• Title/Summary/Keyword: Stroboscopic analysis

Search Result 22, Processing Time 0.024 seconds

A Study on Quantitiative visualization of Vibration Mode Shape of Disk Brake by Using Stroboscopic ESPI (스트로보스코픽 전자 스페클 패턴 간섭법을 이용한 디스크 브레이크의 진동 모드의 정량적 가시화에 관한 연구)

  • 강영준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.97-104
    • /
    • 1999
  • Brake squeal noise has been a problem since the early days of motoring . It is important to obtain vibration mode shape for reduction of brake noise . Stroboscopic Electronic Speckle Pattern Interferometry is a very powerful measuring method for study of vibrating objects in static state compared with conventional methods because this method can give both resonance frequency and quantitative visualization of vibration mode shape at the same time. In this paper, we performed qualitative visualization and quantitative analysis of vibration mode shpae of disk brake by using stroboscopic ESPI and phase shifting method. The stroboscopic wavefronts are obtained by chopping continuous wave laser beam using acousto-optic modulator .Experiments were performed at the same constraint conditions as disk brake of the practical vehicle as far as possible. The experimental results of this paper show quantitative measurement of vibration mode shape and quantiative visualization of vibration amplitude of disk brake with 3D plotting.

  • PDF

Acoustic and Stroboscopic Characteristics of Normal Person's Voices with Advancing Age (연령증가에 따른 정상 노인의 음향분석학적 특징)

  • 진성민;권기환;강현국
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.1
    • /
    • pp.44-48
    • /
    • 1997
  • Anatomic and physiological changes of the larynx with advancing age result in morphologic changes of the vocal fold and reduced control of the phonatory mechanism in elderly individuals and are reflected in increased unstability of fundamental frequency (Fo). The purpose of this study is to increase current understanding of acoustic and stroboscopic characteristics of normal elderly persons voices. First, phonated /a/ vowel productions by 40 normal adults (20 to 40 years, 20 men and 20 women) and 40 normal elderly persons (60 to 80 years,20 men and 20 women) were analyzed, using CSL (model 4300B) acoustic analysis software, to obtain acoustic measures related to fundamental frequency stability nd vocal resonance characteristics. Second, stroboscopic images of the vocal fold behavior in all subjects were analyzed by experienced specialists. In the men, fundamental frequency variation (vFe) (p<0.01), jitter. (p<0.05), and shimmer (p<0.05) for the older group were significantly higher than the value for the adult group. In the stroboscopic findings, edema of vocal fold had a significant finding in aged men (15%). In the women, vFo (p<0.05), jitter (p<0.05), and noise to harmonic ratio (NHR) (p<0.05) for the older group were significantly higher than the value for e adult group and first formant frequency (F1) (p<0.01) and second formant frequency (F2) (p<0.01) for. the older group were significantly lower than the value for the adult group. In the stroboscopic findings, vocal fold atrophy had a significant finding in aged women (25%). Frequency stability, as reflected by vFo, jitter, shimmer, and NHR, decreases with advancing age in men and women and spectral analysis of phonated /a/ vowel productions reveals the lowering of the frequency of F1 and second F2 with advancing age, especially in aged women. Change in the mass of vocal folds, due to atrophy or edema, is considered to be the greatest factor in these acoustic changes.

  • PDF

Vibration Characteristics Analysis as Laser Welding Condition by ESPI (ESPI에 의한 레이저용접 조건에 따른 진동 특성 분석)

  • Kim K.S.;Jung H.C.;Baek S.K.;Lee Y.H.;You D.N.
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.349-353
    • /
    • 2005
  • This paper describes the variations of resonance frequencies and vibration mode shapes of laser welded cold rolled carbon steel plate(SCP1) induced by thermal loading during laser welding processing. The characteristics of those are analyzed with stroboscopic ESPI. Electronic speckle pattern interferometry (ESPI) that the electronic processes were added to SPI is one of the very powerful method in the experimental vibration analysis field. Stroboscopic ESPI to make it reliable are compared with theory and experimental method: Finite Element Method(FEM) and Scanning Laser Doppler Vibrometer(SLDV). The results of stroboscopic ESPI are well agreed with SLDV and also the comparison with theory give good agrement within $5\%$.

