• 제목/요약/키워드: Strengthening Plate

검색결과 256건 처리시간 0.02초

Effects of a 12-week Combined Exercise Program on Gait Parameters in Elderly Women with Osteoarthritis

  • Lee, Jin
    • 한국운동역학회지
    • /
    • 제28권4호
    • /
    • pp.227-236
    • /
    • 2018
  • Objective: The purpose of this study was to investigate the effects of a 12-week combined exercise program on gait parameters in elderly women with osteoarthritis. Method: The subjects of this study were 11 elderly women (age: $67.09{\pm}2.47$, height: $157.35{\pm}4.30cm$, weight: $62.49{\pm}6.36kg$) with knee osteoarthritis. The combined exercise program of this study was divided into aerobic exercise and lower extremity strengthening exercises. The exercises were performed for 60 minutes per session, three times a week, for a total of 12 weeks. The maximum joint moments of the hip, knee, and ankle joints with walking were obtained with 8-3D cameras (MX-T20, Vicon, USA) and 2-force plate (AMTI OR6-7-400, AMTI, USA). SPSS Windows version 23.0 was used for statistical analysis. A paired t-test was used for pre-post comparison. An alpha level of .05 was utilized in all tests. Results: The maximum extension moment was significantly higher in the hip joint after P1 on the X axis. The maximum joint moment of P3 in extension was statistically significantly lower after intervention. On the Z axis, the maximum joint moment was significantly lower after the exercise intervention at P3. There was a statistically significant increase in the extension moment of the left and right knee joints in the X axis after exercise intervention. In the right ankle joint, P1 (plantar flexion moment) showed a statistically significant high moment after exercise intervention. Conclusion: These results suggest that combined exercise, including lower limb and aerobic exercise, may have a positive effect on mobility and walking moments in patients with osteoarthritis of the knee.

중국 태안시 다이웨구 학교급식소의 시설·기구·환경 위생관리 실태 (Status of Facilities, Equipment, and Environmental Hygiene Management of School Foodservices in Daiyue-district, Taian-city, China)

  • 정효하;문혜경
    • 급식외식위생학회지
    • /
    • 제2권2호
    • /
    • pp.59-66
    • /
    • 2021
  • The results of the inspection based on the sanitation checklist and the measurement of refrigerator/freezer temperature, illuminance, and ATP were conducted at 12 school foodservices in Daiyue-district, Taian-city, Shandong Province, China, at the same time, and the results were as follows. Five items of 'Use sterilized cutting boards', 'Use sterilized knives', 'Use worktable after sterilization', 'Use sink after sterilization', 'Sterilize the interior/exterior of the refrigerator regularly' in the checklist inspection were found not to be performed (0%). Two items of 'Disinfect hands after washing', 'Equipped with hand sterilizer' and 'Sterilize the kitchen areas regularly' were investigated as being performed only in one foodservice (8%). The average illuminance of the receiving stand were 373.08±106.35 Lux, 8% when the standard (540 Lux or higher) was complied with, the average refrigerator temperature were 7.06±0.82℃, 38.9% when the standard (-2 to 5℃) was observed 8% of cases complying with the standard (below -18℃) at -8.56±0.76℃ were investigated. As a result of ATP measurement, the surfaces of knife edge, cutting board, refrigerator door handle, worktable, and sink, which are not sterilized at all, were not suitable (accept ratio 0%), sterilized food plate (accept ratio 54.2%) and utensil for preserved food (accept ratio 75%) had a relatively high accept ratio. China's hygiene regulations should be revised in the direction of strengthening disinfection practices for facilities, equipment, and the environment, and hygiene measures such as education on disinfection and preparation of economical disinfection methods should be established.

