• 제목/요약/키워드: Stress Profile

검색결과 689건 처리시간 0.026초

이론적 열유동 및 랜덤 진동 해석을 적용한 EPS 보냉용기의 포장설계 (Packaging Design of EPS Cooling Box by Theoretical Heat Flow and Random Vibration Analysis)

  • 김수현;박상훈;이민아;정현모
    • 한국포장학회지
    • /
    • 제27권3호
    • /
    • pp.175-180
    • /
    • 2021
  • Although it has recently been regulated for use as an eco-friendly policy in Korea, the use of EPS (Expanded Polystyrene) cooling boxes, which are used as cold chain delivery insulation boxes for fresh agricultural and livestock products, is also increasing rapidly as e-commerce logistics such as delivery have increased rapidly due to COVID-19. Studies were conducted to optimize the EPS cooling container through internal air heat flow of CFD (Computational Fluid Dynamics) analysis and FEM (Finite Element Method) random vibration analysis using domestic PSD (Power Spectral Density) profile of the EPS cooling box to which the refrigerant is applied in this study. In the analysis of the internal air heat flow by the refrigerant in the EPS cooling box, the application of vertical protrusions inside was excellent in volume heat flow and internal air temperature distribution. In addition, as a result of random vibration analysis, the internal vertical protrusion gives the rigid effect of the cooling box, so that displacement and stress generation due to vibration during transport are smaller than that of a general cooling container without protrusion. By utilizing the resonance point (frequency) of the EPS cooling box derived by the Model analysis of ANSYS Software, it can be applied to the insulation and cushion packaging design of the EPS product line, which is widely used as insulation and cushion materials.

웨지 와이어를 이용한 선박용 필터 스크린 제작을 위한 최적 지지 위치 및 안정성 판단 (Determination of Optimal Support Position and Stability for Manufacturing Filter Screen for Ships Using Wedge Wires)

  • 손인수;서병석
    • 한국산업융합학회 논문집
    • /
    • 제25권2_2호
    • /
    • pp.263-269
    • /
    • 2022
  • In this study, the optimal support position determination and stability determination of the wedge wire screen were performed for the production of the wedge wire filter screen with improved mesh screen. In order to manufacture a filter screen using a wedge wire, the support rod wedge wire is first installed according to the filtering capacity, and then spot welding is performed while rotating the profile wire. In the existing manufacturing method, it was manufactured using a 3m rod wedge wire and then cut according to dimensions, but it required the manufacture of a 6m cylindrical screen. Due to the increase in wedge wire length, it is difficult to manufacture stress concentration at sagging and fixed positions. In order to shorten the time of analysis, a single wedge wire was applied instead of a plurality of wedge wires. The reliability and validity of the interpretation were presented and the results were derived. After selecting the support point at the 2m position, structural analysis was performed on the entire filter screen to confirm stability.The purpose of this study is to identify the maximum deflection of the wire for the production of a 6m wedge wire screen and secure design basic data so that it can work safely through optimal support.

The Effect of an Empowerment Program on the Health-promoting Behaviors of Iranian Women Workers: A Randomized Controlled Trial

  • Noori, Fatemeh;Behboodimoghadam, Zahra;Haghani, Shima;Pashaeypoor, Shahzad
    • Journal of Preventive Medicine and Public Health
    • /
    • 제54권4호
    • /
    • pp.275-283
    • /
    • 2021
  • Objectives: The workplace is an ideal place for encouraging health-promoting behaviors. Therefore, the aim of the present study was to determine the effect of an empowerment program on the health-promoting behaviors of women workers. Methods: This randomized clinical trial was conducted with 80 women workers employed at a food packaging facility in 2020. The subjects were selected using convenience sampling and were classified into intervention and control groups using block randomization. An empowerment program for women workers was conducted across 6 sessions based on an empowerment model. Data collection tools included a demographic questionnaire and the Health Promoting Lifestyle Profile-II, which participants completed both before the program and 8 weeks after the last session. Data analysis was performed in SPSS version 16 using descriptive analysis and inferential statistics. Results: There were no significant differences between the 2 groups in various health-promoting behaviors before the program. However, the intervention group's scores for nutrition (34.92±1.09 vs. 27.87±4.23), physical activity (24.40±2.94 vs. 17.40±5.03), stress management (26.35±2.60 vs. 23.05±4.27), spiritual growth (34.02±3.00 vs. 30.22±5.40), interpersonal relationships (30.82±2.38 vs. 27.60±4.61), and health responsibility (31.60±2.71 vs. 28.22±4.59) were significantly higher than the control group's 8 weeks after the program had ended. Moreover, there was a significant difference in the total score of health-promoting behaviors for the intervention group compared to the control group (179.00±9.22 vs. 151.42±20.25, p=0.001). Conclusions: An empowerment program for women workers led to significant improvements in the health-promoting behaviors of the participants. Similar programs can ultimately improve women's health in the workplace.

