• Title/Summary/Keyword: Strength Evaluation

Search Result 4,839, Processing Time 0.033 seconds

Evaluation of Insulation Characteristics of Submarine Cables in Offshore Wind Farm by Excessive Tension (과도한 인장력에 따른 해상풍력단지 해저케이블의 절연 특성 평가)

  • Seung-Won Lee;Jin-Wook Choe;Ik-Su Kwon;Dong-Eun Kim;Hae‑Jong Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.286-291
    • /
    • 2024
  • Research on aged insulation of cables by stress is constantly being considered for reliable and stable power transmission of offshore wind farms. This study aimed to evaluate the insulation characteristic of aged XLPE (cross-linked polyethylene) insulation for application of offshore wind farms. In this study, The XLPE insulation of cable was set as various mechanical strains. The XLPE insulation is exposed to the mechanical stress below yield strain of 5%, 10%, and 20%. Aged samples were tested by using the method of AC BDV (alternative current breakdown voltage), tensile strength, elongation, and SEM (scanning electron microscope) to obtain insulation characteristics. The experimental results show that the dielectric breakdown of the sample with a strain 20% was 50% lower than the unaged sample; thereby, demonstrating that the mechanical strain that occurred in the submarine cables can weaken the insulation characteristics. Therefore, mechanical strain should be monitored when laying and operating submarine cables for offshore wind farms.

Analysis of Military Capability Balance on the Korean Peninsula Using the Net Assessment Methodology With a Focus on South and North Korean Naval Forces (Surface Combatants) (총괄평가 방법론을 활용한 한반도 군사력 균형분석 - 남·북한 해군력(수상함)을 중심으로 -)

  • Han, Jung-kyeong
    • Maritime Security
    • /
    • v.7 no.1
    • /
    • pp.61-96
    • /
    • 2023
  • Amidst the ongoing instability and military tensions between North and South Korea, it is essential for us to comprehend and assess North Korea's military capabilities, while preparing for potential contingencies through military reinforcement. However, to conduct a comprehensive analysis of the military balance on the Korean Peninsula, it is imperative to move beyond simplistic quantitative comparisons of combat capabilities and embrace a broader perspective, which includes qualitative comparisons of military strength, operational capabilities, and a nation's ability to wage war. To address this need, this study employs the method of "Net Assessment" to evaluate the relative combat power of South and North Korean conventional naval forces, with a particular focus on surface combatants. This evaluation involves both quantitative and qualitative comparisons of military assets (personnel and equipment) and intangible factors (naval strategies, geography, etc.). By conducting a holistic assessment, the research aims to identify and analyze strategic asymmetries that may exist between the two navies.

  • PDF

Static and fatigue performance of short group studs connector in novel post-combination steel-UHPC composite deck

  • Han Xiao;Wei Wang;Chen Xu;Sheraz Abbas;Zhiping Lin
    • Steel and Composite Structures
    • /
    • v.50 no.6
    • /
    • pp.659-674
    • /
    • 2024
  • Casting Ultra High-Performance Concrete (UHPC) on an orthotropic steel deck and forming a composite action by connectors could improve the steel deck fatigue performance. This study presents the mechanical performance of a proposed post-combination connection between UHPC and steel, which had a low constraint effect on UHPC shrinkage. A total of 10 push-out tests were conducted for static and fatigue performance investigations. And the test results were compared with evaluation methods in codes to verify the latter's applicability. Meanwhile, nonlinear simulation and parametric works with material damage plasticity models were also conducted for the static and fatigue failure mechanism understanding. The static and fatigue test results both showed that fractures at stud roots and surrounding local UHPC crushes were the main failure appearances. Compared with normally arranged studs, group arrangement could result in reductions of static stud shear stiffness, strength, and fatigue lives, which were about 18%, 12%, and 27%, respectively. Compared with the test results, stud shear capacity and fatigue lives evaluations based on the codes of AASHTO, Eurocode 4, JSCE and JTG D64 could be applicable in general while the safety redundancies tended to be smaller or even insufficient for group studs. The analysis results showed that arranging studs in groups caused obviously uneven strain distributions. The severer stress concentration and larger strain ranges caused the static and fatigue performance degradations of group studs. The research outcome provides a very important basis for establishing a design method of connections in the novel post-combination steel-UHPC composite deck.

