• Title/Summary/Keyword: Strength measurement

Search Result 1,751, Processing Time 0.028 seconds

Attack-Resistant Received Signal Strength based Compressive Sensing Wireless Localization

  • Yan, Jun;Yu, Kegen;Cao, Yangqin;Chen, Liang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.9
    • /
    • pp.4418-4437
    • /
    • 2017
  • In this paper a three-phase secure compressive sensing (CS) and received signal strength (RSS) based target localization approach is proposed to mitigate the effect of malicious node attack. RSS measurements are first arranged into a group of subsets where the same measurement can be included in multiple subsets. Intermediate target position estimates are then produced using individual subsets of RSS measurements and the CS technique. From the intermediate position estimates, the residual error vector and residual error square vector are formed. The least median of residual error square is utilized to define a verifier parameter. The selected residual error vector is utilized along with a threshold to determine whether a node or measurement is under attack. The final target positions are estimated by using only the attack-free measurements and the CS technique. Further, theoretical analysis is performed for parameter selection and computational complexity evaluation. Extensive simulation studies are carried out to demonstrate the advantage of the proposed CS-based secure localization approach over the existing algorithms.

Analysis of Early Behavior of Concrete Pavement with Initial Measurements (콘크리트 포장(鋪裝)의 초기계측(初期計測)을 통한 초기거동(初期擧動) 특성분석(特性分析))

  • Jeong, Won-Kyong;Kim, Dong-Ho;Kwan, Hyouk-Chan;Yun, Kyong-Ku
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.165-173
    • /
    • 2003
  • The purpose of this paper is to analysis of initial behavior of concrete pavement with initial measurement strain gauge for concrete pavement at field, and to investigate the field test results for field applicability testing. The early-age behaviors of concrete pavement slabs were measured using the strain gauges. From the slab depths and positions, the outputs from each gauges were recorded at initial curing period. The initial measurement of concrete pavement and check of crack at the joint were performed, the results could be summarized as follows. From the results of concrete strength, compressive strength and flexural strength were showed $271kgf/cm^2$, $43kgf/cm^2$ respectively. From the tests of early-age strain measurement, it was found that the strain varied at the maximum value of $150{\mu}{\varepsilon}$ and early behavior of concrete slab was showed a tensile strain. However, for long-term was showed a compressive strain due to dry-shrinkage.

  • PDF

Effects of ADMIRE Algorithms on Fat Measurements Using Computed Tomography (CT) (CT를 이용한 지방측정에 ADMIRE 알고리즘이 미치는 영향)

  • Lee, Chang Wook;Lee, Sang Heon;Im, In Chul;Lee, Hyo Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.465-472
    • /
    • 2019
  • To investigate the effects of iterative reconstruction algorithms on fat measurements using computed tomography (CT), we comparatively and quantitatively analyzed the ratios of visceral, subcutaneous, and visceral-subcutaneous fat areas as well as the variations of HU and noise of visceral and subcutaneous fat using ADMIRE strength and attempted to identify any difference between them. Experimental results showed that no statistically significant difference existed among the visceral, subcutaneous, and visceral-subcutaneous fat area ratios HU of visceral fat area and HU of subcutaneous fat area when applying ADMIRE as compared with existing conventional filtered back projection algorithms. However, as the ADMIRE strength increases, the noise of visceral and subcutaneous fat decreases by up to 12.1% and 19.2%, respectively. In conclusion, iterative reconstruction algorithms have no effect on the visceral, subcutaneous, and visceral-subcutaneous fat area ratios, which are indicators of fat measurement using CT.

Analysis for Measured Results in EMF Strength Exposure Level under Base Station Environment for Mobile Communication (이동 통신용 기지국 환경에서 전자파 강도 노출량 측정 결과 분석)

  • Song, Hae-Zu;Kim, Soon-Young;Lee, Moon-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.601-609
    • /
    • 2010
  • This paper measured EMF strength of the duty measurement radio station(77 station) and the non-duty measurement radio station(41 station) of mobile communication base station in Jeonbuk region. As the result of measurement, it generally reveals that EMF is highly low level compare to the human protection guideline. And It is regarded as level that the national people who live close to the mobile communication base station don't have to worry about electromagnetic wave. This paper provides comparative analyses categorized by the duty measurement station and the non-duty measurement station. The results reveals that the average value and the maximum value of the non-duty measurement station preferably was higher than all the duty measurement station. It is thought that the EMF exposure strength of the national people is caused by approach of station antenna rather than antenna power. Consequently this paper suggests that standard of the antenna power(exceed 30 W), standard of antenna height(exceed 10 m) specified by Radio Regulation Act enforcement ordinance, legal basis for mobile communication base station have to be changed.

A STUDY ON THE VOND STRENGTH OF PORCELAIN LAMINATE AND COMPOSITE RESIN CEMENTS (라미네이트 도재와 복합레진 시멘트의 결합강도에 관한 연구)