Bond behavior between concrete and prefabricated Ultra High-Performance Fiber-Reinforced Concrete (UHPFRC) plates

  • Mansour, Walid;Sakr, Mohammed A.;Seleemah, Ayman A.;Tayeh, Bassam A.;Khalifa, Tarek M.
    • Structural Engineering and Mechanics
    • /
    • 제81권3호
    • /
    • pp.305-316
    • /
    • 2022
  • Externally bonded ultrahigh performance fiber-reinforced concrete (UHPFRC) is commonly used as a strengthening material for reinforced concrete (RC) structures. This study reports the results of an experimental program investigating the bonding behavior between concrete and prefabricated UHPFRC plates. The overall experimental program is consisting of five RC specimens, which are strengthened using the different lengths and widths of prefabricated UHPFRC plates. These specimens were analyzed using the pull-pull double-shear test. The performance of each strengthened specimen is presented, discussed and compared in terms of failure mode, maximum load, load-slip relationship, fracture energy and strain distribution. Specimen C-25-160-300 which bonded along the whole width of 160 mm recorded the highest maximum load (109.2 kN) among all the analysed specimens. Moreover, a 3D numerical finite element model (FEM) is proposed to simulate the bond behavior between concrete and UHPFRC plates. Moreover, this study reviews the analytical models that can predict the relationship between the maximum bond stress and slip for strengthened concrete elements. The proposed FEM is verified against the experimental program and then used to test 36 RC specimens strengthened with prefabricated UHPFRC plates with different concrete grades and UHPFRC plate widths. The obtained results together with the review of analytical models helped in the formation of a design equation for estimating the bond stress between concrete and prefabricated UHPFRC plates.

콘크리트채움 U형합성보-H형강기둥 십자형 합성접합부의 내진성능 (Cyclic Seismic Testing of Cruciform Concrete-Filled U-Shape Steel Beam-to-H Column Composite Connections)

  • 박창희;이철호;박홍근;황현종;이창남;김형섭;김성배
    • 한국강구조학회 논문집
    • /
    • 제23권4호
    • /
    • pp.503-514
    • /
    • 2011
  • 본 연구에서는 콘크리트채움 U형 합성보와 H형강 기둥 십자형 합성접합부의 내진상세를 제시하고, 2개의 실물대 실험체를 설계/제작하여 강구조내진기준의 표준실험절차에 따라 내진성능을 평가하였다. 주요 실험체 구성요소는 춤 450mm(실험체 A) 및 550mm(실험체 B) U형 강재보, 두께 165mm의 골데크플레이트 위에 타설된 콘크리트 바닥슬래브, U형보의 완전합성작용을 하기 위한 전단스터드, 부모멘트 전달을 위한 4개의 주철근 및 H형강 기둥에 정착을 위한 용접커플러 그리고 접합부 보강을 위한 보강판으로 구성된다. 순수 강재 보-기둥 접합부와 상이한 U형 합성접합부의 독특한 특성을 고려하여, 지진하중 하에서 내진성능에 결정적 영향을 미치는 보-기둥 접합부의 용접부 취성파단, 강판의 국부좌굴, 주철근의 휨좌굴, 콘크리트 압괴 등의 한계상태가 적절히 제어되도록 실험체를 설계하였다. 강구조내진기준의 지진하중 가력프로그램에 따른 실험결과, 설계에서 의도한 바와 같이 여러 한계상태가 적절히 제어되어 실험체 A 및 B는 각각 6% 및 6.8% 라디안에 이르는 매우 뛰어난 층간변형능력을 발휘하였다. 이는 특수모멘트골조에 요구되는 4% 라디안 수준을 충분히 상회하는 만족스런 층간변형능력이다. 특히 접합부 강화전략에 의해 제안된 합성접합부 상세는 설계에서 의도한 것과 같이 소성힌지를 보강단부로서 밀어냄으로서 취약할 수 있는 보-기둥 용접접합부를 효과적으로 보호하였다. 실험체 A의 최종 파괴모드는 6.0% 층간변위에서 발생한 보강단부에 인접한 냉간성형 코너부의 점진적 저사이클피로에 의한 하부플랜지의 파단에 의해 발생하였다. 한편, 실험체 B는 8.0%의 높은 수준의 층간변위에서 발생한 볼트이음부 파단에 의해 내력을 상실하였다.