Study on the influence of structural and ground motion uncertainties on the failure mechanism of transmission towers

  • Zhaoyang Fu;Li Tian;Xianchao Luo;Haiyang Pan;Juncai Liu;Chuncheng Liu
    • Earthquakes and Structures
    • /
    • v.26 no.4
    • /
    • pp.311-326
    • /
    • 2024
  • Transmission tower structures are particularly susceptible to damage and even collapse under strong seismic ground motions. Conventional seismic analyses of transmission towers are usually performed by considering only ground motion uncertainty while ignoring structural uncertainty; consequently, the performance evaluation and failure prediction may be inaccurate. In this context, the present study numerically investigates the seismic responses and failure mechanism of transmission towers by considering multiple sources of uncertainty. To this end, an existing transmission tower is chosen, and the corresponding three-dimensional finite element model is created in ABAQUS software. Sensitivity analysis is carried out to identify the relative importance of the uncertain parameters in the seismic responses of transmission towers. The numerical results indicate that the impacts of the structural damping ratio, elastic modulus and yield strength on the seismic responses of the transmission tower are relatively large. Subsequently, a set of 20 uncertainty models are established based on random samples of various parameter combinations generated by the Latin hypercube sampling (LHS) method. An uncertainty analysis is performed for these uncertainty models to clarify the impacts of uncertain structural factors on the seismic responses and failure mechanism (ultimate bearing capacity and failure path). The numerical results show that structural uncertainty has a significant influence on the seismic responses and failure mechanism of transmission towers; different possible failure paths exist for the uncertainty models, whereas only one exists for the deterministic model, and the ultimate bearing capacity of transmission towers is more sensitive to the variation in material parameters than that in geometrical parameters. This research is expected to provide an in-depth understanding of the influence of structural uncertainty on the seismic demand assessment of transmission towers.

Performance Evaluation for Repair of Composite Maintenance Robot Using Carbon Fiber Spray Method (탄소섬유 분사형 복합재 유지보수 로봇의 보수성능평가)

  • Geun-Su Song;Dae-Ham Cheon;Jae-Youl Lee;Kwang-Bok Shin
    • Composites Research
    • /
    • v.37 no.2
    • /
    • pp.76-85
    • /
    • 2024
  • In this paper, a composite maintenance robot using carbon fiber spray method was developed that automatically sprays mixture was created for repair to damaged areas to repair them. To develop a robot, a repair process was developed in which a mixture of milled carbon fiber, epoxy resin, and hardener is sprayed and consolidated on the damaged area. To automate the repair process, an EOAT based on a collaborative robot was developed that can automatically suction and spray the mixture onto the damaged area. To evaluate the repair performance of the robot, 0° and 90° unidirectional specimens were manufactured and tested in accordance with ASTM D3039. Tests were performed on undamaged specimen, damaged specimen, and repaired specimen by a robot after damaged. As a result of the specimen test, the tensile strength of the 0° and 90° specimens was recovered by 10% and 90% after repair. Based on the test results, the repair performance of the developed composite maintenance robot was verified.

Evaluation of Bending Creep Performance of Laminated Veneer Lumber (LVL) Formwork for the Design of Timber Concrete Composite (TCC) Structures