Psychological and Physiological Responses to Different Views through a Window in Apartment Complexes

  • Jeon, Seong Min;Kang, Minji;Kim, Su Jin;Kim, Yong Jin;Choi, Hyo Bhin;Lee, Juyoung
    • 인간식물환경학회지
    • /
    • 제24권5호
    • /
    • pp.545-550
    • /
    • 2021
  • Background and objective: With increasing land use intensity in urban areas, apartment buildings have been recognized as a typical type of urban residence. In this study, the impacts of different views through a window on health-related responses were investigated using psychological and physiological parameters. Methods: Photos of three different types of views taken on low (2-12 m), middle (28-35 m), and high (over 54 m) floors of dense apartment building areas were used as visual stimuli. Twenty-two healthy adults participated in the indoor experiment. Semantic differential methods and profile of mood states were used as psychological tools. Autonomic nervous activity was evaluated using blood pressures, pulse rate and heart rate variability (HRV). Results: Analytic data showed different characteristics of psychological and physiological outcomes in three different apartment views. In the analysis of psychological parameters, significantly negative responses to the views on middle floors were found in the subscales of tension-anxiety and anger-hostility, compared to low floors. Significantly positive scores in the subscale of vigor were found on low floors with abundance of vegetation and high floors with a view of the sky. A significantly increased value of HF was found on low floors (2,294.96 ± 169.79), compared to the middle(1,553.45 ± 84.66) and high (1,523.02 ± 70.49) floors. Despite the high scores in openness and vigor, high floor views showed significantly higher LF/HF values (1.83 ± 0.09), the indicator of the sympathetic nervous system, than low (1.30 ± 0.07) and middle floor views (1.34 ± 0.06), which might be related to the unconscious fear of heights. Conclusion: Views from different heights in an apartment building can affect the psychological states of residents. Green space through the window may have a positive health outcome by reducing physiological stress.

A systematic review of the biological mechanisms linking physical activity and breast cancer

  • Hong, Bok Sil;Lee, Kang Pa
    • 운동영양학회지
    • /
    • 제24권3호
    • /
    • pp.25-31
    • /
    • 2020
  • [Purpose] Epidemiological evidence has shown that leisure-time physical activity and structured exercise before and after breast cancer diagnosis contribute to reducing the risk of breast cancer recurrence and mortality. Thus, in this review, we aimed to summarize the physical activity-dependent regulation of systemic factors to understand the biological and molecular mechanisms involved in the initiation, progression, and survival of breast cancer. [Methods] We systematically reviewed the studies on 1) the relationship between physical activity and the risk of breast cancer, and 2) various systemic factors induced by physical activity and exercise that are potentially linked to breast cancer outcomes. To perform this literature review, PubMed database was searched using the terms "Physical activity OR exercise" and "breast cancer", until August 5th, 2020; then, we reviewed those articles related to biological mechanisms after examining the resulting search list. [Results] There is strong evidence that physical activity reduces the risk of breast cancer, and the protective effect of physical activity on breast cancer has been achieved by long-term regulation of various circulatory factors, such as sex hormones, metabolic hormones, inflammatory factors, adipokines, and myokines. In addition, physical activity substantially alters wholebody homeostasis by affecting numerous other factors, including plasma metabolites, reactive oxygen species, and microRNAs as well as exosomes and gut microbiota profile, and thereby every cell and organ in the whole body might be ultimately affected by the biological perturbation induced by physical activity and exercise. [Conclusion] The understanding of integrative mechanisms will enhance how physical activity can ultimately influence the risk and prognosis of various cancers, including breast cancer. Furthermore, physical activity could be considered an efficacious non-pharmacological therapy, and the promotion of physical activity is probably an effective strategy in primary cancer prevention.

Modelling headed stud shear connectors of steel-concrete pushout tests with PCHCS and concrete topping

