• Title/Summary/Keyword: Structural Weight

Search Result 2,484, Processing Time 0.025 seconds

Study on Optimal Design of Traverse Switch System for Maglev Train (자기부상열차용 트레버스 분기기 최적설계 연구)

  • Lee, Younghak;Kim, Chang-Hyun;Lee, Jong-Min
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.6
    • /
    • pp.717-726
    • /
    • 2016
  • Emergency tracks are necessary in case a broken down train evacuates, a train needs to make way for a faster train behind it, or a train suddenly stops and following trains must avoid colliding with it. Magnetic Levitated (maglev) Trains can change track to enter an emergency track using a segmented switch or a traverse switch. On a traverse switch, a train can change its track when the part of the track that the train is on moves to the other track. Currently manufactured Maglev trains have two bodies and the total length is 25 meters. If a traverse switch is used, it will only require 30 meters of track to move the train to the other track, so, when it comes to efficiency of costs and space, the traverse switch surpasses the articulated switch. Therefore, in this paper, an optimized design to secure structural safety and weight lightening is suggested. To achieve these results, the heights of the piled concrete and girders which are both placed on the top of the traverse switch, are set as design variables. The Finite Element Method (FEM), in application of kriging and in the design of the experiments (DOE), is used. Maximum stress, deformation, and structural weight are compared with the results, and through this process structural safety and weight lightening is proven.

Shear Resistance of Light-gauge Steel Stud Wall infilled with light-weight foamed mortar (경량기포모르터와 합성한 경량형강 벽체의 전단 저항)

  • Lee, Sang Sup;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.397-406
    • /
    • 2004
  • This paper presents the test and evaluation results on the shear strength and stiffness of a light steel stud wall from a lightweight foamed mortar (lightweight hybrid wall). The use of a lightweight foamed mortar was aimed at improving structural performance, thermal performance, and finish. Studiesshowed that it did not affect thermal performance, but it contributed to structural performance and finish when the unit weight was more than 0.8 (Editor's note: Please indicate the unit of measurement.). In this study, 14 specimens-whose parameters included the specific gravity of the lightweight foamed mortar (0.6, 0.8, 1.0, 1.2), the spacing of the stud (450 mm, 600 mm, or 900 mm), finishing materials (such as lightweight foamed mortar, OSB, and gypsum board), and bracing-were manufactured. Three typical, steel house-framing specimens were added to compare the test results with the 14 specimens. The results of in-plane shear tests show that the use of lightweight foamed mortar (1.15~5.38 times stronger, 1.45~13.7 times stiffer) results in ultimate strength and initial stiffness. In addition, it was possible to widen the stud spacing to up to 900 mm without decreasing shear strength. It was very important to prevent the lightweight foamed mortar from shrinking and to secure the adhesion between the steel stud and the lightweight foamed mortar to improve structural performance.

Cell Opening of High Resilience Polyurethane foam II. Structure Effect of Polyether Type Cell Opener (고탄성 폴리우레탄 발포체의 기포개방 II. 폴리에테르형 기포개방제의 구조 영향)

  • 송기천;이상목;이동호
    • Polymer(Korea)
    • /
    • v.26 no.2
    • /
    • pp.218-226
    • /
    • 2002
  • For the preparation of high resilience polyurethane (PU) foams with polyether type cell openers which have different ethylene oxide (EO) content, molecular weight and chain structure, the influences of tell opener structure on the kinetics, rheology, structural stability, open cell content and mechanical properties of the obtained foam were investigated. It was observed that urea formation reaction was delayed with the increase of EO content and incorporation of ester linkage in cell opener molecule and was relatively independent on the molecular weight. With the rheological studies, the decreases of viscosity and storage modulus were confirmed for the increase of EO content and molecular weight, so that the resulted foam had low structural stability and high open cell content. The cell opener having ester linkage in molecule exhibited the lowest values of viscosity and storage modulus and the obtained foam has high open cell content. However, the structural stability increased due to the larger intermolecular interaction of ester linkage. The hardness, tensile strength, tear strength and elongation of foam were deteriorated with increase of EO content and molecular weight of tell opener. On the other hand, the cell opener having ester linkage in molecule improved the values of tensile strength, tear strength and elongation.