  • Hyun Bae KIM;Takuyuki YOSHIOKA;Kazuhiko FUJITA;Jun ITO;Haruka NOHARA;Keiji NOHARA;Toshiki NARITA;Wonwoo LEE;Arata HOSOKAWA;Tetsuiji TANAKA
    • Journal of the Korean Wood Science and Technology
    • /
    • v.52 no.4
    • /
    • pp.375-382
    • /
    • 2024
  • The study focuses on evaluating the bending creep performance of laminated veneer lumber (LVL) formwork in timber concrete composite (TCC) structures. Timber-framed construction is highlighted for its environmental benefits and seismic resistance, but limitations such as poor tensile strength and brittle failure in bending hinder its use in high-rise buildings. Wood-concrete hybrid structures, particularly those using reinforced concrete slabs with TCC floors, emerge as a potential solution. The research aims to understand the time-dependent behavior of TCC components, considering factors like wood and concrete shrinkage and connection creep. The experiment was conducted in western Japan on the TCC floor designed for use in the Kama-city Inatsuki-higashi compulsory education school. The LVL formwork, measuring 9,000 mm by 900 mm, and concrete is loaded onto it for testing. The creep test periods are examined using concrete loading. It employs a comprehensive creep analysis, adhering to Japanese standards, involving deflection measurements and regression analysis to estimate the creep coefficient. Results indicate substantial deformation after shoring removal, suggesting potential reinforcement needs. The study recommends extending test periods for improved accuracy and recognizing regional climate impacts. Overall, the research provides valuable insights into the potential of LVL formwork in TCC structures, emphasizing safety considerations and paving the way for further experimentation under varied conditions to validate structural integrity.

The Clinical Effects of Applying an Integrated Rehabilitation Protocol during the Recovery Phase for Traumatic Cervical Spinal Cord Injury: A Report of Four Patients (외상성 경추부 척수손상의 회복기 단계에 대한 한양방 통합재활치료 프로토콜 적용의 임상적 효과 증례보고)

  • Gunhee Lee;Seungkwan Choi;Jungho Jo;Hyowon Jin;Seojae Jeon;Junghan Lee;Wonbae Ha
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.34 no.3
    • /
    • pp.107-117
    • /
    • 2024
  • The objective of this study is to report the clinical effects of applying an integrated rehabilitation protocol to four patients with traumatic cervical spinal cord injuries. The treatments applied included acupuncture, cupping and moxibustion, chuna manual therapy, functional electrical stimulation, and other physical therapies. The evaluation methods included American Spinal Injury Association Impairment Scale, functional independence measure (FIM), modified Barthel index (MBI), numeric rating scale (NRS) and other scales. All patients presented marked improvements in FIM, MBI, NRS and other scales, along with increased muscle strength in the manual muscle test. The application of our protocol resulted in clear clinical benefits and enhanced the recovery and quality of life for the patients in this study.

Development of Odor-Reduced Korean Traditional Cheonggukjang Added with Job's Tears (냄새저감형 율무청국장 제조에 관한 연구)

  • Park, Ju-Hun;Han, Chan-Kyu;Choi, Sook-Hyun;Lee, Bog-Hieu;Lee, Hye-Jeong;Kim, Sung-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.2
    • /
    • pp.259-266
    • /
    • 2011
  • This study was performed to develop an odor-reduced Korean traditional Cheonggukjang (fermented soybean paste) by adding Job's tears to Cheonggukjang made with soybean (control) only. The study included the determination of best addition percentage of Job's tears versus soybean, sensory evaluation, and aroma patterns and its components as well as proximate composition analyses of Cheonggukjang. Job's tears Cheonggukjang (CAJT) was prepared by inoculating Bacillus subtilis and fermented at $40^{\circ}C$ for 48 hours. Ratios of soybean : Job's tears for Job's tears Cheonggukjang were 1:1, 2:1, 3:1, and 4:1, respectively. In comparison of proximal composition, Job's tears Cheonggukjang was high in moisture and carbohydrates, but low in calorie, fat, protein, ash and amino nitrogen. The pH of CAJT was lower than those of control and conventional Cheonggukjang (CC) sold in the market, and the acidity was the lowest in CC. The color of Job's tears Cheonggukjang appeared the whiter and more yellowish, but less reddish in proportion to contents of Job's tears. The contents of viscous substances were higher in CAJT compared with those of control and CC. The contents of glutamic acid, the major components of viscous substances were lower in CAJT than in control and CC, and the contents of fructose higher in CAJT. The scores of sensory evaluation were the highest in Job's tears Cheonggukjang mixed with soybean : Job's tears=4:1. The aroma pattern of CC analyzed was conspicuously dissimilar to the control and CAJT and also discriminated by electronic nose examination. The pyrazines, volatile compounds peculiar to Cheonggukjang, were found to be lower in CAJT by SPME-GC/MS assay. Additionally, the acetic acid, butanoic acid, and naphthalene causing off-flavor were identified in CC, but not in Job's tears Cheonggukjang. The strength of odor through sensory evaluation was by far the lowest in CAJT among the groups. From the findings, it had shown that Job's tears Cheonggukjang would be produced successfully when the ratio of 4:1 (soybean : Job's tears) is employed. Also, it was proved that appropriate ratio of Job's tears addition makes Cheonggukjang odor-reduced and well accepted by people.

Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements (고온 금속필터 element 표면에 생성된 반점에 대한 평가)

  • Park, Seung-Chul;Hwang, Tae-Won;Moon, Chan-Kook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Metal filter elements were newly introduced to the high temperature filter(HTF) system in the low- and intermediate-level radioactive waste vitrification plant. In order to evaluate the performance of various metal materials as filter media, elements made of AISI 316L, AISI 904L, and Inconel 600 were included to the test set of filter elements. At the visual inspection to the elements performed after completion of each test, a few dark spots were observed on the surface of some elements. Especially they were found much more at the AISI 316L elements than others. To check the dark spots are the corrosion phenomena or not, two kinds of analyses were performed to the tested filter elements. Firstly, the surfaces or the cross sections of filter specimens cut out from both normal area and dark spot area of elements were analyzed by SEM/EDS. The results showed that the dark spots were not evidences of corrosion but the deposition of sodium, sulfur and silica compounds volatilized from waste or molten glass. Secondly, the ring tensile strength were analyzed for the ring-shape filter specimens cut out from each kind of element. The result obtained from the strength tested showed no evidence of corrosion as well. Conclusionally, depending on the two kinds of analysis, no evidences of corrosion were found at the tested metal filter elements. But the dark spots formed on the surface could reduce the effective filtering area and increase the overall pressure drop of HTF system. Thus, continuous heating inside filter housing up to dew point will be required normally. And a few long-period test should be followed for the exact evaluation of corrosion of the metal filter elements.

  • PDF

Comparison of the Physicochemical Quality Characteristics of Strawberry Jams by Processing Methods (제조방법에 따른 딸기잼의 이화학적 품질 특성 비교)

  • Jung, Nan-Jung;Kang, Yoon-Han
    • Food Science and Preservation
    • /
    • v.19 no.3
    • /
    • pp.337-343
    • /
    • 2012
  • The objective of this study was to characterize three different commercial (A, B and C) and two handmade (HM-AP, atmospheric pressure; HM-RP, reduced pressure) strawberry jams in relation to soluble solids, pH, total acid, total polyphenol, anthocyanin, color values, texture properties, and sensory evaluation. The soluble solid contents varied from 62.33 to 68.33 $^{\circ}Brix$, and the pH ranged from 3.59 to 3.70. The color L and a values were the highest in the HM-RP strawberry jam (p<0.05). The total polyphenol contents of commercial jams A, B, and C were 56.10, 97.59, and 105.85 mg GAE/100 g, respectively, and those of the HM-AP and HM-RP of handmade jams were 156.13 and 189.94 mg GAE/100 g. The anthocyanin contents of A, B, and C commercial jams were 1.51, 0.95, and 0.80 mg/100 g, respectively, and those of the HM-AP and HM-RP handmade jams were 2.64 and 9.16 mg/100 g. The phenolic contents of the HM-RP jam were significantly much higher than those of the other jams. The hardness ranged from $5.67{\times}10^3$ (HM-AP jam) to $41.91{\times}10^3$ (jam B) dyne/$cm^2$, the jelly strength ranged from 40.08 (HM-AP jam) to 180.33 (jam B) dyne, and the strength ranged from 83.84 (jam C) to 302.93 (jam B) g. The sensory evaluation of the color, flavor, sweetness, sourness, viscosity and overall acceptability of the HM-RP jam showed higher values than those of the other jams. Especially, the highest value of the color score was found in the HM-RP jam. The electon donating abilities of jams A, B, and C and of the HM-AP and HM-RP jams were 44.27, 41.70, 53.06, 69.08, and 73.21%, respectively. These results indicated that the HM-RP strawberry jam prepared with reduced pressure using micro-oxygen technology was a good source of phenolic compounds, total polyphenols and anthocyanin, and had a high level of antioxidant activity.