• Title/Summary/Keyword: Strength Coefficient

Search Result 1,836, Processing Time 0.025 seconds

Prediction of Tensile Strength for Friction-Welded Magnesium Alloy Part by Acoustic Emission (AE를 이용한 마그네슘 합금 마찰용접부의 인장강도 예측)

  • Shin, Chang-Min;Kang, Dae-Min;Choi, Jong-Whan;Kwak, Jae-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.2
    • /
    • pp.34-39
    • /
    • 2012
  • In this study, the friction welding experiment was performed by using the design of experiment. And the signal data acquired by acoustic emission sensor were analyzed to predict the tensile strength of friction welding part at friction welding process for AZ31 magnesium alloy. A dimensionless coefficient($\phi_{AE}$), which consisted in the square of AE rms and variance, was defined as the characteristic of friction welding and the prediction equation was obtained by using linear regression. As the result of analysis, it was seen that the correlation between predicted and measured values became very close and on-line prediction of the ensile strength was possible in friction welding part.

An Evaluation of Influencing Parameters on Biaxial Bending Moment Strength of Reinforced Concrete Columns (철근 콘크리트 기둥의 2축휨 강도에 영향을 미치는 변수 고찰)

  • Yoo, Suk-Hyung;Bahn, Byong-Youl;Shin, Sung-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.239-246
    • /
    • 2003
  • In the PCA Load Contour Method, the biaxial bending design coefficient of columns(${\beta}$) is based on the equivalent rectangular stress block (RSB). And coefficient of ${\beta}$ estimates the reinforcement index to be a influencing parameter on biaxial moment strength of RC columns without considering the arbitrary condition of bar arrangement. The experimental results of high strength concrete (HSC) columns subjected to combined axial load and biaxial bending moment were compared to the analysis results of RSB method. As result, the accuracy of RSB method is still acceptable for HSC columns and, as the reinforcement is placed densely in each corner of column section, the ${\beta}$ is decreased.

Tribolgical Characteristics of DLC Film using Substrates with Varying Hardness

  • Park, Jae-Hong;Jang, Beom-Taek;Kim, Seock-Sam
    • KSTLE International Journal
    • /
    • v.9 no.1_2
    • /
    • pp.31-35
    • /
    • 2008
  • DLC (Diamond Like Carbon) films have predominant tribological properties like a high hardness, low friction and high chemical resistance; therefore, DLC films are applied in a wide range of industrial fields. This paper evaluated the characteristics of DLC films deposited on bearing steel with different hardness by RF-PECVD (Radio Frequency - Plasma Enhanced Chemical Vapor Deposition) method. Si-interlayer was deposited on bearing steel to improve adhesion strength by RF-Sputtering method. The DLC film structures were analyzed with Raman spectra and Gaussian function. Adhesion strength of DLC films was measured with a scratch tester. Friction and wear test were carried out with a ball-on -disc type to investigate the tribological characteristics. Experimental results showed that DLC films deposited on bearing steel under same deposition condition have typical structure DLC films regardless of hardness of bearing steel. Adhesion strength of DLC film is increased with a hardness of bearing steel. Friction coefficient of DLC film showed lower at the high hardness of bearing steel.

Development and Application of Unit Table Form using Euro Form for High-rise Building Construction (슬래그 혼입 콘크리트의 염소이온 차단성능)

  • Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.136-137
    • /
    • 2018
  • The properties of concrete produced by ready mixed concrete company in Busan were measured. Because the concrete was mixed with blast furnace slag and fly ash etc., the compressive, tensile strength and chloride ion diffusion coefficient were lower than OPC concrete even though the specified concrete strength was same. If the durability about salt attack were satisfied, the concrete of lower specified concrete strength would be adopted to concrete mixing design. FEM analysis was carried out to predict the life time expectancy.

  • PDF

Calculation of Aging Effects of Ultrasonic Pulse Velocity in Concrete by Non-Destructive Test (비파괴시험에 의한 콘크리트 초음파속도의 재령계수 산정)

  • Cho, Chang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.173-179
    • /
    • 2008
  • This paper aims to calculate age coefficient of ultrasonic pulse velocity by non-destructive test. When concrete compressive strength is measured by non-destructive test, rebound test hammer method is applied to estimate age coefficient depending on the course of time after concrete casting, but ultrasonic pulse velocity method is not applied in the process. Although it is necessary to consider age coefficient with change of ultrasonic pulse velocity of concrete depending on aging, there have been little attempts to apply that method. The experiments were conducted to calculate aging effects which will be applied to establish the formula of measuring concrete strength. As a result of experiments, it was found that ultrasonic pulse velocity showed radical changes depending on concrete hardening in comparison with initial standard values. So, it was concluded that age coefficient must be applied to calculate strength. In conclusion, age coefficient of ultrasonic pulse velocity of concrete was suggested on the basis of experimental results.