  • Kim, Sung-Il;Lim, Ho-Nam;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.91-109
    • /
    • 1991
  • The purpose of this study were to comfirm the effects of the thickness and kinds of porcelain, etchants, illumination time, elapsed time for the measurement, and chemical cure component to the bond strength of porcelain laminate and composite resin cement, and to compare the effects between the light cured resin and the dual cured resins. The etched porcelain surface, the sectioned surface crossing porcelain and resin after bonding, and the debonded surfaces were observed by the SEM. One product of laminate porcelain powder, one light cured resin and two dual cured resins were selected. Each resin cements are lightened through the thin porcelain disc which was cut from cylindrical porcelain specimen by the diamond saw, and by the light through the porcelain disc they were bonded. Changes of thickness and kinds of porcelain, etchants, illumination time, and the elapsed time for the measurement were considered as variables for the bond strength. And the bond strength of porcelain and dual cured resins under the conditions of autopolymerization or the removal of chemical cure component were measured and compared. Bond strength were measured by shear stress. The etched surface, the cross-sectioned surface, and the debonded surface of porcelain or resin were observed by SEM. On the summary of this study, the following conclusions can be stated; 1. Bond strength of light cured resin was decreased inversely by the thickened porcelain laminate and showed the lowest value to the masking dentin porcelain among 4 kinds of porcelain powder. 2. Bond strength of autopolymerization of dual cured resin without illumination in dark chamber were from 75% to 98% to the data of dual cured resin with illumination. 3. Bond strength of dual cured resin used without chemical cured components were same to them of light cured resin. 4. Cross-sectioned surface treated by silane did not show the gap between the porcelain and resin. 5. Illumination over 80 seconds did not make the significant increase of bond strength on all kinds of resin.

  • PDF

Adhesion Strength Measurement of Rabbit Knee Chondrocyte (연골세포 부착력 평가)

  • Lee Kwon-Yong;Park Sang-Guk;Shin Daehwan;Park Jong-Chul
    • Tribology and Lubricants
    • /
    • v.21 no.5
    • /
    • pp.236-240
    • /
    • 2005
  • In order to prepare for the suitable surfaces of implants or medical devices, quantitative evaluation of adhesion between cells and biomaterials is essential. To better understand adhesion formation between cells and biomaterials, we used the cytodetachment technique which measures the adhesive force of a single cell through changing the, culture time and detachment speed. The results showed that the adhesive force could be affected by the culture time of cells on the surface of materials and the detachment speed. Moreover, there was a large discrepancy among the adhesion strength measured by similar techniques conducted on the different cells and substrates. It can be 'concluded that the variation of the force measurement technique can seriously alter the level of the force required to detach a cell on the surface of materials.

The Static Overload Effect Estimations on Fatigue Strength by The Measurement of Local Strain Variation at The Weldment Toe (용접 토우부의 국부적 변형률 측정을 통한 용접부의 정적 과하중에 따른 피로강도의 변화 평가)

  • Lee, Hyun-Woo;Kim, Ju-Hwan;Kim, Hyun-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.6
    • /
    • pp.59-66
    • /
    • 2001
  • Fatigue strength of the welding structure is governed by the residual stress at the weldment toe and static tensile overloads were known as relieving the residual stresses. In this study, static tensile overloads were applied to the welding structures which caused the relief of residual stresses. The amount of residual stress relief was found as proportional to the change of fatigue limit at the given conditions. Based on the fact of the proportionality between the change of fatigue limit and that of residual stress, simple measurement technique is proposed. Modified stress-life curves base on proposed technique gave good agreement with test results.

  • PDF

A Study On the Chemical shrinkage and Autogenous Shrinkage of High strength Concrete (고강도 콘크리트의 수화수축과 자기수축의 실험연구)

  • Heo, Woo-Young;Kim, Wha-Jung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.2
    • /
    • pp.81-88
    • /
    • 2004
  • The purpose of this study is to investigate the chemical shrinkage and autogenous shrinkage of high strength cement paste and silica fume and fly ash and sand to cement ratio by the method of volumetric tests, and also investigate the autogenous shrinkage of high measurement method, and compare the results of volumetric test and linear length measurement test. A series of cement paste which have W/C ratio of 25%, 35%, 45% respectively were planed to study the effect of the W/C ratio to the shrinkages, and a series of cement paste which were replaced the cement by the silica fume and fly ash with 5%, 10%, 15% as the mass of cement respectively were planed to investigate the effects of poazolana to the shrinkages. A series of mortar which have a C/S ratio of 1:1, 1:1.5, 1:2 respectively were planed to investigate the shrinkage resistant effect of aggregate.

Evaluation of Physical Properties of Polyurethane Resin for Wound Covering according to PTMG, DMBA Application (PTMG, DMBA 적용에 따른 창상피복 폴리우레탄 수지의 물리적 특성 평가)

  • Lee, Joo-Youb
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.1248-1256
    • /
    • 2020
  • In this study, the polyurethane resin was synthesized by applying PTMG and DMBA of different composition ratios for the synthesis of water-dispersible polyurethane used in wound coating resin. The varying properties of the synthesized water-dispersible polyurethane were measured through tensile strength, elongation, and abrasion resistance analysis. As for the tensile strength measurement result according to the PTMG content, the sample with the highest reaction molar ratio was measured as 1.08 kgf/mm2 and the elongation was measured as 520%. As for the tensile strength result according to the DMBA content, the sample with the highest reaction molar ratio was measured as 0.51 kgf/mm2, and the elongation was measured as 435%. The degree of surface destruction by the abrasion resistance measurement was visually confirmed through SEM.

Analysis of Absorption Loss by a Human Body in On-to-Off Body Communication at 2.45 GHz

  • Jeon, Jaesung;Lee, Sangwoo;Choi, Jaehoon;Kim, Sunwoo
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.2
    • /
    • pp.97-103
    • /
    • 2015
  • This paper investigates the effect of absorption loss by a human body to the received signal strength with respect to on-body transmitting antenna positions in on-to-off wireless body area networks. This investigation is based on measurement results obtained from experiments performed on human bodies (male and female) using planar inverted-F antennas in an anechoic chamber. The total absorption loss by the human body is also presented through the SEMCAD-X simulations. Our investigation showed that the received signal strength becomes lower when the transmitting antenna is mounted at a specific position where more absorption loss is experienced. The statistical analyses of on-to-off body channel characteristics based on the measurement results are presented.