• Title/Summary/Keyword: Strong floor

Search Result 126, Processing Time 0.027 seconds

Seismic characteristics of a Π-shaped 4-story RC structure with open ground floor

  • Karabini, Martha A.;Karabinis, Athanasios J.;Karayannis, Chris G.
    • Earthquakes and Structures
    • /
    • v.22 no.4
    • /
    • pp.345-353
    • /
    • 2022
  • The configuration of an open ground floor (pilotis) is a common and very critical irregularity observed in multistory reinforced concrete frame structures. The characteristics and the geometrical formation of the beams of the first story proved to be a critical parameter for the overall seismic behavior of this type of Reinforced Concrete (RC) structures. In this work the combination of open ground floor (pilotis) morphology with very strong perimetrical beams at the level of the first story is studied. The observation of the seismic damages and the in situ measurements of the fundamental period of four buildings with this morphology and Π-shaped plan view are presented herein. Further analytical results of a pilotis type Π-shaped RC structure are also included in the study. From the measurements and the analytical results yield that the open ground floor configuration greatly influences the fundamental period whereas this morphology in combination with strong beams can lead to severe local shear damages in the columns of the ground floor. The structural damage was limited in the columns of the ground floor and yet based on the changes of the in situ measured fundamental period the damaged level is assessed as DI=88%. Furthermore, due to the Π-shape of the plan view the tendency of the parts of the building to move independently strongly influences the distribution of the damages over the ground floor vertical elements.

Transient Heat Conduction Through the Ondol Floor and Beat toss to the Ground (온돌의 구들장과 땅바닥의 비정상 열전도 해석)

  • Bae, Soon-Hoon;Kim, Doo-Chun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.1
    • /
    • pp.6-17
    • /
    • 1975
  • For a periodic variation of the flue gas temperature the heat conduction through the Ondol floor was analysized. Also the heat loss to the ground was estimated. The floor thermal capacity, as a function of the floor thickness, has strong influence on the time lag of the temperature variation. It is an important design parameter for intermittent heating. Even for the steady periodic variation, there was significant heat loss to the ground below the Ondol floor.

  • PDF

Design Approach of Large-scale Experimental Facilities Reflect the Load Flow (하중흐름을 통한 대형구조실험용 반력시설물의 설계)

  • Lee, Sung-Eun;Ko, Dong-Woo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.69-77
    • /
    • 2016
  • The purpose of this study is to present a method that can estimate the height of reaction facilities for large structural experiment through load flow as primary design procedure. The characteristic of the load transmission according to the type of experiment was analyzed to obtain tensile and compressive forces occurring on the reaction facilities. Strong walls that are affected by the bending moment is applied the post-tensioning method, and the strong floor under the control of the tension and compression is designed in accordance with the load flow. And the optimum cross-section of the reaction facilities was obtained by comparing the stresses of the tensile stress and crack the concrete. Through validating elastic analysis, the design results were satisfied a given design conditions.

Contemporary Space Design Trends on the Floor Plan Analysis of Rural Houses in So-yang Munhwa Village (소양 문화마을 주택의 평면 특성을 통해 본 최근 농촌주거의 공간 디자인 경향)

  • Choi, Byung-Sook
    • Journal of the Korean housing association
    • /
    • v.17 no.6
    • /
    • pp.65-72
    • /
    • 2006
  • This study was to and out contemporary space design trends of rural houses in So-yang Munhwa village by analyzing their floor plan shapes and space relations & elements of floor plans. There were built 71 houses in that village but it were possible to collect housing data, floor plans & general building records of 41 houses, from house register. By analyzing those data, findings were as follows : 1) Floor plan shapes of rural houses had a tendency to be diverse, various form of 'ㅋ' than simple form of 'ㅡ'. 2) Room-Living-Room, 3 bay arrangement was very strong trends, and traditional planning characteristics that the openness of living space was keeping. 3) Anbang(master bedroom) and living space were important, so two spaces were set forth of floor plan and Anbang with a bathroom were often showed. 4) DK space and its relation to other spaces were important factor to classily 2 floor plan types of them. 5) DK(dining kitchen) space had an openness from back entrance and DK were separated from public spaces L.D.K. Utility or balcony/veranda spaces as a support space of kitchen were planned in rural houses, and they were influenced from apartment houses or urban houses.

Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance (바닥충격음 측정 및 차음 평가의 방향)

  • Jeong, Jeong-Ho;Jeong, Yeong;Seo, Sang-Ho;Song, Hee-Soo;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

An Analysis on Floor Planning Characteristics of Rural houses in Na-po Munwha Village (나포 문화마을 주택의 평면적 특성 분석)

  • Ryou, Ok-Soon;Choi, Byung-Sook
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.208-211
    • /
    • 2006
  • This study was to find out contemporary planning trends of rural houses in Na-po Munhwa village by analyzing their floor plan shapes and space relations & elements. There were built 240 houses in that village, but it were possible to collect housing data, floor plans & general building records of 120 houses, from house register. By analyzing those data, findings were as follows : 1) Floor plan shapes of rural houses had a tendency to 'ㅋ' shape type than simple box or transformed box types, and Room-Living-Room arrangement of centered living were very strong trends in those plans. 2) Public spaces, L.D.K

  • PDF

Real-time seismic structural response prediction system based on support vector machine

  • Lin, Kuang Yi;Lin, Tzu Kang;Lin, Yo
    • Earthquakes and Structures
    • /
    • v.18 no.2
    • /
    • pp.163-170
    • /
    • 2020
  • Floor acceleration plays a major role in the seismic design of nonstructural components and equipment supported by structures. Large floor acceleration may cause structural damage to or even collapse of buildings. For precision instruments in high-tech factories, even small floor accelerations can cause considerable damage in this study. Six P-wave parameters, namely the peak measurement of acceleration, peak measurement of velocity, peak measurement of displacement, effective predominant period, integral of squared velocity, and cumulative absolute velocity, were estimated from the first 3 s of a vertical ground acceleration time history. Subsequently, a new predictive algorithm was developed, which utilizes the aforementioned parameters with the floor height and fundamental period of the structure as the new inputs of a support vector regression model. Representative earthquakes, which were recorded by the Structure Strong Earthquake Monitoring System of the Central Weather Bureau in Taiwan from 1992 to 2016, were used to construct the support vector regression model for predicting the peak floor acceleration (PFA) of each floor. The results indicated that the accuracy of the predicted PFA, which was defined as a PFA within a one-level difference from the measured PFA on Taiwan's seismic intensity scale, was 96.96%. The proposed system can be integrated into the existing earthquake early warning system to provide complete protection to life and the economy.

Contemporary Planning Trends of Rural Houses in So-yang Munhwa Village- Analysis of Floor Plan Shapes and Space Relations & Elements - (소양 문화마을 주택의 평면적 특성을 통해 본 농촌 주거공간의 현시대적 패턴)

  • Choi, Byung-Sook;Park, Sun-Hee
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.103-106
    • /
    • 2005
  • This study was to find out contemporary planning trends of rural houses in So-yang Munhwa village by analyzing their floor plan shapes and space relations & elements. There were built 71 houses in that village, but it were possible to collect housing data, floor plans & general building records of 45 houses, from house register. By analyzing those data, findings were as follows : 1) Floor plan shapes of rural houses had a tendency to various type than simple types. 2) Room-Living-Room, 3 bay arrangement were very strong trends in those plans. 2) Public spaces, L.D.K(living dining kitchen) spaces, were centered in the floor plan of them. 3) Living space had an openness from entrance and DK(dining kitchen)spaces were separated from L.D.K. 4) Anbang(master bedroom) and living space were important, so two spaces were set to the south of floor plan and Anbang with a bathroom were often showed. 5) Utility and balcony/veranda spaces as a support space of kitchen were planned in rural houses.

  • PDF

Floor Impact Noise Measurement and Evaluation Method Using Impact Ball (임팩트 볼을 활용한 바닥충격음 측정 및 평가)

  • Jeon, Jin-Yong;Jeong, Jeong-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.10 s.103
    • /
    • pp.1160-1168
    • /
    • 2005
  • Floor impact noise isolation performance of reinforced concrete floors was investigated through new measurement method using impact bail. Strong impact force in Bow frequency band below 63 Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight Impact noise but heavy-weight impact noise measurement and evaluation using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

A Hydraulic Model Stydy of the Water-Intake Structure near River Mile 37 on the Missouri River

  • Byungman-Yoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1992.07a
    • /
    • pp.133-141
    • /
    • 1992
  • A three water-intake structure designed to built along the right bank of the Missouri River near Chesterfield, Missouri was model-tested at an undistorted scale of 1:5. Although the discharge capacity of each of six pumps to be installed is only 21,000 gpm, the model indicated strong flow circuation and unstable free-surface conditions as flow entered the two-pump bay through a narrow sluice opening at an angle. Strong free-surface vartices were also observed in the model. The sump modifications developed in the study included an array of baffle bars, a perforated plate, floor splitters, and floor-corner fillets. The solutions developed in this study could be applied to other pump sumps with multiple pump units.

  • PDF