  • PDF

Development Non-contact Laser Measuring System for Vibration Analysis of Structures (구조물의 진동 해석을 위한 비접촉 레이저 계측 시스템 개발)

  • 정현철;김경석;최정석;김성식;강기수;정승택;최태호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.911-914
    • /
    • 2003
  • The non-contact laser measurement system what can be used for the vibration analysis of structures is discussed. There are few systems using laser speckle interferometer for vibration analysis. One of these systems is the Electronic Speckle Pattern Interferometer (ESPI). With ESPI system, one can obtain the vibration mode shape qualitatively and the maximum vibration amplitude quantitatively of the structure at each resonance frequency. In this paper, the phase-shifting ESPI system with stroboscopic illumination for measuring vibration mode shapes is constructed and the operating software is programmed. The results are compared with that of commercial ESPI system.

  • PDF

A study on the Quantification of vibration mode by ESPI using A.O Modulator (ESPI에서 AO변조기를 사용한 진동모드 정량화에 관한 연구)

  • 박낙규;유원재;안중근;강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.207-210
    • /
    • 2001
  • Recently, the study on the vibration analysis of machinery is greatly important and ESPI is widely used because of its many attractive features. Firstly, ESPI can be used to measure the vibration mode shape and the phase in real-time. Secondly, the conventional measuring methode, such as accelerometers, take much time to measure the whole field of object, but ESPI needs shorter time than other methods. Because ESPI is a field-inspection method. Thirdly, ESPI is a non-contact measuring system. ESPI does not have influence on the specimen. Beyond these features, there are several advantages in ESPI system. In this paper, the Stroboscopic ESPI system is described for measurement of a vibration mode shape. The Stroboscopic ESPI system had been used to visualize the vibration mode shape, in which EO(Electro-Optic)modulator was used to chop CW(Continuous Wavefront)laser. But it was not easy to control EO modulator and quantified the vibration amplitude and the phase of circular metal plate. At first, we found resonant frequency of the specimen by using time-averaged ESPI method. Nextly, the amplitudes of specimen were quantified by using Stroboscopic ESPI and we compare the results which were obtained in several chopping ratio.

  • PDF

Acoustic and Stroboscopic Characteristics in Clergies (목사들의 음성발성에 대한 음향분석학적 특징)

  • 진성민;박상욱;강현국;이경철;이용배;김보형
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.1
    • /
    • pp.47-52
    • /
    • 1998
  • Objectives : To compare the objective differences in voice quality and voice problems between clergies and normal male control group. Materials and Methods : The sustained vowel sound of 46 clergies and 40 normal persons were analyzed, using a videostroboscopy and acoustic analyzer. Together with these analyses, a questionnaire associated with current and past voice problems was handed over to the patients. Results : The most common symptom in subjective group was the voice fatigue. Stroboscopic findings in subjective group were as following 23 cases(50%) of pachydermia, 17 cases(37%) of phase difference, 12 cases(25%) of anterior-posterior contracture, 6 cases(13%) of vocal polyp and 3 cases(7%) of vocal nodule. The mean maximal phonation time in clergies was 17.8 seconds and in control group was 19 seconds. litter, pitch perturbation quotient and shimmer were significantly increased in subjective group than in control group(p<0.05), but there were no significant differences between two groups in fundamental frequency, vFo, amplitude perturbation quotient and noise to harmonic ratio. Conclusion : In the clergies using loud and forceful voice, vocal polyp and functional voice disorder findings were frequently noted in stroboscopic examination. litter and shimmer, reflecting the roughness of voice, were increased in acoustic analysis. Therefore, clergies, classified into untrained professional voice users, need professional career guidance and counseling.