  • Lucas Mognon Santiago Prates;Felipe Piana Vendramell Ferreira;Alexandre Rossi;Carlos Humberto Martins
    • Steel and Composite Structures
    • /
    • 제46권4호
    • /
    • pp.451-469
    • /
    • 2023
  • The use of precast hollow-core slabs (PCHCS) in civil construction has been increasing due to the speed of execution and reduction in the weight of flooring systems. However, in the literature there are no studies that present a finite element model (FEM) to predict the load-slip relationship behavior of pushout tests, considering headed stud shear connector and PCHCS placed at the upper flange of the downstand steel profile. Thus, the present paper aims to develop a FEM, which is based on tests to fill this gap. For this task, geometrical non-linear analyses are carried out in the ABAQUS software. The FEM is calibrated by sensitivity analyses, considering different types of analysis, the friction coefficient at the steel-concrete interface, as well as the constitutive model of the headed stud shear connector. Subsequently, a parametric study is performed to assess the influence of the number of connector lines, type of filling and height of the PCHCS. The results are compared with analytical models that predict the headed stud resistance. In total, 158 finite element models are processed. It was concluded that the dynamic implicit analysis (quasi-static) showed better convergence of the equilibrium trajectory when compared to the static analysis, such as arc-length method. The friction coefficient value of 0.5 was indicated to predict the load-slip relationship behavior of all models investigated. The headed stud shear connector rupture was verified for the constitutive model capable of representing the fracture in the stress-strain relationship. Regarding the number of connector lines, there was an average increase of 108% in the resistance of the structure for models with two lines of connectors compared to the use of only one. The type of filling of the hollow core slab that presented the best results was the partial filling. Finally, the greater the height of the PCHCS, the greater the resistance of the headed stud.

Beer-Lambert 법칙을 적용한 레이저 열원 프로파일 모델링 및 레이저무기용 반사경의 열변형 해석을 통한 구조-열-광학 성능 연구 (A Study on Structural-Thermal-Optical Performance through Laser Heat Source Profile Modeling Using Beer-Lambert's Law and Thermal Deformation Analysis of the Mirror for Laser Weapon System)

  • 홍대기
    • 항공우주시스템공학회지
    • /
    • 제17권4호
    • /
    • pp.18-27
    • /
    • 2023
  • 본 논문에서는 열해석의 하중조건으로 레이저 열원을 설정하여 반사경의 구조-열-광학 성능 분석을 수행하였다. 레이저 열원 모델은 가우시안 빔을 바탕으로 반투명한 소재를 고려한 Beer-Lambert 법칙을 적용하여 하중조건으로 선정하였으며, 반사경만의 성능 분석을 위하여 기구부는 고려하지 않았다. 열변형해석을 수행하여 반사경 표면의 온도 변화로 인한 열응력과 열변형 데이터를 얻었다. 열변형에 의한 반사경 표면의 변위 데이터를 Zernike 다항식에 피팅하여 파면오차를 계산하였으며, 이를 통해 고에너지 레이저가 반사경으로 입사될 때 반사경의 광학 성능을 예측할 수 있었다.

Force Assessment of Thermoformed and Direct-printed Aligners in a Lingual Bodily Movement of a Central Incisor Over Time: A 14-day In Vitro Study

  • Mary Linda Remley;Gabriel Ferreira Pessoa Carvalho Miranda ;Brent Bankhead;Julie McCray;Ki Beom Kim
    • Journal of Korean Dental Science
    • /
    • 제16권1호
    • /
    • pp.23-34
    • /
    • 2023
  • Purpose: This study aims to investigate the force delivery profile of thermoformed aligners (TFA) compared with direct-printed aligners (DPA) and to explore the effect of different activation amounts on forces and moments of respective groups. A secondary objective is to observe the amount of stress relaxation that occurs over the 7~14 days when aligners are maintained in a simulated intraoral environment. Materials and Methods: An in vitro setup was created to quantify forces and moments. It consisted of a three dimensional-printed base plate and segmented maxillary teeth, placed in a semi-enclosed chamber to maintain a temperature of 37℃. Ninety clear aligners were divided into nine groups of ten aligners each based on material types (Zendura, ATMOS, TC-85) and activation amounts. Aligners were created with 0.00, 0.25- and 0.50-mm activations for lingual bodily movement of the upper left central incisor and kept on models in the "stressed" position in a 37℃ water bath. Three force components acting on the upper left lateral incisor, upper left central incisor, and upper right central incisor were measured for each time point, beginning from the initial baseline measurement, 8 hours, 16 hours, 24 hours, 2 days, 3 days, 4 days, 5 days, 6 days, 7 days, and lastly, 14 days. Result: TC-85 aligners in every activation group showed less force on teeth than Zendura and ATMOS. Significant force levels from 0.0 mm activation were present and stayed consistent over the course of 14 days. Comparisons made for baseline measurements to 7-days and 14-days showed statistically significant change from the baseline force level. Conclusion: TC-85 aligners demonstrated lower, more consistent forces with fewer side effects. Aligners can generate forces even when no activation is programmed. No major decreases in force levels over time were observed; the intra-oral clinical simulated environment and length of observation time could contribute to this.