On the Bearing-to-Bearing Variability in Experimentally Identified Structural Stiffnesses and Loss Factors of Bump-Type Foil Thrust Bearings under Static Loads (범프 타입 포일 스러스트 베어링의 정하중 구조 강성 및 손실 계수 차이에 관한 실험적 연구)

  • Lee, Sungjin;Ryu, Keun;Jeong, Jinhee;Ryu, Solji
    • Tribology and Lubricants
    • /
    • v.36 no.6
    • /
    • pp.332-341
    • /
    • 2020
  • High-speed turbomachinery implements gas foil bearings (GFBs) due to their distinctive advantages, such as high efficiency, lesser part count, and lower weight. This paper provides the test results of the static structural stiffnesses and loss factors of bump-type foil thrust bearings with increasing preload and bearing deflection. The focus of the current work is to experimentally quantify variability in structural stiffnesses and loss factors among the four test thrust bearings with identical design values and material of the bump and top foil geometries using the same (open-source) fabrication method. A simple test setup, using a rigidly mounted non-rotating shaft and thrust disk, measures the bearing bump deflections with increasing static loads on the test bearing. The inner and outer diameters of the test bearings are 41 mm and 81 mm, respectively. The loss factor, best-representing energy dissipation in the test bearings, is estimated from the area inside the local hysteresis loop of the load versus the bearing deflection curve. The measurements show that structural stiffnesses and loss factors of the test bearings significantly rely on applied preloads and bearing deflections. Local structural stiffnesses of the test bearings increase with applied preloads but decrease with bearing deflections. Changes of loss factors are less sensitive to applied preloads and bearing deflections compared to those of structural stiffnesses. Up to 35% variability in static load structural stiffnesses is found between bearings, while up to 30% variability in loss factors is found between bearings.

Structural Characteristics of Low Molecular Weight Laminarin Prepared by Ionizing Irradiation (이온화 방사선 조사에 의해 얻어진 저분자 laminarin의 분자구조 특성)

  • Choi, Jong-Il
    • Korean Chemical Engineering Research
    • /
    • v.51 no.6
    • /
    • pp.780-783
    • /
    • 2013
  • Recently, it has been reported that low molecular weight laminarin had the enhanced biological activities. In this study, molecular structure of low molecular weight laminarin prepared by ionizing irradiation was studied. Low molecular weight laminarin samples of 13.5, 8.5, 7, and 6 kDa were obtained from 15 kDa laminarin by irradiation. From gel permeation chromatography data, low molecular weight laminarin was shown to have low polydispersity. To define the changes of functional groups in laminarin with different molecular weights, Fourier-transform infrared analysis was carried out. There was found no significant changes of functional groups in low molecular weight laminarin, except the increase of carbonyl group. The granular fissures from scanning electron microscopy showed the breakage of glycosidic bond in low molecular weight laminarin. These results could be utilized for the investigation of the enhanced biological activities of low molecular weight polysaccharides including laminarin.

Ecological Niche Overlap and Competition between Quercus mongolica and Quercus dentata Under Soil Water Gradient

  • Yeon-ok, Seo;Se-Hee, Kim;Eui-Joo, Kim;Yoon-Seo, Kim;Kyeong-Mi, Cho;Jae-Hoon, Park;Ji-Won, Park;JungMin, Lee;Jin Hee, Park;Byoung-Ki, Choi;Young-Han, You
    • Journal of Forest and Environmental Science
    • /
    • v.38 no.4
    • /
    • pp.229-238
    • /
    • 2022
  • Q. mongolica and Q. dentata are representative species of deciduous forest communities in Korea and are known to be relatively resistant to soil drying condition among Korean oaks. This study attempted to elucidate the degree of competition and ecological niche characteristics of the two species by comparing the ecological responses of the two species according to soil moisture. Competition between Q. mongolica and Q. dentata was shown to be more intense under the conditions where moisture content was low than under the conditions where moisture content was high. As for the ecological niche overlaps of the two species for soil moisture, the structural traits of plant such as stem diameter overlapped the most, the traits of biomass such as petiole weight overlapped the least, and photosynthetic organ-related traits such as leaf width and length overlapped intermediately. When looking at the competition for soil moisture between the two species, it can be seen that Q. mongolica won in nine traits (leaf width length, leaf lamina length, leaf lamina weight, leaf petiole weight, leaf area, leaves weight, shoot weight, root weight, and plant weight) and Q. dentata won in the remaining seven traits (leaf petiole length, leaves number, stem length, stem diameter, stem weight, shoot length, and root length). Competition between the two species for the moisture environment of the soil was shown to be intense under the conditions where moisture content was low. The degree of competition between Q. dentata and Q. mongolica for soil moisture is high under the conditions where soil moisture content is low, and it is judged that Q. mongolica is more competitive for soil moisture than Q. dentata.