  • PDF

Laryngo-stroboscopic Findings in Voice Disorders (음성질환의 후두스트로보스코피 소견)

  • 김영호;김광문;최홍식;홍원표
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1993.05a
    • /
    • pp.72-72
    • /
    • 1993
  • Among the various diagnostic methods for the voice disorders, video laryngo-stroboscopy is one of the most practical techniques for clinical examination of the vocal fold vibration. It provides valuable informations about the nature of vocal folds' vibration, the extent of pathologic change and data recording for analysis. To obtain the stroboscopic characteristics of several voice disorders, and apply those informations to the diagnosis and management of disorders, we reviewed the stroboscopic findings obtained from the patients with voice disorders at Voice laboratory, the Institute of Logopedics and Phoniatrics form April 1992 to March 1993.

  • PDF

Vibration Analysis of Loudspeaker by Using Electronic Speckle Pattern interferometry (전자 스페클 간섭계에 의한 스피커 진동 해석)

  • 강영준
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.1
    • /
    • pp.92-99
    • /
    • 1997
  • Nowadays, Electronic Speckle Pattern Interferometry is a well-established measuring technique with a wide range of industrial applications, particularly in the fields of deformation measurement and vibration analysis. Comparing with holographic interferometry, it has some attractive features, which are rapid recording and reconstruction, satisfiable automation etc. The Time-Average ESPI is used to provide vibration mode shape of an object whose vibration amplitude is given as a fringe pattern. Its merit is rapid and simple measurement for vibrating object. However, it is not possible to determine the direction of motions of a point on the object at any given time, because it does not give any information about the phase of vibration. But, Stroboscopic ESPI can measure the amplitude and phase of vibrating surface. In this paper, loudspeakers were tested by these two methods. As a result, we can assume that these techniques will be applied directly in the loudspeaker industry.

  • PDF

Vibration Analysis of Loudspeaker by Using Electronic Speckle Pattern Interferometry (전자 스페클 간섭계에 의한 스피커 진동 해석)

  • 김정규;노경완;강영준;김동우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.356-361
    • /
    • 1996
  • Nowadays, Electronic Speckle Pattern Interferometry is a well established measuring technique with a wide range of industrial applications, particularly in the fields of deformation measurement and vibration analysis. Comparing with holographic inteferometry, it has some attractive features, which are rapid recording and reconstruction, satisfiable automation etc. Time-average ESPI was used to provide vibration mode shape of an object whose vibration amplitude is given as a fringe pattern. However, it is not possible to determine the direction of motions of a point on the object at any given time, because time-average method does not give any information about the phase of vibration. A better technique is stroboscopic method which can measure the amplitude and phase of vibrating surface. In this paper, loudspeakers were tested by these two methods and the mode shape and amplitude of vibration were visualized. As measured results, we can assume that these techniques will be applied directly in the loudspeaker industry.

  • PDF

Vibration Mode Shape Changed by Phase Angle in Vibration Testing Using Phase-Shifting ESPI (위상이동 ESPI를 이용한 진동실험에서 위상각에 따른 진동모드 형상의 변화)

  • 정현철;김경석;양승필;장호섭;박찬주;조영학;김종수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.443-446
    • /
    • 2003
  • The vibration mode shape changed by the phase angle that can be controlled by phase-shifting ESPI system is discussed. For the phase-shifting ESPI experiment the stroboscopic illumination by using AOM(Acousto-Optic Modulator) is needed, and the initial phase angle can be adjusted by the program. The vibration mode shape is changed when the initial phase angle is changed. We examined the vibration mode shape change due to the initial phase angle change at each resonance frequency. Through this study, we found that in the vibration testing using phase-shilling ESPI the vibration mode shape is improved in the quality by adjusting exact phase angle and the error of the quantitative vibration analysis can be reduced.

  • PDF