• Title/Summary/Keyword: Strength1 Assessment

Search Result 494, Processing Time 0.025 seconds

Assessment of Strength Characteristics of Al 2024 ECAP Metal Using Small Punch Testing (소형펀치 시험법을 이용한 Al 2024 ECAP 재료의 강도특성 평가)

  • Ma Young Wha;Choi Jeong Woo;Kim Seon Hwa;Yoon Kee Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.1 s.244
    • /
    • pp.8-17
    • /
    • 2006
  • When subjected to severe shear deformation by ECAP, microstructure of Al2024 becomes extremely refined. To measure the strength of that, small punch(SP) testing method was adopted as a substitute for the conventional uniaxial tensile testing because the size of material processed by ECAP were limited to ${\psi}12\;mm$ in transverse direction. SP tests were performed with specimens in longitudinal and transverse directions of Al2024 ECAP metal. For comparing the strength values with those assessed by SP tests, uniaxial tensile tests were also conducted with specimens in longitudinal direction. Failure surfaces of the tested SP specimens showed that failure mode was shear deformation and Al 2024 ECAP metal has an anisotropy in strength. Thus, conventional equations proposed for assessing the strength characteristics were improper to assess those of Al2024 ECAP metal. In this paper a way of assessing the strength of Al 2024 ECAP metal was proposed and was proven to be effective.

Fatigue Strength Assessment of TLP Tendon Porch Using API 2W Gr.50 Steel

  • Im, Sung-Woo;Seo, Young-Seok;Lee, Joo-Sung
    • Journal of Ship and Ocean Technology
    • /
    • v.11 no.1
    • /
    • pp.25-35
    • /
    • 2007
  • This paper is concerned with the fatigue strength assessment of tendon porch found which is categorized as the special structural member in TLP. Large-scale tendon porch specimens have been designed and fabricated with API 2W Gr.50 steel recently produced by POSCO. Fatigue test has been carried out for three tendon porch specimens under various load level. Fatigue strength has been evaluated based on the nominal stress range and the results are compared with the fatigue design curve of DnV RP-C203. From the present experimental study, it has been found that the porch specimens satisfy the fatigue design rule although test was carried out under the positive stress ratio. It can be, therefore, said that the API 2W steel produced by POSCO possess sufficient fatigue strength.

A Study of Effective Collection of Public Opinion on Environmental Impact Assessment (환경영향평가상의 효율성 주민의견 수렴에 관한 연구)

  • Yoo, Heon-Seok;Joo, Yong-Joon;Jeong, Seong-Hoon
    • Journal of Environmental Impact Assessment
    • /
    • v.11 no.4
    • /
    • pp.311-319
    • /
    • 2002
  • Procedures to establish well-balanced development and effectiveness of environmental impact assessment need include various stakeholder's participation in writing and reviewing document of environmental impact assessment, collecting public opinion, and post monitoring. Accordingly, to encourage effective and efficient collection of resident's opinion analyze present conditions and problems and suggest institutional and politic alternative proposals of it. This study resulted in following conclusions. In institutional aspects, (1) Proposal for drafting document of environmental impact assessment (2) Composition of committee for collecting and regulating stakeholder's opinion (3) Width of civil participation scale. In politic aspects, (1) Use of local community (2) Guide of local information from local society and environmental specialist (3) Understandable document and data of environmental impact assessment (4) Strength of roles and duties of local government.

Assessment of Residual Tensile Strength on Cast Iron Water Pipes (주철관의 잔존강도 평가에 관한 연구)

  • Bae, Cheol-Ho;Kim, Ju-Hwan;Kim, Jeong-Hyun;Hong, Seong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.867-874
    • /
    • 2006
  • The goal of this study is to assess cast iron pipes (CIPs) and present a residual tensile strength prediction model using pit characteristics and fracture toughness. The results is the followings. First, average pit depths of collected CIPs were in the range from 0.63 to 6.49 mm, loss of tensile strength compared with net metallic tensile strength were from -7.06 to 67.91 percent. Second, fracture toughness for NS-CR-1, NS-CR-2, and NS(2)-CR-1 were in the range from 62.85 to $89.39kgf/mm^2{\sqrt{mm}}$, and average of those samples was $73.69kgf/mm^2{\sqrt{mm}}$ on CIPs. Third, the models developed in this study by using pit characteristics and fracture toughness showed a little good correlation for measured residual tensile strength, and the results will be expected to help for water utilities to manage CIPs in the aspect of rehabilitation and assessment of structural safety on CIPs.

Application of internet of things for structural assessment of concrete structures: Approach via experimental study

  • D. Jegatheeswaran;P. Ashokkumar
    • Smart Structures and Systems
    • /
    • v.31 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • Assessment of the compressive strength of concrete plays a major role during formwork removal and in the prestressing process. In concrete, temperature changes occur due to hydration which is an influencing factor that decides the compressive strength of concrete. Many methods are available to find the compressive strength of concrete, but the maturity method has the advantage of prognosticating strength without destruction. The temperature-time factor is found using a LM35 temperature sensor through the IoT technique. An experimental investigation was carried out with 56 concrete cubes, where 35 cubes were for obtaining the compressive strength of concrete using a universal testing machine while 21 concrete cubes monitored concrete's temperature by embedding a temperature sensor in each grade of M25, M30, M35, and M40 concrete. The mathematical prediction model equation was developed based on the temperature-time factor during the early age compressive strength on the 1st, 2nd, 3rd and 7th days in the M25, M30, M35, and M40 grades of concrete with their temperature. The 14th, 21st and 28th day's compressive strength was predicted with the mathematical predicted equation and compared with conventional results which fall within a 2% difference. The compressive strength of concrete at any desired age (day) before reaching 28 days results in the discovery of the prediction coefficient. Comparative analysis of the results found by the predicted mathematical model show that, it was very close to the results of the conventional method.