지속하중을 받는 탄소섬유판의 장기 거동 (Long-Term Behavior of CFRP Strips under Sustained Loads)

  • 유영찬;최기선;김긍환
    • 콘크리트학회논문집
    • /
    • 제21권2호
    • /
    • pp.139-146
    • /
    • 2009
  • 본 연구에서는 외부프리스트레스 탄소섬유판에 의한 보강기술에서 긴장력을 포함하는 지속하중이 작용하였을 때의 장기거동을 평가하기 위한 실험연구를 수행하였다. 지속하중 도입을 위한 실험계획은 탄소섬유판에 직접 인장력을 도입하는 직접 지속하중 방식과 휨 실험체를 통한 휨 지속하중으로 구분하여 실시하였다. 직접 지속하중에 의한 실험은 탄소섬유판의 종류별로 약 700일에 걸쳐 실시하여 탄소섬유판의 장기 크리프/릴렉세이션 등의 변형을 주로 평가하였으며, 휨 지속하중 실험에서는 탄소섬유판의 정착시 정착장치에서의 슬립량을 주로 평가하기 위해 약 90일 간으로 수행되었다. 일방향 탄소섬유판에 대한 2년간의 지속하중 실험 결과에 의하면, 탄소섬유판의 크리프나 릴렉세이션과 같은 재료자체의 변형 및 정착장치에서의 슬립에 기인한 응력손실은 적은 것으로 나타났다. 그러나, 강판매입형 탄소섬유판은 강판의 항복변형률을 초과하여 도입된 긴장력으로 인하여 재료 자체의 변형에 의한 자체 응력손실이 발생되었으므로 이에 대한 보완이 필요한 것으로 판단된다. 아울러, 탄소섬유판의 정착과정에 발생되는 긴장력의 즉시 손실량은 응력도입 초기의 약 10% 정도이므로 프리스트레스의 도입시에는 이를 고려하여 긴장력을 결정할 필요성이 있을 것으로 판단된다.

척추안정화 운동이 민간 경호.경비원들의 허리통증에 미치는 영향 (Effects of spinal stabilization training on Chronic Low Back Pain in Private Guard and Security)

  • 김성호;이완희
    • 시큐리티연구
    • /
    • 제20호
    • /
    • pp.71-93
    • /
    • 2009
  • 이 연구는 만성요통을 가진 민간 경호 경비원들을 대상으로 척추안정화 운동을 실시하여, 허리통증, 일상생활제한, 척추심부근육의 근단면적 변화에 미치는 영향을 비교 분석하고자 실시하였다. 연구 대상자는 서울 경기 지역 경호 경비업체에 종사하는 직원 중 만성요통(3개월 이상)을 호소하는 42명을 대상으로 일반적인 척추강화운동그룹, 척추안정화 운동 그룹으로 21명씩 무선 할당하여, 주 3회, 10주간 운동을 실시하였다. 실험 전 후 설문지를 이용하여 허리통증과 요통장애지수를 조사하였으며, 컴퓨터 단층촬영(CT)을 실시하여 다열근과 대요근의 근단면적을 측정하였으며, 실험 전 후 변화된 값을 비교 측정하여 다음과 같은 결과를 얻었다. 1. 통증강도와 요통장애지수는 두 그룹 모두 통계학적으로 유의하게 감소한 것으로 나타났다(p<0.01). 그룹 간 비교에서는 척추안정화 운동그룹이 일반적인 척추강화 운동그룹에 비하여 통증 및 일상생활제한의 감소폭이 더 큰 것으로 나타났다(p<0.05). 2. 두 그룹 간 다열근과 대요근의 근단면적 변화는 척추안정화 운동그룹이 일반적인 척추강화 운동그룹 보다 통계학적으로 유의하게 증가하였다(p<0.05). 이 연구 결과를 볼 때, 만성요통을 호소하는 민간 경호 경비원들을 대상으로 다열근과 대요근과 같은 심부근육 강화에 초점을 둔 척추안정화 운동프로그램이 일반적인 척추강화 운동프로그램 보다 통증 및 요통장애지수 감소와 심부근육의 근력 증가(근단면적)에 더 효과적인 것으로 나타났다. 따라서 척추안정화 운동이 만성요통 민간 경호 경비원들의 요통감소와 기능 회복에 효과적이라고 할 수 있겠다.

  • PDF