감소하였다. 본 연구에서 적용한 조적채움벽은 비내진 상세를 가지는 RC 골조의 강성을 약 1.6배, 최대 강도를 약 2.2배 증가시키는 데 기여하는 것으로 분석되었다.

강봉댐퍼로 보강한 기존 저층 철근콘크리트 필로티 건물의 내진성능 (Seismic Performance of an Existing Low-Rise Reinforced Concrete Piloti Building Retrofitted by Steel Rod Damper)

  • 백은림;오상훈;이상호
    • 한국지진공학회논문집
    • /
    • 제18권5호
    • /
    • pp.241-251
    • /
    • 2014
  • In this study, shaking table test was carried out to evaluate the seismic behavior and performance of low-rise reinforced concrete (RC) piloti structures with and without retrofit. The specimens were designed considering the characteristics of existing building with pilotis such as natural period, distribution factor of strength and stiffness between columns and core wall on the first soft story. The test for the non-retrofit specimen showed that damage was concentrated on the stiffer member on the same floor as the core wall failed by shear fracture whereas columns experienced slight flexural cracks. Considering the failure mode of the non-retrofit specimen, the retrofit method using steel rod damper was presented for improving the seismic performance of piloti structures. The results of the test for retrofit specimen revealed that the retrofit method was effective for controlling the damage as the main RC structural members were not destroyed and most of input energy was dissipated by hysteretic behavior of the damper.