Development of Model for Structural Evaluation of Anti-Freezing Layer (동상방지층의 구조적 평가를 위한 모형 개발)

  • Lee, Moon-Sup;Heo, Tae-Young;Park, Hee-Mun;Kim, Boo-Il
    • International Journal of Highway Engineering
    • /
    • v.14 no.3
    • /
    • pp.25-32
    • /
    • 2012
  • The thickness of anti-freezing layer has been empirically determined using the frost depth obtained from the freezing index and has not been generally considered as a structural layer in pavement design procedure. In fact, the anti-freezing layer makes a role in structural layer and enables to reduce the total thickness of pavement system. The objective of this study is to develop the statistical regression model for evaluating the structural capacity of anti-freezing layer using Falling Weight Deflectormeter(FWD) test data in asphalt pavements. The FWD testing was conducted at the embankment, cutting, and boundary area of various test sections to estimate the structural capacity of anti-freezing layer in different foundation condition. It is observed from this testing that the center deflections of pavement structure with anti-freezing layer are smaller than those without anti-freezing layer ranging from 0.4 to 82.6%. To determine the variables of statistical model, the correlation study has been conducted between various FWD deflection indexes and the anti-freezing layer thickness. It is found that the ${\Delta}BDI$(%)(${\Delta}Basin$ Damage Index(%)) is highly correlated with anti-freezing layer thickness. The ${\Delta}BDI$(%) model were developed for evaluating structural capacity of anti-freezing layer using linear mixed-effect models.

Technique to Evaluate Safety and Loaded Heavy Equipment Grade in RC Building during Demolition Work (RC건축물 해체공사의 안전성 평가기법 및 탑재장비 등급 제안)

  • Park, Seong-Sik;Lee, Bum-Sik;Kim, Hyo-Jin;Sohn, Chang-Hak
    • Land and Housing Review
    • /
    • v.2 no.2
    • /
    • pp.195-204
    • /
    • 2011
  • During mechanical demolition of RC structures, weights of dismantling equipment and demolition waste of building are applied to unexpected load which did not be considered during the design of structural member. Nevertheless, the loading of dismantling equipment and dismantling process are mainly dependent on field managers' field workers' or experiences without considering safety of structural member by a structural engineer. It is urgently required that reflecting actual circumstance of mechanical demolition, safety evaluation method to evaluate the safety and the guideline for appropriate capacity of structural member to support dismantling equipment weight, be provided. Through site investigation and questionnaire on field workers, this paper proposed demolition waste load, load factor, strength reduction factor, and so on. These are essential to safe evaluation of a building, ready to demolition. Considering actual circumstance of mechanical demolition, safety evaluation method of building and design method of slab and beam was suggested to a dilapidated building. An capability to loading of dismantling equipment was proposed, applied to RC slab and RC beam. Therefore, the suggested safety evaluation method and the guideline for an capability to loading of dismantling equipment weight can reasonably evaluate the capacity of structural member in demolition and use effectively as increasing efficiency and improving safety of demolition through proper management of dismantling equipments.

Structural Design Optimization of Lightweight Offshore Helidecks Using a Genetic Algorithm and AISC Standard Sections (유전 알고리듬 및 AISC 표준 단면을 사용한 경량화 헬리데크 구조 최적설계)

  • Sim, Kichan;Kim, Byungmo;Kim, Chanyeong;Ha, Seung-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.6
    • /
    • pp.383-390
    • /
    • 2019
  • A helideck is one of the essential structures in offshore platforms for the transportation of goods and operating personnel between land and offshore sites. As such, it should be carefully designed and installed for the safety of the offshore platform. In this study, a structural design optimization method for a lightweight offshore helideck is developed based on a genetic algorithm and an attainable design set concept. A helideck consists of several types of structural members such as plates, girders, stiffeners, trusses, and support elements, and the dimensions of these members are typically pre-defined by manufacturers. Therefore, design sets are defined by collecting the standard section data for these members from the American Institute of Steel Construction (AISC), and integer section labels are assigned as design variables in the genetic algorithm. The objective is to minimize the total weight of the offshore helideck while satisfying the maximum allowable stress criterion under various loading conditions including self-weight, wind direction, landing position, and landing condition. In addition, the unity check process is also utilized for additional verification of structural safety against buckling failure of the helideck.

A Study on the Flow Analysis for KP505 Propeller Open Water Test (유체기기의 표면 금속코팅 적용에 따른 구조건전성 평가)

  • Lee, Han-Seop;Lim, Byung-Chul;Kim, Min-Tae;Lee, Beom-Soon;Park, Sang-Heup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.23-28
    • /
    • 2019
  • The structural integrity of a surface metal coating was evaluated through numerical results to improve the efficiency and reduce the damage caused by cavitation in ships and marine plants. The goal was to ensure structural strength and performance, even if the thickness of the wing is reduced to reduce the weight of the material and surface coating. Analytical methods were used for four models: a non-coating model, one with the same thickness after coating, one with a thickness reduction of 3% after coating, and one with thickness reduction of 5% after coating. With a thickness reduction of 5% after coating, the stress was increased to 12%, and the safety factor was 0.99%, so the structural integrity was insufficient. However, a better material or a thicker coating could allow a sufficient safety factor to be secured. The structural integrity was improved by the coating, and even when the weight was reduced up to 5%, the structural integrity could be sufficiently secured due to the coating effect.