The Effect of Ankle stability exercise and Mobilization on Hip Muscle Strength and Gait in Patients with Acute Ankle Sprain (급성 발목 염좌에 대한 족관절의 관절가동술이 보행과 고관절 근력에 미치는 영향)

  • Jung, Sang-mo;Lee, Jae-nam;Jeon, Jae-hyung
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • Background: In most human lives, 80 percent have problems with the ankle and can be solved with a treatment that is objective in proper assessment. Discrepacts in the ankle are also associated with walking patterns and affect hip and knee joints. An evaluation of hip flexion and extensor muscles was performed to check the strength of hip joints after ankle sprain patients application of arthesis. Methods: In the hospital in Bucheon, 20 outpatients who visited the hospital for treatment with ankle sprain were tested with 10 male and 10 female patients. The criteria for selection of the study subjects were randomly divided into those with joint movement techniques applied to the ankle joints and those with conservative physical therapy. Results: In applying arthrography and preservation physical therapy to patients with ankle sprain, a difference in muscle strength between hip flexion and extensor was noted in post-evaluation comparisons. There were significant differences in the assessment of walking speed and walking time between the two counties in the gait analysis assessment (p<.05). Conclusion: Studies have shown that applying arthrography to people with ankle sprain has a greater therapeutic effect than using conservative physical therapy.

A Study of Hand-Grip Strength Assessment Equipment Prototype for Visual Perception (파악력 평가도구 개발모형에 관한 연구)

  • Kim, Eun-Jeong;Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.17 no.1
    • /
    • pp.24-28
    • /
    • 2011
  • Background: The purpose of this study is to make a grip strength checker to make people measure their grip strength easily, based on standardized grip strength checker chart. Method: In this study, we measured right hand grip strength of 80 women residents of Deajeon (women in their 30s to 60s, 20 in each) 2 times per day for 5days in same conditions from 20th of November 2010 to 24th of November. it was measured by Jamar Hydraculic Hand Dynamometer made lately to compare with the current measuring equipment. No matter how big their hands are, their hands were fixed at second level. Measured as they sit on a chair and let their shoulders gathered and not be rotated, let their arms be 90 degree, wrist and forearm be at the middle for the first time, and took another after they took a rest, and measured the average of the two. Result: There was not a meaningful difference between the current measuring equipment and the equipment made lately (p>.05). Conclusion: It is thought that the equipment made lately can be believed. In addition, we want people to realize their own grip strength easily by this study.

  • PDF

Feasibility Study the Assessment Factor of Quality Performance Index in Expressway Concrete Pavement (고속도로 콘크리트 포장에 대한 품질평가지수 평가인자의 적정성 검토)

  • Lee, Seung Woo;Kim, Gyung il;Ko, Dong Sig;Hong, Seung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.133-141
    • /
    • 2017
  • Traffic volume increases according to highway expansion and industrial development which causes repetitive defect and durability degradation on pavement. The research of quality assurance system used abroad has introduced Korea. Korea Expressway Corporation (KEC) has developed a Quality Performance Index (QPI) that quantitatively assesses the level of quality of the final product, and practical applications. Assessment factor on concrete pavement consisted of pavement thickness, compressive strength, IRI and spacing factor. Assessment factor on concrete pavement is determined by empirical evaluation factor from abroad. In this study, analysis of evaluation factors of concrete pavement by using pavement life prediction simulation and measured data were evaluated with consideration of feasibility of the assessment factor. Pavement life, performance and durability are affected by pavement thickness, compressive strength, IRI and spacing factor in assessment factor on concrete pavement, QPI.

Body mass index and relative handgrip strength are associated with the prevalence of hypertension in Korean elderly: Korean national fitness assessment in 2019

  • Kim, Ji Young;Park, Hun-Young;Kim, Jisu;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.25 no.2
    • /
    • pp.26-32
    • /
    • 2021
  • [Purpose] This study aimed to analyze the prevalence of hypertension according to the body mass index (BMI) and relative handgrip strength (RHGS) among elderly individuals in Korea. [Methods] We analyzed the data of 44,183 Korean elderly individuals over 65 years old (men: n = 15,798, age = 73.31 ± 5.04 years, women: n = 28,385, age = 72.14 ± 5.04 years) obtained from the Korean National Fitness Assessment in 2019. All the participants were categorized into three groups according to the BMI and RHGS; additionally, one-way ANOVA and logistic regression analysis were performed. [Results] Overweight (men: 1.16 odds ratio [OR] 1.06-1.26, 95% confidence interval [CI]; women: 1.15 OR, 1.07-1.23 95% CI) and obese (men: 1.54 OR, 1.42-1.66 95% CI; women: 1.44 OR, 1.36-1.53 95% CI) elderly individuals showed a higher prevalence of hypertension than elderly individuals with normal weight, after controlling for age. In men, a lower RHGS was associated with a higher prevalence of hypertension after controlling for age (weak RHGS: 1.09 OR, 1.00-1.17 95% CI; middle RHGS: 1.21 OR, 1.12-1.31 95% CI vs. strong RHGS). [Conclusion] A higher BMI was associated with the prevalence of hypertension in the elderly Korean population. In addition, a lower RHGS was associated with the prevalence of hypertension in elderly Korean men.