Effects of Pretreatment for Controlling Internal Water Transport Direction on Moisture Content Profile and Drying Defects in Large-Cross-Section Red Pine Round Timber during Kiln Drying

  • Bat-Uchral BATJARGAL;Taekyeong LEE;Myungsik CHO;Chang-Jin LEE;Hwanmyeong YEO
    • Journal of the Korean Wood Science and Technology
    • /
    • 제51권6호
    • /
    • pp.493-508
    • /
    • 2023
  • Round timber materials of 600 mm length, cut from large-cross-section round timber of red pine (Pinus densiflora S. et Z.) of 450 mm width and 4.2 m length, were prepared as the target of kiln drying in this study. After treating the target materials through end sealing (ES), end sealing - kerfing (ES-K), lateral sealing - end sealing - boring (LS-ES-B), or lateral sealing - partial end sealing (LS-PES), the effects of the treatment on the incidence of drying defects were determined. The target materials with exposed lateral surface and sealed cross surface were steamed at the initial temperature of 65℃ above the official pest control temperature of 56℃, followed by kiln drying toward the final temperature of 75℃. The target materials with sealed lateral surfaces, on the other hand, were dried at the initial temperature of 90℃ at almost the maximum temperature of conventional kiln drying, as there is no risk of early check formation caused by surface moisture evaporation. The final temperature was set at approximately 100℃. The drying time, taken for the target materials with initial moisture content of 70%-80% to reach the target moisture content of 19%, varied across treatment conditions. The measured drying time was 1,146 hours (approximately 48 days) for the timber with sealed cross surface and 745 hours (approximately 31 days) for the timber with sealed lateral surface, until the moisture content reached the target level. The formation of surface checks could not be prevented in the control and ES groups, but a definite preventive effect was obtained for the LS-ES-B and LS-PES groups.

관동맥질환의 진단을 위한 아데노신 Tc-99m sestaMIBI SPECT의 재현성 (Reproducibility of Adenosine Tc-99m sestaMIBI SPECT for the Diagnosis of Coronary Artery Disease)

  • 이덕영;배진호;이상우;천경아;유정수;안병철;하정희;채성철;이규보;이재태
    • 대한핵의학회지
    • /
    • 제39권6호
    • /
    • pp.473-480
    • /
    • 2005
  • 목적: 아데노신 부하 Tc-99m MIBI SPECT는 관동맥질환의 진단, 예후 평가, 치료 방침의 설정, 치료 효과 판정 및 경과 관찰에 유용성이 있다고 알려져 있다. 치료 효과 판정 및 치료 방침 설정을 위해서는 검사 방법의 재현성이 높아야 한다. 본 연구는 아데노신 부하 Tc-99m MIBI SPECT의 재현 성능을 평가하기 위하여 동일인에서 2회 연속적으로 시행한 아데노신 부하 Tc-99m MIBI SPECT에서 약물주사에 따른 혈역학적 변화와 부작용의 빈도, 영상에 나타난 심근분절의 방사능섭취 정도의 차이를 알아 보고자 하였다. 대상 및 방법: 관동맥질환이 의심되거나 관동맥질환으로 진단된 후 추적검사를 위하여 아데노신 부하 Tc-99m MIBT SPECT를 시행한 30명의 환자를 대상으로 2-11 일(평균: 4.1 일)의 간격으로 검사를 반복하였다. 관류영상의 육안적 판독은 좌심실의 단층 영상을 18분절로 구분하여, 섭취 정도에 따라 4등급으로 분류하였고, 관류 정도의 평가는 2명의 핵의학 전공의사가 각각 평가한 후 일치하지 않은 경우에는 두 판독자 간에 토의로 합의된 소견으로 비교하였다. 결과: 아데노신 주사에 따른 수축기혈압, 이완기 혈압 및 맥박 수의 변화는 두 검사 사이에 유의한 차이가 없었고, 두 번의 검사를 시행하는 동안 검사를 중지하거나 부작용 치료를 위한 처치를 받아야 만큼 중독한 부작용의 발생은 없었다. 관류점수상 540분절 중 439분절에서 완전하게 일치하였고(일치도 81.3%, tau B index 0.73%), 1점 차이(97분절, 18%), 2점 차이(4분절, 0.7%)있었으나 3점 이상의 차이가 있은 경우는 없었다. 두 검사에서 측정된 관류결손의 범위와 중증도점수 사이에는 각각 $\gamma$-값 0.982와0.965의 높은 양의 상관성을 나타내었다(p<0.001, respectively). 결론: 연속적으로 2회 시행한 아데노신 부하 Tc-99m MIBI SPECT는 부하에 따른 혈역학적 변화 및 부작용의 발생이 유사하였고, 심근분절의 관류상태의 시각적 평가 및 관류결손의 정량적 판정에서 매우 높은 재현성을 보여주었다. 그러므로 아데노신 Tc-99m MIBI SPECT는 관동맥질환이 의심되거나 관동맥질환으로 진단된 환자에서 약물치료나 중재적 시술 또는 외과적 수술 치료 후 심근관류상태의 경시적 변화를 평가하는데 유용하게 이용될 수 있을 것이라 판단된다.