Estimation of Aging Effects on Determination of Compressive Strength of Concrete by Non-Destructive Tests (비파괴 시험에 의한 콘크리트 압축강도 및 반발도의 재령계수 추정)

  • 김민수;윤영호;김진근;권영웅;이승석
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.782-788
    • /
    • 2002
  • Several non-destructive test methods have been developed to estimate compressive strength of concrete in other countries. However, their applications are limited in domestic concrete due to their inaccuracies. The purpose of this study is to propose an aging coefficient of compressive strength of structural concrete in rebound number method and ultrasonic pulse velocity method for domestic concrete. The test variables include type of aggregate, curing condition, and compressive strength. Two approaches are used to estimate aging coefficient. One is evaluated by uniform linear regression equation for all ages and shows uniform strength reduction coefficient regardless of material properties and the other is evaluated by individual regression equation for each ages and shows nonuniform strength reduction and rebound increasing coefficients which decrease with increasing of rebound number and compressive strength. The latter result which can include the effect of rebound number and compressive strength is more resonable than the former.

An evolutionary fuzzy modelling approach and comparison of different methods for shear strength prediction of high-strength concrete beams without stirrups

  • Mohammadhassani, Mohammad;Nezamabadi-pour, Hossein;Suhatril, Meldi;shariati, Mahdi
    • Smart Structures and Systems
    • /
    • v.14 no.5
    • /
    • pp.785-809
    • /
    • 2014
  • In this paper, an Adaptive nerou-based inference system (ANFIS) is being used for the prediction of shear strength of high strength concrete (HSC) beams without stirrups. The input parameters comprise of tensile reinforcement ratio, concrete compressive strength and shear span to depth ratio. Additionally, 122 experimental datasets were extracted from the literature review on the HSC beams with some comparable cross sectional dimensions and loading conditions. A comparative analysis has been carried out on the predicted shear strength of HSC beams without stirrups via the ANFIS method with those from the CEB-FIP Model Code (1990), AASHTO LRFD 1994 and CSA A23.3 - 94 codes of design. The shear strength prediction with ANFIS is discovered to be superior to CEB-FIP Model Code (1990), AASHTO LRFD 1994 and CSA A23.3 - 94. The predictions obtained from the ANFIS are harmonious with the test results not accounting for the shear span to depth ratio, tensile reinforcement ratio and concrete compressive strength; the data of the average, variance, correlation coefficient and coefficient of variation (CV) of the ratio between the shear strength predicted using the ANFIS method and the real shear strength are 0.995, 0.014, 0.969 and 11.97%, respectively. Taking a look at the CV index, the shear strength prediction shows better in nonlinear iterations such as the ANFIS for shear strength prediction of HSC beams without stirrups.

Porosity and Strength Properties of Permeable Concrete Using Limestone Mine Wastes as Coarse Aggregate for Concrete (폐석회석 굵은골재를 사용한 투수 콘크리트의 공극 및 강도특성)

  • 최연왕;임학상;정지승;문대중;신화철
    • Resources Recycling
    • /
    • v.12 no.2
    • /
    • pp.11-20
    • /
    • 2003
  • Limestone mine waste was used as a aggregate far permeable concrete. Void ratio, continuous void ratio, coefficient of permeability, compressive strength and flexural strength of concrete were measured and then the relationship between porosity and strength properties was investigated. Void ratio, continuous void ratio and strength properties of permeable concrete were greatly influenced by the grain size of aggregate and void filling ratio in comparison with the containing ratio of limestone mine waste. Furthermore, void ratio showed a good relation with continuous void ratio, and porosity of permeable concrete indicated a good relation with strength properties also. The coefficient of permeability of permeable concrete using limestone waste was over 0.2 cm/sec and was excellent result in comparison with normal concrete. Therefore, it could be expected that the limestone mine waste would be utilized as aggregate for pavement concrete, green concrete and water resource specie concrete in the results of this study.

Physical Properties of Permeable Polymer Concrete (투수성 폴리머 콘크리트의 물리적 성질)

  • 최재진;황의환
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.1
    • /
    • pp.41-48
    • /
    • 2002
  • In this paper, permeable polymer concretes with unsaturated polyester or vinylester resin content from 5 to 8 weight %, resin-filler ratio of 1 : 1, sand content from 0 to 15 weight % and crushed stone of size 2.5∼10 mm were prepared, and tested for compressive strength, flexural strength and water permeability. The effects of the resin and sand contents on the properties of permeable polymer concrete were discussed. It is concluded from the test results that increase in the strength and decrease in the coefficient of permeability of the permeable polymer concrete arc clearly observed with increasing the resin and sand contents. The permeable polymer concrete showed compressive strength in the range of 170 to 350 kgf/$\textrm{cm}^2$ and flexural strength in the range of 40 to 90 kgf/$\textrm{cm}^2$ at coefficient of permeability from 0.1 to 1.0 cm/sec in this experiment.

Effect of the Pore Structure of Concrete on the Compressive Strength of Concrete and Chloride Ions Diffusivity into the Concrete

  • Kim, Jin-Cheol;Paeng, Woo-Seon;Moon, Han-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.345-351
    • /
    • 2003
  • The transport characteristics of deleterious ions such as chlorides depend on the pore structures of concrete and are the major factors in the durability of concrete structures in subjected to chloride attack such as in marine environments. In this paper, the effect of the pore structure on compressive strength and chloride diffusivity of concrete was investigated. Six types of concretes were tested. The pore volume of concrete containing mineral admixtures increased in the range of 3∼30nm due to micro filling effect of hydrates of the mineral admixtures. There was a good correlation between the median pore diameter, the pore volume above 50nm and compressive strength of concrete, but there was not a significant correlation between the total pore volume and compressive strength. The relationship between compressive strength and chloride diffusivity were not well correlated, however, pore volume above 50nm were closely related to the chloride diffusion coefficient.